• 제목/요약/키워드: Korean Wave restriction order

검색결과 8건 처리시간 0.021초

초음파 비선형 전파특성을 이용한 부분 열화 재료의 평가 (The Evaluation of Partially Degraded Material Using Nonlinear Propagation Characteristics of Ultrasonic Wave)

  • 김경조;장경영;야마와키히사시
    • 대한기계학회논문집A
    • /
    • 제25권2호
    • /
    • pp.214-219
    • /
    • 2001
  • In this paper, the nonlinear behavior of ultrasonic wave in partially degraded material is considered. For this aim, FDM(finite difference method) model for the nonlinear wave equation was developed with the restriction to the 1-D longitudinal wave motion and how the partial degradation in material contributes to the detected nonlinear parameter was analyzed quantitatively. In order to verify the rightness of this simulation method, the relation between the detected nonlinear parameter and the continuous distribution of degradation obtained from simulation was compared with experiment results and the simulation and experiment results showed similar tendency. It can be known from simulation result that the degree of degradation, the range of degradation and the continuous distribution of degradation have strong correlation with the detected nonlinear parameter. As it was possible in these simulations that only special part is assumed as degraded one, the quantitative evaluation of partially degraded material may be obtained by using this method.

고차모드를 고려한 사각형 단순 확장관의 간편음향해석법의 개선 (A Modified Simple Acoustic Analysis of Rectangular Simple Expansion Chamber with Consideration of Higher Order Modes)

  • 김봉준;정의봉;황상문
    • 소음진동
    • /
    • 제9권2호
    • /
    • pp.340-347
    • /
    • 1999
  • The acoustic performance of reactive type single expansion chamber can be calculated theoretically by plane wave theory. But higher order model should be considered to widen the frequency range. Mode matching method has been developed to consider higher order modes, but very complicated algebra should be used. Munjal suggested a numerical collocation method, which can overcome the shortcomings of mode matching method, using the compatibility conditions for acoustic pressure and particle velocity at the junctions of area discontinuities. But the restriction of Munjal's method is that the ratio between the area of inlet(or outlet) pipe and that of chamber must be natural number. In this paper, the new method was suggested to overcome the shortcomings of Munjal's method. The predictions by this method was also compared with those by the finite element method and Munjal's method in order to demonstrate the accuracy of the modified method presented here.

  • PDF

초크코일을 이용한 SPD 조합회로의 잔류전압 저감기법 (A Method for Reducing the Residual Voltage of Hybrid SPD Circuit Using Choke Coils)

  • 조성철;엄주홍;이태형
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.250-253
    • /
    • 2007
  • Gas Discharge Tubes (GDTs) are widely used as surge protectors for commnuication applications due to their small internal capacitance. In these days, however, they are mostly used in combined configurations, because the activation voltage required to initiate the discharge process in the GDTs for sufficient amount of time can be large enough to damage surge-sensitive protected circuits. For GDTs with a considerably high initial over-voltage value, we should limit the peak voltage using a TVS or filter. As for ZnO varistors, even though their performance for voltage restriction is excellent, their applications in high-frequency commnuication circuits have been limited because of higher internal capacitance when compared to the GDTs. In order to develop a surge protector for commnuication applications by taking advantages of these two devices, we built a combination circuit that connects a GDT and a ZnO varistor along with a choke coil in common and differential modes. We describe how the applied SPDs operate in protection process steps with the actual data obtained from the residual voltage measurements at each step. The experiment results show that the surge voltage restriction with the choke coil is more effective in 100 [kHz] RingWave voltage than in lightning impulse voltage.

  • PDF

박막을 이용한 저주파수 영역 덕트 소음 저감 방법 (Low Frequency Noise Reduction Inside Duct by Using Membrane)

  • 김양한
    • 한국소음진동공학회논문집
    • /
    • 제14권11호
    • /
    • pp.1083-1090
    • /
    • 2004
  • Two noise reduction systems are proposed in order to overcome the geometric restriction of the reactive muffler such as an expansion chamber. First, membrane is installed as a part of a duct wall and an air cavity is covered outside membrane. Second, membrane is installed inside a duct, which gives no volume change of the duct. Structural-acoustic coupling between membrane and fluid inside the cavity and duct causes rapid impedance mismatching and thereby reflected wave. Theoretical prediction is conducted by using modal expansion approach. The results are compared with the experimental results, which show better noise reduction performance than an expansion chamber.

박막을 이용한 저주파수 영역 덕트 소음 저감 방법 (Low frequency noise reduction inside duct by using membrane)

  • 전종훈;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.474-479
    • /
    • 2004
  • Two noise reduction systems are proposed in order to overcome the geometric restriction of the reactive muffler such as an expansion chamber. First, membrane is installed as a part of a duct wall and an air cavity is covered outside membrane. Second, membrane is installed inside a duct, which gives no volume change of the duct. Structural-acoustic coupling between membrane and fluid inside the cavity and duct causes rapid impedance mismatching and thereby reflected wave. Theoretical prediction is conducted by using modal expansion approach. The results are compared with the experimental results, which show better noise reduction performance than an expansion chamber.

  • PDF

A study on Innovation Methods for the Content Industry in the post-COVID-19 Era

  • Lee, Gun-Woong;Bang, Mee-Young
    • International Journal of Advanced Culture Technology
    • /
    • 제9권3호
    • /
    • pp.142-151
    • /
    • 2021
  • The content industry was greatly affected by the pandemic that hit the world in 2020. The release and production of major Hollywood films were postponed. Performances, festivals, and mega-events such as tourism and the Olympic Games were also canceled or postponed. The innovation of the content industry became inevitable in line with these rapid environmental changes, and the industry had to undergo internal changes according to these external environmental changes. Representative examples are talent fostering and job creation for young people. This study conducts both SWOT analysis and PEST analysis on the South Korean content industry, thereby analyzing cases of talent fostering and job creation suitable for the new environment.

허리 관절을 갖는 4족 로봇의 경사면 보행을 위한 걸음새 생성 방법 (Gait Generation Method for a Quadruped Robot with a Waist Joint to Walk on the Slope)

  • 김국화;최윤호;박진배
    • 한국지능시스템학회논문지
    • /
    • 제22권5호
    • /
    • pp.617-623
    • /
    • 2012
  • 본 논문에서는 4족 로봇의 허리 관절을 이용하여 효율적인 경사면 보행을 위한 걸음새 생성 방법을 제안한다. 허리 관절을 갖는 4족 로봇의 기구학적 모델은 Denavit-Hartenberg 표현 방법과 대수적 방법을 이용하여 유도하고, 다리 이동 순서는 물결 걸음새(wave gait)를 사용한다. 한편 제안한 걸음새 생성 방법에서는 기구적 제한과 보폭의 감소를 완화하기 위해 경사면의 경사도에 따라 적절한 상체 및 하체의 허리 관절각을 결정하고, 에너지 안정도 여유(energy stability margin)를 증가시키기 위해 도달 영역(workspace)의 탐색을 통해 발끝 위치를 결정한다. 마지막으로, 컴퓨터 모의 실험을 통해 본 논문에서 제안한 알고리듬의 효용성 및 실제 적용 가능성을 검증한다.

FPSO 안정성 평가를 위한 절단계류선 모델링 수치 연구 (Numerical Study on Designing Truncated Mooring Lines for FPSO Stability Analysis)

  • 김윤호;조석규;성홍근;서장훈;서용석
    • 한국해양공학회지
    • /
    • 제28권5호
    • /
    • pp.387-395
    • /
    • 2014
  • In this paper, a numerical analysis for an internal turret moored vessel located at a 400-m water depth is conducted. The target vessel has an internal turret that is located at the 0.2 Lpp position from the fore-side, with $3{\times}4$ complex mooring lines installed around the turret circumference. To investigate the motion response of the vessel and the structural reliability of the lines, model tests were conducted. The KRISO ocean basin has a water depth of 3.2 m, which represents 192m using a scaling of 1:60. In order to precisely represent the real-scale condition, equivalent mooring lines needed to be designed. Truncated mooring lines were designed to supplement the restriction of the flume's water depth and increase the reliability of the model testing. These truncated mooring lines were composed of two different chains in order to match the pre-tension, simultaneously restoring the curve and variation in the effective line tension. The static similarities were compared using a static pull-out test and free decaying test, and the dynamic similarities were matched via a regular wave test and combined environments test. Consequently, the designed truncated mooring system could represent the prototype mooring system relatively well in the aspects of kinematics and dynamics.