• Title/Summary/Keyword: Korea mode

Search Result 8,500, Processing Time 0.039 seconds

Passive Mode-Locking of Nd:YAG laser with Saturable Absorber

  • Ahn, Seung-Joon
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.13-19
    • /
    • 1989
  • Passive mode-locking of a pulsed Nd:YAG laser is achieved with saturable absorbers, BDN dye in iodoethane solvent and Kodak Eastman # 26 dye in 1,2-dichloroethane solvent, and its optimum conditions are investigated. The thickness of saturable absorbers employed in the laser mode-locking is 0.16~0.50mm. The PBR (peak-to-background ratio) measured in the oscilloscope is 79.8% in Kodak Eastman # 26 dye at the neighbourhood of the peak power, whereas the passive mode-locking with BDN dye gives PBR of 67.7%. BDN and Kodak Eastman # 26 dyes are superior in photostability over Kodak eastman # 9860 and # 9740 dyes which were used previously in passive mode-locking. From the PBR curve, we find that Kodak Eastman # 26dye is more effective than BDN dye in passive mode-locking. The spacing between the adjacent pulses of the pulse train, which depends on the laser cavity length, is measured and is found to be 7 nsec for the cavity length of 100cm.

  • PDF

Ultralow Intensity Noise Pulse Train from an All-fiber Nonlinear Amplifying Loop Mirror-based Femtosecond Laser

  • Dohyeon Kwon;Dohyun Kim
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.708-713
    • /
    • 2023
  • A robust all-fiber nonlinear amplifying loop-mirror-based mode-locked femtosecond laser is demonstrated. Power-dependent nonlinear phase shift in a Sagnac loop enables stable and power-efficient mode-locking working as an artificial saturable absorber. The pump power is adjusted to achieve the lowest intensity noise for stable long-term operation. The minimum pump power for mode-locking is 180 mW, and the optimal pump power is 300 mW. The lowest integrated root-mean-square relative intensity noise of a free-running mode-locked laser is 0.009% [integration bandwidth: 1 Hz-10 MHz]. The long-term repetition-rate instability of a free-running mode-locked laser is 10-7 over 1,000 s averaging time. The repetition-rate phase noise scaled at 10-GHz carrier is -122 dBc/Hz at 10 kHz Fourier frequency. The demonstrated method can be applied as a seed source in high-precision real-time mid-infrared molecular spectroscopy.

Control Actuator System used in Fuzzy Slide Mode Control (Fuzzy Slide Mode Control을 이용한 Control Actuator System)

  • Yang, Mun-Sang;Lee, Young-Woo;Jung, Sun-Bae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.199-202
    • /
    • 2008
  • 본 논문은 Fuzzy Slide Mode Control 및 BLDC모터를 이용하여 공기의 부하를 모사한 Actuator System에 관한 연구이다. 모터를 제어하기 위한 알고리즘으로 PID, PD, fuzzy Slide Mode Control의 특징을 비교 분석하였고 외란의 영향에 강한 Fuzzy Slide Mode Control을 적용하였다. 모터의 토크를 제어하여 실제 공기 부하에 맞는 토크를 모사함으로써 최대 2.3Nm의 토크와 50Hz의 응답 특성을 얻었다.

  • PDF

Performance Analysis of the Inversion Schemes in the Spotlight-mode SAR(Synthetic Aperture Radar) (Spotlight-mode SAR(Synthetic Aperture Radar)에서의 Inversion 기법 성능 분석)

  • 최정희
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.1
    • /
    • pp.130-138
    • /
    • 2003
  • The classical image reconstruction for stripmap-mode Synthetic Aperture Radar is the Range-Doppler algorithm. When the spotlight-mode SAR system was envisioned, Range-Doppler algorithm turned out to fail rapidly in this SAR imaging modality. Thus, what is referred to as Polar format algorithm, which is based on the Plane wave approximation, was introduced for imaging from spotlight-mode SAR raw- data. In this paper, we have studied for the raw data processing schemes in the spotlight-mode Synthetic Aperture Radar. We apply the Wavefront Reconstruction scheme that does not utilize the approximation in spotlight-mode SAR imaging modelity, and compare the performance of target imaging with the Polar format inversion scheme.

Ductile Fracture Behaviour of SA 533B Pressure Vessel Steel Under Mixed Mode (I/II) Loading (혼합 모드(I/II) 하중에 의한 SA533B 압력용기강의 연성파괴 특성에 관한 연구)

  • O, Dong-Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.11
    • /
    • pp.1829-1834
    • /
    • 2001
  • The aim of this study is to investigate the ductile fracture behavior under mixed mode (I/II) loading using SA533B pressure vessel steel. Anti-symmetric 4-point (AS4P) bonding tests were performed to obtain the J-R curves under two different mixed mode (I/II) loadings. In addition, the fractographic examination of fracture surfaces was carried out to compare with those of pure Mode I and Mode II. In conclusions, the J-R curves under Mixed Mode (I/II) loading were located between those of Mode I and Mode II loadings. When the mixture ratio of mixed mode (I/II) loading was high, the J-R currie of mixed mode (I/II) loading approached that of pure mode I loading after some amount of crack propagation. In contrast with the above fact, if the mixture ratio was low, the J-R curve looked after that of pure mode II loading. The fractographic evidences such as the shape of dimples under different loading conditions supported these conclusions.

Triple-Mode Characteristics of Cylindrical Cavity Loading a Cylindrical Dielectric Resonator

  • Lee, Seung-Mo;Kim, Cha-Man;Park, Jong-Chul;Kim, In-Ryeol;Oh, Soon-Soo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.630-636
    • /
    • 2016
  • In this paper, a novel triple-mode cavity structure, designed for compactness and operating at 850 MHz, is analyzed. A cylindrical dielectric resonator is loaded into a metallic cylindrical cavity. Previous study has been focused on the analysis of the cylindrical dielectric resonator, but in this paper, the effect of the cylindrical metallic cavity has been analyzed. Enclosing the dielectric resonator inside the metallic cavity increases the resonant frequency of the dielectric resonator; however, this increases the quality factor and introduces the possibility of installing coupling screws. The principle of generation of triple-mode was investigated by parametric analysis. The generated triple-mode is TE011 mode and two orthogonally generated HEM121 modes. By adjusting the radius of the dielectric resonator, the height of the dielectric resonator, or the radius of the cylindrical metallic cavity, three modes could be coincided. However, the height of the metallic cavity keeps three modes separated. The mode characteristics of the proposed cavity are analyzed using a full-wave electromagnetic (EM) simulation. The proposed triple-mode cavity could be developed to triple-mode filter using a coupling screw, and the commercial application for the miniaturized filter below 1 GHz could be expected.

Characteristics of Braid bars by Double Fourier Analysis (2중 퓨리에 해석에 의한 망상하천에서 사주의 특성 분석)

  • Jang, Chang-Lae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.529-533
    • /
    • 2012
  • 본 연구에서는 실내실험을 통하여, 하안침식을 고려한 망상하천에서 저수로의 이동특성을 조사하며, 2중 퓨리에 해석에 의하여 사주의 거동특성을 분석하였다. 실내실험은 평균입경이 1.4 mm이고, 표준편차가 1.35인 균일사로 10 cm 의 두께로 전체가 균등하게 채워진, 길이가 12 m, 넓이 2 m 수로에서 수행하였다. 각 시간별 하도의 지형변화에 대하여 2 중 Fourier 해석에 의한 지배적인 성분, 즉 모드(mode)의 변화를 분석하였다. 여기서 1-1 mode는 교호사주(alternate bars)이고, 1-2 mode와 2-2 mode는 2차 횡방향 모드로서 중앙 사주(central bars)를 나타낸다. 1-3 mode와 2-3 mode는 한 단면에서 횡방향으로 3개의 사주가 형성된 것(triple row bars)를 나타낸다. 초기에는 1-1 mode인 교호사주가 지배적이지만, 시간이 증가함에 따라, 교호사주인 1-1 mode는 감소하고, 한 단면에서 3개의 사주가 형성되는 2-3 mode가 지배적인 것으로 나타났다. 이러한 원인은 시간이 지나면서 사주가 발달하고, 하안침식이 되면서, 하폭이 증가하여 상대적으로 수심이 감소하면서 복렬사주가 발달하기 때문이며, Colombini 등(1987)이 이론적으로 예측한 결과와 잘 일치한다. 한 단면에서 3개의 모드가 나타나는 것은 하상에서 변화를 일으키는데 중요한 역할을 한다. 직선하도에서 사주의 수가 증가하는 것은 교호사주의 강한 비선형으로 상호작용하기 때문이다.

  • PDF

Study on the Analysis of Failure Cause and Determination of Life Test Mode of Capsule (축열조 캡슐 고장원인 분석과 수명시험 모드 결정에 관한 연구)

  • Kang, Bosik;Lee, Yongbum;Jung, Dongsoo;Lee, Chungsung
    • Journal of Applied Reliability
    • /
    • v.18 no.3
    • /
    • pp.260-270
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the life of the capsule, which is a core part of the heat storage cooling system. This paper will develop a life test mode that can reproduce environment conditions through the analysis of capsule shrinkage and expansion characteristics. Methods: In order to determine the life test mode of the capsule, this paper analyzed the case of field failures and analyzed the deformation characteristics according to the pressure fluctuation of the capsule. The method to find out whether the field failure and deformation analysis results are consistent is the testing with the construction of the repetition pressure test equipment and the thermal cycle test to reproduce the freezing and thawing characteristics. Results: In this study, failure mode analysis and analysis of freezing and thawing characteristics regarding to the capsule positions were completed. Based on this test & analysis results, this paper have been able to determine the main parameters for determining the life test mode, the freezing and thawing time. Conclusion: Determining the lifetime mode of the capsule can be used to improve the life and performance of the thermal storage system.

Hybrid Current Mode Controller with Fast Response Characteristics for DC/DC Converter (빠른 응답특성을 갖는 DC/DC 컨버터 하이브리드 전류 모드 제어기)

  • Oh, Seung-Min;Baek, Seung-Woo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.2
    • /
    • pp.134-137
    • /
    • 2019
  • A wide-bandwidth current controller is required for fast charging/discharging of super capacitor applications. Peak current mode is generally used to accomplish fast charging/discharging because this mode has fast response characteristics. However, the peak current mode control must have a slope compensation function to restrain sub-harmonics oscillation. The slope must be changed accordingly if the controlled output voltage is varied. However, changing the slope for every changed output voltage is not easy. The other solution, selecting the slope as the maximum value, causes a slow response problem to occur. Therefore, we propose a hybrid mode controller that uses a peak current and a newly specified valley current. Through the proposed hybrid mode control, the sub-harmonic oscillation does not occur when the duty is larger than 0.5 because of the fast response.

A Study on the Photoneutron Dose Estimation in Flattening Filter Mode and Flattening Filter Free Mode for Medical Linear Accelerator (의료용 선형가속기의 Flattening Filter Mode와 Flattening Filter Free Mode 간에 광중성자 선량 평가)

  • Yang, Oh Nam;Lim, Cheong Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.297-302
    • /
    • 2017
  • In this study, the generation of photoneutrons between the 10 MV FF mode and the FFF mode was evaluated and the amount of photoneutrons generated by the 10 MV and 15 MV energy changes in the FFF mode was evaluated. The generated neutrons were evaluated at 13 measurement points and the KTEPC was used to collect the generated neutrons. 10 MV FF mode was measured at 10 MV FF mode and FFF mode at all measurement points. In the superior direction, 0.455mSv and 0.152mSv were the largest, and more than 33% optical neutron was generated in FF. 10 MV in FFF mode, 15 MV in 15 MV, and 0.402 mSv in the direction of Superior, and 6.9% in the direction.