• Title/Summary/Keyword: Kinematic parameters

Search Result 419, Processing Time 0.021 seconds

Differences in the Length Change Pattern of the Medial Gastrocnemius Muscle-Tendon Complex and Fascicle during Gait and One-legged and Two-legged Vertical Jumping (보행과 한발·두발 수직점프 수행 시 내측비복근 근-건 복합체와 근섬유다발의 길이 변화 패턴의 차이)

  • Lee, Hae-Dong;Han, Bo-Ram;Kim, Jin-Sun;Oh, Jeong-Hoon;Cho, Han-Yeop;Yoon, So-Ya
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.175-182
    • /
    • 2015
  • Objective : The purpose of this study was to investigate difference in fascicle behavior of the medial gastrocnemius during the locomotion with varying intensities, such as gait and one-legged and two-legged vertical jumping. Methods : Six subjects (3 males and 3 females; age: $27.2{\pm}1.6yrs.$, body mass: $62.8{\pm}9.8kg$, height: $169.6{\pm}8.5cm$) performed normal gait (G) at preferred speed and maximum vertical jumping with one (OJ) and two (TJ) legs. While subjects were performing the given tasks, the hip, knee and ankle joint motion and ground reaction force was monitored using a 8-infrared camera motion analysis system with two forceplates. Simultaneously, electromyography of the triceps surae muscles, and the fascicle length of the medial gastrocnemius were recorded using a real-time ultrasound imaging machine. Results : Comparing to gait, the kinematic and kinetic parameters of TJ and OJ were found to be significantly different. Along with those parameters, change in the medial gastrocnemius (MG) muscle-tendon complex (MTC) length ($50.57{\pm}6.20mm$ for TJ and $44.14{\pm}5.39mm$ for OJ) and changes in the fascicle length of the MG ($18.97{\pm}3.58mm$ for TJ and $20.31{\pm}4.59mm$ for OJ) were observed. Although the total excursion of the MTC and the MG fascicle length during the two types of jump were not significantly different, however the pattern of length changes were found to be different. For TJ, the fascicle length maintained isometric longer during the propulsive phase than OJ. Conclusion : One-legged and two-legged vertical jumping use different muscle-tendon interaction strategies.

A Study on the Design Criteria of Pedestrian Facility (Stairs) by Motion Analysis of Walking Parameters in the Elderly (고령자 보행변수 실측을 통한 보행시설물 설계기준 정립 1: 고령자 보행특성을 고려한 계단 챌면 높이 연구)

  • ROH, Chang-Gyun;PARK, Bum Jin
    • Journal of Korean Society of Transportation
    • /
    • v.35 no.5
    • /
    • pp.396-408
    • /
    • 2017
  • In Korea, the number of elderly has been increasing rapidly. So it is also expected that the economic activity and the trip frequency of the elderly will increase. On the other hand, elderly related accidents such as falls during walking are steadily increasing and the satisfaction about pedestrian environment of elderly is very low. In this paper, we found one of the reasons for these dissatisfaction in pedestrian facility, which is not considering the walking ability (about 75% of non-elderly person) of the elderly. So, we analyze the kinematic walking characteristics of the elderly with the motion analysis system, when the elderly use stairs. As a result of analysis of various walking variables, the current standard for stairway height in Korean law (18cm) requires excessive force to elderly so it was difficult for elderly to keep the balance of the body in ascending and descending walk of stairs. In this paper, we propose the stair design criteria through the cluster analysis of walking parameters reflecting the gait characteristics of the elderly. This change is not a big for non-elderly person, but it can promote more socioeconomic activities for the elderly.

The Effects of Wearing Roller Shoes on Ground Reaction Force Characteristics During Walking (롤러 신발과 조깅 슈즈 신발 착용 후 보행 시 지면반력의 형태 비교 분석)

  • Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.1
    • /
    • pp.101-108
    • /
    • 2006
  • The purpose of this study was to compare GRF characteristics during walking wearing jogging and roller shoes. Twelve male middle school students (age: $15.0{\pm}0.0\;yrs$, height: $173.6{\pm}5.0\;cm$, weight: $587.6{\pm}89.3\;N$) who have no known musculoskeletal disorders were recruited as the subjects. Kinematic data from six S-VHS camcorders(Panasonic AG456, 60 fields/s) and GRF data from two force platform; (AMII OR6-5) were collected while subjects walked wearing roller and jogging shoes in random order at a speed of 1.1 m/s. An event sync unit with a bright LED light was used to synchronize the video and GRF recordings. GRF data were filtered using a 20 Hz low pass Butterworth. digital filter and further normalized to the subject's body weight. For each trial being analyzed, five critical instants and four phases were identified from the recording. Temporal parameters, GRFs, displacement of center of pressure (DCP), and loading and decay rates were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions (p <.05). Vertical GRFs at heel contact increased and braking forces at the end of initial double limb stance reduced significantly when going from jogging shoe to roller shoe condition. Robbins and Waked (1997) reported that balance and vertical GRF are closely related It seems that the ankle and knee joints are locked in an awkward fashion at the heel contact to compensate for the imbalance. The DCP in the antero-posterior direction for the roller shoe condition was significantly less than the corresponding value for the jogging shoe condition. Because the subjects tried to keep their upper body weight in front of the hip to prevent falling backward, the DCP for the roller shoe condition was restricted The results indicate that walking with roller shoes had little effect on temporal parameters, and loading and decay rates. It seems that there are differences in GRF characteristics between roller shoe and jogging shoe conditions. The differences in GRF pattern may be caused primarily by the altered position of ankle, knee, and center of mass throughout the walking cycle. Future studies should examine muscle activation patterns and joint kinematics during walking with roller shoes.

Pectinase-treated Panax ginseng protects against chronic intermittent heat stress-induced testicular damage by modulating hormonal and spermatogenesis-related molecular expression in rats

  • Kopalli, Spandana Rajendra;Cha, Kyu-Min;Lee, Sang-Ho;Ryu, Ji-Hoon;Hwang, Seock-Yeon;Jeong, Min-Sik;Sung, Jong-Hwan;Kim, Si-Kwan
    • Journal of Ginseng Research
    • /
    • v.41 no.4
    • /
    • pp.578-588
    • /
    • 2017
  • Background: Elevated testicular temperature disrupts spermatogenesis and causes infertility. In the present study, the protective effect of enzymatically biotransformed Panax ginseng Meyer by pectinase (GINST) against chronic intermittent heat stress-induced testicular damage in rats was investigated. Methods: Male Sprague-Dawley rats (4 wk old, 60-70 g) were divided into four groups: normal control (NC), heat-stress control (HC), heat-stress plus GINST-100 mg/kg (HG100), and heat-stress plus GINST-200 mg/kg (HG200) treatment groups. Each dose of GINST (100 mg/kg and 200 mg/kg) was mixed separately with a regular pellet diet and was administered orally for 24 wk. For inducing heat stress, rats in the NC group were maintained at $25^{\circ}C$, whereas rats in the HC, HG100, and HG200 groups were exposed to $32{\pm}1^{\circ}C$ for 2 h daily for 6 mo. At week 25, the testes and serum from each animal were analyzed for various parameters. Results: Significant (p < 0.01) changes in the sperm kinematic values and blood chemistry panels were observed in the HC group. Furthermore, spermatogenesis-related molecules, sex hormone receptors, and selected antioxidant enzyme expression levels were also altered in the HC group compared to those in the NC group. GINST (HS100 and HS200) administration significantly (p < 0.05) restored these changes when compared with the HC group. For most of the parameters tested, the HG200 group exhibited potent effects compared with those exhibited by the HG100 group. Conclusion: GINST may be categorized as an important medicinal herb and a potential therapeutic for the treatment of male subfertility or infertility caused by hyperthermia.

Kinematic Effects of Newly Designed Knee-Ankle-Foot Orthosis With Oil Damper Unit on Gait in People With Hemiparesis

  • Park, Hyung-Ki;Kim, Tack-Hoon;Choi, Houng-Sik;Roh, Jung-Suk;Cynn, Heon-Seock;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.64-73
    • /
    • 2013
  • The purposes of this study were to develop a new orthosis controlling ankle and knee joint motion during the gait cycle and to identify the effects of the newly designed orthosis on gait kinematics and tempospatial parameters, including coordination of the extremities in stroke patients. Fifteen individuals who had sustained a stroke, onset was 16 months, participated in this study. Before application of the measurement equipment the subjects were accustomed to walking on the ankle-foot orthosis (AFO) or stance control knee with knee flexion assisted-oil damper ankle-foot orthosis (SCKAFO) for 5 minutes. Fifteen patients were investigated for 45 days with a 3-day interval between sessions. Measurements were walking in fifteen stroke with hemiparesis on the 3D motion analysis system. Comparison of AFO and SCKAFO are gait pattern. The difference between the AFO and SCKAFO conditions was significant in the gait velocity, step length of the right affected side, stance time of both legs, step-length asymmetry ratio, single-support-time asymmetry ratio, ${\phi}$-thigh angle and ${\phi}$-shank angle in the mid swing (p<.001). Using a SCKAFO in stroke patients has shown similar to normal walking speeds can be attained for walking efficiency and is therefore desirable. In this study, the support time of the affected leg with the SCKAFO was longer than with the AFO and the asymmetry ratio of single support time decreased by more than with the AFO. This indicates that the SCKAFO was effective for improving gait symmetry, single-support-time symmetry. This may be due to the decrease of gait asymmetry. Thus, the newly designed SCKAFO may be useful for promoting gait performance by improving the coordination of the extremity and decreasing gait asymmetry in chronic stroke patients.

Association Study Analysis of Cluster-of-Differentiation Antigen 9 (CD9) Gene Polymorphism (g.358A>T) for Duroc Boar Post-thawed Semen Motility and Kinematic Characteristics

  • Cho, Eun-Seok;Sa, Soo-Jin;Kim, Ki-Hyun;Lee, Mi-Jin;Ko, Jun-Ho;Kim, Young-Ju;Seol, Kuk-Hwan;Hong, Joon-ki;Kim, Kwang-Sik;Kim, Yong-Min;Woo, Jae-Seok
    • Journal of Embryo Transfer
    • /
    • v.30 no.2
    • /
    • pp.109-114
    • /
    • 2015
  • Cryopreservation of boar semen is continually researched in reproductive technologies and genetic resource banking in breed conservation. For evaluating the boar semen quality, sperm motility (MOT) is an important parameter because the movement of spermatozoa indicates active metabolism, membrane integrity and fertilizing capacity. Various researches have been trying to improve the quality of semen post-thawed in boar. Recently, polymorphism (g.358A>T) of cluster-of-differentiation antigen 9 (CD9) gene reported to be significant association with MOT. Also, CD9 gene was expressed in the male germ line stem cells is crucial for sperm-egg fusion, and was therefore selected as candidate gene for boar semen. This study was conducted to evaluate the pig SNP (g.358A>T) of CD9 gene as a positional controlling for semen parameters of post-thawed boar semen. To results, the g.358A>T SNP of the CD9 gene was significantly associated with the traits such as MOT, curve linear velocity, straight line velocity, average path velocity and amplitude of lateral head displacement. Particularly, the g.358A>T SNP significantly has the highest association with MOT and animals with AA genotype (p<0.001). Therefore, we suggest that the g.358A>T in the intron 6 region of the porcine CD9 may be used as a molecular marker for Duroc boar Post-thawed semen quality, although its functional effect was not defined yet.

Effects of Walking Speeds and Cognitive Task on Gait Variability (보행속도변화와 동시 인지과제가 보행 가변성에 미치는 영향)

  • Choi, Jin-Seung;Kang, Dong-Won;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.2
    • /
    • pp.49-58
    • /
    • 2008
  • The purpose of this study was to identify effects of walking speed and a cognitive task during treadmill walking on gait variability. Experiments consisted of 5 different walking speeds(80%, 90%, 100%, 110% and 120% of preferred walking speed) with/without a cognitive task. 3D motion analysis system was used to measure subject's kinematic data. Temporal/spatial variables were selected for this study; stride time, stance time, swing time, step time, double support time, stride length, step length and step width. Two parameters were used to compare stride-to-stride variability with/without cognitive task. One is the coefficient of variance which is used to describe the amount of variability. The other is the detrended fluctuation analysis which is used to infer self-similarity from fluctuation of aspects. Results showed that cognitive task may influence stride-to-stride variability during treadmill walking. Further study is necessary to clarify this result.

Retrieval of Relative Surface Temperature from Single-channel Middle-infrared (MIR) Images (단일밴드 중적외선 영상으로부터 표면온도 추정을 위한 상대온도추정알고리즘의 연구)

  • Wook, Park;Won, Joong-Sun;Jung, Hyung-Sup
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.1
    • /
    • pp.95-104
    • /
    • 2013
  • In this study, a novel method is proposed for retrieving relative surface temperature from single-channel middle infra-red (MIR, 3-5 ${\mu}m$) remotely sensed data. In order to retrieve absolute temperature from MIR data, it is necessary to accommodate at least atmospheric effects, surface emissivity and reflected solar radiance. Instead of retrieving kinematic temperature of each target, we propose an alternative to retrieve the relative temperature between two targets. The core idea is to minimize atmospheric effects by assuming that the differential at-sensor radiance between two targets experiences the same atmospheric effects. To reduce effective simplify atmospheric parameters, each atmospheric parameter was examined by MODTRAN and MIR emissivity derived from ASTER spectral libraries. Simulation results provided a required accuracy of 2 K for materials with a temperature of 300 K within 0.1 emissivity errors. The algorithm was tested using MODIS band 23 MIR day time images for validation. The accuracy of retrieved relative temperature was $0.485{\pm}1.552$ K. The results demonstrated that the proposed algorithm was able to produce relative temperature with a required accuracy from only single-channel radiance data. However, this method has limitations when applied to materials having very low temperatures using day time MIR images.

Study on Performance of Vertical-axis Tidal Turbines Applied to the Discharged Channel of Power Plant (조류발전용 수직축 터빈의 방수로 설치에 따른 성능에 관한 연구)

  • Lee, Jeong-Ki;Hyun, Beom-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.274-281
    • /
    • 2015
  • Thermal and nuclear power plants on shore commonly use the sea water for cooling facility. Discharged cooling water has the high kinematic energy potential due to amount of water flux. Numerical analysis was made to find the suitable combinations between the arrangement of tidal turbines and the overall dimensions of the discharged channel. Several parameters such as the turbine diameter to inlet size, and the axial distance to turbine size were investigated. Power coefficients for various test conditions were also compared to see the effect of inlet configurations such as single inlet and dual inlet. For the single inlet, the mean power coefficient appeared to be gradually decreased with increasing distance, and the maximum power was obtained when the turbine diameter was same as the inlet diameter. For the dual inlet, the tendency was similar so that the better result when the turbine diameter was same as the inlet diameter. It is expected that the present methodology can be extensively utilized to harness the high kinetic energy flow of the discharge channel of power plant.

Objective Identification of Human Sperm Hyperactivation by Computerized Sperm Motion Analysis (Computerized Sperm Motility Analyzer를 이용한 Human Sperm의 Hyperactivated Motility의 객관적 관찰에 관한 연구)

  • Lee, Hee-Kyung;Lee, Chan;Kim, Hyun-Sook;Kim, Young-Tae;Kim, Sun-Haeng;Ku, Pyoung-Sahm
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 1994
  • The occurrence and time course of capacitation, acrosomal loss, and hyperactivated motility require quantitative definition in order to characterize fertile human sperm. Recently the method has been developed to estimate the quality of spermatozoa by using kinematic parameters such as curvilinear velocity(VCL), average path velocity(VAP), linearity(LIN), straightness(STR), amplitude of lateral head displacement(ALH), and beat cross frequence(BCF) from Computer Assisted Sperm Analysis (CASA). In this study, using the Hamilton Thorn motility analyzer HTM 2030(Hamilton Thorn Research, Beverly, MA), we attempted to identify the spermatozoa with hyperactivated motility (HA) objectively and to monitor hyperactivation of human spermatozoa during incubation in capacitating media and after treatment of calcium ionophore as compared with acrosome status. And we examined whether HA are related to the result of SPA. Semen samples obtained from 16 healthy men were prepared by swim up technique and preincubated in a capacitating media(modified BWW medium) for 5 hours and treated with calcium ionophore solution. The acrosome reaction was detected with PSA-FITC labelling of the acrosome and in vitro sperm ferilizing capacity was assessed by the zona free hamster ovum penetration assay (SPA). The incidence of hyperactivated sperm was 2.6% in fresh semen, 14.3% of the swim up population, 13.7% after 5h of incubation. Significant increase of percentage of hyperactivated sperm was observed after the incubation (p<0.05) but after treatment, no significant changes of percentage of hyperactivated sperm(l1.8%) in contrast to significant rise in the percentage of acrosome reacted cells. Correlation analysis failed to show any significant relationship between the percentage of sperm with HA and SPA score. In conclusion, although no direct correlations were found between the results of SPA and HA, hyperactivation of sperm is associated with capacitation and monitoring hyperactivated sperm will be expected as a method of evaluating the functional quality of sperm such as SPA.

  • PDF