• Title/Summary/Keyword: Korean Phonation types

Search Result 43, Processing Time 0.018 seconds

Full mouth rehabilitation of mandibular edentulous patient using implant hybrid prosthesis (하악 무치악 환자에서 임플란트 하이브리드 보철물을 이용한 전악 수복 증례)

  • Kim, Seong-Bin;Kim, Sung-Hoi;Park, Young-Bum;Moon, Hong-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.214-220
    • /
    • 2013
  • Implant prosthodontics is beneficial for edentulous patients in enhancing the support, retention, stability, phonation and so on. Various types of prosthesis supported by implant, including implant retained- or supported- overdenture for the removable type and ceramo-metal and fixed prostheses with processed acrylic teeth for the fixed type, are frequently used. Treatment planning for the prosthesis with implant must be made after considering individual characteristics such as form of residual ridge, soft tissue, interocclusal relationship, economic status. Fixed prosthesis with processed acrylic teeth (also known as 'implant hybrid prosthesis' or 'bone anchored bridge') has the advantages of both removable and fixed prosthesis such as proper soft tissue profile, esthetic outcome, increased masticatory efficiency and psychological stability. The 73-years-old female patient came to the department of prosthodontics, Dental hospital of Yonsei University. She was diagnosed with Kennedy class I partial edentulism in the maxilla and complete edentulism in the mandible. This article reports a satisfactory clinical and esthetic outcome of full mouth rehabilitation using removable partial denture in the maxilla and implant hybrid prosthesis in the mandible.

Development and validation of Speech Range Profile task (발화범위 프로파일 과제 개발 및 타당성 검증)

  • Kim, Jaeock;Lee, Seung Jin
    • Phonetics and Speech Sciences
    • /
    • v.11 no.3
    • /
    • pp.77-87
    • /
    • 2019
  • The study aimed to develop Speech Range Profile (SRP) and to examine and validate its clinical application. Forty-five participants without voice disorders aged 18-29 years were compared using SRP and Voice Range Profile (VRP). The authors developed the "Fire!" paragraph as a SRP task compromising 14 sentences including all Korean spoken phonemes and sentence types. To compare SRP and VRP results, the participants read the paragraph (reading) and counted from 21 to 30 (counting) as a part of SRP tasks, and produced a vowel /a/ from low to high frequencies (gliding) and a shortened form of the VRP as a part of VRP tasks. $F0_{max}$, $F0_{min}$, $F0_{range}$, $I_{max}$, $I_{min}$, and $I_{range}$ for each task were measured and compared, showing that $F0_{max}$, $F0_{min}$, $F0_{range}$, $I_{max}$, and $I_{range}$ were not different between reading and gliding. $I_{min}$, had the lowest value in counting. It is concluded that the newly developed SRP task, reading the "Fire" paragraph, can yield a maximum phonation range similar to that found by VRP. Therefore, it is expected that voice evaluation can be effectively performed in a relatively short time by applying SRP with the "Fire" paragraph, a functional utterance task, in place of VRP, which may be difficult to measure long term or in cases of severe voice disorders.

A comparison of acoustic measures among the microphone types for smartphone recordings in normal adults (정상 성인에서 스마트폰 녹음을 위한 마이크 유형 간 음향학적 측정치 비교)

  • Jeong In Park;Seung Jin Lee
    • Phonetics and Speech Sciences
    • /
    • v.16 no.2
    • /
    • pp.49-58
    • /
    • 2024
  • This study aimed to compare the acoustic measurements of speech samples recorded from individuals with normal voices using various devices: the Computerized Speech Lab (CSL), a unidirectional wired pin-microphone (WIRED) suitable for smartphones, the built-in omnidirectional microphone (SMART) of smartphones, and Bluetooth-connected wireless earphones, specifically the Galaxy Buds2 Pro (WIRELESS). This study included 40 normal adults (12 males and 28 females) who had not visited an otolaryngologist for respiratory diseases within the past three months. Participants performed sustained vowel /a/ phonation for four seconds and reading tasks with sentences ("Walk") and paragraphs ("Autumn") in a sound-treated booth. Recordings were simultaneously conducted using the four different devices and synchronized based on the CSL-recorded samples for analysis using the MDVP, ADSV, and VOXplot programs. Compared with CSL, the Cepstral Spectral Index of Dysphonia (CSIDV, CSIDS) and Acoustic Voice Quality Index (AVQI) values were lower in the WIRED and higher in the SMART. The opposite trend was observed for the L/H spectral ratios (SRV and SRS), and the WIRELESS demonstrated task-specific discrepancies. Furthermore, both the fundamental frequency (F0) and the cepstral peak prominence of the vowel samples (CPPV) had intraclass correlation coefficient (ICC) values above 0.9, indicating high reliability. These variables, F0 and CPPV were considered highly reliable for voice recordings across different microphone types. However, caution should be exercised when analyzing and interpreting variables such as the SR, CSID, and AVQI, which may be influenced by the type of microphone used.