• Title/Summary/Keyword: Korean Slug

Search Result 215, Processing Time 0.023 seconds

Development of Microfluidic Radioimmunoassay Platform for High-throughput Analysis with Reduced Radioactive Waste

  • Jin-Hee Kim;So-Young Lee;Seung-Kon Lee
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.95-101
    • /
    • 2022
  • Microfluidic radioimmunoassay (RIA) platform called µ-RIA spends less reagent and shorter reaction time for the analysis compared to the conventional tube-based radioimmunoassay. This study reported the design of µ-RIA chips optimized for the gamma counter which could measure the small samples of radioactive materials automatically. Compared with the previous study, the µ-RIA chips developed in this study were designed to be compatible with conventional RIA test tubes. And, the automatic gamma counter could detect radioactivity from the 125I labeled anti-PSA attached to the chips. Effects of the multi-layer microchannels and two-phase flow in the µ-RIA chips were investigated in this study. The measured radioactivity from the 125I labeled anti-PSA was linearly proportional to the number of stacked chips, representing that the radioactivity in µ-RIA platform could be amplified by designing the chips with multi-layers. In addition, we designed µ-RIA chip to generate liquid-gas plug flow inside the microfluidic channel. The plug flow can promote binding of the biomolecules onto the microfluidic channel surface with recirculation in the liquid phase. The ratio of liquid slug and air slug length was 1 : 1 when the 125I labeled anti-PSA and the air were injected at 1 and 35 µL/min, respectively, exhibiting 1.6 times higher biomolecule attachment compared to the microfluidic chip without the air injection. This experimental result indicated that the biomolecular reaction was improved by generating liquid-gas slugs inside the microfluidic channel. In this study, we presented a novel µ-RIA chips that is compatible with the conventional gamma counter with automated sampler. Therefore, high-throughput radioimmunoassay can be carried out by the automatic measurement of radioactivity with reduced radiowaste generation. We expect the µ-RIA platform can successfully replace conventional tube-based radioimmunoassay in the future.

Ultrastructural and Histochemical Studies on the Epithelial Cells and Mucus-producing Cells of Korean Slug(Limax flavus L.) (한국산 노랑민달팽이(Limax flavus L.)의 표피상피세포와 점액형성세포에 관한 미세구조 및 조직화학적인 연구)

  • Chang, Nam-Sub
    • Applied Microscopy
    • /
    • v.18 no.2
    • /
    • pp.1-20
    • /
    • 1988
  • The species of the slug used in the experiment is Limax flavus L. For identifying the chemical characteristics of the epidermis, granules and mucus-producing cell of this animal is examined with methylene blue-basic fuchsin double stain and PAS-alcian blue reagent. For the ultrastructural research of the epidermal free surface, the epitheial cell and the parenchymal cell are used with scanning electron microscope and transmission elec-tron microscope respectively. I . Epidermal tissue The epidermal tissue of the slug is observed being divided into the dorsal and the ventral side(toot pad) respectively. 1) Dorsal epidermal tissue The dorsal epidermis of the slug is constituted with the simple columnar epithelium and the microvilli are compacted on the epidermal free surface. Two different types of the secretory granules of the neutral and the acid mucus are observed between the epithelial cells, and the neutral mucous granules are highest electron-dense but the acid mucous granules are observed to be electron-lucent. 2) Foot epidermal tissue The Foot epidermis is formed with the taller simple columnar epithelium than the dorsal epidermis and these cells have both a large number of the microvilli and a few number of the large villi. The secretory granules of three different types, which are acid, neutral and mixed mucous granule of two different types are observed between the epithelial cells. The neutral mucous granules are highest electron dense but the acid mucous granules are observed to be electron-lucent. II . Mucous granule-producing cell and mucus-producing cells Seven different types of the granules-producing cell and the mucus-producing cells are observed between the parenchyma. 1) A-type of acid mucous granule-producing cell The electron-lucent granules are largely occupied in the cytoplasm of these cells and then the granules are surrounded by irregular membrane. These electron-lucent granules exhibit alcianophilia with PAS-alcian blue reaction, so these granules are certified to be acid mucopolysaccharide. 2) B-type of acid mucus-producing cell The nucleus and the cytoplasm of these cells are pushed by the acid mucus of the electron-lucent toward the cell membrane. This mucus has been confirmed to be the acid mucopolysaccharide with PAS-alcian blue reagent. 3) A-type of neutral mucous granule-producing cell These cells contain the electron-dense round granules with approximately $1{\mu}m$ in diameter, which exhibit strongly PAS-positive reaction. These granules are confirmed to be the neutral mucoplysaccharide. 4) B-type of neutral mucous granule-producing cell These cells contain two different types of electron dense granules and electron-lucent granules; The former exhibits to be strongly PAS-positive and the latter to have alcianophilia reaction respectively. 5) C-type of neutral mucus-producing cell These cells are similar to the shape and the size of the B-type of mucus-producing cell but these two different types of cells are stained with reversing properties to each other. The mucus of the C-type cell that electron-lucent is largely occupied in the cytoplasm that exhibits strongly PAS-positive reaction. 6) D-type of neutral mucous granule-producing cell These cells contain round granules about $1{\mu}m$ in size which are observed to be medium electron-dense granules and those granules are stained brightly red with PAS-weak positive reaction. The granules are certified to be neutral mucopolysaccharide. 7) E-type of neutral mucous granule-producing cell These cells are similar to the shape and the size of the D-type of neutral mucous granule-producing cell. These cells contain a large number of granules with about $1{\mu}m$ in diameter showing electron-lucent and then granules are seen to be PAS-weak positive reaction. III. Parenchyma The clear cell and dark cell are found in the parenchyma of the Limax flavus L. 1) Clear cell These cells are round formed and the nucleus of the cells are larger than cytoplasm. These cells which have the electron-lucent cytosol possess poorly developed organelles. 2) Dark cell These cells are found to be dark cells due to high electron-density, which exhibit strongly methylene-blue reaction from double stain of methylene blue-basic fuchsin.

  • PDF

Report on new record of sea slug nudibranch species Cadlinella subornatissima (Gastropoda: Chromodorididae) from Korean waters

  • Jung, Daewui;Gazi, Mohiuddin;Park, Joong-Ki
    • The Korean Journal of Malacology
    • /
    • v.30 no.4
    • /
    • pp.433-435
    • /
    • 2014
  • A chromodorid nudibranch species Cadlinella subornatissima Baba, 1996 (Gastropoda: Nudibranchia: Chromodorididae) is newly recorded from Korean water. In this report, detailed external morphology is provided with its colored illustrations. This species is morphologically distinguished from other congeneric species by the following characteristics: the tip of dorsal papillae is pointed with pink pigment; yellow dorsal marking on central dorsum without mantle margin. The Korean chromodorid nudibranchs are composed of 19 species of 10 genera, including Cadlinella subornatissima which is firstly reported in the present study.

An Experimental Study of The Effects of The Mixing Vane on Air-water Mixed Flow

  • Kim, Soo-Hyung;Baek, Won-Pil;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.331-336
    • /
    • 1996
  • The effects of a mixing vane on air-water mixed flow have been experimentally studied in this work, to investigate the basic mechanisms that the mixing vane affects critical heat flux (CHF). Experiment was performed for various flow rates focusing on bubbly flow and annular flow patterns. Acrylic tube (1.7m long, 11 mm I.D.) and the split vane type mixing vane were used, and ring-type conductance probes were used to measure the liquid film thickness in annular flow. Experimental results show that, (a) bubbly-to slug flow transition and churn-to-annular flow transition occur respectively near the mixing vane compared to the tests without mixing vane, (b) in bubbly flow region, the mixing vane breaks the bubbles into smaller ones and forwards bubbles to the center region of the tube by the centrifugal force, (c) the liquid film thickness in annular flow is decreased near the mixing vane for mass fluxes.

  • PDF

A study on the Inentified Neurons Related to the Visceral Nerve in the Terrestrial Slug, Incilaria fruhstorferi daiseninana. (육생 민달팽이 Incilaria fruhstorferi daiseninana의 내장신경과 관련이 있는 동정된 뉴우런에 관한 연구)

  • Kim, Yung-Kyu;Chang, Joseph-Jin
    • The Korean Journal of Zoology
    • /
    • v.30 no.1
    • /
    • pp.29-43
    • /
    • 1987
  • Incilaria fruhstorferi daiseninana의 뇌는 쌍을 이루고 있는 뇌(cerebral), 측(pleural), 노(parietal), 족(pedal)신경절과 단일 복부(abdominal)신경절로 구성되어 있으며, 이들은 융합된 신경고리를 이루고 있었다. 복부신경절로부터 나오는 내장신경은 생식, 장, 심장, 신장신경등으로 분지되어 이들 각 기관에 신경을 공급하고 있었다. 다음 3가지 방법, 즉, 내장신경을 Ni$^2$+로 역방향으로 충진하여 세포체를 염색하는 방법, 형광화합물 Lucifer yellow를 세포내로 주입하는 방법, 세포내활동전위와 내장신경의 세포외 활동전위를 동시에 측정하는 방법으로 적어도 12가지의 동정된 뉴우런이 내장신경과 관련되고 있음을 알았다. 알아낸 각 세포의 전기생리학적인 특성을 검지하고, 이것과 각 세포의 돌기 분지상태와의 관련 및 일부 세포간의 상호관계를 검사하였다. 이들중 8가지 세포가 내장신경에 축색돌기를 내보내는 효과신경세포라는 증거를 얻었다.

  • PDF

A Mixing Time Measurement by a Conductivity Method in a Continuous Flow Stirred Tank (電氣傳導度 測定에 依한 連續流 攪拌槽의 混合時間 測定)

  • Kang, Woong-Ki
    • Journal of the Korean Chemical Society
    • /
    • v.6 no.2
    • /
    • pp.130-132
    • /
    • 1962
  • A new method of evaluating the mixing time in the continuous flow stirred tank is herein proposed. Experimental results to test the concept are also presented.The mixing time is defined as the time interval between the injection of a slug of an electrolyte solution into the tank and the moment at which an essentially straight line begins on a plot of the conductivity of effluent versus time.The proposed method of measuring the mixing time is valid even for the low mixing time (5 seconds) and the results obtained agree well with previous work, where the mixing time measurements were carried out by the injection of a dye into the feed stream.

  • PDF

Applicability of One-Dimensional Mechanistic Post-Dryout Prediction Model

  • Jeong, Hae-Yong;No, Hee-Cheon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.586-591
    • /
    • 1996
  • Through the analysis of many experimental post-dryout data, it is shown that the most probable flow regime near dryout or quench front is not annular flow but churn-turbulent flow when the mass flux is low. A correlation describing the initial droplet size just after the CHF position at low mass flux is suggested through regression analysis. In the post-dryout region at low pressure and low flow, it is found that the suggested one-dimensional mechanistic model is not applicable when the vapor superficial velocity is very low, i.e., when the flow is bubbly or slug flow regime. This is explained by the change of main entrainment mechanism with the change of flow regime. Therefore, the suggested correlation is valid only in the churn-turbulent flow regime ( $j_{g}$ $^{*}$=0.5~4.5).).

  • PDF

The Improvement of Weldline and Flow mark Defection by using Injection Molding Analysis (사출성형 해석을 통한 Weldline 및 Flow mark 개선사례)

  • Lee, Yeong Chang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.12
    • /
    • pp.1295-1301
    • /
    • 2013
  • The cause of flow mark defect is known as non-uniform temperature of mold surface when the flow front meets the cold cavity. The exact definition and classification of Flow mark is not clear because the mechanism of flow mark is not figured out till now. Any injection molding analysis software can not predict the flow mark phenomena. To solve weldline and flow mark defects, the gate thickness is reduced to increase the melt front velocity and the melt front velocity of the flow mark area is increased from 82.3mm/s to 104.7mm/s. In addition, the bulk temperature of the flow mark area is increased from $178.3^{\circ}C$to $215.2^{\circ}C$ by adding a cold slug well. The flow mark phenomena can be greatly reduced by increasing the flow front velocity and elevating the bulk temperature.

A Study on Pre-Red Mud and Bio-Solids Applicability as Soil Stabilizer (Pre-Red Mud 및 Bio-Solids의 토양 안정화제 활용 가능성에 대한 연구)

  • Yang, Joo-Kyung;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.419-428
    • /
    • 2011
  • Recycling as a stabilizer of industrial by-product can be terms of the proper handling of industrial by-product and positive side in terms of recycling of waste. This study was performed to evaluate has the possibility as stabilizer by primary processing Pre-Red Mud and Bio-Solids which are generated as waste in soils contaminated with heavy metals and compared the efficiency with steel slug being applied in an existing site. In evaluation of the arsenic-fixing ability of stabilizer in batch test, Bio-Solids have the similar arsenic-fixing ability with Pre-Red Mud, which shows 17% h igher arsenic-fixing ability than PS Ball. Since the stabilization periods using Bio-Solids and Pre-Red Mud are faster than the PS Ball, they seems to be better stabilizer than PS Ball to decrease the leaching of arsenic in contaiminated soil.

Experimental Studies on Phase Separation of Steam-Water Two Phase Flow in Horizontal Y-Branching Conduit (수평Y자형 분지관에서 증기-물 이상류의 상분리에 관한 실험적 연구)

  • Ahn, Soo-Whan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.6
    • /
    • pp.886-893
    • /
    • 2000
  • The Characteristics of dividing the dispersed bubble, plug, and slug steam-water flow in the horizontal junctions with horizontal branches have been experimentally investigated. The experimental investigation of the separation phenomena in a $45^{\circ}$ horizontal wye with equal pipe inner diameter of 25 mm is presented to provide a data base for the development and verification of the analytical models. The phase separation and pressure distribution in the three legs of each test section are obtained through the set of measurements made in the present work. And the dependence of phase separation on different parameters, such as inlet quality and mass flux, is discussed.