• Title/Summary/Keyword: Korean Standard

Search Result 34,581, Processing Time 0.051 seconds

A Study on Floor Slip Resistance Standard and Test Method for BF Certification (BF인증을 위한 바닥 마감재 미끄럼 성능기준 및 측정방법에 대한 연구)

  • Shin, Dong-Hong;Seong, Ki-Chang;Park, Kwang-Jae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.75-83
    • /
    • 2019
  • Purpose: There are no clear criteria for slip performance in the BF certification process, so the evaluator relies on subjective judgments depending on the field situation. Physical criteria for determining the slip performance of various floor finishes are not clear. C.S.R., the only criterion currently being used to check slip performance, may raise questions about its coverage, feasibility and reliability. Method: For an analysis of domestic standards and status, KS L 1001, KS M 3510, and KS F 2375. External standards are analyzed for ADA Standard, ANSI Standard, and BS EN Standard. Analyze the test methods and evaluation criteria of O-Y-PSM, BPT, and the dynamic slip resistance test used in these criteria. It also presents an improvement plan for the rational presentation of standards. Results: To date, various kinds of test methods and measuring devices of the slip resistance coefficient have been developed, but there are not many ways to trust useful results related to user safety. Reliability and thoroughly verified test methods and criteria should be used to assess the slip performance of the floor. In order to improve the standard for the evaluation of slip performance in Korea, the existing standard should first be raised to the same level as the overseas standard, and the application of the discriminatory standard should be applied considering the characteristics and usage patterns of each space. Implication: Currently, Korean standards propose various test methods, but the proper use of test methods, scope and assessment criteria are not established, so improvement of the comprehensive standard is necessary.

A Study on Improvement of Korean Defense Specification Classification System through the Domestic and Foreign Standard Classification System Research and Analysis (국내외 표준 분류체계 조사·분석을 통한 국방규격 분류체계 개선방안 연구)

  • Yeom, Seul-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.457-465
    • /
    • 2021
  • This study analyzed the reality and problems of the defense standard classification system. This paper proposes a plan to perform standard management tasks efficiently through case analysis of domestic and foreign standard classification systems. To continuously solve the problem of military product quality in defense technical data, it is necessary to promptly reflect the civilian's excellent technology and benchmark the civilian standard system to manage high-quality defense standards. First, to analyze the reality, the NATO classification system was analyzed through the private KS of domestic and ICS codes, the US defense standard system of overseas. In the case of the Korean military, the reality of the defense standard classification system was grasped through the National Defense Standards Comprehensive System operated by the Defense Acquisition Program Administration. The classification of the ministry of defense's weapon system and force support system is the most suitable classification system for the Korean military, which is classified into eight weapon systems and six force support standard systems for all steps. Specifically, it was classified into 12 major categories, 66 categories, and 352 sub-categories. In this study, the establishment of the defense standard management system can improve the classification system of new defense standards by reflecting the superior technology of the private sector.

Study on Golden Standard for Sasang Constitution Diagnosis (사상체질진단 표준안 연구)

  • Kim Jong-Won;Jung Sung-Il;Choi Mi-Ok;Kim Kyu-Kon;Lee Eui-Ju;Kim Jong-Yeol;Lee Yong-Tae
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.6
    • /
    • pp.1504-1512
    • /
    • 2005
  • We will develop new sasang constitution diagnosis program. Therefore we need new golden standard for sasang constitution diagnosis. First, we investigated old records and journal of sasang constitutional medicine. Next, we consulted with 10 sasang constitutional experts about new golden standard for sasang constitution diagnosis. The result as follows : Golden standard for Taeyangin : It be made up 42 items(body type 6 items, external appearance 10 items, mental characteristics 16 items, physiology&pathologic symptoms 10 items). (2) Golden standard for Soyangin. It be made up 63 items(body type 7 items, external appearance 28 items, mental characteristics 17 items, physiology&pathologic symptoms 10 items). (3) Golden standard for Taeeumin : It be made up 71 items(body type 12 items, external appearance 19 items, mental characteristics 28 items, physiology&pathologic symptoms 12 items). (4) Golden standard for Soeumin : It be made up 54 items(body type 11 items, external appearance 13items, mental characteristics 21 items, physiology&pathologic symptoms 9 items).

A Study on Reduction Factor in Allowable Current of IEC Low-Voltage Wire (IEC 저압간선의 허용전류 감소계수에 관한 연구)

  • Song, Young-Joo;Lim, Myung-Hwan;Choi, Dae-Won;Kim, Do-Hyung;Yeum, Sung-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.100-108
    • /
    • 2010
  • A low voltage wire should be used considering that a load used in the end is a low voltage. In regard to these wires, there are needs for research about the wire thickness calculation in accordance with IEC standard because the standardization process for IEC (KS standard) was completed on June 30, 2005, and they stopped producing NEC-standard products by the order from Korean Agency for Technology and Standards under Ministry of Knowledge Economy (former Ministry of Commerce, Industry and Energy) since July 1, 2006. This study compared, in terms of the thickness calculation of low voltage wire, a reduction factor application by IEC standard about allowed current and an application for calculation of voltage drop. It also proposed the formula for IEC standard to decrease errors and resolve the difficulty of standardized calculation by analyzing the difference between simplified formula and standardized formula that are the most frequently used calculation method of voltage drop.

The Use of Demand Controlled Ventilation in Multi-Purposed Facility (수요기반 환기량 조절법 (DCV)의 다중이용시설 적용방안)

  • Jeong, Jae-Weon;No, Sang-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.111-116
    • /
    • 2008
  • The objective of this paper was to show the possibility of demand-controlled ventilation (DCV) using the current Korean ventilation standard for multi-purposed facilites. Two attractive DCV approaches; $CO_2$-DCV and RFID-DCV were applied to DCV simulations for a theoretical public assembly space served by a dedicated outdoor air system (DOAS) with enthalpy recovery device. A numerical model for predicting realtime occupant number, ventilation rate, and $CO_2$ concentration under given conditions was developed using a commercial equation solver program. It was found that the current ventilation standard causes unstable ventilation system control in DCV applications, especially under $CO_2$-DCV. It is because the ventilation rate (per person) used in Korea is the sum of the outdoor air required to remove or dilute air contaminants generated by both occupant and building itself, and not a pure function of occupant numbers. Finally, it makes DCV control unstable when ventilation flow is regulated only by the number of occupants. In order for solving this problem, current Korean ventilation standard was modified as a form of ASHRAE Standard 62.1-2007 showing good applicability to various DCV approaches. It was found that this modification enhances applicability of the current ventilation standard to DCV significantly.

  • PDF

FREQUENCY STANDARD AND CLOCK SYSTEM IN VLBI (VLBI의 기준 주파수와 시각 동기 시스템)

  • OH SE-JIN;CHUNG HYUN-SOO;ROH DUK-GYOO;KIM KWANG-DONG
    • Publications of The Korean Astronomical Society
    • /
    • v.19 no.1
    • /
    • pp.93-99
    • /
    • 2004
  • In this paper, we describe a principle of the atomic frequency standard and clock system in VLBI(Very Long Baseline Interferometry). The hydrogen maser is a usual VLBI standard. During VLBI observations, signals emitted by distant sources of radio frequency energy(quasars) are received and recorded at several antennas. At each antenna(VLBI station), a very stable frequency standard(hydrogen maser) provides a reference signal which enables time-tagging to the quasar signals as they are being recorded on magnetic tapes or hard-disk modules. For each VLBl experiment, correlation of the time-tagged recorded information between the participating antennas is used to yield the arrival time differences of any specific quasar radio wave between the antennas. These time differences are used to calculate the relative antennas to each other. In this paper, we also introduce the KVN(Korean VLBI Network) atomic frequency standard and clock system.

An Evaluation of Practical Implementability of Records Management Metadata Standard: With Special Emphasis on its Contextual Elements (기록관리 메타데이터 표준의 실행 적합성 평가 - 맥락 요소를 중심으로 -)

  • Seol, Moon-Won;Cho, Eun-Hee
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.10 no.2
    • /
    • pp.215-243
    • /
    • 2010
  • The purpose of the study is to evaluate Korean Records Management Metadata Standard with special emphasis on the contextual elements in their implementation aspect, and to provide the direction of the Standard revision for improving the metadata quality of RMS developed by National Archives of Korea. The present paper begins with comparing RMS data and the Standard elements, and examines the problems of current accumulation practices of contextual metadata elements in the RMS. Finally it makes some suggestions concerning the Standard revision as well as RMS function upgrade.

Comparison of Emission Characteristics from Euro V Diesel Engine by Standard measurement Cycle in the Construction Equipment (EURO V 대응 건설기계 엔진의 표준시험모드에 따른 배출량 비교)

  • Yu, Seunghun;Joo, Taeheun;Lee, Chang-Eon
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.143-144
    • /
    • 2014
  • The demand of diesel engine on the construction equipment has been rapidly increased because of thermal efficiency and power. But some of the construction equipment is imported from other country, since the their demands are not so large as compared with the other construction equipment. The imported construction equipments will be tested for emission with standard measurement mode. This study was conducted to measure emission characteristics of the construction equipment with changed standard measurement experimentally.

  • PDF

Estimation of Unknown Parameters in Optimum Allocation

  • Park, Hyeonah;Park, Seunghwan;Na, Seongryong
    • Communications for Statistical Applications and Methods
    • /
    • v.20 no.2
    • /
    • pp.137-145
    • /
    • 2013
  • The use of pooled standard deviation can reduce the efficiency loss in optimum allocation when strata standard deviations are estimated and several of them are equal. Also shown is that the pooled standard deviation is useful in optimum allocation under a multivariate setting. In addition to theoretical development, we provide the result of simulation study to support the theory.

RAMS of Railway Control System (열차제어시스템의 신뢰성, 가용성, 유지보수성, 안전성)

  • Kim, Jong-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.391-394
    • /
    • 2003
  • IEC 62278, a standard for Railway applications of RAMS, was established in 2002. This IEC standard is based on CENELEC EN 50126 and covered overall railway fields. Activities that had to be performed from concept to decommissioning and disposal of railway system life-cycle, were contained in this standard. On the flow of internationalization, our Railway Authorities and railway support industry need to understand and apply this standard to railway fields. In this paper Railway RAMS in IEC 62278 is introduced.

  • PDF