• 제목/요약/키워드: Korea Industrial Standards

검색결과 1,158건 처리시간 0.03초

크레인 안전인증기준에 대한 인간공학적 분석 및 개선 (Ergonomic Analysis and Improvement of Crane Safety Certification Standards)

  • 이용석;정기효
    • 대한안전경영과학회지
    • /
    • 제23권3호
    • /
    • pp.1-9
    • /
    • 2021
  • Crane is an important equipment for the transport of heavy goods in industrial sites, but it is also known as one of the most fatal machines. In order to reduce crane accidents, it is necessary to minimize human errors during crane operations. To achieve this, ergonomic design principles are recommended to be reflected from the crane design stage. The study analyzed the safety certification standards for crane that should be fulfilled at the crane design and manufacturing stage. This study selected five representative ergonomic design principles (feedback, compatibility, consistency, full-proof, and fail-safe) by surveying heuristic evaluation principles that are widely used for usability evaluation in early design stage. Next, the principles were applied to the safety certification standards to identify insufficient clauses. This study identified 12 insufficient clauses out of 119 in the current safety certification standards for crane and discussed their improvement directions to comply the ergonomic principles. The analysis results of this study can help of improving the safety certification standards and the method used in this study can also be applied to identify insufficient clauses in the safety certification standards for other industrial machines such as press machine and lift.

SPC관련 KS의 제개폐 및 KS A ISO 2859-3에 대한 고찰 (A Study on SPC-related KS and KS A ISO 2859-3)

  • 임재근;조병선;정수일
    • 산업경영시스템학회지
    • /
    • 제28권2호
    • /
    • pp.75-80
    • /
    • 2005
  • As a result of globalization process and TBT agreement, KS is also being revised, reestablished and some are abolished according to international standards such as ISO, IEC, etc. Conventional KS sampling inspection standards contained many different procedures from ISO, but recently, to match with international standards, all the rest of the standards except KS A 3102, 3104, 3151 were abolished, and the even the ones being in use still are also scheduled and be revised. Especially, KS A 3101, KS A 3105, KS A 3109, which were used most frequently in Korea were abolished, and the KS A ISO $2859-0\~3$ which coincide with ISO standards were established 3 years ago, but the implementation rate is very slow. Starting next year the national examination for qualification process for the product quality related item will the started and the preparation is underway. This study will investigate the recent sampling inspection process of KS as well as SPC related KS overhaul problem and present the data to help workers in SPC related field. One of the main example will be on KS A ISO 2859-3 and will attempt to help those medium and small sized companies with examples.

SIMS Study on the Diffusion of Al in Si and Si QD Layer by Heat Treatment

  • Jang, Jong Shik;Kang, Hee Jae;Kim, An Soon;Baek, Hyun Jeong;Kim, Tae Woon;Hong, Songwoung;Kim, Kyung Joong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.188.1-188.1
    • /
    • 2014
  • Aluminum is widely used as a material for electrode on silicon based devices. Especially, aluminum films are used as backside and front-side electrodes in silicon quantum dot (QD) solar cells. In this point, the diffusion of aluminum is very important for the enhancement of power conversion efficiency by improvement of contact property. Aluminum was deposited on a Si (100) wafer and a Si QD layer by ion beam sputter system with a DC ion gun. The Si QD layer was fabricated by $1100^{\circ}C$ annealing of the $SiO_2/SiO_1$ multilayer film grown by ion beam sputtering deposition. Cs ion beam with a low energy and a grazing incidence angle was used in SIMS depth profiling analysis to obtain high depth resolution. Diffusion behavior of aluminum in the Al/Si and Al/Si QD interfaces was investigated by secondary ion mass spectrometry (SIMS) as a function of heat treatment temperature. It was found that aluminum is diffused into Si substrate at $450^{\circ}C$. In this presentation, the effect of heat treatment temperature and Si nitride diffusion barrier on the diffusion of Al will be discussed.

  • PDF

KS 이행에 따른 경제적 효과에 관한 연구 (Study on economic impacts of performing Korean industrial standards(KS))

  • 이강대;고현우;이명훈
    • 산업경영시스템학회지
    • /
    • 제28권3호
    • /
    • pp.1-9
    • /
    • 2005
  • We developed the logical methods to analyze economic impacts of standardization and cleared up effects of performing KS in micro and macro aspects. This study is performed through analysing foreign studies and results from surveys. The advanced methods performing standardization as a form of 'Korean industrial standards' are suggested here, which are based on results of this study. The major consequences of this study are followings. The micro economic impact is that each company gets 604.5 millions won a year through performing KS A and F(discount rate 4.5%) and 1.46 trillions won is the macro economic impact through performing total KS A and F, which comes to 0.245% of GDP.

침의 한국산업규격(KS) 도입 필요성에 대한 고찰 (Need for Korean Industrial Standards (KS) for Acupuncture Needle)

  • 장인수;박종배;서정철
    • Journal of Acupuncture Research
    • /
    • 제21권5호
    • /
    • pp.149-162
    • /
    • 2004
  • Quality assurance with high safety profile is one of the most critical issues to medical device manufacturing. In general, this issue was not paid proper attention with respect to acupuncture needle and its related devices. Acupuncture needles are manufactured through various standards ranging from purely hand-made, partially hand-made and partially machine-made, to fully machine-made mainly in China, Korea, and Japan. There is a large difference in quality between needles from different manufacturers. In order to provide a standard manufacturing guideline, it seems necessary to make a Korean Industrial standard (KS). The authors review this topic from an historical view point, investigate the current situation of the standardization of acupuncture needles in other developed countries, and inspect the general procedure to establish a KS in Korea in order to suggest a KS for acupuncture needles.

  • PDF

산업용 저항 온도계의 저온 자동 비교 교정 시스템 개발 (Development of the automatic calibration system for industrial resistance thermometers at low temperatures)

  • 양인석;송창호;강기훈;김용규
    • 센서학회지
    • /
    • 제17권6호
    • /
    • pp.429-436
    • /
    • 2008
  • A system is designed and fabricated for the automatic low temperature calibration by comparison of industrial resistance thermometers. The cryostat is suitable for the calibration of four capsule type thermometers and four long stem thermometers. By the automatic temperature control of the cryostat, we could calibrate thermometers from $-200^{\circ}C$ to $0^{\circ}C$ for ${\sim}15$ hours by one fill of liquid nitrogen in the test run of the system. The uncertainty of the calibration for industrial platinum resistance thermometers using the automatic system is about 30mK with a 95.% confidence interval.

주방 기기 안전 기준 관련 법령 및 규격 조사 (Investigation of Laws and Standards related to Safety Criteria for Commercial Kitchen Machines)

  • 기도형;송영웅;김영호
    • 대한안전경영과학회지
    • /
    • 제19권2호
    • /
    • pp.81-93
    • /
    • 2017
  • This study aims to investigate laws and standards(including technical guidelines) related to safety criteria for 22 kitchen machines frequently used in commercial kitchens. The study was based on literature survey, interviews with charge persons in kitchen machines manufacturing companies, cafeteria providing group meals and relevant association, and web surfing. The results showed that there are two types of safety criteria such as legally forced ones by laws and optional ones by national industrial standards or technical guidelines. High pressure safety control act, safety control and business of liquefied petroleum gas act and city gas business act prescribed gas use apparatus safety criteria, rational energy utilization act did those of pressure vessel such large rotary caldron, industrial health and safety act did those of food processing machinery, and electrical appliances safety control act did those of electrical kitchen appliances. Compulsory or optional standards or guidelines related to safety criteria for kitchen machines were presented by 22 kitchen machines. Safety devices shown in the laws, standards and guidelines were also summarized by kitchen machines and their risk factors.

표준 연결망을 활용한 표준의 평가방법에 관한 연구 (A Study on the Standards Evaluation Method Using Standards Networks)

  • 최재진;정순석;김광수
    • 품질경영학회지
    • /
    • 제47권2호
    • /
    • pp.315-325
    • /
    • 2019
  • Purpose: The purpose of this study was to propose useful standards evaluation method using standards networks by analyzing the relationship between normative references citation information list. Methods: The collected data through the survey were analyzed using social network analysis. The measurement tools used for this study were divided into three dimensions such as certificate standard, normative reference and degree centrality. Results: The results of this study are as follows; regarding the influence of standard information, It is meaningful that the research using normative reference item among the bibliography information that the standard itself possesses. The analysis of social network analysis data of population standard, normative reference and the correlation analysis with sales, a variable representing actual utilization performance, suggested the importance of the standard and how to evaluate it. Conclusion: In prioritizing standard maintenance, more efficient management will be possible if centrality figures of standard network information are analyzed and used for standard maintenance.

국내 의료기기 표준 분석 및 개선에 관한 연구 (A Study on the Analysis and Improvement of Medical Device Standards in Korea)

  • 강용완;김경아
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권3호
    • /
    • pp.204-210
    • /
    • 2023
  • This study focuses on analyzing medical device standards and regulatory requirements in the medical device industry, based on the Medical Device Act in Korea. The objective of this analysis is to determine whether the domestic standards for medical devices in Korea align with international and regional standards. Furthermore, it aims to identify the current application of domestic standards in ensuring the safety and essential performance of medical devices. The analysis revealed that out of a total of 281 domestic standards, 127 standards reference international standards. In terms of the application of domestic standards to specific items, there were 473 types of instruments/machines, 30 types of medical supplies, and 45 types of dental materials. However, the level of compliance with international standards among the domestic medical device standards was only 21%. Upon detailed analysis, general and collateral standards accounted for 24%, while particular standards accounted for 19%. This indicates a significant deviation from the latest international standards. On the other hand, the level of compliance with international standards was analyzed to be 60% for particular standards and 72% for general and collateral standards in Korean industrial standards (KS). Considering these results, the disparities between domestic standards and international standards underscore the need for discussions on domestic medical device regulation and standardization. In conclusion, this study emphasizes the significance of maintaining up-to-date medical device standards and ensuring their alignment with international standards to ensure the safety and quality of medical devices. The findings highlight the necessity for further efforts to strengthen the domestic standardization system in order to promote the development of safe and high-quality medical devices.

ISO TC 298에서의 희토류 재활용 관련 국제 표준화 현황 (Standardization Status of Rare Earth Elements Recycling in ISO TC 298)

  • 이미혜;송요셉;온지선;윤승환;한문환;김범성;김택수;이빈
    • 한국분말재료학회지
    • /
    • 제29권2호
    • /
    • pp.159-165
    • /
    • 2022
  • Rare earth elements, which are important components of motors, are in high demand and thus constantly get more expensive. This tendency is driven by the growth of the electric vehicle market, as well as environmental issues associated with rare-earth metal manufacturing. TC 298 of the ISO manages standardization in the areas of rare-earth recycling, measurement, and sustainability. Korea, a resource-poor country, is working on international standardization projects that focus on recycling and encouraging the domestic adoption of international standards. ITU-T has previously issued recommendations regarding the recycling of rare-earth metals from e-waste. ISO TC 298 expands on the previous recommendations and standards for promoting the recycling industry. Recycling-related rare earth standards and drafts covered by ISO TC 298, as well as Korea's strategies, are reviewed and discussed in this article.