• Title/Summary/Keyword: Ki-ho School

Search Result 1,681, Processing Time 0.037 seconds

Extraluminal Migration of Foreign Body into the Neck (식도강외로 이동한 경부이물 1예)

  • Kim, Dae-Hee;Lee, Byung-Joo;Woo, Chang-Ki;Yoon, Yong-Ho
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • v.55 no.5
    • /
    • pp.301-303
    • /
    • 2012
  • Reports of ingested foreign bodies migrating to the neck are rare. We encountered a case of fish bone that migrated out of the upper digestive tract to the thyroid gland. This foreign body was identified by computed tomography and ultrasonography about two weeks after onset, and successfully removed via neck exploration and the patient recovered well.

A Scene-Specific Object Detection System Utilizing the Advantages of Fixed-Location Cameras

  • Jin Ho Lee;In Su Kim;Hector Acosta;Hyeong Bok Kim;Seung Won Lee;Soon Ki Jung
    • Journal of information and communication convergence engineering
    • /
    • v.21 no.4
    • /
    • pp.329-336
    • /
    • 2023
  • This paper introduces an edge AI-based scene-specific object detection system for long-term traffic management, focusing on analyzing congestion and movement via cameras. It aims to balance fast processing and accuracy in traffic flow data analysis using edge computing. We adapt the YOLOv5 model, with four heads, to a scene-specific model that utilizes the fixed camera's scene-specific properties. This model selectively detects objects based on scale by blocking nodes, ensuring only objects of certain sizes are identified. A decision module then selects the most suitable object detector for each scene, enhancing inference speed without significant accuracy loss, as demonstrated in our experiments.

A Case of Focal Reexpansion Pulmonary Edema after Chest Tube Insertion (흉관 삽관 후 발생한 국소성 재팽창성 폐부종 1예)

  • Chung, Hye Kyoung;Jang, Won Ho;Kim, Yang Ki;Lee, Young Mok;Hwang, Jung Hwa;Kim, Ki-Up;Uh, Soo-Taek
    • Tuberculosis and Respiratory Diseases
    • /
    • v.67 no.1
    • /
    • pp.59-62
    • /
    • 2009
  • Reexpansion pulmonary edema is not a common phenomenon after chest tube insertion but some reports from 0% to 14%. There are various resulting complications, including acute respiratory distress syndrome. We report a case of focal reexpansion pulmonary edema after chest tube insertion. A 49-year-old male came to the hospital due to ongoing dyspnea and left chest pain for 3 days. On chest X-ray, the patient had a left pneumothrax. We planned to insert a chest tube for symptom relief. To determine whether or not the chest had expanded as a result of the chest tube insertion, the patient underwent repeated chest X-rays the following day. The patient experienced brief respiratory symptoms upon initial suction; a chest PA showed patchy consolidated infiltration at the inserted site. After 5 days of conservative management, the recovered completely.

[ $\beta$ ]-Secretase (BACE1) Inhibitors from Sanguisorbae Radix

  • Lee, Hee-Ju;Seong, Yeon-Hee;Bae, Ki-Hwan;Kwon, Soon-Ho;Kwak, Hye-Min;Nho, Si-Kab;Kim, Kyung-A;Hur, Jong-Moon;Lee, Kyung-Bok;Kang, Young-Hwa;Song, Kyung-Sik
    • Archives of Pharmacal Research
    • /
    • v.28 no.7
    • /
    • pp.799-803
    • /
    • 2005
  • In the course of screening anti-dementia agents from natural products, two $\beta$-secretase (BACE1) inhibitors were isolated from the ethyl acetate soluble fraction of Sanguisorbae Radix by the activity-guided purification using silica gel, Sephadex LH-20, and RP-HPLC. They were identified as 1,2,3-trigalloyl-4,6-hexahydroxydiphenoyl-$\beta$-D-glucopyranoside (Tellimagrandin II, 1) and 1,2,3,4,6-pentagalloyl-$\beta$-D-glucopyranoside (2) and were shown to non-competitively inhibit $\beta$-secretase (BACE1) with the $IC_{50}$ values of $3.10{\times}10^{-6}M\;and\;3.76{\times}10^{-6}M$, respectively. The Ki values of 1 and 2 were $6.84{\times}10^{-6}M\;and\;5.13{\times}10^{-6}M$. They were less inhibitory to asecretase (TACE) and other serine proteases such as chymotrypsin, trypsin, and elastase, suggesting that they were relatively specific inhibitors of BACE1.

Catalytic Activity of Au/$TiO_2$ and Pt/$TiO_2$ Nanocatalysts Synthesized by Arc Plasma Deposition

  • Jung, Chan-Ho;Kim, Sang-Hoon;Reddy, A.S.;Ha, H.;Park, Jeong-Y.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.245-245
    • /
    • 2012
  • Syntheses of oxide supported metal catalysts by wet-chemical routes have been well known for their use in heterogeneous catalysis. However, uniform deposition of metal nanoparticles with controlled size and shape on the support with high reproducibility is still a challenge for catalyst preparation. Among various synthesis methods, arc plasma deposition (APD) of metal nanoparticles or thin films on oxide supports has received great interest recently, due to its high reproducibility and large-scale production, and used for their application in catalysis. In this work, Au and Pt nanoparticles with size of 1-2 nm have been deposited on titania powder by APD. The size of metal nanoparticles was controlled by number of shots of metal deposition and APD conditions. These catalytic materials were characterized by x-ray diffraction (XRD), inductively coupled plasma (ICP-AES), CO-chemisorption and transmission electron microscopy (TEM). Catalytic activity of the materials was measured by CO oxidation using oxygen, as a model reaction, in a micro-flow reactor at atmospheric pressure. We found that Au/$TiO_2$ is reactive, showing 100% conversion at $110^{\circ}C$, while Pt/$TiO_2$ shows 100% conversion at $200^{\circ}C$. High activity of metal nanoparticles suggests that APD can be used for large scale synthesis of active nanocatalysts. We will discuss the effect of the structure and metal-oxide interactions of the catalysts on catalytic activity.

  • PDF

Primary Malignant Fibrous Histiocytoma of the Pleura

  • Cho, Kyung-Hwa;Park, Chul;Hwang, Ki-Eun;Hwang, Yu-Ri;Seol, Chang-Hwan;Choi, Keum-Ha;Lee, Mi-Kyung;Choi, Soon-Ho;Kim, Hak-Ryul;Jeong, Eun-Taik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.74 no.5
    • /
    • pp.222-225
    • /
    • 2013
  • Malignant fibrous histiocytoma, a type of sarcoma, is a malignant neoplasm with uncertain origin that arises in both the soft tissues and the bone. The occurrence of primary malignant fibrous histiocytoma of the pleura is extremely rare. We report a case of a 65-year-old Korean man who is being diagnosed with primary malignant fibrous histiocytoma of the pleura.

A Study on the Correlation between Scoliosis and Foot (척추측만과 족부의 상관관계 연구)

  • Choi, Hyun-Im;Choi, Hong-Yun;Park, Hung-Ki;Song, Ju-Young;Kown, Young-Shil;Nam, Ki-Won;Song, Ju-Min;Lee, Yun-Seob;Choi, Jin-Ho;Kim, Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.265-272
    • /
    • 2001
  • The object of this thesis is to study the correlation between scoliosis and foot in a theoretical and empirical method. My research process was investigated for 34 students on the forward bending test, foot printer test, feedoscope test, X-ray test and so on. The main results of this study were as follows: 1. There was statistical significance on the correlation between foot length and spine length. 2. Scoliosis angle is the smallest on the pes plannus group and the biggest on the pes cavus group without statistical significance. 3. Left lumbar curve is the smallest, and right thoracic spine curve is the biggest on the left foot pattern group with statistical significance. 4. On the foot weightbearing groups, there was statistical significance both of between left and right foot groups. 5. There was no statistical significance on the t-test analysis between left foot area and right foot area according to scoliosis typology.

  • PDF

Development of the Atomated Prediction System for Seasonal Tropical Cyclone Activity over the Western North Pacific and its Evaluation for Early Predictability (북서태평양 태풍 진로의 계절예측시스템 자동화 구축 및 조기 예측성의 검증)

  • Jin, Chun-Sil;Ho, Chang-Hoi;Park, Doo-Sun R.;Choi, Woosuk;Kim, Dasol;Lee, Jong-Ho;Chang, Ki-Ho;Kang, Ki-Ryong
    • Atmosphere
    • /
    • v.24 no.1
    • /
    • pp.123-130
    • /
    • 2014
  • The automated prediction system for seasonal tropical cyclone (TC) activity is established at the National Typhoon Center of the Korea Meteorological Administration (KMA) to provide effective operation and control of the system for user who lacks knowledge of the system. For automation of the system, two procedures which include subjective decisions by user are performed in advance, and their output data are provided as input data. To provide the capability to understand the operational processes for operational user, the input and output data are summarized with each process, and the directory structure is reconstructed following KMA's standard. We introduce a user interface using namelist input parameters to effectively control operational conditions which is fixed or should be manually set in the previous version of the prediction system. To operationally use early prediction which become available through the automation, its performances are evaluated according to initial condition dates. As a result, high correlations between the observed and predicted TC counts are kept for all track clusters even though advancing the initial condition date from May to January.

IoT based Pure Tone Audiometer with Software Platform Compatibility (IoT 기반의 소프트웨어 플랫폼 호환성을 갖는 순음청력 검사기)

  • Kang, Sung Ho;Lee, Jyung Hyun;Kim, Myoung Nam;Seong, Ki Woong;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.2
    • /
    • pp.261-270
    • /
    • 2018
  • Hearing-impaired people are increasing rapidly due to the global aging trend. Early detection of hearing loss requires an easy-to-use audiometry device for the public. Existing audiometry systems were developed as PC-based, PDA-based, or smartphone apps. These devices were often dependent on specific software platforms and hardware platforms. In this paper, we tried to improve software platform compatibility by using cross platform, and tried to implement IoT-based pure tone audiometry device which does not require sound pressure level correction due to hardware differences. Pure tone audiometry is available in a variety of ways depending on the type of hearing loss and age. Using the IoT-based audiometry device implemented in this paper, it will be possible for an app developer who lacks hardware knowledge to easily develop an app with various scenarios for hearing screening. The results of this study will contribute to overcoming the software and hardware dependency in the development of IoT-based healthcare device.

Design and Fabrication of Miniaturized Optical Chopper Operated by Electromagnetic Actuation

  • Kim, Ho Won;Min, Seong Ki;Choi, Young Chan;Kong, Seong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.165-169
    • /
    • 2014
  • An existing infrared (IR) analysis system is generally composed of infrared source, IR focusing lenses, IR detector, and optical chopper. An optical chopper is widely used in combination with lock-in amplifier to improve the signal-to-noise ratio by periodically interrupting incident light beam. During recent years, a few researches on miniaturized optical chopper have been reported to apply to micro-scaled optical systems. In this paper, a micro optical chopper operated by electromagnetic actuation is proposed and applied to a miniaturized micro-scaled optical system operating in IR spectral range. Additionally, the fabrication method of the proposed micro chopper is demonstrated. The proposed micro optical chopper is composed of the polydimethylsiloxane (PDMS) membrane, solenoid, and permanent magnet. The permanent magnet is bonded on the PDMS membrane using an ultraviolet-activated adhesive. The operation of the chopper is based on the attractive and repulsive forces between permanent magnet and solenoid induced by an electrical current flowing through the solenoid. The fabricated micro optical chopper could operate up to 200 Hz of frequency. The maximum operating distance of the chopper with 7mm diameter membrane was $750{\mu}m$ at 100 Hz of frequency.