• Title/Summary/Keyword: Korea Design Standard

Search Result 3,774, Processing Time 0.033 seconds

The Design and Implementation of Library for RTOS Q+ (실시간 운영체제 Q+를 위한 라이브러리 설계 및 구현)

  • Kim, Do-Hyeong;Park, Seung-Min
    • The KIPS Transactions:PartD
    • /
    • v.9D no.1
    • /
    • pp.153-160
    • /
    • 2002
  • This paper describes the design and implementation of library for real-time operating system Q+, that was developed for the internet appliance. The library in the real-time operating system should be defined according to the standard interface and support the functions that are adequate to the real-time application. To ensure the compatibility between application programs, the Q+ library follows industrial and international standards, such as POSIX.1, ISO 7942 GKS. And, to support the Q+ application, library provides C standard functions, graphic/window functions, network functions, security support functions, file system functions. The Q+ library was implemented using the Q+ kernel, Digital TV set-top box, and KBUG debugging tool.

Numerical Study for the Performance Analysis and Design of a Crossflow- Type Forced Draft Cooling Tower

  • Choi, Young-Ki;Kim, Byung-Jo;Lee, Sang-Yun;Lee, Jung-Hee
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.1
    • /
    • pp.1-13
    • /
    • 2000
  • A numerical study for performance analysis of a crossflow-type forced draft cooling tower has been performed based on the finite volume method with non-orthogonal body fitted, and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy, moisture fraction, water enthalpy, and water mass balance equations are solved with Navier-Stoke's equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study. The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also performed.

  • PDF

A Study on the Characteristics of Space Programs for Senior Center in Japan (일본 노인복지센터의 공간구성 특성에 관한 연구)

  • 소준영
    • Korean Institute of Interior Design Journal
    • /
    • no.29
    • /
    • pp.153-162
    • /
    • 2001
  • This study suggests the basic data required in setting up the standard for the architectural planning of Korean senior center by analyzing the standard and current situation of a senior center in Japan that has the welfare facility system similar to that of Korea and understanding its architectural characteristics. 1) Basic spaces that constitute the senior center in Japan are meeting room, lecture room, library, multipurpose meeting room, conference room, game-recreation room, kitchen, lounge, locker room and office. ADL, kitchen, relaxing room, private bathroom, and special bathroom are needed for adult day care as establishments as an annex and work room is also required for Job training. 2) The area of a senior center is calculated in consideration of its space organization that are required as basic. For the type "A", minimum area of 1,256.42 $m^2$2 and maximum area of 2,050.56$m^2$ and for the type "B", minimum area of 812000$m^2$ and maximum area of 1,604.14$m^2$ are suggested as optimum areas. 3) The circulation planning is presented by the connected between the space organization as well as the circulation system in day care center.

  • PDF

Design and Implementation of a new XML-Signcryption scheme to protect the XML document (XML 문서 보안을 위한 새로운 XML-Signcryption scheme 설계 및 구현)

  • Han, Myung-Jin;Lee, Young-Kyung;Shin, Jung-Hwa;Rhee, Kyung-Hyung
    • The KIPS Transactions:PartC
    • /
    • v.10C no.4
    • /
    • pp.405-412
    • /
    • 2003
  • As the XML is approved standard language by the UN, the progress which complemented the XML security has being processed rapidly. In this paper, we design and implement the "XML-Signcryption" as a security mechanism to protect the XML document that can operate between other platforms. The signature and encryption which is the standard specification in W3C needs to be able to proceed them separately. Generally the signature and encryption require four times modular exponential operation, however the signcryption only needed three times modular exponential operation. This will benefit overall system effectiveness in terms of cost. And this scheme offers to convenient the user, because the signature and encryption implement as a single XML format. This tool can save the parsing time as a number of tags is few within a document. And also, in this paper, based on a research of Web Services security, we can apply XML-Signcryption to the SOAP message to provide the security services. Based on the XML-Signcryption scheme which provides confidentiality, integrity, authentication and non-repudiation to the XML document and Web Service security simultaneously.

Investigation into Electrical Characteristics of Logic Circuit Consisting of Modularized Monolithic 3D Inverter Unit Cell

  • Lee, Geun Jae;Ahn, Tae Jun;Lim, Sung Kyu;Yu, Yun Seop
    • Journal of information and communication convergence engineering
    • /
    • v.20 no.2
    • /
    • pp.137-142
    • /
    • 2022
  • Monolithic three-dimensional (M3D) logics such as M3D-NAND, M3D-NOR, M3D-buffer, M3D 2×1 multiplexer, and M3D D flip-flop, consisting of modularized M3D inverters (M3D-INVs), have been proposed. In the previous M3D logic, each M3D logic had to be designed separately for a standard cell library. The proposed M3D logic is designed by placing modularized M3D-INVs and connecting interconnects such as metal lines or monolithic inter-tier-vias between M3D-INVs. The electrical characteristics of the previous and proposed M3D logics were simulated using the technology computer-aided design and Simulation Program with Integrated Circuit Emphasis with the extracted parameters of the previously developed LETI-UTSOI MOSFET model for n- and p-type MOSFETs and the extracted external capacitances. The area, propagation delay, falling/rising times, and dynamic power consumption of the proposed M3D logic are lower than those of previous versions. Despite the larger space and lower performance of the proposed M3D logic in comparison to the previous versions, it can be easily designed with a single modularized M3D-INV and without having to design all layouts of the logic gates separately.

Wind Effects on Tall Buildings with a Porous Double-Skin Façade

  • Shengyu Tian;Cassandra Brigden;Caroline Kingsford;Gang Hu;Robert Ong;K.C.S. Kwok
    • International Journal of High-Rise Buildings
    • /
    • v.11 no.4
    • /
    • pp.265-276
    • /
    • 2022
  • Double-Skin Facades (DSF) on tall buildings are becoming increasingly common in urban environments due to their ability to provide architectural merit, passive design, acoustic control and even improved structural efficiency. This study aims to understand the effects of porous DSF on the aerodynamic characteristics of tall buildings using wind tunnel tests. High Frequency Force Balance and pressure tests were performed on the CAARC standard tall building model with a variable porous DSF on the windward face. The introduction of a porous DSF did not adversely affect the overall mean forces and moments experienced by the building, with few differences compared to the standard tall building model. There was also minimal variation between the results for the three porosities tested: 50%, 65% and 80%. The presence of a full-height porous DSF was shown to effectively reduce the mean and fluctuating wind pressure on the side face of the building by about 10%, and a porous DSF over the lower half height of the building was almost as effective. This indicates that the porous DSF could be used to reduce the design load on cladding and fixtures on the side faces of tall buildings, where most damage to facades typically occurs.

Possibility for the Replacement of Recycled Plastic Products on Timber Ginseng Cultivation Facilities (목재 인삼재배시설에 대한 재생플라스틱의 대체 가능성 평가)

  • Song, Hosung;Lim, Seong-Yoon;Kim, Yu-Yong;Yu, Seok-Cheol
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.4
    • /
    • pp.45-52
    • /
    • 2023
  • This study was conducted to examine the possibility of use as a structural material for ginseng cultivation facilities of recycled plastics. In order to determine the possibility that recycled plastic can replace timber used as a structural material for ginseng cultivation facilities, the specimens collected by elapsed time were compared with timber through bending tests. In addition, in order to analyze the effect of external environmental conditions on recycled plastic products, bending test was conducted with the specimens that had completed weathering test and accelerated heat aging test respectively. As a result, the bending strength of recycled plastic specimens with the elapsed time of 360 days was lower than that of timber. But bending strength of recycled plastic specimens exceeded the design allowable stress standard set by the Korea design standard (MOLIT, 2016). There was no degradation in quality of recycled plastic due to the external environment, and it was found that there would be no problem even if it was used as a structural material for ginseng cultivation facilities.

A Study on the Spatial Structure Change of Elderly Care Facility according to Introduction of Long-Term Care Insurance (장기요양보험제도의 도입에 따른 노인요양시설의 공간구조 변화에 관한 연구)

  • Yoon, Sohee;Kim, Suktae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.20 no.4
    • /
    • pp.67-80
    • /
    • 2014
  • Purpose : Long-term Care Insurance sets up facility standard and installation standard of aged care facilities and decides the presence of minimum number of rooms and its size in care facilities by using systematic instruments. Therefore, most aged care facilities had renovation in expansion and reconstruction following the revised regulations and even facility space structure and space composition are continuously improving. The study is to determine the purpose and trend by comparing before and after space composition of facilities which followed the implementation of Long-term Care Insurance and also to suggest hierarchical space composition suitable for aged care facilities through derived problems and to provide basic materials to plan the most appropriate facility for the aged. Methods : J-graph based on Space Syntax Theory will be schematized through in-site facility survey and before and after facility floor plan. Space composition trend will be analyzed by comparing indexes through S3 program. Results : As a result of 5 cases analysis, the following results were found; the average of whole space depth is increasing due to the Extension, the number of volunteers is decreasing and rooms for geriatric care helpers are being created due to the geriatric care helper introduction duty. Also, there are solariums being created to improve the health of the aged and dispensaries are being placed on every floor with the increase of documentary work for geriatric care helpers. With the policy implementation, care facility space composition and structure are changing with facility standard and it was analyzed that facilities were mostly put under the control of limited number of people in care room and total ground area per person. It was also found that there is increase in care space integration through before and after comparison of whole integration value. This is considered as the important result not only in facility standard satisfaction, but also in care support of geriatric care helpers and the aged, its main users. Implication : In order for elderly care facilities to have quality improvement and to develop as suitable facilities for characteristics of the aged, independent environmental facility standard preparation of elderly care facilities is needed through mutual cooperation of construction fields with regulation and policy related researches.

Evaluation of Pull-out Performance of Torsion Control Expansion Anchor According to Drill Bit Diameter (드릴비트 직경에 따른 비틀림 제어 확장 앵커의 인발성능 평가)

  • Kyoung-Hun Chae;Tae-Wo Park;Moo-Won Hur;Yeong-Seung An;Ju-Yeon Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.64-70
    • /
    • 2023
  • In this study, reliability tests of torsion control expansion anchors according to drill bit diameters were performed. The standard deviation and coefficient of variation of the anchor were reviewed through the tests for each variable, and the results were compared and evaluated with the standard test results. As a result of the reliability test of the M12 and M16 anchors with 1.04 times the drill bit diameter, they were within 20% of the ultimate tensile load permissible standard coefficient of variation. It was found that the pulling-out performance of the anchor installed in the large hole was sufficiently secured. However, it was found to be about 253% and 210% of the design strength, indicating that the pulling performance of the anchor installed in 1.04 times the drill bit diameter was sufficiently secured. As a result of the reliability test of the M12 and M16 anchors with 1.02 times the drill bit diameter, the value of the coefficient of variation of the ultimate tensile load limit was within 20%, which satisfies the test standard. It was shown to be about 136% and 168% of the design strength, indicating that the pulling-out performance of the anchor installed in 1.02 times the drill bit diameter is sufficiently secured.

Parametric Study on design Variables of Rectangular Concrete Filled Tubular Columns with High-Strength Steel (유한요소해석에 의한 고강도 강재를 사용한 각형 콘크리트 충전 강관 기둥의 설계인자 분석)

  • Choi, Hyun-Ki;Bae, Baek-Il;Choi, Yun-Cheol;Choi, Chang-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.2
    • /
    • pp.10-21
    • /
    • 2015
  • For the safe design of steel-concrete composite structure, usable yield strength of steels are limited in most of design standard. However, this limitation sometimes cause the uneconomical design for some kind of members such as slender columns which was affected by elastic buckling load. For the economical design for slender columns, parametric study of RCFT (Rectangular CFT) with high-strength steel is conducted, especially investigating the limitation of yield strength of high-strength steels. Using ABAQUS, finite element analysis program, the finite element model was constructed and calibrated with experimental study for RCFT with high strength steel which have yield strength up to 680MPa. Investigated design parameters are yield strength of steel, compressive strength of concrete, steel thickness and slenderness ratio. The effect of design parameters were compared with design standard, KBC-09. From the parametric study with 54 models and previous test specimens, RCFT can be safely design with higher yield strength of steels than currently limited by KBC for large range of slenderness ratio.