• 제목/요약/키워드: Korea Performance

검색결과 57,939건 처리시간 0.062초

On-site Performance Test and Simulation of a 10 RT Air Source Heat Pump

  • Baik, Young-Jin;Chang, Young-Soo;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권2호
    • /
    • pp.61-69
    • /
    • 2004
  • In this study, on-site performance test of an air source heat pump which has a rated capacity of 10 RT is carried out. Since indoor and outdoor air conditions can not be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist. To estimate the performance of the heat pump for other conditions, the heat pump is modeled with a small number of characteristic parameters. The values of the parameters are determined from the few measurements measured on-site during steady operation. A simulation program is developed to calculate cooling capacity and power consumption at any other arbitrary operating conditions. The simulation results are in good agreement with the experiment. This study provides a method of an on-site performance diagnosis of an air source heat pump.

Design of Unequal Error Protection for MIMO-OFDM Systems with Hierarchical Signal Constellations

  • Noh, Yu-Jin;Lee, Heun-Chul;Lee, Won-Jun;Lee, In-Kyu
    • Journal of Communications and Networks
    • /
    • 제9권2호
    • /
    • pp.167-176
    • /
    • 2007
  • In multimedia communication systems, efficient transmission system design should incorporate the use of matching unequal error protection (UEP), since source coders exhibit unequal bit error sensitivity. In this paper, we present UEP schemes which exploit differences in bit error protection levels in orthogonal frequency division multiplexing (OFDM) systems over frequency selective fading channels. We introduce an UEP scheme which improves the link performance with multiple transmit and receive antennas. Especially, we propose a new receiver structure based on two stage Maximum Likelihood detection (MLD) schemes which can approach the performance of a full search MLD receiver with much reduced computational complexity. In the performance analysis, we derive a generalized pairwise error probability expression for the proposed UEP schemes. Simulation results show that the proposed schemes achieve a significant performance gain over the conventional equal error protection (EEP) scheme.

공무원의 환경 적합성이 직무수행에 미치는 영향 (Effects of Person-environment Fit on the Job Performance of Public Officials)

  • 김현재;김성종
    • 한국콘텐츠학회논문지
    • /
    • 제20권8호
    • /
    • pp.559-571
    • /
    • 2020
  • 본 연구는 국회사무처 등 의정지원조직에서 개인-환경 적합성이 직무수행에 미치는 영향을 분석할 목적으로 수행되었다. 이러한 목적을 수행하기 위해 의정지원조직 공무원을 대상으로 설문조사를 실시하였고, 개인-환경 적합성(유사적합성, 보완적합성), 직무수행(과업수행, 맥락수행, 적응수행) 자기효능감을 변수로 설정하여 각각에 대한 영향요인을 구조방정식 모형 분석을 통해 규명하였다. 분석 결과 의정지원조직 공무원들의 유사 적합성은 과업수행, 맥락수행, 적응수행에서 모두 긍정적 영향을 미치는 것으로 확인되었다. 그러나 보완적합성은 과업수행, 맥락수행, 적응수행 모두에 직접적으로 영향을 미치지 않고 자기효능감을 매개로 직무수행에 영향을 미치는 것으로 나타났다. 본 연구 결과의 시사점은 의정지원조직 공무원의 직무수행도를 제고하기 위해서는 조직구성원과 직무와의 일치도를 높이는 것이 중요하다는 것을 확인해주는 한편 전공, 경력 등을 통한 부서배치 전략만으로는 성공적인 직무수행을 담보할 수 없으며 별도로 자기효능감 향상을 위한 관리가 필요하다는 것이다. 또한 본 연구에서는 의정지원조직의 교육훈련 과정에 자기효능감과 관련한 교육훈련 프로그램 도입 필요성을 제안하였다.

인젝션형 가변속 스크롤 압축기를 적용한 히트펌프의 난방성능 특성에 관한 연구 (Heating Performance Characteristics of a Heat Pump with a Variable Speed Injection Scroll Compressor)

  • 고석빈;허재혁;조일용;김용찬
    • 설비공학논문집
    • /
    • 제24권5호
    • /
    • pp.377-384
    • /
    • 2012
  • Vapor injection technique has been applied to prevent performance degrdation of a heat pump at low ambient temperatures. In this study, the heating performance of a heat pump with a variable speed injection scroll compressor using R-410A was investigated by applying sub-cooler vapor injection(SCVI) and flash tank vapor injection(FTVI). The heating performance of the heat pump was measured by varying compressor frequency and outdoor temperature. The heating capacity of the FTVI system was 8~10% higher than that of the SCVI system at all operating conditions. On the other hand, the heating performance improvement with the increase in the compressor frequency was more prominent in the SCVI system than in the FTVI system.

수소연료전지자동차의 충돌시 절연성능 평가방법에 관한 고찰 (Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle in Post Crash)

  • 이기연;길형준;김동욱;김동우;강대철
    • 한국수소및신에너지학회논문집
    • /
    • 제23권6호
    • /
    • pp.612-618
    • /
    • 2012
  • In this paper, in order to prevent electric shock of high voltage system of HFCV after crash test, insulation performance measurement methods were studied. Under conditions of in-use, insulation performance tests can be divided into measurement method using the vehicle's own RESS as DC voltage source and measurement method using DC voltage from off-vehicle sources. However, these tests can not be applied after a post-crash because parts of high voltage system cover should be removed, and insulation performance can be influenced during these tests. Therefore, we proposed post-crash insulation performance test methods for preventing electric shock through problem analysis of previous post-crash insulation performance tests. Also, test equipment which can measure voltage absence and total energy was developed. We verified performance of the equipment through experiments with vehicle test.

파랑 표류력을 고려한 선박의 파랑 중 선회성능 해석 (Numerical Analysis of Turning Performance in Waves by Considering Wave Drift Forces)

  • 서민국;남보우;김연규
    • 대한조선학회논문집
    • /
    • 제55권2호
    • /
    • pp.103-115
    • /
    • 2018
  • This paper performs a numerical computation of ship maneuvering performance in waves. For this purpose, modular-type model (MMG (Mathematical Modeling Group) model) is adopted for maneuvering simulation and wave drift force is included in the equation of maneuvering motion. In order to compute wave drift force, two different seakeeping programs are used: AdFLOW based on Wave Green function method and SWAN based on Rankine panel method. When wave drift force is calculated using SWAN program, not only ship forward speed but also ship lateral speed are considered. By doing this, effects of lateral speed on wave drift force and maneuvering performance in waves are confirmed. The developed method is validated by comparing turning test results in regular waves with existing experimental data. Sensitivities of wave drift force on maneuvering performance are, also, checked.

A Cluster-Based Energy-Efficient Routing Protocol without Location Information for Sensor Networks

  • Lee, Gil-Jae;Kong, Jong-Uk;Lee, Min-Sun;Byeon, Ok-Hwan
    • Journal of Information Processing Systems
    • /
    • 제1권1호
    • /
    • pp.49-54
    • /
    • 2005
  • With the recent advances in Micro Electro Mechanical System (MEMS) technology, low cost and low power consumption wireless micro sensor nodes have become available. However, energy-efficient routing is one of the most important key technologies in wireless sensor networks as sensor nodes are highly energy-constrained. Therefore, many researchers have proposed routing protocols for sensor networks, especially cluster-based routing protocols, which have many advantages such as reduced control messages, bandwidth re-usability, and improved power control. Some protocols use information on the locations of sensor nodes to construct clusters efficiently. However, it is rare that all sensor nodes know their positions. In this article, we propose another cluster-based routing protocol for sensor networks. This protocol does not use information concerning the locations of sensor nodes, but uses the remaining energy of sensor networks and the desirable number of cluster heads according to the circumstances of the sensor networks. From performance simulation, we found that the proposed protocol shows better performance than the low-energy adaptive clustering hierarchy (LEACH).

고집광 태양광 모듈용 냉각 장치의 열성능에 대한 수치 해석적 연구 (Numerical Investigation on the Thermal Performance of a Cooling Device for a CPV Module)

  • 도규형;김태훈;한용식
    • 한국태양에너지학회 논문집
    • /
    • 제35권1호
    • /
    • pp.1-8
    • /
    • 2015
  • In the present study, the effects of the heat spreader thickness and the heat sink size on the thermal performance of a cooling device for a concentrating photovoltaic (CPV) module were numerically investigated. Numerical simulation was conducted by using the simulation tool ICEPAK, commercial software based on the finite volume method. Numerical results were validated by comparing the existing experimental data. The thermal performance of a cooling device, which consisted of a heat spreader and a natural convective heat sink, was evaluated with varying the heat spreader thickness and the heat sink size. The geometric configuration of the natural convective heat sink, such as the fin height, the fin spacing, and the fin thickness, was optimized by using the existing correlation. The numerical results showed that the thermal performance of the cooling device increased as the heat spreader thickness or the heat sink size increased. Also, it was found that the spreading thermal resistance plays an important role in the thermal performance of the cooling device which has the localized heat source.

미사일방어체계의 교전계획 수립을 위한 요격체계의 시간성능인자 분석 (Analysis on Time Performance of Intercept System for Engagement Plan of Missile Defense System)

  • 홍승완;송진영;장영근
    • 한국군사과학기술학회지
    • /
    • 제22권1호
    • /
    • pp.93-105
    • /
    • 2019
  • In order to establish an effective engagement plan of the missile defense system, both spatial and temporal performance analysis of the intercept system should be performed. However, research on existing missile defense systems has been mainly focused on spatial performance. In this study, time performance factors are defined through the composition and operational concept of missile defense system, and the target ballistic missile interception process is presented as integrated timeline through ballistic missile model and radar model. We also proposed an algorithm for deriving time performance. Simulation results confirm that the time performance factors can be used in the engagement planning for multi-engagement through the example of engagement planning.

국내 공연장 안전관리 실태 및 개선 대책에 관한 연구 (Improving Current Status of Safety Management for Domestic Performance Theatre)

  • 갈원모
    • 대한안전경영과학회지
    • /
    • 제10권3호
    • /
    • pp.35-41
    • /
    • 2008
  • It is a fact that domestic performance art has been sharply progressed but it is focused on only performance quality technique, not on safety of performers and the audience. It is a pity that people's effort to keep safe stage environment have not traced to innovative change, eventually leading to be forced to perform under hazardous condition. This study is to find out and identify that domestic regulation and accident cases are investigated and compared with cases of advanced countries, to verify that performer and the audience are main elements to develop performance art. And it is to show more effective safety measure after pointing out hazardous elements. Research change is limited to review only performance ones of all cultural facilities and to review accident cases from these places to show reasonable safety measures for stage facilities. Operation manager covers almost all of areas such as devices, management, despite a fact that they take charge of stage facilities, illumination, sounds, already. Some conclusions are as follows; 1) performance theatre-related regulations should be established again. domestic safety standards for performance theatre safety should be established. 2) characteristic and purpose of performance place should be clarified at the stage planning and design of them 3) operation expert performance place is required to be trained to cover emergency situation at any time.