• Title/Summary/Keyword: Korean Standard

Search Result 34,579, Processing Time 0.058 seconds

On the Regulation for Pronunciation of Loanwords in Korean (외래어의 표준 발음과 어문 규범)

  • Yi, Eun-gyeong
    • Cross-Cultural Studies
    • /
    • v.38
    • /
    • pp.405-431
    • /
    • 2015
  • The purpose of this paper is to investigate how to decide pronunciation of loanwords in Korean language. There has not been a regulation for pronunciation of loanwords in Korean language. Even the dictionary published by the government does not provide any information about the pronunciation of loanwords. In this paper, some actual solutions are suggested for the pronunciation of loanwords. Korean language has Regulations of Standard Korean, Korean Orthography, Regulations on Hangeul Transcriptions on Loanwords and Pronunciation Methods of Standard Korean. These language standards could help to decide pronunciation of loanwords. Some pronunciations which could not be regulated by them must be presented in the standard pronunciation dictionary. For example, glottalization rule of 's' in many loanwords could be presented in the description of each loanword in the dictionary. However the pronunciation of loanwords must be similar to the spelling. If various pronunciations are allowed to one spelling, then people will be so confused by the discrepancy between pronunciation and spelling of loanwords.

Ripple Effect Analysis of Construction Standard Unit Price in Public Construction (공공건설공사 표준시장단가 적용 파급효과 분석)

  • Jin, Zheng-Xun;Baek, Seung-Ho;Lee, Ju-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_3
    • /
    • pp.1207-1219
    • /
    • 2022
  • 「Act On Contracts To Which The State Is A Party」 stipulates that the "Construction Standard Production Rate" and "Construction Standard Unit Price" be used as the criteria for determining the estimated price of construction works performed by public institutions. In this regard, issues such as the application scope of the Construction Standard Unit Price, and the effect of budget reduction continue. However, due to the lack of quantitative data on the actual application of Construction Standard Unit Price, it is difficult to objectively evaluate various issues. In order to prepare data for objective evaluation of the Construction Standard Unit Price, this study analyzed the ripple effect of applying the Construction Standard Unit Price based on the bill of quantity. As a result of the analysis, the Construction Standard Unit Price ripple effect in the civil engineering part was 9.2%, and it was analyzed that there was a ripple effect of about 1.9% based on the civil engineering direct cost. In the construction part, the ripple effect was analyzed to be relatively high at 17%, but it was found to have a ripple effect of about 3% in the construction direct cost. Based on the total direct cost, the ripple effect was calculated as 2.2%. Based on the analysis results, it is possible to evaluate the effect of applying the Standard Market Unit Price, and it is expected to be used as basic data to solve issues. As a future study, it is necessary to additionally analyze the ripple effect by Standard Market Unit Price application range (over 10 billion, over 20 billion won, etc.) and delivery system type (comprehensive evaluation, qualification examination, technical bidding, etc.). In addition, it is necessary to study the appropriate ripple effect of the Standard Market Unit Price.

A study correspond with international standard on the standard of wheel for railway rolling stock (철도차륜용 차륜규격 국제규격 부합화 연구)

  • Lee Chan-Woo;Hur Hyun-Moo
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.710-713
    • /
    • 2004
  • The domestic railroad industry 2004 April high-speed railroad commerce is the actual condition which is operated and the fact that in spite of railroad standard field many portion does not correspond in international standardize actuality. International standard correspondence propulsion direction and hereafter of railway rolling stock wheel standard it was presented from the research which it sees and the railway rolling stock wheel relation KS standard establishment by law direction it introduced.

  • PDF

Computerization and Application of the Korean Standard Pronunciation Rules (한국어 표준발음법의 전산화 및 응용)

  • 이계영;임재걸
    • Language and Information
    • /
    • v.7 no.2
    • /
    • pp.81-101
    • /
    • 2003
  • This paper introduces a computerized version of the Korean Standard Pronunciation Rules that can be used in speech engineering systems such as Korean speech synthesis and recognition systems. For this purpose, we build Petri net models for each item of the Standard Pronunciation Rules, and then integrate them into the sound conversion table. The reversion of the Korean Standard Pronunciation Rules regulates the way of matching sounds into grammatically correct written characters. This paper presents not only the sound conversion table but also the character conversion table obtained by reversely converting the sound conversion table. Malting use of these tables, we have implemented a Korean character into a sound system and a Korean sound into the character conversion system, and tested them with various data sets reflecting all the items of the Standard Pronunciation Rules to verify the soundness and completeness of our tables. The test results show that the tables improve the process speed in addition to the soundness and completeness.

  • PDF

A Study on Environmental Standards of School Building (교사환경기준에 관한 연구)

  • Hong, Seok-Pyo;Park, Young-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.1 no.1
    • /
    • pp.11-43
    • /
    • 2000
  • The purpose of this study was, through analyzing the previous researches, to grasp the present status of environment of school building(ESB), research the sundry records of each element and, through comparative analysis of the standard of ESB in Korea, the United States, and Japan, select the normative standard of ESB, to clarify the point at issue presented in Regulation of Construction & facility Management for Elementary and and Secondary School in Korea, and to suggest an alternative preliminary standard of ESB. To carry out a research for this purpose, these were required: 1. to investigate the existing present status of ESB, 2. to make a comparative analysis of the standard of ESB in each country, 3. to suggest the normative standard of preliminary standard of ESB, 4. to analyze the controversial points of the standard of ESB in Korea, 5. to suggest an alternative preliminary standard of ESB. The conclusions were as follows: 1. Putting, through analyzing the previous researches, the existing present status of ESB together, it seemed that lighting environment, indoor air environment and noise environment were all in poor conditions. 2. In the result of a comparative analysis of the standard of ESB in Korea, Japan and the United States, in Korea the factors of each lighting and indoor air environment were not presented properly, in Japan, in lighting environment aspect, the standard on natural lighting and the factors on brightness were not presented., and in the USA the essential factors of each environment were throughly presented. In the comparison of the standards on each factor, Korea showed that the standard level presented was less properly prescribed than those of the USA and Japan but it also showed that the standard levels prescribed in the USA and in Japan were mostly similar to the standard levels in records investigated. 3. With the result of the normative standard selection on School Builiding environment factor of prescribed in this study, the controversial points of the standard of ESB in Korea were analyzed and the result was utilized to suggest new preliminary standard of ESB. 4. As the result of the analysis of the controversial points of the standard of ESB in Korea, it was found that the standard of ESB in Korea should be established on a basis of School Health Act and be concretely presented in School Health Regulation and School Health Rule. The factors of each environment was improperly presented in the existing standard of ESB in Korea. Moreover the standard of them was inferior to that of the records investigated and those of in the USA and in Japan and it also showed that the standard of it in Korea was improper to maintain Comfortable Learning Environment. 5. A suggested preliminary standard of ESB acquired through above study as follows: 1) In this study a new kind of preliminary standard of ESB is divided into lighting environment, indoor air environment, noise environment, odor environment and for above classification, reasonable factor and standard should be established and the controling way on each standard and countermeasures against it should be considered. 2) In lighting environment, the factors of natural lighting are divided into daylight rate, brightness, glare. In the standard on each factor, daylight rate should secure 5% of a mean daylight rate and 2% of a minimum daylight rate, brightness ratio of maximum illumination to minimum illumination should be under 10:1, and in glare there should not be an occurrence factor from a reflector outside of the classroom. And the factors of unnatural lighting are illumination, brightness, and glare. In the standard on each factor, illumination should be 750 lux or more, brightness ratio should be under 3 to 1, and glare should not occur. And Optimal reflection rate(%) of Colors and Facilities of Classroom which influences lighting environment should be considered. 3) In indoor air environment factors, thermal factors are divided into (1) room temperature, (2) relative humidity, (3) room air movement, (4) radiation heat, and harmful gases (5) CO, (6) $CO_2$ that are proceeded from using the heating fuel such as oval briquettes, firewood, charcoal being used in most of the classroom, and finally (7) dust. In the standard on each factor, the next are necessary; room temperature: $16^{\circ}C{\sim}26^{\circ}C$(summer : $E.T18.9{\sim}23.8^{\circ}C$, winter: $E.T16.7{\sim}21.7^{\circ}C$), relative humidity: $30{\sim}80%$, room air movement: under 0.5m/sec, radiation heat: under $5^{\circ}C$ gap between dry-bulb temperature and wet-bulb temperature, below 1000 ppm of ca and below 10ppm of $CO_2$, dust: below 0.10 $mg/m^3$ of Volume of dust in indoor air, and ventilation standard($CO_2$) for purification of indoor air : once/6 min.(about 7 times/40 min.) in an airtight classroom. 4) In the standard on noise environment, noise level should be under 40 dB(A) and the noise measuring way and the countermeasures against it should be considered. 5) In the standard on odor environment, odor level under Physical Method should be under 2 degrees, and the inspecting way and the countermeasures against it should be considered.

  • PDF

A Comparative Study on the Ambient Air Quality Standard Strength among Korea, the U.S.A. and the EU (우리나라, 미국 및 유럽의 대기환경기준 강도에 관한 비교 연구)

  • Park, Min-Bin;Lee, Tae-Jung;Lee, Eun-Sun;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.6
    • /
    • pp.559-574
    • /
    • 2016
  • Based on air quality monitoring data ('10~'14) of Suwon City provided by the Korean Department of Environment, a fundamental statistic for 5 criteria pollutants such as $SO_2$, CO, $NO_2$, $O_3$, and $PM_{10}$ was initially investigated. The purpose of this paper was to review the ambient air quality standards(AAQS) of Korea, the U.S.A. and the EU and further to assess the degree of standard strength by the achievability of the AAQS comparing each national standard. Since the level and the way of standards for each air pollutant are various among countries, it is difficult to determine the degree of relative attainment using the same set of data above. Further when all the areas having bad air quality for a specific pollutant are classified as non-attainment case, it is more difficult to assess the degree of standard strength. Thus we introduced a new concept called the average concentration distance (ACD) to quantitatively estimate the strength. As results, the Korean 1-hr $NO_2$ AAQS is slightly stronger than the US standard and weaker than the EU standard. The Korean $O_3$ standard is strongest; however, the Korean $PM_{10}$ standard is weakest. Furthermore the equivalent levels of 8-hr $O_3$ standards in the U.S.A. and the EU were respectively estimated as 97.5 and 95.7 percentiles of the Korean standard with maintaining the existing standard of 60 ppb.

The Judgment Standard of the Compliance of the Documents in the International Standard Banking Pratice (국제표준은행관습상(國際標準銀行慣習上)의 서류(書類)의 일치성(一致性) 판단기준(判斷基準))

  • Chae, Jin-Ik
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.13
    • /
    • pp.631-655
    • /
    • 2000
  • This article is focused on the review of the judgement standard for compliance of the documents in international standard banking practice. Since the establishment of Uniform Customs and Practice for Documentary Credits, The practices of the Credit transactions has been formed and developed with the rapidly changing progress of the international trade environment. but though the international standard banking practice have meaning to suggest a new examination standard, in practice, there are some problems on the judgement of the compliance of the documents. Therefore, for the useful judgement standard for compliance of the documents, the range of the standard should become concrete and simple so that all the related parties can forecast. and the opinions and interpretations published by ICC Banking Committee are recommended to be used, systematized and activated. and also with the change of the trade environment, the changed standard practice could be published annually for the useful use. and it will be necessary to consider to publish the publications in the form of the "White Book" Last, it is necessary to accept the changes by the needs of the times as the international standard banking practice promptly and analysis accurately its problems for the times of the electronic commerce, so that Credit systems should be settled and developed continuously as the useful means of the settlement of the proceeds conquering of the characteristics originated from the international transactions between the parties concerned.

  • PDF

A New Set of Capillary Tube Selection Charts for R-22 in Consideration of the Roughness Effect (조도를 고려한 R-22용 모세관 선정 선도)

  • Kim, C.N.;Hwang, U.P.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.4
    • /
    • pp.681-693
    • /
    • 1995
  • A new set of capillary tube selection charts for R-22 is proposed. The set of charts takes into account of the roughness effect on the mass flow rate. For this purpose, a set of numerical model is developed and a series of experiments is conducted to verify the numerical model. A numerical model is used to calculated the mass flow rate for several sets of tube diameter, length, inlet pressures and degree of subcooling. The outlet of the tube is controlled to be at critical condition. The experimental flow rate is compared with calculated values. The calculated values are consistently less than the experimental ones except for the flow rate range below 40kg/hr. The deviation is within 10---. Based on the nunmerical model and results of experiments, the set of capillary tube selection charts for R-22 is constructed. The set of charts consists of standard capillary tube chart(L=2030mm, d=1.63mm, ${\varepsilon}=2.5{\mu}m$), non -standard flow factor(${\phi}_1$) chart, and non-standard roughness factor(${\phi}_2$) chart. The mass flow rate, flow factor, and the roughness factor are defined respectively as; $\dot{m}={\phi}_1{\phi}_2\dot{m}_{standard}\\{\phi}_1=\frac{\dot{m}(L,\;d,\;\varepsilon_{standard})}{\dot{m}_{standard}(L_{standard},\;d_{standard},\;{\varepsilon}_{standard})}\\{\phi}_2=\frac{\dot{m}(L_{standard},\;d_{standard},\;{\varepsilon})}{\dot{m}_{standard}(L_{standard},\;d_{standard},\;{\varepsilon}_{standard})}$.

  • PDF