• Title/Summary/Keyword: Kec

Search Result 84, Processing Time 0.023 seconds

Fabrication and Characteristics of 300V Mo-MPS Rectifier (300V용 Mo-MPS 정류기의 제조 및 그 특성)

  • 최형호;박근용;김준식;최시영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.6
    • /
    • pp.393-399
    • /
    • 2003
  • The current paper presents a new Mo-MPS rectifier using molybdenum as barrier metal to improve on the low forward voltage drop and power dissipation of the coventional Al-MPS and Pt-MPS rectifier. Electrical characteristics of the fabricated Mo-MPS rectifier are imvestigated compared with Al-MPS and Pt-MPS rectifier. At the same current level, the forward voltage drop of the Mo-MPS was reduced by 0.11V~0.24V compared to that of the conventional MPS rectifier. Accordingly, since the Power dissipation of a rectifier mostly depends on the forward current density and forward voltage drop, the Mo-MPS rectifier achieved improved power dissipation when compared to the conventional MPS rectifier. The reverse breakdown voltage of a Mo-MPS rectifier with 68% Schottky junction area was about 304y. Despite having a lower forward voltage drop than a conventional MPS rectifier, the Mo-MPS rectifier still exhibited a higher reverse breakdown voltage.

A Study on Joint Position at Concrete Pavement with Box Culverts (박스 암거가 통과하는 콘크리트 포장의 줄눈 위치에 관한 연구)

  • Park, Joo-Young;Sohn, Dueck-Su;Lee, Jae-Hoon;Jeong, Jin-Hoon
    • International Journal of Highway Engineering
    • /
    • v.14 no.2
    • /
    • pp.45-53
    • /
    • 2012
  • Hollows are easily made and bearing capacity is lowered near underground structures of concrete pavement because of poor compaction and long term settlement of the ground. Distresses occur and lifespan is shortened because of larger stress induced by external loadings expected than that in the design. In this paper, the distresses of the concrete pavement slab over box culverts were investigated at the Korea Expressway Corporation(KEC) test road. The transverse cracking of the slabs over the culverts was compared between up and down lines with different soil cover depth. The box culvert without soil cover and concrete pavement were modeled and analyzed by the finite element method(FEM) to verify the transverse cracking at the test road. Wheel loading was applied after self weight of the pavement and temperature gradient of the concrete slab at Yeojoo, Gyeonggi where the test road is located were considered. Positions of maximum tensile stress and corresponding positions of the wheel loading were found for each loading combination. Joint position minimizing the maximum tensile stress was found and optimal slab length over the culverts with diverse size were suggested.

Development of Evaluation Model for achieving the Program Educational Objectives in KEC2005 (한국공학교육인증의 '프로그램 교육목표' 달성을 위한 평가 모형 개발)

  • Kim, Myoung-Lang;Yoon, Woo-Young;Kim, Bok-Ki
    • Journal of Engineering Education Research
    • /
    • v.11 no.2
    • /
    • pp.42-49
    • /
    • 2008
  • Though the 'Program Educational Objectives' is the first and important criterion in ABEEK's engineering education accreditation, exact meaning and implementation methods have not been understood well. It was often confused with 'Program Outcomes' and its implementation and evaluation methods do not reflected well on the concepts of "outcomes based and demand driven education". A new implementation model for 'Program Educational Objectives' has been developed using step by step application. The model explains the meaning of every step (phase), and key constituents in each phase. The specialization and CQI of the program could be satisfied by applying the model properly.

Modeling and Analysis of Power Consumed by System Bus for Multimedia SoC (멀티미디어 SoC용 시스템 버스의 소비 전력 모델링 및 해석)

  • Ryu, Che-Cheon;Lee, Je-Hoon;Cho, Kyoung-Rok
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.11
    • /
    • pp.84-93
    • /
    • 2007
  • This paper presents a methodology that accelerates estimating the system-level power consumption for on-chip bus of SoC platforms. The proposed power modeling can estimate the power consumption according to the change of a target SoC system. The proposed model comprises two parts: the one is power estimation of bus logics reflecting the architecture of the bus such as the number of bus layers, the other is to estimate the power consumed by the bus lines during data transmission. We designed the target multimedia SoC system, MPEG encoder as an example and evaluated power consumption using this model. The simulation result shows that the accuracy of the proposed model is over 92%. Thus, the proposed power model can be used to design of a high-performance/low-power multimedia SoC.

Feasibility Study the Assessment Factor of Quality Performance Index in Expressway Concrete Pavement (고속도로 콘크리트 포장에 대한 품질평가지수 평가인자의 적정성 검토)

  • Lee, Seung Woo;Kim, Gyung il;Ko, Dong Sig;Hong, Seung Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.133-141
    • /
    • 2017
  • Traffic volume increases according to highway expansion and industrial development which causes repetitive defect and durability degradation on pavement. The research of quality assurance system used abroad has introduced Korea. Korea Expressway Corporation (KEC) has developed a Quality Performance Index (QPI) that quantitatively assesses the level of quality of the final product, and practical applications. Assessment factor on concrete pavement consisted of pavement thickness, compressive strength, IRI and spacing factor. Assessment factor on concrete pavement is determined by empirical evaluation factor from abroad. In this study, analysis of evaluation factors of concrete pavement by using pavement life prediction simulation and measured data were evaluated with consideration of feasibility of the assessment factor. Pavement life, performance and durability are affected by pavement thickness, compressive strength, IRI and spacing factor in assessment factor on concrete pavement, QPI.

Implementation of BSCT $320{\times}240$ IR-FPA for Uncooled Thermal Imaging System (비냉각 열 영상 시트템용 BSCT $320{\times}240$ IR-FPA의 구현)

  • Kang, Dae-Seok;Shin, Gyeong-Uk;Park, Jae-U;Yoon, Dong-Han;Song, Seong-Hae;Han, Myeong-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.11
    • /
    • pp.7-13
    • /
    • 2002
  • BSCT 320${\times}$240 IRFPA detector module is implemented, which is a key component in uncooled thermal imaging systems. The detector module consists of two parts, infrared sensitive pixel array and read-out integrated circuit(ROIC). The BSCT 320${\times}$240 pixels are made by laser scribe process and 10-${\mu}m$ micro-bump to satisfy 50-${\mu}m$ pitch and 95-% fill-factor. The ROIC has been designed to electrically address the pixels sequentailly and to improve signal-to-noise ratio with single transistor amplifier, HPF, tunable LPF and clamp circuit. The fabricated hybrid chip of detector and ROIC has been mounted on the TEC built-in ceramic package for more stable operation and tested for lots of electrical and optical properties. The IRFA sample has shown successful properties and met with good results of fill-factor, detectivity and responsivity.

An Analysis on Service Usage of Traffic Information on the Expressway (고속도로 교통정보 서비스에 대한 이용실태 분석)

  • Oh, Dong-Seob;Oh, Young-Tae;Jo, Soon-Gee;Hong, Eun-Joo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.5
    • /
    • pp.12-25
    • /
    • 2009
  • The purpose of this study is to identify and analyze drivers' attitude related to usage of traffic information and traffic management service. A sample survey on Seohaeanseon Expressway(15), Gyeongbu Experssway(1), Youngdong Expressway(50) was conducted to analyze drivers' attitude ; sample size is 304 with 95% of confidence level and ${\pm}3.6%$ of sampling error. The analysis lists of drivers' attitude are usage of traffic information, awareness about information dissemination devices, and awareness about traffic control information related to LCS or RWIS. The results of this study is that drivers want pre-trip information, voice-based Hi-pass OBU, and fast incident management. According to the IPA, KEC's main consideration is a traffic flow improvement.

  • PDF

The structural properties of the $(Bi_xBa_{0.6-x}Sr_{0.4})TiO_3$[BBST] ceramics with the sintering temperature and addition of $Bi2O_3$ ($Bi2O_3$ 첨가량 및 소결온도에 따른$(Bi_xBa_{0.6-x}Sr_{0.4})TiO_3$[BBST] 세라믹스의 구조적 특성)

  • Nam, Sung-Pill;Lee, Sang-Chul;Lim, Sung-Su;Lee, Sung-Gap;Lee, Young-Hie
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.85-87
    • /
    • 2002
  • The $(Ba_xBi_{0.6-x}Sr_{0.4})TiO_3$[x=0.1, 0.2, 0.3] ceramics were prepared by conventional mixed oxide method The structural properties of the $(Ba_xBi_{0.6-x}Sr_{0.4})TiO_3$[x=0.1, 0.2, 0.3] ceramics with the sintering temperature($1200^{\circ}C,\;1250^{\circ}C,\;1300^{\circ}C$) were investigated by XRD, SEM, EDS. Increasing the sintering temperature, the intensity of the $Ba_{0.5}Sr_{0.5}TiO_3$ (100), (110), (111), (200), (310) peaks and $SrBi_4Ti_4O_{15}$ (319), (040) peaks were increased. The gram of the $(Bi_{0.2}Ba_{0.4}Sr_{0.4})TiO_3$ ceramics sintered at $1250^{\circ}C$ were fine and uniform. Increasing the sintering temperature. the average gram size of the $(Bi_{0.2}Ba_{0.4}Sr_{0.4})TiO_3$ ceramics were decreased. The density of $(Bi_{0.1}Ba_{0.5}Sr_{0.4})TiO_3$ ceramics sintered at $1250^{\circ}C$ was 5.4524 [$g/cm^2$].

  • PDF

A Study on Graduate Attributes Assessment for K-EP (K-Engineering Professional) Qualification (K-EP(K-Engineering Professional) 자격을 위한 졸업생역량 평가방안 연구)

  • Choi, Se Hyu;Kang, Sang Hee;Kim, Jung Soo;Yoon, Jiyoung
    • Journal of Engineering Education Research
    • /
    • v.24 no.6
    • /
    • pp.30-39
    • /
    • 2021
  • The present study aims to demonstrate that it is possible to objectively evaluate the competency (referred to as graduate attributes or program outcomes) of graduates of engineering education programs. To strengthen the link between engineering education accreditation and the qualification/certification system of engineering professionals, referred to as K-Engineering Professional (K-EP), individually assuring the quality of accredited graduates using multiple-choice test as main assessment tool is proposed. Test questions related to the basic vocational skills of NCS are developed for seven of the 10 program outcomes of the ABEEK KEC2015. The three program outcomes, PO1, PO3, and PO5, which need to fully accommodate the characteristics of each disciplinary field, are excluded. A pilot test involving graduates of eight accredited programs is conducted. Applying on Rasch model based on Item Response Theory (IRT), the item difficulty, fit and discrimination of multiple choice test are demonstrated. The pilot study strongly suggests that individual competency evaluation is possible at a certain level for seven program outcomes tested. For PO1, PO3, and PO5, however, questions that address the characteristics of each disciplinary field need to be devised. If a suitable pool of questions is built, it can be used as a program outcomes assessment tool by the accredited programs.

Using an appropriate rotation-based criterion to account for torsional irregularity in reinforced concrete buildings

  • Akshara S P;M Abdul Akbar;T M Madhavan Pillai;Rakesh Pasunuti;Renil Sabhadiya
    • Earthquakes and Structures
    • /
    • v.26 no.5
    • /
    • pp.349-361
    • /
    • 2024
  • Excessive torsional behaviour is one of the major reasons for failure of buildings, as inferred from past earthquakes. Numerous seismic codes across the world specify a displacement-based or drift-based criterion for classifying buildings as torsionally irregular. In recent years, quite a few researchers have pointed out some of the inherent deficiencies associated with the current codal guidelines on torsional irregularity. This short communication paper aims to envisage the need for a revision of the displacement-based guidelines on torsional irregularity, and further highlight the appropriateness of a rotation-based criterion. A set of 6 reinforced concrete building models with asymmetric shear walls are analysed using ETABS v18.0.2, by varying the number of stories from 1 to 9, and the torsional irregularity coefficient of various stories is calculated using the displacement-based formula. Since rotation about the vertical axis is a direct indication of the twist experienced by a building, the calculated torsional irregularity coefficients of all stories are compared with the corresponding floor rotations. The conflicting results obtained for the torsional irregularity coefficients are projected through five categories, namely mismatch with floor rotations, inconsistency in trend, lack of clarity in incorporation of negative values, sensitivity to low values of displacement and error conceived in the mathematical formulation. The findings indicate that the irregularity coefficient does not accurately represent the torsional behaviour of buildings in a realistic sense. The Indian seismic code-based values of 1.2 and 1.4, which are used to characterize buildings as torsionally irregular are observed to be highly sensitive to the numerical values of displacements, rather than the actual degree of rotation. The study thus emphasizes the revision of current guidelines based on a more relevant rotation-based or eccentricity-based approach.