• Title/Summary/Keyword: Korean Wave 4.0

Search Result 1,246, Processing Time 0.027 seconds

Numerical Study on Wave Run-up of a Circular Cylinder with Various Diffraction Parameters and Body Drafts

  • Jeong, Ho-Jin;Koo, Weoncheol;Kim, Sung-Jae
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.4
    • /
    • pp.245-252
    • /
    • 2020
  • Wave run-up is an important phenomenon that should be considered in ocean structure design. In this study, the wave run-up of a surface-piercing circular cylinder was calculated in the time domain using the three-dimensional linear and fully nonlinear numerical wave tank (NWT) techniques. The NWT was based on the boundary element method and the mixed Eulerian and Lagrangian method. Stokes second-order waves were applied to evaluate the effect of the nonlinear waves on wave run-up, and an artificial damping zone was adopted to reduce the amount of reflected and re-reflected waves from the sidewall of the NWT. Parametric studies were conducted to determine the effect of wavelength, wave steepness, and the draft of the cylinder on the wave run-up of the cylinder. The maximum wave run-up value occurred at 0°, which was in front of the cylinder, and the minimum value occurred near the circumferential angle of 135°. As the diffraction parameter increased, the wave run-up increased up to 1.7 times the wave height. Furthermore, the wave run-up was 4% higher than the linear wave when the wave steepness was 1/35. In particular, the crest height of the wave run-up increased by 8%.

Airside Performance of Fin-and-Tube Heat Exchangers Having Round Wave Fins (둥근 웨이브 핀-관 열교환기의 공기 측 전열 성능)

  • Kim, Nae-Hyun
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.105-116
    • /
    • 2015
  • In this study, airside performance of round fin-and-tube heat exchangers are compared with that of the herringbone wave fin-and-tube heat exchangers with an aim to investigate the effect of fin shape on thermal performance. Results show that j factors of the round wave fin are 1.2~22% larger than those of herringbone wave fin. The f factors of the round wave fin are -1.0~29% smaller than those of herringbone wave fin for 1 or 2 row configuration. For 3 row configuration, f factors of the round wave fin are 8.3~23% larger. The reason may be attributed to the reduced recirculation zone in the valley of the fin for round wave fin as compared with that of the herringbone wave fin. For round wave fin, the effect of fin pitch on j and f factor is not significant. In addition, j factors decrease as the number of tube row increases. On the other hand, f factors are independent of the number of tube row. A new correlation was developed based on the present data.

Prognostic Value of Inferior Shift of P wave Axis after Catheter Ablation for Longstanding Persistent Atrial Fibrillation based on Dallas Lesion Set Including Anterior Line

  • Shin, Dong Geum;Kim, Tae-Hoon;Jeong, Hyunmin;Kim, Alexander;Uhm, Jae-Sun;Joung, Boyoung;Lee, Moon-Hyoung;Hwang, Chun;Pak, Hui-Nam
    • International Journal of Arrhythmia
    • /
    • 제18권2호
    • /
    • pp.66-76
    • /
    • 2017
  • Background and Objectives: Although an anterior linear ablation is an effective lesion set in radiofrequency catheter ablation (RFCA) for longstanding persistent atrial fibrillation (L-PeAF), its durability for bidirectional block (BDB) is only about 60% at repeat procedure. We hypothesized that changes in electrocardiogram (ECG) may predict an anterior line block state and the clinical outcome of L-PeAF ablation. Subjects and Methods: We studied 304 L-PeAF patients (77% male, $60{\pm}10yrs$), who consistently underwent RFCA Dallas lesion set (circumferential pulmonary vein isolation, posterior box lesion, and anterior line) protocol with subsequent comparison of pre-procedural and post-procedural P wave axes, and one year follow-up (n=205) sinus rhythm (SR) ECGs. Results: 1. P wave axis shifted inferiorly at immediate post-procedure (p<0.001), and was independently correlated with BDB of anterior line (${\ss}=10.4$, 95% confidence interval [CI] 2.79-17.94, p=0.008). 2. The degree of post-procedural inferior shift of P wave axis did not reflect clinical recurrence within one-year (n=205, p=0.923), potentially due to conduction recovery of an anterior line. However, among 160 patients without clinical recurrence within one-year, P wave axis at one-year ECG was independently associated with very late recurrence of AF after one-year (n=160, hazard ratio [HR] 0.98; 95% CI 0.97-0.99, p=0.001), during $45.6{\pm}16.7$ months of follow-up. 3. Among 22 patients who underwent repeat procedures, P wave axis shift was more significant in patients with maintained BDB of an anterior line than in those without (p=0.015). Conclusion: An inferior shift of P wave axis reflects the achievement and the maintenance of an anterior line BDB, and is associated with better long-term clinical outcome after catheter ablation for L-PeAF based on Dallas lesion set.

Polarographic Behavior of Oxovanadium (IV) Complex of Mercaptopyridine N-Oxide

  • Shim, Yoon-Bo;Choi, Sung-Nak
    • Bulletin of the Korean Chemical Society
    • /
    • v.8 no.4
    • /
    • pp.225-230
    • /
    • 1987
  • The redox properties of 2-mercaptopyridine N-oxide (mpno) and its oxovanadium complex, $VO (mpno)_2$ have been studied by the use of polarography and cyclic voltammetry. The radical anion of mpno is generated in acetone and is adsorbed to the electrode to form an adsorption wave at -0.21 V vs Ag/AgCl electrode. The normal wave appeared at -0.50 V is attributed to the formation of radical anion. The $VO (mpno)_2$ exhibits one oxidation wave at +0.57 V, and two reduction waves at -1.07 V and -1.76 V vs. Ag/AgCl electrode; the oxidation is fully reversible one-electron process ($VO (mpno)_2\;{\leftrightarrow}\;VO(mpno)_2^+ + e).$ The reduction wave at -1.07 V is quasireversible and is arised from the formation of $VO (mpno)_2^-.$ The second reduction wave at -1.76 V is irreversible and this reduction process consists of two one-electron steps. The sulfur containing ligands seem to enhance the stability of lower oxidation state of vanadium while the oxygen or nitrogen donor of the ligands stabilize the higher oxidation state of vanadium when comparisons are made among several oxovanadium complexes.

Development of a Moving Body Type Wave Power Generator using Wave Horizontal Motions and Hydraulic Experiment for Electric Power Production (파의 수평운동을 이용한 가동물체형 파력발전장치의 개발과 전력생산에 관한 수리실험)

  • Hwang, Seong Su;Lee, Dong Soo;Yang, Kyong Uk;Byun, Jung Hwan;Park, Il Heum
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.28 no.2
    • /
    • pp.73-80
    • /
    • 2016
  • To reduce the mechanical energy loss and to get the high energy efficiency, an apparatus of wave power generation inducing a consistent one way rotating motion from the wave reciprocation motions was developed and the hydraulic experiments for the real electric power production were conducted and the results were discussed. In the experiments for the shape of the buoyant tank, the efficiency of the fixed 9 cm diameter type enduring the wave plate weight was 14.6% and this was the best result for all shapes. But although the free sliding type was expected to represent a high efficiency, the experiments did not show a good result as 8.5% efficiency. Therefore, the shape of buoyant tank was decided as the fixed 9 cm diameter type in the next all tests. In the experiments for the various incident waves, when the water depth was 90 cm, the average efficiencies were measured as 3.9% in the 2nd gear, 4.9% in the 3rd gear, 4.9% in the 4th gear, 12.0% in the 5th gear, 10.0% in the 6th gear, 3.1% in the 7th gear, and 3.0% in the 8th gear. Also, when the water depth was 80 cm, the average efficiency was shown as 15.0% with 5th gear condition. Therefore the high average efficiency as 13.5% was given with 80~90 cm water depth and the 5th gear in the model.

Development of EM Wave Absorber for Suppression Noise from PCB Using Sendust and Mn-Zn Ferrite (Sendust와 Mn-Zn Ferrite를 이용한 PCB로부터의 전자파 방사 억제용 전파흡수체 개발)

  • Yoon, Sang-Gil;Kim, Dong-Il;Song, Young-Man;Park, Soo-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.2
    • /
    • pp.244-249
    • /
    • 2008
  • In this paper, we designed and fabricated the EM wave absorber consists of Sendust and Mn-Zn ferrite for suppressing EM wave noise from PCB in ISM(Industrial, Scientific and Medical) band of 2.4 GHz. We fabricated several samples in different ratios of Sendust to Mn-Zn ferrite with CPE(Chlorinated Ploy-ethylene) as binder and confirmed that optimum composition ratio of absorbing materials was Sendust. Mn-Zn ferrite : CPE=70:5:20 wt.%. The absorbing abilities were simulated according to different thickness of EM wave absorber as the function of material constants calculated by measured data. Measured absorption ability was analyzed and compared with simulated result. The simulated result agree well with the measured ones. As a result, the developed EM wave absorber with thickness of 0.85 mm has absorption ability of 5.4 dB at 2.4 GHz and over 3 dB in frequency rage of 1.4$\sim$4.1 GHz.

Reflection Characteristics of Vortical Slit Caisson Breakwater (종 SLIT형 케이슨 방파제의 반사특성)

  • 이종인;조지훈
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.13 no.4
    • /
    • pp.263-272
    • /
    • 2001
  • Recently, some attempts to construct slit caisson-type breakwaters are made in Korea. Since slit caisson-type breakwaters are suitable for relatively deep sea areas, a lot of theoretical and experimental researches have been performed. In this study, the reflection characteristics of vertical slit caisson breakwaters are investigated based on the measured data in two-dimensional hydraulic model tests with irregular waves. The experiments were conducted for various cases; variation of porosity of perforated-wall, width of wave chamber, number of slits for single-and double-chamber, respectively. It is found that in the case when the wave steepness (H/L$_{s}$ ) is small, the reflection coefficients are large. The existing researches have shown that the wave reflection is minimized when the nondimensional width of wave chamber B/L is about 0.2~0.25 for the regular waves. However, for the irregular waves the reflection is lowest when $B/L_2$, is 0.13~0.15. For a same porosity condition, the wave dissipation is stronger as the width of s1it is larger. The double-chamber caisson is superior to single- chamber caisson in the wave dissipating effects.

  • PDF

Development of Composite Sr Ferrite EM Wave Absorbers for GHz Frequency (GHz 대역용 복합형 Sr 페라이트 전파 흡수체의 개발)

  • Kim, Dong-Il;Moon, Sang-Hyun;Shin, Sung-Jae;Song, Jae-Man;Kim, Ki-Man
    • Journal of Navigation and Port Research
    • /
    • v.28 no.6
    • /
    • pp.503-507
    • /
    • 2004
  • We prepared EM wave absorbers by using recycled Sr ferrite for GHz frequency, and investigated the effects of carbon additions and preparation temperatures on their EM wave absorption properties. A Sr ferrite EM wave absorber with the ratio of Sr ferrite: silicon rubber: carbon = 80 : 13.6: 6.4 wt% prepared at 7$0^{\circ}C$ showed -24 dB at 9.4 GHz and -23 dB at 5.5 GHz for 2 mm and 3 mm thickness, respectively.

Reproduction of Extreme Waves Caused by Typhoon MAEMI with Wave Hindcasting Method, WAM (II) - Characteristics of extreme waves generated by Typhoon MAEMI in the south coast of Korea - (제3세대 파랑추산모형을 이용한 태풍 '매미'의 극한파랑 재현 (II) - 태풍 '매미'가 야기한 우리나라 남해안 일대의 극한파랑 특성 -)

  • Shin Seung-Ho;Hong Keyyong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.11a
    • /
    • pp.219-225
    • /
    • 2004
  • Following a preceding study if Shin et al.(2004), wave fields for a month if September if 2003 are simulated based on the modified WAM cycle 4 model that enables the precise wave hindcasting with fine spatial meshes, and characteristics of extreme waves at the south roast if Koreo are analyzed The accuracy if applied wave model is verified by comparing computed wave parameters and corresponding ones measured at Ieodo ocean research station. The wave hindasting if typhoon 'Maemi' with an hour time interval reveals the extreme wave characteristics at 4 primary locations if south coast of Korea as follows: 1) At the front sea of Chaguido in the south of Jeju-do, the maximum significant wave height, moon wave period and mean wave direction appear to be 7.41m, 13.65s and $6.4^{\circ}$, respectively at 16:00 KST if Sep. 12, 2003. 2) At the entrance of Masan Bay, 12.50m, 13.65s and $1.2^{\circ}$ at 21:00 KST if Sep. 12. 3) At the front sea of Suyoung Bay, 13.85m, 13.81s and $0.2^{\circ}$ at 22;00 KST if Sep. 12. 4) At the front sea of Ulsan port, 11.00m, 13.25s and $28^{\circ}$ at 23:00 KST if Sep.

  • PDF

Determination of Fluoroquinolone Antibacterial Agents by Square Wave Adsorptive Stripping Voltammetry (네모파 흡착 벗김 전압전류법에 의한 플루오로퀴놀론 계 항생제의 검출)

  • Boo, Han-Kil;Song, Youn-Joo;Park, Se-Jin;Chung, Taek-Dong
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.1
    • /
    • pp.63-69
    • /
    • 2010
  • Electrochemical behavior of fluoroquinolone antibacterial agents on carbon paste electrode (CPE) were investigated by cyclic voltammetry and square wave adsorptive stripping voltammetry. The fluoroquinolone antibacterial agents tested in this study were Enrofloxacin (ENR), Norfloxacin (NOR), Ciprofloxacin (CIP), Ofloxacin (OFL) and Levofloxacin (LEV). In acetate buffer at pH 4.5, the oxidation peak potentials of the fluoroquinolone antibacterial agents of ENR, NOR, CIP, OFL, and LEV were 0.952 V, 1.052 V, 1.055 V, 0.983 V, and 0.990 V (vs. Ag/AgCl), respectively. And their oxidation peak currents from square wave adsorptive stripping voltammograms are proportional to the concentration of each antibacterial agent over the range from $0.2\;{\mu}M$ to $1\;{\mu}M$.