• Title/Summary/Keyword: Knee points

Search Result 146, Processing Time 0.046 seconds

Real-time Location Tracking Analysis of Cross-country Skiing using Various Wearable Devices: A Case Study (다양한 웨어러블 디바이스를 활용한 크로스컨트리스키 실시간 위치 추적: 사례 연구)

  • Hwang, Jinny;Kim, Jinhae;Kim, Hyeyoung;Moon, Jeheon;Lee, Jusung;Kim, Jinhyeok
    • Korean Journal of Applied Biomechanics
    • /
    • v.29 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • Objective: The purpose of this study was to confirm that the cross-country ski sprint course in PyeongChang, where the 2018 Winter Olympics course was to utilize wearable devices equipped with inertial measurement unit (IMU), global positioning system (GPS) and heart rates sensor. Method: For the data collection, two national level cross-country (XC) skiers performed classic technique on the entire sprint course. We analyzed cycle characteristics, range of motion on double poling (DP) technique, average velocity, and displacement of 3 points according to the terrain. Results: The absolute cycle time gradually decreased during starting, middle and finish sections. While the length of the DP increased and the heart rates tended to increase for men skier. In addition, the results indicated that range of motion of knee joint during starting and finish section decreased more than middle section. The errors of latitude and longitude data collected through GPS were within 3 m from 3 points. Conclusion: Through the first case study in Korea, which analyzed the location and condition of XC skiers in the entire sprint course in real time, confirmed that feedback was available in the field using various wearable sensors.

Posterior Cruciate Ligament Reconstruction by Tibial Inlay Technique (Tibial Inlay 방법을 이용한 후방 십자 인대 재건술의 결과)

  • Song Eun Kyoo;Yoon Taek Rim;Jung Jong Wook;Kim Jong Seon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.80-84
    • /
    • 2001
  • Purpose : To evaluate the clinical and radiological results of posterior cruciate ligament reconstruction(PCL) by tibial inlay technique. Materials and Methods : Twenty four patients(25 cases), who underwent reconstruction of posterior cruciate ligament by tibial inlay technique and were followed up for at least 2 years, were reviewed retrospectively. Mean age at operation was 35 years and mean period of follow up was 34 months. Clinically Lysholm knee socre, posterior drawer test and step off sign were evaluated. Instrumented posterior laxity test with $Telos^{\circledR}$ device(Telos stress device; Austin & Associates, Inc., Polston, US) was performed. Results : Lysholm knee score was improved from 56.9 points preoperatively to 94.6 points at fellow up. Posterior drawer test showed grade II instability in 1 case, grade III in 18 and Grade IV in 6 preoperatively and improved to grade I In 12, grade II in 10 and grade III in 3 at follow up. Step off signs were changed from -10mm in 6 cases, -5mm in 18 and flush in 1 preoperatively to -5mm in 3, flush in 10 and +5mm in 12 at follow up. Side to side difference of instrumented posterior laxity test was improved front 13.6mm preoperatively to 4.3mm at follow up. Conclusions : PCL reconstruction by tibial inlay technique is considered to be a good treatment method to restore posterior stability of the knee, which could result in satisfactory clinical and radiological results at more than 2 years' follow up.

  • PDF

Basic Study on the Development of Impact Protective Pants and Falls of Elderly Women (여성노인의 낙상실태 및 충격보호팬츠 개발을 위한 기초 연구)

  • Lee, Jin Suk;Park, Jung Hyun;Lee, Jeong Ran
    • Fashion & Textile Research Journal
    • /
    • v.16 no.6
    • /
    • pp.945-953
    • /
    • 2014
  • This study aims to develop protective pants to relieve impact from falls and to present basic data for the development. The survey results are as follows; First, 45% of the respondents were in their 60s and 55% of them were in their over 70s and older. Also, 64% of them have fallen once for the past year and 36% of them have fallen twice or more. The older they were, the more there were those who have fallen twice or more. This indicated the older people has experienced more fall accidents again after a initial fall accident. Second, as per accident situations, the survey showed that fall accidents happened the most in the winter and in the afternoon (12-18 pm). Also, it happened on a street mostly and they were wearing sneakers or hiking boots when they got a hurt slipped in a front or side by missing their step in a walk. The injury areas are mostly knee and ankle. They had the bruises or a sprain in their knee and ankle mostly. The rate of bone fracture was 19.5%. Therefore, the protection area to falls in lower body is the knee. But hip and hip joint should be protected with knee as well because those are usually be broken when it is damaged. Third, approximately 80% of those who were hospitalized for treatment had surgery. Patients who had surgery were rather in their over 70s than in their 60s. The older they were, the more serious their fracture was. The period of hospital or outpatient treatment is more than three weeks in many cases. They responded their health got worse after falls. Aftereffects of accidents were physical discomfort, anxiety and medical costs. Falls to the old makes physical damage, psychological damage, which cause reduced physical activity and the increased cost of health care with economic losses. So it results on a negative impact on the life of the old. Fourth, elderly females were rarely aware of impact protective clothing and they have never purchased such clothing. For impact protective pants, the major consideration was suitable design for their body types. They liked casual style with front or side pockets and simple designs without any patterns or decorations. As per pants materials, they responded that they need functionality, activity and elasticity. Among the functional points, insulation of cloths are considered importantly, so the heat reservance of material in the impact protective pants should be considered carefully.

Three Dimensional Curvature Analysis of Femoral Shaft Bowing based on CT Images (CT 영상을 이용한 대퇴체부 휨의 3차원적 곡률 분석)

  • Lim, Ki Seon;Oh, Wang Kyun;Lee, Tae Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.5
    • /
    • pp.313-320
    • /
    • 2013
  • For some patients with joint illnesses such as rheumarthritis or varus deformity, the total knee arthroplasty (TKA) procedures are performed. However, when inserting metal cutting guide for the procedures, due to the femoral shaft bowing, complications such as the cortex of the femoral shaft damages or secondary fractures can be caused. If the central coordinate value of the femoral shaft is known, the metal cutting guide could be inserted into the anatomical center, so such complications can be prevented. In this study, CT images of femoral shafts of 10 individuals in the experiment group who are in need of receiving the total knee arthroplasty procedures and those of 10 individuals in the control group without illness in the femoral shaft have been utilized to locate the 3-dimensional coordinate values. Then, Matlab was utilized to identify the central coordinate value in order to obtain a graph reflecting the anatomical shapes as well as to acquire the 3-dimensional radial curvature values by section. As a result, the average curvature range and standard deviation of femoral shafts of the experiment group was determined to be $758.15{\pm}206.3mm$ whereas the that of the control group was determined to be $1672.97{\pm}395.6mm$. The statistical significance of the measured results was verified through f-distribution analysis. Based on these results, it was verified that the level of curvature of the femoral shaft of the experiment group was higher. If the anatomical central points are located and analyzed using this methodology, it would be helpful in performing orthopedic operations such as the total knee arthroplasty.

Surgical Outcome of Primary Repair in Anterior Cruciate Ligament Rupture - Minimum 4-years follow-up - (전방 십자 인대 봉합술의 수술적 치료 - 최소 4년 이상 추시 결과 -)

  • Byun, Ki-Yong;Rhee, Kwang-Jin;Lee, Suk-Joon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.123-127
    • /
    • 2000
  • Purpose : To evaluate of the surgical outcome of primary repair in anterior cruciate ligament rupture. Material & Method : Twenty-five patients underwent arthroscopic primary repair of ACL. We performed pull-out suture of ruptured ligament in 18 cases, and suture and augumentation with gracillis & semitendinosus in 7 cases. At follow up, the International Knee Documentation Committee(IKDC) scale & Lysholm score were used to grade outcome, and also the KT-2000 arthrometer was used to evaluate objective ligament laxity. Results : In analysis of IKDC scale, final evaluation group were group A in 3 cases, group B in 13 cases, group C in 9 cases. The mean value of Lysholm score was 83 points. In KT-2000 arthrometer examination, mean anterior translation was 3.9mm at 201b, 7.3mm at 30lb. The mean difference value between injured knee and uninjured knee was 1.1mm at 201b, 2.29mm at 301b. There was statistical significance in mean difference value between injured and uninjured knee. Conclusion : By analysis of clinical & objective data, we could confirm that the mid-term result of ACL suture is not satisfactory. So, we recommend that ACL reconstruction would be done in young active patient rather than suture.

  • PDF

Correction of Dose Distribution at Total Body Irradiation using Compensator

  • Kim Jong Sik;Cho Hyun Sang;Kim Young Kon;Cho Jung Keun;Ju Sang Kyu;Park Young Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.9 no.1
    • /
    • pp.87-93
    • /
    • 1997
  • The using of compensator is required to adjust the irregular dose distribution due to irregular thickness of the body in Total Body Irradiation. Aluminuim, copper or lead is generally used as compensator. In our study, we would like to introduce a result of the attenuation and compensation effect of radiation use compensator made by duralumin and its clinical use. The thickness of compensator was calculated by the attenustion of radiation, which was measured by polystyrene phantom and ionization chamber(farmer). The compensation effect of radiation was measured by diode detector. All of conditions were set as in real treatment, and the distanc from source to detector was 446 cm. We also made fixation of device to easily attach the compensator to LINAC. Beam spoiler was menufactured and placed on the patient to irradiate sufficient dose to the skin. diode detector were placed on head, neck, chest, umbilicus. pelvis and knee with each their entranced exit points, and datas of dose distribution were evaluated and compared in each points for eleven patients(Feb. 96-Feb. 97). The attenuation rate of irradiation by duralumin compensator was measured as $1.4\%$ in 2mm thickness. The mean attenuation rate was $1.3\%$ per 2mm as increasing the thickness gradually to 50 mm. By using duralunim compensator, dose distribution in each points of body was measured with ${\pm}2.8\%$ by diode detectior. We could easily calculate the thickness of compensator by measuring the attenuation rate of radiation, remarkably reduce the irragularity of dose distribution duo to the thickness of body and magnify the effect of radiation therapy.

  • PDF

Survey on Fibromyalgia Syndrome (섬유조직염 환자에 대한 기초 조사연구)

  • Han, Sang-Sook;Kang, Hyun-Sook
    • Journal of muscle and joint health
    • /
    • v.4 no.1
    • /
    • pp.74-86
    • /
    • 1997
  • This investigation has been conducted based on the medical chart of 344 patients who have been diagnosed of fibromyalgia syndrome during Oct. 9, 1996 through Nov. 20 at the Rheumatism Hospital of H. University located in Seoul. 280 which have been included in the analysis. 1. Only one patient was male in 280 patients, age distribution was from 28 to 76, in which the average age was 52.4. 2. Percentage of treatment duration was 6 months in 46.1%, 3 years in 22.1% and 2 years in 12.5%. Considering these results, it can be predicted that the number of patients might be increased and accumulated in the future. 3. Percentage of patients having primary fibromyalgia syndrome was 39.3%, having combination with osteoarthritis was 36.7% and the rest case have combination with rheumatoid arthritis at the same time. 4. The percentage of cases having patients 10-12 tender points was 37.1%, while the most of cases have pain at 12-19 tender points. The common locations of the tender point were at lateral epicondyle of elbow in 92.0%, at midpoint of upper border Trapezius in 84.8%, at upper part of scapula Supraspinatus in 82.9%, at medial fat pad proximal to the joint line knee in 81.85%, at intertransverse of $C_{5-7}$ Low cervical in 73.4% and at 2nd distal costochondral Junction 2nd rib in 72.0%. And most of the patients had joint functional disability at all in 47.1% with average 2.41 joint functional disability. 5. Age was not a variable influencing the number of tender points and the number of joint functional disability.

  • PDF

A Study on the Inverse Kinematics for a Biped Robot (2족 보행 로봇의 역기구학에 관한 연구)

  • 성영휘
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.12
    • /
    • pp.1026-1032
    • /
    • 2003
  • A biped walking robot which is developed as a platform for researching walking algorithm is briefly introduced. The developed walking robot has 6 degrees of freedom per one leg. The origins of the last three axis do not intersect at a point, so the kinematic analysis is cubmersome with the conventional method. In the former version of the robot, Jacobian-based inverse kinematics method is used. However, the Jacobian-based inverse kinematics method has drawbacks for the application in which knee is fully extended such as stair-case walking. The reason far that is the Jacobian becomes ill-conditioned near the singular points and the method is not able to give adequate solutions. So, a method for giving a closed-form inverse kinematics solution is proposed. The proposed method is based on careful consideration of the kinematic structure of the biped walking robot.

Development of an Automatic Excitation Characteristics Measurement System of the Protective Relaying CT (보호계전기용 CT의 여자특성 자동측정 시스템 개발)

  • Kwon, Sung-Won;Kim, Mun-Seog;Kim, Jae-Young;Lee, Sung-Ha;Jung, Jae-Kap
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.868-869
    • /
    • 2008
  • An automatic excitation characteristics measurement system for the protective relaying current transformer(CT) with accuracy of about 1 % has been developed. The system can be used up to 2 kV and 10 A at power frequency. The developed system can calculate the voltage and current at knee points of $30^{\circ}$ and $45^{\circ}$ tangents in accordance with IEEE standard by the interpolation in log scale. The excitation curve of the CT is plotted in auto-scale simultaneously with measuring rms voltage and current at the secondary of the CT.

  • PDF

Acupuncture stimulation for motor cortex activities: Evidence from 3T functional MRI study

  • 최보영;전신수;유승식;최기순;박상동;임은철;정성택;이형구;서태석
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.85-85
    • /
    • 2003
  • Purpose: To investigate whether or not acupuncture of GB34 produces a significant response of the modulation of somatomotor areas by functional magnetic resonance imaging (fMRI) study. Materials and methods: The acupoint, GB34, located in the back of the knee, is known to be effective in recovering motor function after stroke. Using 3T MRI scanner, functional MR imaging of the whole brain was peformed in 12 normal healthy subjects during two stimulation paradigms; acupuncture manipulation on GB34 and sham points. This study investigates the activation of the motor cortex elicited by a soft and an intensified stimulation of GB 34.Three different paradigms were carried out to detect any possible modulation of the Blood Oxygenation Level Dependent (BOLD) response in the somatomortor area to motor stimulation through acupuncture.

  • PDF