• 제목/요약/키워드: Ki-ho School

검색결과 1,681건 처리시간 0.033초

A Modified Ramp Reset Waveform for High Contrast Ratio in AC PDPs

  • Kim, Jae-Sung;Yang, Jin-Ho;Ha, Chang-Hoon;Whang, Ki-Woong
    • Journal of Information Display
    • /
    • 제3권4호
    • /
    • pp.13-18
    • /
    • 2002
  • In general, the background light that is produced during the reset period deteriorates the dark room contrast ratio in AC PDP. In this paper, we propose a modified ramp reset pulse that can reduce the background light to an imperceptible level. In the new reset waveform, the discharges between the scan and sustain electrodes are minimized by applying a positive bias voltage to the sustain electrode and only the weak discharges between the scan and address electrodes are found to occur during the reset period. We also adopted the MgO coated phosphor layer to improve the address voltage margin that was reduced when the bias voltage in the modified ramp reset waveform was applied. As a result, the address voltage margin of 45 V which is the same level of the conventional method was ortained and the dark room contrast ratio was improved up to 7500 : 1.

연료전지-배터리 하이브리드 전력시스템용 양방향 DC-DC 컨버터 (A Bi-directional DC-DC Converter for Fuel Cell-Battery Hybrid Electric Power Systems)

  • 이기호;김종수;강현수;이병국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.264-265
    • /
    • 2007
  • 본 논문에서는 하이브리드 전기 자동차(Hybrid Electric Vehicle, HEV)의 실제 주행패턴 데이터를 기준으로 하이브리드 전력 시스템용 양방향 DC-DC 컨버터를 설계하고, 시뮬레이터를 구성한다. HEV의 주행패턴 데이터 중 가 감속 구간 일부를 선택하여 전기적 부하 변화로 모델링하고, 이를 통해 양방향 DC-DC 컨버터의 모드별 동작을 시뮬레이션 한다.

  • PDF

Terson Syndrome Caused by Intraventricular Hemorrhage Associated with Moyamoya Disease

  • Kim, Ho-Sang;Lee, Sang-Weon;Sung, Soon-Ki;Seo, Eui-Kyo
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권6호
    • /
    • pp.367-369
    • /
    • 2012
  • Terson syndrome was originally used to describe a vitreous hemorrhage arising from aneurysmal subrarachnoid hemorrhage. Terson syndrome can be caused by intracranial hemorrhage, subdural or epidural hematoma and severe brain injury but is extremely rare in intraventricular hemorrhage associated with moyamoya disease. A 41-year-old man presented with left visual disturbance. He had a history of intraventicular hemorrhage associated with moyamoya disease three months prior to admission. At that time he was in comatose mentality. Ophthalmologic examination at our hospital detected a vitreous hemorrhage in his left eye, with right eye remaining normal. Vitrectomy with epiretinal membrane removal was performed. After operation his left visual acuity was recovered. Careful ophthalmologic examination is mandatory in patients with hemorrhagic moyamoya disease.

정전용량 센서를 이용한 나노급 이송장치의 시스템 식별에 관한 연구 (A Study on System Identification of Nano-scale Stage Using Capacitive Sensor)

  • 이재호;김승현;정준홍;박기헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.2537-2539
    • /
    • 2005
  • In many cases the systems are so complex that it is not possible to obtain reasonable models using physical laws. Also a model based on physical laws contains a number of unknown parameters even if the structure is derived from physical laws. These problems can be solved by system identification. In this paper, a nano stage system is selected as an example for system identification. The transfer functions of this system is derived by using state-space model structure based on input/output data through experiment.

  • PDF

Fabrication of Red, Green, and Blue Organic Light-emitting Diodes using m-MTDATA as a Common Hole-injection Layer

  • Seol, Ji-Youn;Yeo, Seok-Ki;Song, Min-Chul;Park, Chin-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1408-1409
    • /
    • 2005
  • Organic light-emitting diodes (OLEDs) of metalsemiconductor-metal (MSM) structure have been fabricated by using m-MTDATA [4,4',4"-tris (3-methylphenylphenylamino) triphenylamine] as a hole-injection layer (HIL). The m-MTDATA is shown to be an effective hole-injecting material for the OLED, in that the insertion of m-MTDATA greatly reduces the roughness of anode surface and improves the device performance.

  • PDF

A New High Speed Addressing Method Using The Priming Effect in AC PDP

  • Kim, Jae-Sung;Yang, Jin-Ho;Kim, Tae-Jun;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.105-108
    • /
    • 2003
  • A new high speed addressing method is proposed to reduce the addressing time below lus per line in AC PDP. In this method, the priming discharge is used to achieve a high speed addressing without adding an auxiliary electrode. Two different types of priming discharges were studied to achieve a high speed addressing and also reduce the inherent light output caused by the priming discharge in order to improve the contrast ratio characteristics. In the panel experiment, the addressing was successfully done with a lus address pulse width in the new method and the better contrast ratio was achieved in the Y-A priming rather than the Y-X priming case even though the reduction of the address period was smaller than that of the Y-X priming due to the extra address time for the priming discharges.

  • PDF

RMSP (Ramp biased Multiple Short Pulses) reset method for AC PDP

  • Yang, Jin-Ho;Kim, Jae-Seong;Jung, Jae-Chul;Whang, Ki-Woong;Chung, Woo-Joon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.325-328
    • /
    • 2003
  • We have proposed a new reset discharge method for AC PDP, which is composed of fast Ramp biased Multiple Short Pulses (RMSP). By using this method, we achieved stable reset discharges with reduced reset time. At the same time, it resulted in lower background luminance as well as stable and higher address margin using the tail effect.

  • PDF

무선 센서 네트워크에서의 라우팅 보안 기법 비교 분석 (A Study on Routing Security in Wireless Sensor Networks)

  • 김영기;이화성;김용호;이동훈
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2008년도 동계학술대회
    • /
    • pp.117-120
    • /
    • 2008
  • 무선 센서 네트워크란 물리적, 환경적 현상을 감지하기 위해 센서를 사용하는 수백 개에서 수천 개의 센서 노드로 구성된 네트워크를 말한다. 이러한 무선 센서 네트워크에서 라우팅 보안은 중요하다. 센싱된 데이터가 사용자에게 전달되지 않는다면 네트워크는 그 기능을 제대로 수행한다고 할 수 없기 때문이다. 따라서 무선 센서 네트워크에서 데이터가 목적지에 안전하게 도달하도록 하는 라우팅 보안 기법은 필수적이다. 최근의 라우팅 보안은 암호학적 기법, 네트워크 컴퓨터 알고리즘을 이용한 기법 등 다양한 접근 방법으로 연구가 이루어지고 있다. 본 논문에서는 최근의 무선 센서 네트워크 라우팅 보안 기법의 동향을 살펴보고 이들을 비교 분석한다.

  • PDF

Modal Interactions in an Autoparametric Vibration Absorber to Narrow Band Random Excitation

  • Cho, Duk-Sang;Mo, Chang-Ki;Ban, Gab-Su;Lee, Kwang-Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제17권1호
    • /
    • pp.97-104
    • /
    • 2003
  • The main objectives of this study are to examine the random responses of a vibration absorber system with autoparametric coupling in the neighborhood of internal resonance subjected to narrow band random excitation by Gaussian closure scheme and to compare the results with those obtained by Monte Carlo simulation. The Monte Carlo simulation is found to support the main features of the nonlinear modal interaction in the neighborhood of internal resonance conditions. The jump phenomenon of the cantilever mode and saturation phenomenon of the main system are shown to occur if the excitation bandwidth is sufficiently small.

실외기 shroud 형상 최적 설계 (Optimization of design parameters on the shroud of air conditioner outdoor unit)

  • 유기정;예휘열;이상봉;이관수;차우호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.453-458
    • /
    • 2009
  • This paper presents a numerical evaluation of the flow rate of air conditioner outdoor unit as function of shroud design parameters. To determine the optimal design parameters, we investigated the flow rate by changing bell mouth height, fan height, fan guide height, fan width. The evaluation of the relative priority of the design parameters was performed to choose three important parameters in order to use a response surface method. The flow rate of the optimum model, compared to that of the base model, was increased by about 6.25%.

  • PDF