• 제목/요약/키워드: Korean Slug

검색결과 214건 처리시간 0.023초

한국산 산민달팽이 (Incilaria fruhstorferi) 전립선의 미세구조 및 조직화학적 연구 (Ultrastructural and Histochemical Study on the Prostate Gland of a Korean Slug, Incilaria fruhstorferi)

  • 장남섭
    • Applied Microscopy
    • /
    • 제27권2호
    • /
    • pp.155-163
    • /
    • 1997
  • Ultrastructural and histochemical studies were carried out on the prostate gland of a Korean slug (Incilaria fruhstorferi) with light and electron microscopes. The results are as follows. The endothelial tissue of the prostate gland is constituted with tall and narrow ciliated columnar cells, irregularly shaped cells and gland cells in which are included the elongated oval or ellipsoid nucleus those are surrounded by curved membrane. The endothelial tissue of the prostate gland is composed by type-A, B, C and type-D gland cells, and the glanules of type-A, B, and D gland cells are certified to neutral mucopolysaccharide because are related by PAS-alcian blue (pH 2.5) , but the other hand type-C gland cell is only weakly reacted to PAS, but strongly reacted by Million reaction. The glanules of type-A gland cell are small size (about $0.4{\mu}m$) and are seen high electron density, but the glanules of type-B gland cell are large size (about $0.7{\mu}m$) and glanule density is same type-A glanules. Long ellipsoid type-C gland cell contained round nucleus which is well developed beterochromatin in, and that small oval glanules (size, about $0.9{\mu}m$) of moderate high electron density which are formed a group of large glanule together with $4\sim5ea$, but type-D gland cell possessed round small nucleus are seen high electron dense glanules (size, $0.8{\mu}m$).

  • PDF

원관내의 이상선회유동 특성에 관한 연구 (The study on the Two-Phase Swirl Flow Characteristics in Cylindrical Pipe)

  • 차경옥;김재근
    • 한국자동차공학회논문집
    • /
    • 제4권1호
    • /
    • pp.187-197
    • /
    • 1996
  • Many investigations have been made to determine the pressure drop and heat transfer characteristics for single phase flow in tape generated swirl flow. But few studies have been carried out to investigate the heat transfer in two component, two phase swirl flow with non-boiling. An experimental study has been conducted to determine the effects of tape twist ratios on two phase convective heat transfer coefficients, pressure drop, and void fraction distribution in a non-boiling, air-water, two phase flow. The flow conditions were both swirl and non swirl flows. The internal diameter of the test section is 42.5mm. The tape twist ratios of pitch to diameter ratio varied from 4.0 to 10.6. The heating conditions were isothermal and nonisothermal. The flow patterns identified with experiments were bubbly, bubbly-slug, slug, and slug-annular flow in up-flow. This study has concluded that no significant difference in void fraction distribution were observed both isothermal and nonisothermal conditions, the pressure drop for two phase flow with twisted tape swirler increase as the tape twist ratio decrease, and that values of two phase heat transfer coefficient increase when the tape twist ratio decreases.

  • PDF

암반대수층 내 순간충격시험 시 관찰된 요동반응의 해석 (Analysis of oscillatory responses of slug tests in a crystalline rock aquifer)

  • 류일호;지성훈;고용권
    • 터널과지하공간
    • /
    • 제19권4호
    • /
    • pp.348-354
    • /
    • 2009
  • 순간충격시험은 대수층의 수리특성을 빠르고 효과적으로 측정할 수 있는 가장 일반적인 방법이다. 한국원 자력연구원(KAERI) 부지 내 YS-4 시추공에서 부지의 수리특성을 알아보기 위하여 순간충격시험을 수행하였고, 그 결과 일반적인 수리반응과 다른 요동수리반응을 관찰하였다. 이 반응결과를 일반적인 해석방법과 시추공내 유체의 관성 영향을 고려한 해석방법으로 해석하여 각각 비교하였다. 그 결과 일반적인 해석 방법으로는 수리전도도가 $3.10{\times}10^{-6}{\sim}3.63{\times}10^{-5}$ m/sec로 예측되어 해석결과의 차이가 크게 나타났지만, 유체의 관성효과를 고려하였을 때는 $4.85{\times}10^{-6}{\sim}5.44{\times}10^{-6}$ m/sec로 그 해석결과가 거의 비슷하였다. 이는 순간충격시험 시 요동수리 반응은 반드시 공내 유체의 관성 효과를 고려하여 해석하여야 함을 보여준다.

Counter-Current Air-Water Flow in Narrow Rectangular Channels With Offset Strip Fins

  • Kim, Byong-Joo;Sohn, Byung-Hu;Koo, Kee-Kahb
    • Journal of Mechanical Science and Technology
    • /
    • 제17권3호
    • /
    • pp.429-439
    • /
    • 2003
  • Counter-current two-phase flows of air- water in narrow rectangular channels with offset strip fins have been experimentally investigated in a 760 mm long and 100 mm wide test section with 3.0 and 5.0 mm gap widths. The two-phase flow regime, channel-average void fractions and two-phase pressure gradients were studied. Flow regime transition occurred at lower superficial velocities of air than in the channels without fins. In the bubbly and slug flow regimes, elongated bubbles rose along the subchannel formed by fins without lateral movement. The critical void fraction for the bubbly-to-slug transition was about 0.14 for the 3 mm gap channel and 0.2 for the 5 mm gap channel. respectively. Channel-average void fractions in the channels with fins were almost the same as those in the channels without fins. Void fractions increased as the gap width increased, especially at high superficial velocity of air. The presence of fins enhanced the two-phase distribution parameter significantly in the slug flow, where the effect of gap width was almost negligible. Superficial velocity of air dominated the two-phase pressure gradients. Liquid superficial velocity and channel gap width has only a minor effect on the pressure gradients.

A Theoretical and Experimental Study of the Steam Condensation Effect on the CCFL in Nearly Horizontal Two- phase Flow

  • Chun, Moon-Hyun;Yu, Seon-Oh
    • Nuclear Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.618-630
    • /
    • 1999
  • An analytical model that includes the steam condensation effect has been derived and a parametric study has been performed. In addition, a series of experiments were performed and a total of 34 experimental data for the onset of CCFL in nearly horizontal countercurrent two-phase How have been obtained for various flow rates of water. Comparisons of the present CCFL data with slug formation models show that the agreement between the present as well as the existing model and the data is about the same. However, the deviation between the Taitel and Dukler's model predictions and the data is the largest when if j$_{f}$<0.04 m/s. A parametric study of the effect of the steam condensation using the present model shows that, when all local conditions are similar, the model predicted local gas velocities that cause the onset of flooding are slightly lower when condensation occurred. Based on the visual observation and the evaluation of the present work, it has been concluded that the criterion derived for the onset of slug flow can be directly used to predict the onset of inner flooding in nearly horizontal two-phase flow within the experimental ranges of the present work.

  • PDF

Transcriptome analysis of the short-term photosynthetic sea slug Placida dendritica

  • Han, Ji Hee;Klochkova, Tatyana A.;Han, Jong Won;Shim, Junbo;Kim, Gwang Hoon
    • ALGAE
    • /
    • 제30권4호
    • /
    • pp.303-312
    • /
    • 2015
  • The intimate physical interaction between food algae and sacoglossan sea slug is a pertinent system to test the theory that “you are what you eat.” Some sacoglossan mollusks ingest and maintain chloroplasts that they acquire from the algae for photosynthesis. The basis of photosynthesis maintenance in these sea slugs was often explained by extensive horizontal gene transfer (HGT) from the food algae to the animal nucleus. Two large-scale expressed sequence tags databases of the green alga Bryopsis plumosa and sea slug Placida dendritica were established using 454 pyrosequencing. Comparison of the transcriptomes showed no possible case of putative HGT, except an actin gene from P. dendritica, designated as PdActin04, which showed 98.9% identity in DNA sequence with the complementary gene from B. plumosa, BpActin03. Highly conserved homologues of this actin gene were found from related green algae, but not in other photosynthetic sea slugs. Phylogenetic analysis showed incongruence between the gene and known organismal phylogenies of the two species. Our data suggest that HGT is not the primary reason underlying the maintenance of short-term kleptoplastidy in Placida dendritica.

Two-Phase Flow Regimes for Counter-Current Air-Water Flows in Narrow Rectangular Channels

  • Kim, Byong-Joo;Sohn, Byung-Hu;Siyoung Jeong
    • Journal of Mechanical Science and Technology
    • /
    • 제15권7호
    • /
    • pp.941-950
    • /
    • 2001
  • A study of counter-current two-phase flow in narrow rectangular channels has been performed. Two-phase flow regimes were experimentally investigated in a 760mm long and 100mm wide test section with 2.0 and 5.0mm gap widths. The resulting flow regime maps were compared with the existing transition criteria. The experimental data and the transition criteria of the models showed relatively good agreement. However, the discrepancies between the experimental data and the model predictions of the flow regime transition become pronounced as the gap width increased. As the gap width increased the transition gas superficial velocities increased. The critical void fraction for the bubbly-to-slug transition was observed to be about 0.25. The two-phase distribution parameter for the slug flow was larger for the narrower channel. The uncertainties in the distribution parameter could lead to a disagreement in slug-to-churn transition between the experimental findings and the transition criteria. For the transition from churn to annular flow the effect of liquid superficial velocity was found to be insignificant.

  • PDF

협소 사각 유로에서 대향류 기/액 2상 유동양식 (Counter-Current Gas-Liquid Two-Phase Flow Regimes in Narrow Rectangular Channels)

  • 손병후;김병주;정시영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.136-141
    • /
    • 2000
  • A study of counter-current two-phase flow in narrow rectangular channels has been performed. Two-phase flow regimes were experimentally studied in 760 mm long and 100 mm wide test sections with 2.0 and 3.0mm gaps. The resulting data have been compared to previous transition models. For the transition from bubbly to slug flow the superficial velocity of gas increased as the gap width increased. The comparison of experimental data to the transition model developed by Taitel and Barnea showed relatively good agreement for the bubbly-to-slug transition in the case of 2mm gap width. For the criteria of Mishima and Ishii to be applicable to the slug-to-churn transition the distribution parameter should be well defined for narrow channels. Even though the gap width of narrow channels increased the superficial gas velocity did not change for the transition form chum to annular flow regime. For the chum-to-annular transition the model of Taitel and Barnea showed discrepancies with experimental data, especially in the channel with larger gap.

  • PDF

강원 유류오염지역의 수리지질 특성 연구 (Hydrogeological Characterization of Petroleum Contaminated area in Kangwon)

  • 최현미;이진용
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제15권2호
    • /
    • pp.1-9
    • /
    • 2010
  • Estimations of porosity and bulk density, particle size analysis of soli samples, tracer test and slug test were performed in a petroleum contaminated area of Kangwon for understanding characteristics of the aquifer. Porosities of the samples were estimated 0.158~0.257, and bulk densities were estimated as $1.73\sim2.10\;g/cm^3$. Majority proportion of the soil samples was 0.5~1.0 mm size. In the soil texture triangle, all samples were distributed at sand area. Uniformity coefficients were estimated as 7.71~10.39, and thus all samples were poorly-sorted. In the tracer test, Darcy velocity was estimated to $4.8\times10^{-6}$ cm/day, effective porosity was 0.175, and longitudinal dispersivity was 0.1 m. According to the slug test, hydraulic conductivities of the test wells were estimated as $2.243\times10^{-2}\sim1.634\times10^{-2}$ cm/sec. These hydrogeologic parameters can be used for efficient remediation design of the petroleum contaminated area.

Onset of Slugging Criterion Based on Singular Point and Stability Analyses of Transient One-Dimensional Two-Phase Flow Equations of Two-Fluid Model

  • Sung, Chang-Kyung;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.299-310
    • /
    • 1996
  • A two-step approach has been used to obtain a new criterion for the onset of slug formation : (1) In the first step, a more general expression than the existing models for the onset of slug flow criterion has been derived from the analysis of singular points and neutral stability conditions of the transient one-dimensional two-phase flow equations of two-fluid model. (2) In the second step, introducing simplifications and incorporating a parameter into the general expression obtained in the first step to satisfy a number of physical conditions a priori specified, a new simple criterion for the onset of slug flow has been derived. Comparisons of the present model with existing models and experimental data show that the present model agrees very closely with Taitel & Dukler's model and experimental data in horizontal pipes. In an inclined pipe ($\theta$ =50$^{\circ}$), however, the difference between the predictions of the present model and those of existing models is appreciably large and the present model gives the best agreement with Ohnuki et al.'s data.

  • PDF