• Title/Summary/Keyword: Kobe 지진

Search Result 67, Processing Time 0.026 seconds

A Comparative Analysis of Korea-Japan Seismic Recovery System (한일 지진 복구체계의 비교 분석)

  • Lee, JunBeom
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.3
    • /
    • pp.458-471
    • /
    • 2020
  • Purpose: In Korea, the frequency and frequency of earthquakes are increasing every year. Therefore, the purpose of this study was to compare and analyze the characteristics and examples of earthquakes in Korea and Japan, and to propose improvements to the earthquake prevention policy in Korea. Method: In this study, we investigate and evaluate Japan's response in two cases: the Kobe earthquake and the East Japan earthquake. After surveying and evaluating the nation's countermeasures in the two events, Gyeongju and Pohang, they were compared. Result: When comparing recovery systems in Korea and Japan, there were significant differences in plans for restoration of road transport networks, regional disaster prevention plans, and the introduction of Conclusion: considering the physical distance between Korea's earthquake-prone areas and the capital, the government should quickly come up with countermeasures to ensure that immediate earthquake response in the region is enhanced through the detailed establishment of the Functional Continuity Plan (COOP), and that administrative functions will function normally in the event of a disaster through the introduction of the administrative BCP concept.

Survey for Damage and Recovery of Communication Networks in Kobe's Earthquake (일본 고베 지진시의 통신망 피해 및 복구 현황 분석)

  • Song, Y.J.;Lee, J.W.;Lee, J.H.
    • Electronics and Telecommunications Trends
    • /
    • v.10 no.3 s.37
    • /
    • pp.57-67
    • /
    • 1995
  • 정보화 사회의 하부구조로서 중요성이 증대되고 있는 정보통신망은 단절없이 항상 안정적인 통신 서비스를 제공하기 위하여 비상재난을 대비한 통신망의 안전성 및 신뢰성을 확보하는 것이 중요하다. 본 고에서는 '95년 1월에 발생한 일본 고베 지방의 대지진으로 인한 정보통신 및 방송 분야의 피해 현황과 복구 대책을 살펴본다.

Seismic Response Analysis at Multi-Layered Ground (다층지반의 지진응답해석)

  • Kim, Yong-Seong;Lee, Dal-Won
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.329-332
    • /
    • 2002
  • In the present study, in order to apply a cyclic viscoelastic-viscoplastic constitutive model to multi-layered ground conditions during large earthquake, the numerical simulations of the 1995 Hyogoken Nanbu Earthquake at Port Island, Kobe, Japan, were performed by the seismic respons analysis. From the seismic response analysis, it was verified that a cyclic viscoelastic-viscoplastic constitutive model can give a good description of the damping characteristics of clay accurately during large event which induces plastic deformation in large strain range.

  • PDF

Seismic Performance-Based Design for Breakwater (방파제의 성능기반 내진설계법)

  • Kim, Young-Jun;Park, Inn-Joon
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.12
    • /
    • pp.91-101
    • /
    • 2022
  • The 1995 Kobe earthquake caused a massive damage to the Port of Kobe. Therefore, it was pointed out that it was impossible to design port structures for Level II (Mw 6.5) earthquakes with quasi-static analysis and Allowable Stress Design methods. In Japan and the United States, where earthquakes are frequent, the most advanced design standards for port facilities are introduced and applied, and the existing seismic design standards have been converted to performance-based design. Since 1999, the Korean Port Seismic Design Act has established a definition of necessary facilities and seismic grades through research on facilities that require seismic design and their seismic grades. It has also established a performance-based seismic design method based on experimental verification. In the performance-based seismic design method of the breakwater proposed in this study, the acceleration time history on the surface of the original ground was subjected to a fast Fourier transform, followed by a filter processing that corrected the frequency characteristics corresponding to the maximum allowable displacement with respect to performance level of the breakwater and the filtered spectrum. The horizontal seismic coefficient for the equivalent static analysis considering the displacement was calculated by inversely transforming (i.e., subjected to an inverse fast Fourier transform) into the acceleration time history and obtaining the maximum acceleration value. In addition, experiments and numerical analysis were performed to verify the performance-based seismic design method of breakwaters suitable for domestic earthquake levels.

Seismic Performance Evaluation of Existing RC Bridge Piers by Pseudo Dynamic Test (유사동적 실험에 의한 기존 RC 교각의 내진성능 평가)

  • 박종협
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.364-371
    • /
    • 2000
  • The pseudo dynamic test has been carried out so as to investigate the seismic performance of RC bridge piers strengthened with and without glass fiber sheets. The Lessons from severe demage of many infrastructures in Kobe(1995) and Northridge(1996) earthquakes have emphasized the need to develop the retrofit measures to enhance flexural strength, ductility and shear strength of RC bridge piers nonseismically designed before 1992. Therefore, the objective of this experimental research is to investigate the seismic behavior of circular reinforced concrete bridge piers by the pseudo dynamic test. and then to enhance the ductility of concrete piers strengthening with glass fiber sheets in the plastic hinge region. 7 circular RC bridge piers were made in a 1/3.4 scale. Important test parameters are confinement steel ratio, retrofitting. load pattern, etc. The seismic behavior of circular concrete piers under artificial ground motions has been evaluated through strength and stiffness degradation, energy dissipation. It can be concluded that existing bridge piers wrapped with glass fibers in the plastic hinge regions could have enough seismic performance.

  • PDF

Application of Seismic Isolation Technique in Residential-Commercial Building (주상복합건물에 대한 면진기술의 적용)

  • 이동근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.465-472
    • /
    • 2000
  • Seismic isolation technique has been applied mainly in low rise buildings and its seismic performance was satisfactory during Kobe Earthquake. However, in the case of medium and/or high-rise buildings, mid-story isolation could be more technically feasible than base isolation to reduce earthquake forces. In this paper, the seismic effectiveness of mid-story isolation in medium and/or high-rise shear building as well as low rise shear building was evaluated analytically. After verifying the effectiveness of mid-story isolation technique, this method also applied in residential-commercial building. It was found that mid-story isolation, that is isolation between upper residential area and lower commercial area, could reduce inter-story drift and floor shear forces comparing to the conventional fixed base.

  • PDF

Applicability of Similitude Law for 1-g shaking table tests (1-g 진동대 모형시험에서의 상사법칙 적용성 평가)

  • 황재익;김성렬;이용재;김명모
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.75-82
    • /
    • 2002
  • Shaking table model tests are performed to reproduce the dynamic behavior of a gravity quay wall and a pile-supported wharf damaged by Kobe earthquake in 1995. Using the scaling relations suggested by Scott and Iai(1989), the results of the model tests are compared with field measurements as well as with those of the model tests previously executed. The displacements of the gravity quay wall predicted by the current model tests are, at most, one third of the measured displacements, while the displacements of the model pile-supported wharf are about two thirds of the measured values. One possibility for the discrepancy is speculated to be the use of too big scaling factor, i.e., too small size of model.

  • PDF

The Seismic Performance for Concrete-filled Steel Piers (콘크리트 충전 강교각의 내진 성능)

  • 정지만;장승필;인성빈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.189-196
    • /
    • 2002
  • The capacity of CFS piers has not been used to a practical design, because there is no guide of a seismic design for CFS piers. Therefore, the guide of a seismic design value is derived from tests of CFS piers in order to apply it to a practical seismic design. Steel piers and concrete-filled steel piers are tested with constant axial load using quasi-static cyclic lateral load to check ductile capacity and using the real Kobe ground motion of pseudo-dynamic test to verify seismic performance. The results prove that CFS piers have more satisfactory ductility and strength than steel piers and relatively large hysteretic damping in dynamic behaviors. The seismic performance of steel and CFS piers is quantified on the basis of the test results. These results are evaluated through comparison of both the response modification factor method by elastic response spectrum and the performance-based design method by capacity spectrum and demand spectrum using effective viscous damping. The response modification factor of CFS piers is presented to apply in seismic design on a basis of this evaluation for a seismic performance.

  • PDF

A Study on the Seismic Performance of MR Fluid Dampers in Base-Isolated Structures (기초격리된 구조물에서 자기유동성 유체감쇠기의 면진성능에 관한 연구)

  • 이종세;도학용
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.371-378
    • /
    • 2002
  • The design concepts using vibration reduction techniques, or structural control, have been proposed recently to protect infrastructure against earthquakes. The magnetorheological(MR) fluid damper is one of the most promising new devices for structural vibration reduction because of its mechanical simplicity, high dynamic range, low power requirement, large force capacity and robustness. In this study, the seismic performance of MR devices are compared with that of NZ systems as an attempt to provide some data for improving seismic design techniques applied to structures. For nonlinear time domain analysis of a base isolation system, a six-story building model is considered as a numerical example. The ground acceleration data of El Centre 1940, Mexico City 1985 and Kobe 1995 earthquakes are used as seismic excitations. The results show that MR damper systems for outperform NZ systems in wide-ranging seismic excitations with respect to intensity and period characteristics.

  • PDF

comparative Study on confinement Steel Amount of RC Column Bent (철근콘크리트 교각 심부구속철근량의 비교연구)

  • 이재훈
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.239-246
    • /
    • 1999
  • recently there have been many destructive seismic events in Kobe Japan in 1995 and in Northridge California USA in 1994. etc. The Korean Bridge Design Standard Specifications adopted the seismic design requirements in 1992. Comparing the earthquake magnitude in Korea with those in the west coast of the USA it may be said that the current seismic design requirements of the Korean Bridge Design Standard Specifications provides too conservation design results especially for transverse reinforcement details and amount in reinforced concrete columns. This fact usually makes construction problems in concrete casting due to transverse reinforcement congestion. And the effective stiffness Ieff depends on the axial load P(Ag{{{{ {f }_{ck } }}) and the longitudinal reinforcement ratio Ast/Ag and it is conservative to use the effective stiffness Ieff than the gross section moment Ig. Seismic design for transverse reinforcement content of concrete column is considered of extreme-fiber compression strain R-factor axial load and stiffness etc.

  • PDF