Regression Equations for Estimating the TANK Model Parameters (TANK 모형 매개변수 추정을 위한 회귀식 개발)

  • An, Ji Hyun;Song, Jung Hun;Kang, Moon Seong;Song, Inhong;Jun, Sang Min;Park, Jihoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.4
    • /
    • pp.121-133
    • /
    • 2015
  • The TANK model has been widely used in rainfall-runoff modeling due to its simplicity of concept and computation while achieving forecast accuracy. A major barrier to the model application is to determine parameter values for ungauged watersheds, leading to the need of a method for the parameter estimation. The objective of this study was to develop regression equations for estimating the 3th TANK model parameters considering their variations for the ungauged watersheds. Thirty watersheds of dam sites and stream stations were selected for this study. A genetic algorithm was used to optimize TANK model parameters. Watershed characteristics used in this study include land use percent, watershed area, watershed length, and watershed average slope. Generalized equations were derived by correlating to the optimized parameters and the watershed characteristics. The results showed that the TANK model, with the parameters determined by the developed regression equations, performed reasonably with 0.60 to 0.85 of Nash-Sutcliffe efficiency for daily runoff. The developed regression equations for the TANK model can be applied for the runoff simulation particularly for the ungauged watersheds, which is common for upstream of agricultural reservoirs in Korea.

Study on the Characteristics of Hydrogen Storage according to the Structure of Storage Tank using Metal Hydride (수소저장합금을 이용한 수소저장탱크의 구조에 따른 수소저장 특성 연구)

  • Sim, Kyu-Sung;Myung, Kwang-Sik;Kim, Jung-Duk;Kim, Jong-Won
    • Journal of Hydrogen and New Energy
    • /
    • v.13 no.1
    • /
    • pp.90-99
    • /
    • 2002
  • In order to utilize hydrogen energy in a large-scale in the future, development of effective hydrogen storage method is essentially required as well as that of efficient hydrogen production method. The hydrogen storage method using metal hydrides has been holding the spotlight as a safer and higher-density hydrogen storage method than conventional hydrogen storage methods such as liquid hydrogen or compressed hydrogen storage method. However when metals react with hydrogen to store hydrogen as metal hydrides, they undergo exothermic reactions, while metal hydrides evolve hydrogen by endothermic reaction. Therefore, hydrogen storage tank should have such structure that it can absorb or release reaction heat rapidly and efficiently. In this study, a review on the improvement of the heat release and absorption structure in the hydrogen storage tank was conducted, and as a result, a new type of hydrogen storage tank with the structure of vertical-type wall was designed and manufactured. Experimental results showed that this new type of tank could be used as an efficient hydrogen storage tank because its structure is simpler and manufacture is easier than cup-type hydrogen storage tank with the structure of packed horizontal cup.

Study on the Prevention of Corrosion Damage for Underground Fuel Stroage Tank(1) (Corrosion Damage under the Sea Sand) (지하연료저장탱크의 부식손상 방지에 관한 연구(1) (바다모래에서 부식 손상))

  • 임우조;서동철
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.1
    • /
    • pp.65-70
    • /
    • 2001
  • As consumption rate of energy increase rapidly, the facilities of fuel storage tank become large size. Almost all of the industry or public facilities storing fuel in underground fuel storage tank is manufactured by steel materials. Thus, this fuel storage tank made of steel materials is damaged by stray-current corrosion, it become destruction. If fuel storage tank is destructed, petroleum, oil and gas are leaked. So it bring about environmental pollution, energy loss, fire and explosion. Therefor, in this study, for study on the prevention of corrosion damage in underground fuel storage tank, it were investigated by corrosion and stray-current corrosion for SS 400 in dry sea sand and wet sea sand along to specific resistance. The main results obtained are as follows : As specific resistance decrease in wet sea sand, corrosion rate per year increase linearly, in case of back fill up wet sea sand in underground fuel storage tank, if the water is flow into dry sea sand, corrosion tendency of underground fuel storage tank is supposed sensitive.

  • PDF

Seismic Performance Assessment of Atmospheric Surge Tank (노출형 조압수조의 해석모델별 내진성능평가)

  • Kim, Yongon;Ok, Seung-Yong;Kim, Il Gyu;Ryu, Seonho;Bae, Jungjoo
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.5
    • /
    • pp.67-73
    • /
    • 2016
  • This study investigates the seismic performance of the surge tank which is of the atmospheric type and constructed above the ground. For that purpose, three different numerical models of the surge tank have been taken into account. Two models are constructed to describe the surge tank with different support conditions: one is to model all supports as fixed, and the other is to use spring element for the rock conditions. The third model is constructed to describe not only the surge tank with spring element of the rocks but also the vertical waterway tunnel. Through the time-history analysis of the surge tank subjected to three artificially excited ground motions, it is demonstrated that there can be much difference between the three models of our interest according to the support conditions and inclusion of the vertical waterway tunnel. However, their seismic performances still remain below the safety criteria, i.e., dynamic allowable stress. Also, the numerical results let us know where the critical sections occur. These results could be used to develop the efficient seismic enhancement method for the surge tank.

Development of Impact and Fire Hazard Analysis on the Steel Roof of LNG Storage Tank (LNG 저장탱크 강재지붕의 충격 및 화재에 대한 안전성평가기법 개발)

  • Lee, Seung-Rim;Park, Jang-Sik;Lee, Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.34-39
    • /
    • 2009
  • Traditionally all concrete roof type LNG storage tank have been constructing in Korea regardless of LNG tank types. But a steel roof LNG storage tank has merits relatively in designing larger scale tanks and construction cost so it is on the table to apply. This study was carried for the standardized development of impact and fire hazard analysis on a 200,000$k{\ell}$ steel roof LNG storage tank designed by KOGAS and for getting quantitative safety data on a steel roof LNG storage tank compared with a conventional concrete roof LNG storage tank by evaluating with this method. Hazard analysis on each four impact and fire scenarios were developed and evaluated by using finite element methods.

  • PDF

A Study on the Integrated Control and Safety Management System for a LNG Storage Tank (LNG 저장탱크의 통합제어 안전관리 시스템에 관한 연구)

  • Kim Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.1 s.26
    • /
    • pp.44-50
    • /
    • 2005
  • This paper presents integrated control and safety management system for a LNG storage tank. This system is for collecting and analyzing the temperature, pressure, and vibration signals in which are used to control and guarantee the system safety and leakage control from the inner gas tank. Based on the investigations of LNG tank related failures and accidents, we strongly recommend the modification and new development of current safety related measuring and control systems because the LNG tank is constructed bigger and bigger in recent years for the efficiency and safety increments. Thus, this paper presents newly developed integrated control and safety management system for a large LNG storage tank. This system provides the enhanced measuring and control systems, and new displacement based safety system, which may detect and control the deformation properties of tank structures. In addition, we recommend that the new integrated control and safety management system should be coupled by process integrated innovation system (PIIS) for an increased safety, efficiency, and productivity of LNG tanks.

  • PDF

Structural Analysis for Design of Anchor Straps for a Large-Scale LNG Storage Tank with Corner Protection and Inner Tank (코너프로텍션과 내조를 고려한 대용량 LNG 저장탱크 앵커스트랩의 구조설계를 위한 유한요소해석)

  • Jin, Chengzhu;Ha, Sung-Kyu;Kim, Seong-Jong;Lee, Young-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1543-1548
    • /
    • 2011
  • Structural analysis is performed to design anchor straps for a large-scale-liquefied-natural-gas (LNG) storage tank with corner protection and an inner tank by considering structural integrity. Anchor straps made of 9% nickel steel are attached to the inner tank, corner protection, and concrete raft to prevent the failure of the inner tank during both normal and emergency operating conditions. Two finite element (FE) models were analyzed in this study. One is a stand-alone model of the anchor strap, while the other is an extended model of the substructure of the anchor strap, inner tank, and corner protection. Three-dimensional shell elements are used to effectively assess the bending and axial behavior of structures. The Tresca stress values in each part of the two models are calculated for operation under five different load-condition cases: normal operation, leakage of the LNG, hydro test, and two earthquake conditions.

Numerical Study on the Design Safety of $9\%$ Nickel Based Inner Tank Bottom Plate in Terms of Hydrostatic Pressure (유체정압을 고려한 $9\%$ 니켈강재 내부탱크 바닥판의 설계 안정성에 관한 수치적 연구)

  • Kim Chung Kyun;Kim Han Goo
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.2 s.23
    • /
    • pp.35-41
    • /
    • 2004
  • This paper presents the stress and deformation characteristics of $9\%$ nickel based inner tank bottom plate in full containment LNG storage tank. When a . maximum hydrostatic pressure applies the bottom plate of inner tank, the maximum = f stress and displacement distributions of the bottom plate have been analyzed as ' functions of inclined angle of the bottom plate, and the thickness and length of the annular plate between the shell plate and bottom one. The calculated results indicate that the taper of the bottom plate is recommended by 100${\~}$200 : 1 for $140,000m^3$ storage capacity of the inner tank. The results recommend that the thickness of the annular plate is around 20mm and the length is greater than 3m for a maximum hydrostatic pressure of $140,000m^3$ tank capacity.

  • PDF

Stress Analysis of Pressurization Type Propellant Tank in the Satellite (인공위성용 능동가압형 추진제 탱크의 응력 해석)

  • 한근조;심재준;최진철
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.2 no.1
    • /
    • pp.21-30
    • /
    • 1998
  • Design parameters which used to analyze the stress distribution on the tank wall were defined to develop the propellant tank and obtain optimal values. 1/4 modeling of total tank was selected to calculate the stress distribution with respect to the variation of the support lug location and the tank wall thickness and 1/2 modeling was selected for the stress distributions with respect to the variation of fuel outlet location. Actually, 350psi was applied as static load and 12 gravity as a dynamic load during launching on the internal tank wall. The structural analysis was done with respect to attaching condition of the tank in the satellite. Also the effect of the variation of the propellant outlet location from $0^{\cire}$ to $25^{\cire}$ on the stress distribution was investigated. The equivalent stress distribution and optimal parameters induced from analysis results of the each condition will be used as the fundamental data to design the propellant tank.

  • PDF

Design Modification of a Thermal Storage Tank of Natural-Circulation Solar Water Heater for a Pressurized System (자연순환형 태양열 온수기 축열조의 압력식 설계 개조)

  • Boo, Joon-Hong;Jung, Eui-Guk
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.45-54
    • /
    • 2007
  • For a conventional natural-circulation type solar water heater, the pressure head is limited by the height between the storage tank and hot water tap. Therefore, it is difficult to provide sufficient hot water flow rate for general usage. This study deals with a design modification of the storage tank to utilize the tap-water pressure to increase hot-water supply Based on fluid dynamic and heat transfer theories, a series of modeling and simulation is conducted to achieve practical design requirements. An experimental setup is built and tested and the results are compared with theoretical simulation model. The storage tank capacity is 240 l and the outer diameter of piping was 15 mm. Number of tube turns tested are 5, 10, and 15. Starting with initial storage tank temperature of $80^{\circ}C$, the temperature variation of the supply hot water is investigated against time, while maintaining minimum flow rate of 10 1/min. Typical results show that the hot water supply of minimum $30^{\circ}C$ can be maintained for 34 min with tap-water supply pressure of 2.5 atm, The relative errors between modeling and experiments coincide well within 10% in most cases.