• Title/Summary/Keyword: Kinematic parameters

Search Result 419, Processing Time 0.027 seconds

Dynamic Performance Analysis for 6WD/6WS Armored Vehicles (6WD/6WS 군용차량의 동역학적 성능해석)

  • 홍재희;김준영;허건수;장경영;오재응
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.6
    • /
    • pp.155-166
    • /
    • 1997
  • In this study, a simulation tool is developed in order to investigate non steady-state cornering performance of 6WD/6WS special-purpose vehicles. 6WD vehicles are believed to have good performance on off-the-road maneuvering and to have fail-safe capabilities. But the cornering performances of 6WS vehicles are not well understood in the related literature. In this paper, 6WD/6WS vehicles are modeled as a 18 DOF system which includes non-linear vehicle dynamics, tire models, and kinematic effects. Then the vehicle model is constructed into a simulation tool using the MATLAB /SIMULINK so that input/output and vehicle parameters can be changed easily with the modulated approach. Cornering performance of the 6WS vehicle is analyzed for brake steering and pivoting, respectively. Simulation results show that cornering performance depends on the middle-wheel steering as well as front/rear wheel steering. In addition, a new 6WS control law is proposed in order to minimize the sideslip angle. Lane change simulation results demonstrate the advantage of 6WS vehicles with the proposed control law.

  • PDF

A Study on Track Record and Trajectory Control of Robot Manipulator with Eight Joints Based on Monitoring Simulator for Smart Factory

  • Kim, Hee-jin;Jang, Gi-won;Kim, Dong-ho;Han, Sung-hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_1
    • /
    • pp.549-558
    • /
    • 2020
  • We describe a new approach to real-time implementation of track record and trajectory control of robotic manipulator with eight joints based on monitoring simulator. Trajectory generator uses the kinematic equations of the arm to convert the task description into a series of set points for each of the joint control loops, while the joint controllers, with simple algorithms for just one joint can move at a fast sampling rate, guaranteeing a smooth motion. The proposed control scheme is robust, fast in computation, and suitable for real-time control. Moreover, this scheme does not require any accurate parameter information, nor values of manipulator parameters and payload. Reliability of the proposed technology is veriefied by monitoring simulation and experimental of robot manipulator for the smart factory with eight degrees of freedom.

Effects of Panax ginseng, zearalenol, and estradiol on sperm function

  • Gray, Sandra L.;Lackey, Brett R.;Boone, William R.
    • Journal of Ginseng Research
    • /
    • v.40 no.3
    • /
    • pp.251-259
    • /
    • 2016
  • Background: Estrogen signaling pathways are modulated by exogenous factors. Panax ginseng exerts multiple activities in biological systems and is classified as an adaptogen. Zearalenol is a potent mycoestrogen that may be present in herbs and crops arising from contamination or endophytic association. The goal of this study was to investigate the impact of P. ginseng, zearalenol and estradiol in tests on spermatozoal function. Methods: The affinity of these compounds for estrogen receptor (ER)-alpha and beta ($ER{\alpha}$ and $ER{\beta}$)-was assessed in receptor binding assays. Functional tests on boar spermatozoa motility, movement and kinematic parameters were conducted using a computer-assisted sperm analyzer. Tests for capacitation, acrosome reaction (AR), and chromatin decondensation in spermatozoa were performed using microscopic analysis. Results: Zearalenol-but not estradiol ($E_2$)- or ginseng-treated spermatozoa-decreased the percentage of overall, progressive, and rapid motile cells. Zearalenol also decreased spontaneous AR and increased chromatin decondensation. Ginseng decreased chromatin decondensation in response to calcium ionophore and decreased AR in response to progesterone ($P_4$) and ionophore. Conclusion: Zearalenol has adverse effects on sperm motility and function by targeting multiple signaling cascades, including $P_4$, $E_2$, and calcium pathways. Ginseng protects against chromatin damage and thus may be beneficial to reproductive fitness.

Bio-inspired Walking and Swimming Underwater Robot Designing Concept and Simulation by an Approximated Model for the robot (유영과 보행이 가능한 생체모방 수중 로봇의 설계개념과 근사모델을 활용한 모의실험)

  • Kim, Hee-Joong;Jun, Bong-Huan;Lee, Jihong
    • The Journal of Korea Robotics Society
    • /
    • v.9 no.1
    • /
    • pp.57-66
    • /
    • 2014
  • This paper describes the design concept of a bio-inspired legged underwater and estimating its performance by implementing simulations. Especially the leg structure of an underwater organism, diving beetles, is fully adopted to our designing to employ its efficiency for swimming. To make it possible for the robot to both walk and swim, the transformable kinematic model according to applications of the leg is proposed. To aid in the robot development and estimate swimming performance of the robot in advance, an underwater simulator has been constructed and an approximated model based on the developing robot was set up in the simulation. Furthermore, previous work that we have done, the swimming locomotion produced by a swimming patten generator based on the control parameters, is briefly mentioned in the paper and adopted to the simulation for extensive studies such as path planning and control techniques. Through the results, we established the strategy of leg joints which make the robot swim in the three dimensional space to reach effective controls.

Accurate Calibration of Kinematic Parameters for Two Wheel Differential Drive Robots by Considering the Coupled Effect of Error Sources (이륜차동구동형로봇의 복합오차를 고려한 기구학적 파라미터 정밀보정기법)

  • Lee, Kooktae;Jung, Changbae;Jung, Daun;Chung, Woojin
    • The Journal of Korea Robotics Society
    • /
    • v.9 no.1
    • /
    • pp.39-47
    • /
    • 2014
  • Odometry using wheel encoders is one of the fundamental techniques for the pose estimation of wheeled mobile robots. However, odometry has a drawback that the position errors are accumulated when the travel distance increases. Therefore, position errors are required to be reduced using appropriate calibration schemes. The UMBmark method is the one of the widely used calibration schemes for two wheel differential drive robots. In UMBmark method, it is assumed that odometry error sources are independent. However, there is coupled effect of odometry error sources. In this paper, a new calibration scheme by considering the coupled effect of error sources is proposed. We also propose the test track design for the proposed calibration scheme. The numerical simulation and experimental results show that the odometry accuracy can be improved by the proposed calibration scheme.

Kinematic Parameter Optimization of Jumping Robot Using Energy Conversion of Elastic Body (탄성체의 에너지 변환을 이용한 점프 로봇의 기구변수 최적화)

  • Choi, JaeNeung;Lee, Sangho;Jeong, Kyungmin;Seo, TaeWon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.1
    • /
    • pp.53-58
    • /
    • 2016
  • Various jumping robot platforms have been developed to carry out missions such as rescues, explorations, or inspections of dangerous environments. We suggested a jumping robot platform using energy conversion of the elastic body like the bar of a pole vault, which is the main part in which elastic force occurs. The compliant link was optimized by an optimization method based on Taguchi methodology, and the robot's leaping ability was improved. Among the parameters, the length, width, and thickness of the link were selected as design variables first while the others were fixed. The level of the design variables was settled, and an orthogonal array about its combination was made. In the experiment, dynamic simulations were conducted using the DAFUL program, and response table and sensitivity analyses were performed. We found optimized values through a level average analysis and sensitivity analysis. As a result, the maximum leaping height of the optimized robot increased by more than 6.2% compared to the initial one, and these data will be used to design a new robot.

Robust Adaptive Fuzzy Backstepping Control for Trajectory Tracking of an Electrically Driven Nonholonomic Mobile Robot with Uncertainties (불확실성을 가지는 전기 구동 논홀로노믹 이동 로봇의 궤적 추종을 위한 강인 적응 퍼지 백스테핑 제어)

  • Shin, Jin-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.10
    • /
    • pp.902-911
    • /
    • 2012
  • This paper proposes a robust adaptive fuzzy backstepping control scheme for trajectory tracking of an electrically driven nonholonomic mobile robot with uncertainties and actuator dynamics. A complete model of an electrically driven nonholonomic mobile robot described in this work includes all models of the uncertain robot kinematics with a nonholonomic constraint, the uncertain robot body dynamics with uncertain frictions and unmodeled disturbances, and the uncertain actuator dynamics with disturbances. The proposed control scheme uses the backstepping control approach through a kinematic controller and a robust adaptive fuzzy velocity tracking controller. The presented control scheme has a voltage control input with an auxiliary current control input rather than a torque control input. It has two FBFNs(Fuzzy Basis Function Networks) to approximate two unknown nonlinear robot dynamic functions and a robust adaptive control input with the proposed adaptive laws to overcome the uncertainties such as parameter uncertainties and external disturbances. The proposed control scheme does not a priori require the accurate knowledge of all parameters in the robot kinematics, robot dynamics and actuator dynamics. It can also alleviate the chattering of the control input. Using the Lyapunov stability theory, the stability of the closed-loop robot control system is guaranteed. Simulation results show the validity and robustness of the proposed control scheme.

Analysis of Time-Distance and Kinematic Gait Parameters Between Unilateral Trans-Tibial Amputees and Healthy Subjects (하퇴의지 착용자와 정상성인 보행간의 시간-거리 및 운동형상학 변수 분석)

  • Kang, Pil;Kim, Jang-Hwan;Choi, Houng-Sik;Cynn, Heon-Seock
    • Physical Therapy Korea
    • /
    • v.9 no.4
    • /
    • pp.61-68
    • /
    • 2002
  • 본 연구는 하퇴의지 착용자와 정상 성인간의 시간-거리, 운동형상학 변수를 조사하고 비교하기 위하여 실시하였다. 연구 대상자는 외상으로 인한 하퇴 절단자로서 내골격식 하퇴의지를 착용하고 독립적으로 보행이 가능한 20명과 연령, 신장으로 짝짓기한 대조군(matched control group) 20명이 참여하였다. 보행분석은 Vicon Clinical Manager Software (VCM)를 내장한 PC에 5개의 카메라가 연결되어 있는 Vicon 512 Motion Analysis System (MAS, Oxford Metrics Inc.)을 이용하였다. 하퇴의지 착용군의 단하지 지지시간이 정상 성인군에 비해 유의하게 짧았으며(p<.05), 하퇴의지 착용군에서 슬관절의 선전이 증가되었으며 족관절의 저측굴곡이 감소되었다(p<.05). 하퇴절단자들의 보행개선을 위해서는 하퇴절단자 개인의 보행능력에 알맞은 부품의 선택, 체계적인 보행훈련 및 평가, 보행능력 향상을 위한 근력강화 프로그램 등 체계적인 재활훈련 프로그램이 필요한 것으로 사료된다. 본 연구는 연구대상자의 수가 제한되어 있으므로 연구의 결과를 일반화하기에는 제한점이 있으나, 향후 편측 하퇴절단자의 보행연구에 대한 기초 자료로 사용될 수 있을 것이라고 생각된다.

  • PDF

An Experimental Study on the Spray Characteristics of a Dual-Orifice Type Swirl Injector at Low Fuel Temperatures

  • Park, Byung-Sung;Kim, Ho-Young;Kim, Yongchan;Chung, Jin-Taek
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.7
    • /
    • pp.1187-1195
    • /
    • 2004
  • The objective of this study is to investigate the effects of fuel temperature on the spray characteristics of a dual-orifice type swirl injector used in a gas turbine. The major parameters affecting spray characteristics are fuel temperature and injection pressure entering into the injector. In this study, the spray characteristics of a dual-orifice type swirl injector are investigated by varying fuel temperature from - 30$^{\circ}C$ to 120$^{\circ}C$ and injection pressure from 0.29 to 0.69 ㎫. Two kinds of fuel having different surface tension and viscosity are chosen as atomizing fluids. As a result, injection instability occurs in the low fuel temperature range due to icing phenomenon and fuel property change with a decrease of fuel temperature. As the injection pressure increases, the range of kinematic viscosity for stable atomization becomes wider. The properties controlling the SMD of spray is substantially different according to the fuel temperature range.

Optimum Design of a 3-DOF Ultra-Precision Positioning Mechanism Using Boosters (부스터를 이용한 3자유도 초정밀 위치결정 기구의 최적설계)

  • Han Seog Young;Yi Byung-Ju;Kim Seon Jung;Kim Jong O;Chung Goo Bong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.6
    • /
    • pp.101-109
    • /
    • 2005
  • Ultra-precision positioning systems basically require high natural frequency and sufficient workspace. To cope with this requirement, flexure hinge mechanisms have been proposed. However, previous designs are hard to satisfy the functional requirements of the system due to difficulty in modeling and optimizing process applying an independent axiomatic design. Therefore, this paper proposes a new design and design-order based on semi-coupled axiomatic design. A planar 3 DOF parallel type micro mechanism is chosen as an exemplary device. Based on preliminary kinematic analysis and dynamic modeling of the system, an optimal design has been carried out. To check the effectiveness of the optimal parameters obtained from theoretical approach, simulation is performed by FEM. The simulation result shows that a natural frequency of 200.53Hz and a workspace of $2000{\mu}m{\times}2000{\mu}m$ can be ensured, which is in very close agreement with the specified goal of design.