Study on the Estimation of Seasonal Ambient Current for the Application of Ambient Adjusted Line Rating(AAR) in Overhead Transmission Lines Using Risk Tolerance(RT) Method (가공송전선로의 AAR 적용 시 Risk Tolerance 분석을 이용한 계절별 최대 허용전류 산정 및 적용에 관한 연구)

  • Lee, Jaegul;Bae, Youngjae;Song, Jiyoung;Shin, Jeonghoon;Kim, Yonghak;Kim, Taekyun;Yoon, Yongbeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.7-15
    • /
    • 2017
  • Ambient Adjusted line Rating(AAR) method for overhead transmission lines considering Risk Tolerance(RT) was proposed in this paper. AAR is suitable for system operators to plan their operation strategy and maintenance schedule because this can be designed as a seasonal line rating. Several candidate transmission lines are chosen to apply the proposed method in the paper. As a result, it is shown that system reliability was significantly enhanced through maximizing transfer capability, solving the system constraints.

KPX Operating Study Summer 2007 (2007년도 하절기 전력계통 운영방안)

  • Hwang, Bong-Hwan;Shin, Yong-Son;Cho, Jong-Man;Song, Seok-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.427-428
    • /
    • 2007
  • This paper presents a study for the Korea power system at yearly peak load time in 2007 summer period. The power system become more complex due to the gradual increment of power demand. We analyze various problems in power system operation, by the use of PSS/E(power flow, fault and transient stability study) and VSAT for voltage stability. The results of power system operating plans and countermeasures are described.

  • PDF

A Study on the Design and Development of the Power Transmission System for Lift Truck (지게차 전용 동력전달시스템의 설계 및 개발에 관한 연구)

  • Jang, Kyoung-Yeol;Park, Joong-Sun;Yoo, Woo-Sik
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.1
    • /
    • pp.34-43
    • /
    • 2009
  • In this thesis, we explain developing processes of the power transmission system for lift truck. Conventional power transmission system had some problems such as spatial constraints or low speed and high torque problem. Because conventional power transmission system was mainly designed for high speed vehicles. In this paper we developed power shift drive axle specialized for $2.0{\sim}3.5$ ton lift truck. Innovative structure of transmission which is built in inside axle, enables to reduce system weight and size by 40% compared to the conventional power transmission system. Also, it is possible to do additional functions such as auto parking system and anti-roll back system.

Protection system of new superconducting power system (초전도(신)전력계통 보호시스템에 관한 기본연구)

  • Lee, Seung-Ryul;Yoon, Jae-Young;Yang, Byeong-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.292-293
    • /
    • 2011
  • We proposed a new power system, Superconducting Power System. The SPS consists of superconducting power cables, fault current limiters, and transformers. The basic concept is to replace 154kV conventional cables with 22.9kV superconducting cables and to convert a 154kV substation into a 22.9kV switching station in downtown area. For the application of the SPS to real power system, it is very important to construct the protection system of the SPS. This study presents a protection system for the new Superconducting Power System (SPS).

  • PDF

Development of kW Class SOFC Systems for Combined Heat and Power Units at KEPRI

  • Lee, Tae-Hee;Choi, Jin-Hyeok;Park, Tae-Sung;Yoo, Keun-Bae;Yoo, Young-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.12
    • /
    • pp.772-776
    • /
    • 2008
  • The Korea Electric Power Research Institute (KEPRI) has been developing planar solid oxide fuel cells (SOFCs) and power systems for combined heat and power (CHP) units. The R&D work includes solid oxide fuel cell (SOFC) materials investigation, design and fabrication of single cells and stacks, and kW class SOFC CHP system development. Anode supported cells composed of Ni-YSZ/FL/YSZ/LSCF were enlarged up to $15{\times}15\;cm^2$ and stacks were manufactured using $10{\times}10\;cm^2$ cells and metallic interconnects such as ferritic stainless steel. The first-generation system had a 37-cell stack and an autothermal reformer for use with city gas. The system showed maximum stack power of about $1.3\;kW_{e,DC}$ and was able to recover heat of $0.57{\sim}1.2\;kW_{th}$ depending on loaded current by making hot water. The second-generation system was composed of an improved 48-cell stack and a prereformer (or steam reformer). The thermal management subsystem design including heat exchangers and insulators was also improved. The second-generation system was successfully operated without any external heat source. Under self-sustainable operation conditions, the stack power was about $1.3\;kW_{e,DC}$ with hydrogen and $1.2\;kW_{e,DC}$ with city. The system also recuperated heat of about $1.1\;kW_{th}$ by making hot water. Recently KEPRI manufactured a 2kW class SOFC stack and a system by scaling up the second-generation 1kW system and will develop a 5kW class CHP system by 2010.

A Design of PC Power-Saving System Security Using IP Address Restriction (IP 주소 제한을 이용한 PC 절전 시스템 보안 설계)

  • Kim, Hong Yoon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.9 no.3
    • /
    • pp.49-57
    • /
    • 2013
  • Power-saving PC software enables the inexpensive power control, but the installation of the power-saving software in all computers in the organization is not an easy task. Computer users in the organization are usually not cooperative as they do not think the power-saving cost is directly related to themselves. The PC power-saving system provides advantage to driving active participation in which users installs the power saving software by restricting IP address through the power management server. However, the problem with this approach is the security vulnerability to IP spoofing attacks, therefore we need to solve the problem that disrupt the entire network system rather than saving electric power. This paper proposes the security authentication system that can implement the efficiency saving power by providing high security for the members' computer system of the public institutions based on the PC power-saving system. Also, by analyzing it in comparison with other method, it is possible to check that the prospects of safety and efficiency are strengthened.

Signal Processing Technology for Fault location System in Underground Power Cable (고장점 탐색 장치를 위한 신호처리 연구)

  • Lee, Jae-Duck;Ryoo, Hee-Suk;Jung, Dong-Hak;Choi, Sang-Bong;Nam, Kee-Young;Jeong, Seong-Hwan;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.712-714
    • /
    • 2005
  • With rapid growth of industry, underground power delivery systems are growing so rapidly and its capacity also growing. So if there are any accident in underground power cable, its inference is too great to count. So power system operators should find Its fault location as soon as possible and replace it But it is difficult to find its fault location for underground power cable. We are developing fault location system for underground power cable which can detect its fault location exactly. This system usually monitor underground power cable on-line But if there are an accident, it record Its transient signal and we can calculate fault location by analyzing it. To develop fault location system for power cable, we needed fault simulation system and we installed it physically and tested at various point. in this thesis, we describe on signal processing technology to detect fault location on power cable and on the result of tested fault location performance.

  • PDF

A Study on Power contorl for Hybrid electric propulsion system (하이브리드 전기 추진 시스템의 전력 제어에 관한 연구)

  • Oh, Jin-Seok;Jo, Kwan-Jun;Ham, Youn-Jae;Bae, Soo-Young;Lee, Ji-Young
    • Journal of Navigation and Port Research
    • /
    • v.32 no.10
    • /
    • pp.765-770
    • /
    • 2008
  • This paper presents the power control for the hybrid electric propulsion system. In this paper, the hybrid propulsion system consists cf the generator and battery as power supply system in ship. The hybrid control system is designed with energy saving algorithm for decreasing the power consumption of power supply system. This paper suggests the method to increase efficiency of hybrid electric propulsion system by developing battery charging system. The performance of power control system is analyzed with the experiment equipment for hybrid propulsion system, and the results showed a good property.

Dynamic Operational Strategies of UPFC in the KEPCO Transmission System

  • Chang, B.H.;Choo, J.B.;Lima, Leonardo T.G.;Feltes, James W.
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.3
    • /
    • pp.168-176
    • /
    • 2003
  • The Korea Electric Power Corporation (KEPCO) has installed an 80 MY A Unified Power Flow Controller (UPFC) at its 154㎸ 'Kang-Jin Substation in South Korea. The device, manufactured by Siemens & Hyusung, has been operational since October 2002. The Korea Electric Power Research Institute (KEPRI), a division of KEPCO was tasked to study operational strategies that could be employed for the UPFC and surrounding reactive support devices concerning problems of low voltages and overloads in the Mokpo & Gwangju areas. Particular apprehension surrounded the possibility of delay in the installation of a new 345㎸ transmission line from 2005 to beyond 2010. The studies were to specifically determine whether these problems could be eliminated by application of a UPFC. The analysis included determining the UPFC operating point under various conditions, investigations of the coordination between the UPFC and a HYDC line terminating in this area, and the design of a supplementary damping controller for the UFPC. This paper summarizes the results of those studies, demonstrating the dynamic characteristics of the operation of this UPFC operation in the Korean power system.

Optimization Power Management System for electric propulsion system (전기추진시스템용 OPMS 기법 연구)

  • Lee, Jong-Hak;Oh, Jin-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.8
    • /
    • pp.923-929
    • /
    • 2019
  • The stability of the propulsion system is crucial for the autonomous vessel. Multiple power generation and propulsion systems should be provided for the stability of the propulsion system. High power generation capacity is calculated for stability, resulting in economical decline due to low load operation. To solve this problem, we need to optimize the power system. In this paper, an OPMS for electric propulsion ship is constructed. The OPMS consists of a hybrid power generation system, an energy storage system, and a control load system. The power generation system consists of a dual fuel engine, the energy storage system is a battery, and the control load system consists of the propulsion load, continuous load, intermittent load, cargo part load and deck machine load. The power system was constructed by modeling the characteristics of each system. For the experiment, a scenario based on ship operation was prepared and the stability and economical efficiency were compared with existing electric propulsion ships.