• Title/Summary/Keyword: Korea Research Reactor

Search Result 2,112, Processing Time 0.033 seconds

Development of a Prototype Control Rod Control System (제어봉 구동장치 제어기기 Prototype 개발)

  • Kim, C.K.;Cheon, J.M.;Kim, S.J.;Lee, J.M.;Ahn, J.B.;Kweon, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2182-2184
    • /
    • 2002
  • In this paper we describe a prototype Control Rod Control System(CRCS). The CRCS controls the motion of the full length rod drive mechanisms in response to signals from the Reactor Operator and the Reactor Control System. Each mechanism belongs to either Shutdown Banks or Control Banks. The CRCS also provides information regarding the rod motion, rod position, and the status of the Rod Control System. The prototype CRCS will be used to obtain the requirements for detailed design of a full-scale CRCS.

  • PDF

Passive Heat Removal Characteristics of SMART

  • Seo, Jae-Kwang;Kang, Hyung-Seok;Yoon, Joo-Hyun;Kim, Hwan-Yeol;Cho, Bong-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.623-628
    • /
    • 1998
  • A new advanced integral reactor of 330 MWt thermal capacity named SMART (System-Integrated Modular Advanced Reactor) is currently under development in Korea Atomic Energy Research Institute (KAERI) for multi-purpose applications. Modular once-through steam generator (SG) and self-pressurizing pressurizer equipped with wet thermal insulator and cooler are essential components of the SMART. The SMART Provides safety systems such as Passive Residual Heat Removal System (PRHRS). In this study, a computer code for performance analysis of the PRHRS is developed by modeling relevant components and systems of the SMART. Using this computer code, a performance analysis of the PRHRS is performed in order to check whether the passive cooling concept using the PRHRS is feasible. The results of the analysis show that PRHRDS of the SMART has excellent passive heat removal characteristics.

  • PDF

Biological Fixation of $CO_2$ by Chlorella sp. HA-1 in a Semi-Continuous and Series Reactor System

  • LEE JAE-YOUNG;KWON TAE-SOON;BAEK KITAE;YANG JI-WON
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.3
    • /
    • pp.461-465
    • /
    • 2005
  • Characteristics of biological $CO_2$ fixation by Chlorella sp. HA-1 were investigated in a semi-continuous and series reactor system using an internally illuminated photobioreactor to overcome shortcomings of physicochemical technologies such as adsorption and membrane separation. High $CO_2$ fixation rate was achieved in the semi-continuous reactor system, in which the dilution ratios of the culture medium were controlled. The average $CO_2$ fixation rate was maintained almost constantly when the dilution ratio increased by 0.1 increment from the initial value of 0.5. The total removal efficiency of $CO_2$ was enhanced by employing a series reactor system. The average $CO_2$ fixation rate increased until 4.013 g $CO_2\;day^{-1}$ in a series operation of four reactors, compared to 0.986 g $CO_2\;day^{-1}$ in a batch operation mode. The total $CO_2$ fixation rate was proportional to the number of reactors used in the series reactor system. In the series reactor system of semi-continuous operation, a large amount of $CO_2$ was removed continuously for 30 days. These results showed that the present reactor systems are efficient and economically feasible for a biological $CO_2$ fixation.

Design and Performance of an Automated Bioreactor for Cell Culture Experiments in a Microgravity Environment

  • Kim, Youn-Kyu;Park, Seul-Hyun;Lee, Joo-Hee;Choi, Gi-Hyuk
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.1
    • /
    • pp.81-89
    • /
    • 2015
  • In this paper, we describe the development of a bioreactor for a cell-culture experiment on the International Space Station (ISS). The bioreactor is an experimental device for culturing mouse muscle cells in a microgravity environment. The purpose of the experiment was to assess the impact of microgravity on the muscles to address the possibility of long-term human residence in space. After investigation of previously developed bioreactors, and analysis of the requirements for microgravity cell culture experiments, a bioreactor design is herein proposed that is able to automatically culture 32 samples simultaneously. This reactor design is capable of automatic control of temperature, humidity, and culture-medium injection rate; and satisfies the interface requirements of the ISS. Since bioreactors are vulnerable to cell contamination, the medium-circulation modules were designed to be a completely replaceable, in order to reuse the bioreactor after each experiment. The bioreactor control system is designed to circulate culture media to 32 culture chambers at a maximum speed of 1 ml/min, to maintain the temperature of the reactor at $36{\pm}1^{\circ}C$, and to keep the relative humidity of the reactor above 70%. Because bubbles in the culture media negatively affect cell culture, a de-bubbler unit was provided to eliminate such bubbles. A working model of the reactor was built according to the new design, to verify its performance, and was used to perform a cell culture experiment that confirmed the feasibility of this device.

Analysis on the post-irradiation examination of the HANARO miniplate-1 irradiation test for kijang research reactor

  • Park, Jong Man;Tahk, Young Wook;Jeong, Yong Jin;Lee, Kyu Hong;Kim, Heemoon;Jung, Yang Hong;Yoo, Boung-Ok;Jin, Young Gwan;Seo, Chul Gyo;Yang, Seong Woo;Kim, Hyun Jung;Yim, Jeong Sik;Kim, Yeon Soo;Ye, Bei;Hofman, Gerard L.
    • Nuclear Engineering and Technology
    • /
    • v.49 no.5
    • /
    • pp.1044-1062
    • /
    • 2017
  • The construction project of the Kijang research reactor (KJRR), which is the second research reactor in Korea, has been launched. The KJRR was designed to use, for the first time, U-Mo fuel. Plate-type U-7 wt.% Mo/Al-5 wt.% Si, referred to as U-7Mo/Ale5Si, dispersion fuel with a uranium loading of $8.0gU/cm^3$, was selected to achieve higher fuel efficiency and performance than are possible when using $U_3Si_2/Al$ dispersion fuel. To qualify the U-Mo fuel in terms of plate geometry, the first miniplates [HANARO Miniplate (HAMP-1)], containing U-7Mo/Al-5Si dispersion fuel ($8gU/cm^3$), were fabricated at the Korea Atomic Energy Research Institute and recently irradiated at HANARO. The PIE (Post-irradiation Examination) results of the HAMP-1 irradiation test were analyzed in depth in order to verify the safe in-pile performance of the U-7Mo/Al-5Si dispersion fuel under the KJRR irradiation conditions. Nondestructive analyses included visual inspection, gamma spectrometric mapping, and two-dimensional measurements of the plate thickness and oxide thickness. Destructive PIE work was also carried out, focusing on characterization of the microstructural behavior using optical microscopy and scanning electron microscopy. Electron probe microanalysis was also used to measure the elemental concentrations in the interaction layer formed between the U-Mo kernels and the matrix. A blistering threshold test and a bending test were performed on the irradiated HAMP-1 miniplates that were saved from the destructive tests. Swelling evaluation of the U-Mo fuel was also conducted using two methods: plate thickness measurement and meat thickness measurement.

PARAMETRIC STUDIES ON THERMAL HYDRAULIC CHARACTERISTICS FOR TRANSIENT OPERATIONS OF AN INTEGRAL TYPE REACTOR

  • Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Yi, Sung-Jae;Park, Choon-Kyung;Song, Chul-Hwa;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.185-194
    • /
    • 2006
  • Transient operations for an integral type reactor, SMART-P, have been experimentally investigated using a thermal-hydraulic integral test facility, VISTA (Experimental Verification by Integral Simulation of Transients and Accidents), in order to verify the system design and performance of the SMART-P, a pilot plant of SMART. The VISTA facility was subjected to various accident conditions such as feedwater increase and decrease, loss of coolant flow, and control rod withdrawal accidents in order to elucidate the thermal-hydraulic responses following such accidents and finally to verify the system design of the SMARTP. Full functional control logics have been implemented in the VISTA facility in order to control the required control action for an accident simulation. As one of the sensitivity tests to verify the PRHRS performance, the effects of the initial water level in the compensation tank are experimentally investigated. When the initial water level is 16%, the water is quickly drained and nitrogen gas is then introduced into the PRHR system, resulting in deterioration of the PRHRS performance. It is thus found that nitrogen ingression should be prevented to ensure stable PRHRS operation.

Removal Characteristics of $SO_2$ in the Coal Combustion Flue Gas Treatment Convergence System (석탄화력발전소 현장의 석탄연소 배가스 고도처리용 건식 분류층 반응 실증장치에서의 $SO_2$ 제거성능 특성)

  • Jeon, Seong-Min;Park, Hyung-Sang;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.9 no.4
    • /
    • pp.239-246
    • /
    • 2013
  • The purpose of this study is to determine the feasibility of dry-type desulfurization process for actual application to coal-fired power plant. We used actual exhaust gas from Facility Y, Plant #2 to fabricate a demo-scale testing device to attempt to improve the efficiency of desulfurization. A spout-bed circulating dry scrubber convergence system connecting turbo reactor with bag filter was devised, then analyzed for performance characteristics of $SO_2$ removal for Ca/S mole ratio, superficial gas velocity, and ammonia injection, and for secondary reaction characteristics of the non-reactive sorbent at the bag filter. As a result, the installation of spout-bed circulating dry scrubber convergence system showed better economy and efficiency for removing sulfur than the existing wet/semidry-type desulfurization process. In addition, the best efficiency for desulfurization occurred when connected to the bag filter, with differential pressure maintained at 150 $mmH_2O$.