• Title/Summary/Keyword: Knee points

Search Result 146, Processing Time 0.032 seconds

A Kinetics Analysis of Forward 11/2 Somersault on the Platform Diving (플랫폼 다이빙 앞으로 서서 앞으로 11/2회전 동작의 운동역학적 분석)

  • Jeon, Kyoung-Kyu
    • Korean Journal of Applied Biomechanics
    • /
    • v.23 no.3
    • /
    • pp.209-218
    • /
    • 2013
  • This study was to perform the kinetic analysis of forward $1\frac{1}{2}$ somersault on the platform diving. Six men's diving players of the Korea national reserve athletes participated in this study. The variables were analyzed response time, velocity, center of mass (COM), angle, center of pressure (COP) and ground reaction force (GRF) of motion. For measure and analysis of this study, used to synchronized to 4 camcorder and 1 force plate, used to the Kwon3D XP (Ver. 4.0, Visol, Korea) and Kwon GRF (Ver. 2.0, Visol, Korea) for analyzed of variables. The results were as follows; Time factor were observed in maximum knee flexion depending on the extent of use at phase 1 of take-off to execute the somersault. This enabled the subject to secure the highest possible body position in space at the moment of jumping to execute the somersault and prepare for the entry into the water with more ease. Regarding the displacement of COM, all subjects showed rightward movement in the lateral displacement during technical execution. Changes in forward and downward movements were observed in the horizontal and vertical displacements, respectively. In terms of angular shift, the shoulder joint angle tended to decrease on average, and the elbow joints showed gradually increasing angles. This finding can be explained by the shift of the coordinate points of body segments around the rotational axis in order to execute the half-bending movement that can be implemented by pulling the lower limb segments toward the trunk using the upper limb segments. The hip joint angles gradually decreased; this accelerated the rotational movement by narrowing the distance to the trunk. Movement-specific shifts in the COP occurred in the front of and vertical directions. Regarding the changes in GRF, which is influenced by the strong compressive load exerted by the supporting feet, efficient aerial movements were executed through a vertical jump, with no energy lost to the lateral GRF.

Slacks Pattern Development for Chinese Males in Their 20s (중국 20대 남성의 슬랙스 패턴 개발)

  • Lee, So-Young;Shim, Boo-Ja
    • Journal of Fashion Business
    • /
    • v.12 no.1
    • /
    • pp.93-108
    • /
    • 2008
  • This study held physical measurement for male subjects in their 20s living in Ningbo City, Zhejiang Province in China, showing the biggest market in men's clothes. Their representative lower body types with average shapes and sizes were chosen so as to develop men's slacks patterns with better dimension fitness. The following are the results of the analysis: 1. Slacks patterns were made based on the mean measurement values of 5 people, who were closest to the representative body types, from the index*absolute group of 47 people. The dimensions of application for slacks pattern-making were 77cm(omphalion waist circumference), 91cm(hip circumference), and 103cm(slacks length). 2. For the comparison of high-fitness and more-room pattern dimensions, 5 styles of slacks were made: Korean, Chinese, British, Japanese, and industrial. In the dressing fitness tests, industrial patterns had excellent appearance and Japanese ones had the best function. 3. Based on the analysis results of slacks pattern comparison, the target slacks were experimentally made and received superior evaluation points to the compared slacks patterns in two times of evaluation for appearance and function. 4. The final slacks pattern in this research had the following dimensions: front waist circumference: W(1-2cm with room included)/4-1cm, back waist circumference: W/4+1cm, front hip circumference: H(9$\sim$10cm with room included)/4-1cm, back hip circumference: H/4+1cm, crotch length: H/4-1.5cm, hip length: crotch length-H/12, front crotch extension: H/16-1.5cm, back crotch extension: H/8+3cm, knee line: 33cm below crotch line, front tuck amount: 4cm, back dart amount: 2.5cm(center) and 1.5cm(side), and back dart length: 10cm (center) and 6cm(side).

A Case of Korean Medicine Treatments Including Chuna Therapy in Lower Extremity Weakness and Gait Disturbance Due to Lumbar Disk Herniation and Spinal Stenosis (요추 추간판 탈출증 및 척추관 협착으로 인한 하지 근력 저하 및 보행 장애 환자에 대한 추나요법을 포함한 한방복합치료 치험 1예)

  • Jung, Su-Eun;Park, Song-Mi;Cho, Sung-Woo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.31 no.2
    • /
    • pp.99-108
    • /
    • 2021
  • The study reports the clinical case of a patient with lower extremity weakness and gait disturbance treated with Korean medicine treatments including Chuna therapy. The patient suffered lower extremity weakness and gait disturbance with diagnosis of lumbar disk herniation and spinal stenosis. As a treatment, the doctor applied Chuna therapy, herbal medicine, acupuncture, pharmacopuncture, cupping and moxa. The effect of treatment was evaluated by numeral rating scale (NRS), self-walkable distance, functional independence measure (FIM), Oswestry disability index (ODI) and manual muscle test (MMT). NRS decreased from 6 to 4 at the leg. Self-walkable distance increased from 0 m to 10 m, FIM increased 85 to 96 points while ODI decreased 64% to 54%. MMT of hip flex and knee extension improved from grade 3+, grade 3 to grade 4, respectively. Korean medicine treatment can be effective for patients who suffer lower extremity weakness and gait disturbance due to lumbar disk herniation and spinal stenosis. Further clinical studies are required to verify these findings.

Development and feasibility test of sit-to-stand transfer assistive device

  • Ha, SinHo;Jeong, SeYeon;Hong, SoungKyun;Choi, Wonjae;Lee, Kwangkook;Park, Donghwan;Son, SangJun;Shin, HyeonHui;Lee, GyuChang
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.1
    • /
    • pp.41-46
    • /
    • 2022
  • Background: The purpose of this study was to develop a sit-to-stand transfer assistive device, and to conduct a feasibility test. Design: A technical note. Methods and results: In this study, we developed a sit-to-stand transfer assistive device for the elderly and the disabled who have difficulty standing up independently from sitting positions. The sit-to-stand transfer assistive device allows the user to transfer the weight from a sitting position to a standing position while shifting the weight forward by grabbing and pulling a support stand. Ten healthy adults participated in the feasibility test of the device. Each participant used the developed sit-to-stand transfer assistive device and investigated supplementation through a brief interview. As a result of the feasibility test, the opinion was that the device could assist the sit-to-stand transfer to some extent. There were opinions that it needed a function to adjust the height of the knee protective plate in the sitting position according to the user's physical characteristics. Because of the inconvenience of operating the lock device for fixing the position and adjusting inclination, there was an opinion that the improvement for a locking device is needed. There were opinions that it would be better to reduce the size of the device due to its inconvenience of portability. Conclusion: In this study, we developed the sit-to-stand transfer assistive device for the elderly and the disabled who have difficulty standing up independently from sitting positions. In addition, it is considered that the upgrade of the device is necessary for the future since there are supplementary opinions on some points.

Development of Bib Pants Design and Pattern for Cycling Smart Wear (사이클링 스마트웨어 제작을 위한 빕 팬츠 디자인 및 패턴 개발)

  • Yunyoung, Kim;Byeongha, Ryu;Woojae, Lee;Kikwang, Lee;Rira, Kim
    • Journal of Fashion Business
    • /
    • v.26 no.5
    • /
    • pp.91-104
    • /
    • 2022
  • In this study, a cycling smart wear for measuring cycling posture and motion was developed using a three-dimensional motion analysis camera and an IMU inertial sensor. Results were compared according to parts to derive the optimal smart device attachment location, enabling correct posture measurement and cycle motion analysis to design a pattern. Conclusions were as follows: 1) 'S-T8' > 'S-T10' > 'S-L4' was the most significant area for each lumbar spine using a 3D motion analysis system with representative posture change (90°, 60°, 30°) to derive incisions and size specifications; 2) the part with the smallest relative angle change among significant section reference points during pattern design was applied as a reference point for attaching a cycling smart device to secure detachable safety of the device. Optimal locations for attaching the cycling device were the "S-L4" hip bone (Sacrum) and lumbar spine No. 4 (Lumbar 4th); 3) the most suitable sensor attachment location for monitoring knee induction-abduction was the anatomical location of the rectus femoris; 4) a cycling smart wear pattern was developed without incision in the part where the sensor and electrode passed. The wearing was confirmed with 3D CLO. This study aims to provide basic research on exercise analysis smart wear, to expand the smart cycling area that could only be realized with smart devices and smart watches attached to current cycles, and to provide an opportunity to commercialize it as cycling smart wear.

Markerless Motion Capture Algorithm for Lizard Biomimetics (소형 도마뱀 운동 분석을 위한 마커리스 모션 캡쳐 알고리즘)

  • Kim, Chang Hoi;Kim, Tae Won;Shin, Ho Cheol;Lee, Heung Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.136-143
    • /
    • 2013
  • In this paper, a algorithm to find joints of a small animal like a lizard from the multiple-view silhouette images is presented. The proposed algorithm is able to calculate the 3D coordinates so that the locomotion of the lizard is markerlessly reconstructed. The silhouette images of the lizard was obtained by a adaptive threshold algorithm. The skeleton image of the silhouette image was obtained by Zhang-Suen method. The back-bone line, head and tail point were detected with the A* search algorithm and the elimination of the ortho-diagonal connection algorithm. Shoulder joints and hip joints of a lizard were found by $3{\times}3$ masking of the thicked back-bone line. Foot points were obtained by morphology calculation. Finally elbow and knee joint were calculated by the ortho distance from the lines of foot points and shoulder/hip joint. The performance of the suggested algorithm was evaluated through the experiment of detecting joints of a small lizard.

The Prospective Comparing Study of Autologous Hamstring Tendon grafts with Autologous Bone-Patella Tendon-Bone Grafts for Anterior Cruciate Ligament Reconstruction (자가 슬괵건과 자가 슬개골건골을 이용한 관절경적 전방십자인대 재건술의 전향적 비교)

  • Ahn, Gil-Yeong;Nam, Il-Hyun;Moon, Gi-Hyuk;Lee, Yeong-Hyeon;Kim, Ki-Choul;Kim, Jung-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.15 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: The purpose of this prospective study is to compare the results of arthroscopic reconstruction of ACL using autologous hamstring tendon (Group 1) and autologous bone patella tendon bone (Group 2). Materials and Methods: From Jan. 2004 to Dec. 2007, fifty patients were analyzed in this study. A single surgeon performed the ACL reconstruction with autologous hamstring tendon (25 patients) and autologous bone patella tendon bone (25 patients) alternatively each other. The mean follow up period of two groups was 38 months (range 25~58 months). We evaluated the result of Lachman test, Pivot shift test as a physical examination and Lysholm score, Tagner activity scale as patients' satisfaction and functional status and Telometer for anterior instability of each groups at the time of final follow up. Results: In final results, negative or mild positive findings on Lachman test were 24 out of 25 cases (equally) in each groups.) Twenty two cases in the Group 1 and 21 cases in the Group 2 were negative on Pivot shift test. Lysholm scores mark 94.6 points in group 1 and 92.3 points in group 2 at the final follow up and Tegner activity scales mark 8.5 points (Group 1) and 8.1 points (Group 2) at the time of last follow up and there were no differences between the two groups statistically. The numbers of patients who have less than 5 mm of anterior translation of tibia under telometer at 20 degrees of knee flexion are 24 cases in group 1 and 23 cases in group 2. Conclusion: The overall improvements of clinical scores (Lysholm scores and Tegner Activity scales) of the group 1 were a little bit superior to those of the group 2, but there were no significant statistical difference between two groups.

  • PDF

Short Term Results of Arthroscopic ACL Reconstruction using Fresh Frozen Achilles Allograft (신선동결 동종 아킬레스건을 이용한 전방십자인대 재건수술의 단기추시 결과)

  • Choi, Ho-Rim;Park, Jong-Seok;Lee, Sang-Seon;Woo, Seung-Han;Hong, Chang-Hwa;Kim, Byung-Heum;Lee, Byung-Ill
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.41-44
    • /
    • 2006
  • Purpose: To evaluate the short-term results of arthroscopic ACL reconstruction using fresh frozen Achilles allograft Materials & Methods: From March 2002 to March 2004, arthroscopic ACL reconstructions using fresh frozen Achilles allograft were performed in 25 knees of 25 patients. The average age at operation was 30.1 years (range, 18-50 years) and the average follow-up was 17 months (range, 12 to 27months). Preoperative and follow-up clinical results were evaluated using the Lysholm knee score, IKDC knee rating system, physical examination and KT-2000 arthrometer. Results: The Lachman test was positive in 25 patients preoperatively and 18 patients(72%) had negative results at latest follow-up. The average side-to-side differences of anterior tibial translation using KT-2000 arthrometer under loading of 301b were improved from $7.9{\pm}2.4mm\;to\;2.6{\pm}1.6mm$. The average Lysholm score was improved from $61.1{\pm}13.9\;to\;93.5{\pm}5.3$ points. The IKDC grade was abnormal(C) or severely abnormal(D) in 25 cases preoperatively They improved 22(88%) of normal(A) or nearly normal(B) and 3(12%) of abnormal. Conclusion: Short term results of ACL reconstruction using Achilles allograft was acceptable. Achilles allograft can be a reasonable graft alternative to autograft for ACL reconstruction.

  • PDF

The Effect on the Lower Limbs Joint as the Landing Height and Floor Pattern (착지 높이와 지면 형태가 하지 관절에 미치는 영향)

  • Kim, Eun-Kyong
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.437-447
    • /
    • 2011
  • In this study, the lower limbs joints were analyzed for features based on the biomechanical characteristics of landing techniques according to height and landing on the ground type (flats and downhill). In order to achieve the objectives of the study, changes were analyzed in detail contents such as the height and form of the first landing on the ground at different angles of joints, torso and legs, torso and legs of the difference in the range of angular motion of the joint, the maximum angular difference between joints, the lower limbs joints difference between the maximum moment and the difference between COM changes. The subjects in this study do not last six months did not experience joint injuries 10 males in 20 aged were tested. Experimental tools to analyze were the recording and video equipment. Samsung's SCH-650A model camera was used six units, and the 2 GRF-based AMTI were used BP400800 model. 6-unit-camera synchronized with LED (photo cell) and Line Lock system were used. the output from the camera and the ground reaction force based on the data to synchronize A/D Syc. box was used. To calculate the coordinates of three-dimensional space, $1m{\times}3m{\times}2m$ (X, Y, Z axis) to the size of the control points attached to the framework of 36 markers were used, and 29 where the body was taken by attaching a marker to the surface. Two kinds of land condition, 40cm and 60cm in height, and ground conditions in the form of two kinds of flat and downhill slopes ($10^{\circ}$) of the landing operation was performed and each subject's 3 mean two-way RM ANOVA in SPSS 18.0 was used and this time, all the significant level was set at a=.05. Consequently, analyzing the landing technique as land form and land on the ground, the changes of external environmental factors, and the lower limbs joints' function in the evaluation were significantly different from the slopes. Landing of the slop plane were more load on the joints than landing of plane. Especially, knee extensor moment compared to the two kinds of landing, slopes plane were approximately two times higher than flat plane, and it was statistical significance. Most of all not so much range of motion and angular velocity of the shock to reduce stress was important. In the further research, front landing as well as various direction of motion of kinetic, kinetic factors and EMG variables on lower limbs joints of the study in terms of injury-prevention-approach is going to be needed.

Therapeutic effects of Hominis placenta herb-acupuncture in adjuvant-induced arthritis rat (흰쥐의 Adjuvant 관절염에 대한 자하거(紫河車) 약침의 효과)

  • Yeom, Mi-Jung;Kang, Ji-Eun;Hahm, Dae-Hyun;Park, Hi-Joon;H.Lee, Eun-Joo;Shim, In-Sop;Lee, Hye-Jung
    • Journal of Pharmacopuncture
    • /
    • v.5 no.1 s.8
    • /
    • pp.91-103
    • /
    • 2002
  • Rheumatoid arthritis (RA) is a chronic inflammatory autoimmune disease. characterized by leukocyte infiltration, a chronic inflammation of the joint, a pannus formation and the extensive destruction of the 3Iticular caJ1ilage and bone. Several proinflammatory cytokines such as tumor necrosis factor-${\alpa}$(TNF-${\alpa}$), interleukin-1${\beta}$ (IL-1${\beta}$) and interleukin 6 (IL-6) have been implicated in the pathological mechanisms of synovial tissue proliferation, joint destruction and programmed cell death in rheumatoid joint. In the Korean traditional medicine, Hominis placenta (HP) as an herbal solution of herb-acupuncture has been widely used to treat the inflammatory diseases including RA. In order to study the medicinal effect of HP herb-acupuncture on rheumatoid joint, an adjuvant-induced arthritis (AlA) was generated by the injection of 1.5 mg uf Mycobactelium tuberculusis. emulsified in squalene, 10 the base of the tail of Sprague-Dawley(SD) rats. After onset stage of polyarthritis, HP was daily injected to the Zusanti (ST36) acupuncture points in both of rat lags and the expression pattems of cytokines such as TNF-{\alpa}$, IL-1${\beta}$, and 1L-6 at the knee joint were analyzed using immunostaining and RT-PCR. The HP herb-acupuncture was found to be effective to alleviate the arthritic symptums in adjuvant-induced arthritic rats as regards the joint appearance and the expression profiles of inflammatory cytokines. In conclusion, therapeutic effects of HP herb-acupuncture on the rat with AlA might be related to anti inflammatory activities of the hurb-acupuncture.