• Title/Summary/Keyword: Ke

Search Result 1,707, Processing Time 0.024 seconds

The Effect of Improvement of Temporomandibular Joint Movement Restriction using the Kaltenborn-Evjenth Orthopedic Manipulative Therapy (Kaltenborn-Evjenth 정형도수치료가 측두하악관절 운동제한 개선에 미치는 효과)

  • Kim, Sung-Won;Hong, Wan-Sung
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.2
    • /
    • pp.62-72
    • /
    • 2003
  • The purpose of this study is to prove the efficacy of the Kaltenborn-Evjenth Orthopedic Manipulative Therapy and the Conventional Physical Therapy that influence changes in pain and range of motion when those therapies are applied to patients with temporomandibular pint movement restriction. The subjects of the study were 30 randomly selected patients who had been diagnosed with temporomandibular pint movement restriction and had endured pain for more than two weeks. These patients had visited one of three hospitals in Pyongchon 00 Hospital. The subjects were divided into two groups with 15 patients each. The Kaltenborn-Evjenth Orthopedic Manipulative Therapy was applied to one group and the Conventional Physical Therapy was applied to the other group, once a day for three days. Then, the pain perception degree was measured by using the Visual Analogue Scale(VAS) and a digital device(Absolute Digimatic) measured the range of motion for each group. The average and standard errors were calculated for each measured items and a paired t-test was used for identifying significance in the differences in the pain perception degree and the range of motion between the two groups according to therapy. The significant level was set as ${\alpha}=0.05$. The changes in the pain perception degree were statistically significant in both groups; however, the group that received Kaltenborn-Evjenth Orthopedic Manipulative Therapy(KE-Group) showed more significant changes in a decrease in the pain perception degree than did the group that received the Conventional Physical Therapy(CPT-Group). Both groups showed significant results regarding changes in the range of motion: however, the KE-Group showed more of a significant difference in the average of the range of motion than did the CPT-Group(p<0.001). Comparing the changes in the range of motion between the two groups, the KE-Group showed a significant result which means that the KE-Group had a higher therapy effect than did the CPT-Group(p<0.05). Based on the results of this study, we found that the Kaltenborn-Evjenth Orthopedic Manipulative Therapy decreased pain and increased the range of motion. With such findings, we expect that the Kartenborn-Evjenth Orthopedic Manipulative Therapy can be used as an effective treatment method for patients with tempomrnandibular pint movement restriction and that the treatment period can be reduced with this therapy as well.

  • PDF

70nm NMOSFET Fabrication with Ultra-shallow $n^{+}-{p}$ Junctions Using Low Energy $As_{2}^{+}$ Implantations (낮은 에너지의 $As_{2}^{+}$ 이온 주입을 이용한 얕은 $n^{+}-{p}$ 접합을 가진 70nm NMOSFET의 제작)

  • Choe, Byeong-Yong;Seong, Seok-Gang;Lee, Jong-Deok;Park, Byeong-Guk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.2
    • /
    • pp.95-102
    • /
    • 2001
  • Nano-scale gate length MOSFET devices require extremely shallow source/drain eftension region with junction depth of 20∼30nm. In this work, 20nm $n^{+}$-p junctions that are realized by using this $As_{2}^{+}$ low energy ($\leq$10keV) implantation show the lower sheet resistance of the $1.0k\Omega$/$\square$ after rapid thermal annealing process. The $As_{2}^{+}$ implantation and RTA process make it possible to fabricate the nano-scale NMOSFET of gate length of 70nm. $As_{2}^{+}$ 5 keV NMOSFET shows a small threshold voltage roll-off of 60mV and a DIBL effect of 87.2mV at 100nm gate length devices. The electrical characteristics of the fabricated devices with the heavily doped and abrupt $n^{+}$-p junctions ($N_{D}$$10^{20}$$cm^{-3}$, $X_{j}$$\leq$20nm) suggest the feasibility of the nano-scale NMOSFET device fabrication using the $As_{2}^{+}$ low energy ion implantation.

  • PDF

Deposition of Copper Film on Polytetrafluoroethylene (PTFE) Modified by 1 keV Ion Irradiation (1 keV $Ar^+$이온빔으로 개질된 polytetrafluoroethylene (PTFE) 위의 구리 박막 증착)

  • Cho, Jun-Sik;Yoon, Ki-hyun;Koh, Seok-Keun
    • Korean Journal of Materials Research
    • /
    • v.10 no.1
    • /
    • pp.77-82
    • /
    • 2000
  • A surface of polytetrafluoroethylene(PTFE) was modified with changing ion doses by 1 keV $Ar^+$ ion irradiation and Cu films having thickness $5000\;{\AA}$ were deposited on the modified PTFE. The SEM study showed that the surface texture of modified PTFE was in the form of cones whose height increased depending on ion doses. Through XPS spectra, it was found that the intensity of F ls peaks decreased with ion doses by preferential sputtering of F atoms and the C-C and / or C-F chains were formed by the crosslinking in the newly unstable chains. Cu films were deposited uniformly along the filaments formed on the modified PTFE. In x-ray diffraction (XRD) spectra of deposited Cu films on modified PTFE, a preferred orientation along (111) and (200) planes was found and the peak intensity of (111) plane increased as surface roughness of modified PTFE increased. The resistivity of Cu films was changed from $2.7{\mu}{\Omega}cm$ of unmodified PTFE to $4.3{\mu}{\Omega}cm$ of modified PTFE at ion dose of $1{\times}10^{16}/\textrm{cm}^2$ and the abrupt increase of resistivity in the modified PTFE at ion dose of $1{\times}10^{17}/\textrm{cm}^2$ was due to being cut off the film which resulted from the increased surface roughness.

  • PDF

Characteristics of Shallow $P^{+}$-n Junctions Including the FA Process after RTA (RTA 후 FA 공정을 포함한 $P^{+}$-n 박막 접합 특성)

  • Han, Myeong-Seok;Kim, Jae-Yeong;Lee, Chung-Geun;Hong, Sin-Nam
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.5
    • /
    • pp.16-22
    • /
    • 2002
  • This paper suggests the optimum processing conditions for obtaining good quality $P^{+}$-n shallow junctions formed by pre-amorphization and furnace annealing(FA) to reflow BPSG(bore phosphosilicate glass). $BF_2$ions, the p-type dopant, were implanted with the energy of 20keV and the dose of 2$\times$10$^{15}$ cm$^{-2}$ into the substrates pre-amorphized by As or Ge ions with 45keV, 3$\times$$10^{14}$ $cm^{-2}$. High temperature annealings were performed with a furnace and a rapid thermal annealer. The temperature range of RTA was 950~$1050^{\circ}C$, and the furnace annealing was employed for BPSG reflow with the temperature of $850^{\circ}C$ for 40 minutes. To characterize the formed junctions, junction depth, sheet resistance and diode leakage current were measured. Considering the preamorphization species, Ge ion exhibited better results than As ion. Samples preamorphized with Ge ion and annealed with $1000^{\circ}C$ RTA showed the most excellent characteristics. When FA was included, Ge preamorphization with $1050^{\circ}C$ RTA plus FA showed the lowest product of sheet resistance and junction depth and exhibited the lowest leakage currents.

Neutron Capture Resonance Energy Identification of Indium by Time-of-Flight Method (중성자 비행시간법을 이용한 인듐의 공명에너지 동정에 관한 연구)

  • Lee, Sam-Yol
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.403-408
    • /
    • 2012
  • Prompt gamma ray from the natural Indium sample was measured by using an assembly of BGO($Bi_4Ge_3O_{12}$) scintillation detectors in the neutron energy region from 1 to 300 eV. The assembly was composed of pieces of BGO. The spectrometer was composed geometrically as total energy absorption detector. 46-MeV electron linear accelerator which is located at Research Reactor Institute, Kyoto University used for neutron sources from photonuclear reaction. The measurement of the neutron capture resonances was performed to below neutron energy 1 keV, because of strong X-ray effect from photonuclear reaction in Ta target and short distance from the target to an assembly of detector. The distance of neutron flight path is $12.7{\pm}0.02m$. The large neutron capture resonances were measured from 1 to 400 eV. The energy in the capture resonance was compared with the evaluated values. The large resonances were seen in the present measurement. General agreement can be seen between the present measurement and the previous evaluated data in relevant energy region. In the present study, we measured the continues resonance structure above 1 keV neutron energy region. 91.49 eV new neutron capture resonance was found in present measurement.

Multi-tracer Imaging of a Compton Camera (다중 추적자 영상을 위한 컴프턴 카메라)

  • Kim, Soo Mee
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.18-27
    • /
    • 2015
  • Since a Compton camera has high detection sensitivity due to electronic collimation and a good energy resolution, it is a potential imaging system for nuclear medicine. In this study, we investigated the feasibility of a Compton camera for multi-tracer imaging and proposed a rotating Compton camera to satisfy Orlov's condition for 3D imaging. Two software phantoms of 140 and 511 keV radiation sources were used for Monte-Carlo simulation and then the simulation data were reconstructed by listmode ordered subset expectation maximization to evaluate the capability of multi-tracer imaging in a Compton camera. And the Compton camera rotating around the object was proposed and tested with different rotation angle steps for improving the limited coverage of the fixed conventional Compton camera over the field-of-view in terms of histogram of angles in spherical coordinates. The simulation data showed the separate 140 and 511 keV images from simultaneous multi-tracer detection in both 2D and 3D imaging and the number of valid projection lines on the conical surfaces was inversely proportional to the decrease of rotation angle. Considering computation load and proper number of projection lines on the conical surface, the rotation angle of 30 degree was sufficient for 3D imaging of the Compton camera in terms of 26 min of computation time and 5 million of detected event number and the increased detection time can be solved with multiple Compton camera system. The Compton camera proposed in this study can be effective system for multi-tracer imaging and is a potential system for development of various disease diagnosis and therapy approaches.

Analysis of Photon Characteristics and Absorbed Dose with Cone Beam Computed Tomography (CBCT) using Monte Carlo Method (몬테칼로 기법을 이용한 CBCT의 광자선 특성 및 선량 분석)

  • Kim, Jong-Bo;Kim, Jung-Hoon;Park, Eun-Tae
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.161-169
    • /
    • 2017
  • The cone beam computed tomography(CBCT) which can acquire 3-dimensions images is widely used for confirmation of patient position before radiation therapy. In this study, through the simulation using the Monte Carlo technique, we will analyze the exposure dose by cone beam computed tomography and present the standardized data. For the experiment, MCNPX(ver. 2.5.0) was used and the photon beam spectrum was analyzed after Cone beam was simulated. As a result of analyzing the photon beam spectrum, the average energy ranged from 25.7 to 37.6 keV at the tube voltage of 80 ~ 120 kVp and the characteristic X-ray energy was 9, 60, 68 and 70 keV. As a result of using the water phantom, the percentage depth dose was measured, and the maximum dose appeared on the surface and decreased with depth. The absorbed dose also decreased as the depth increased. The absorbed dose of the whole phantom was 9.7 ~ 18.7 mGy. This is a dose which accounts for 0.2% of about 10 Gy, which is generally used for radiation therapy per week, which is not expected to have a significant effect on the treatment effect. However, it should not be overlooked even if it is small compared with prescription dose.

Study of 4π Compton Suppression Spectrometer by Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 4π 컴프턴 억제 분광기 연구)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.123-129
    • /
    • 2017
  • Compton suppression apparatus using the Compton scattering response, by inhibiting part of the spectrum Compton continuum Compton continuum in the area of the peak analysis of the gamma rays that enables a clearer device. In order to find out the geometry structure of high-purity germanium detector(HPGe) -NaI(TI) and to optimize the effect of movement, Monte Carlo simulation was used to grasp the behavioral characteristics of Compton suppression and compare several layout structures. And applied to the cylinder beaker used for the environmental measurement by using the efficiency according to the distance. For the low-energy source such as 81 keV, the Compton continuum is scarcely developed and the suppression effect is also insignificant because the scattering cross-section of the Compton effect is relatively low. In the spectrum for the remaining energy, it can be seen that the Compton continuum part is suppressed in a certain energy range. Compton suppression effect was not significantly different from positional shift. average reduction factor(ARF) value was about 1.08 for 81 keV and about 1.23 for 1332.4keV energy at the highest value. It can be seen that suppression over the Compton continuum region of the energy spectrum is a more appropriate arrangement. Therefore, it can be applied to various environmental sample measurement through optimized structure.

Absorbed Spectrum Comparison of Lead and Tungsten in Continuous X-ray Energy using Monte Carlo Simulation (몬테카를로 시뮬레이션을 통한 연속 엑스선 에너지에서 납(Pb)과 텅스텐(W)의 흡수 스펙트럼 비교 연구)

  • Kim, Kyotae;Kang, Sangsik;Noh, Sicheul;Jung, Bongjae;Cho, Changhoon;Heo, Yeji;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.483-487
    • /
    • 2012
  • In 1895, the discovered X-ray is used for not only in this field of medicine wide but also field. The detection of radiation after, people realized the risk of the radiation exposured recommended the principle about the protection of radiation by the part of the effort for lowering the radiation exposure. In this recommendation, all unnecessary radiation exposure have to be prevented by All doses include the protection of radiation, general idea of applicable two kinds of that it has to low maintain. Presently, in the General X-ray room of the clinical, the lead (Pb) was used for the shielding, However, because it had the problem of the lead poisoning which is fatal in the human body, the alternatives was showed. and Among them, the material that it is the tungsten was presented. in this research, the absorbed spectrum according to the thickness in the continuous X-ray energy of the tungsten which is not harmful to the human body through the Monte Carlo simulation, tried to compare with the absorbed spectrum of the lead (Pb). The tungsten confirmed that simulation presumption than result lead in the whole domain that absorbed probability was higher and it is considered that tungsten shows the absorbed efficiency higher than the lead in particularly, 70 keV ~ 90 keV and the tungsten is more useful to the X-ray energy cover of the high energy diagnostic area.

Electrodeposition of some Alpha-Emitting Nuclides and its Isotope Determination by Alpha Spectrometry (몇가지 알파입자 방출 핵종의 전해석출 및 알파 스펙트럼 측정에 의한 그의 동위원소 정량)

  • Key-Suck Jung;In-Suck Suh
    • Journal of the Korean Chemical Society
    • /
    • v.27 no.4
    • /
    • pp.279-286
    • /
    • 1983
  • An apparatus was made for the electrodeposition of alpha emitting actinide nuclides, $^{207}Bi$ and $^{210}Po$. The electrodeposition was made on a polished stainless steel plate cathode. The anode was made of platinum wire and to stir the solution. With the ammonium chloride as electrolyte initial pH = 4, chloride concentration = 0.6M and solution volume = 15ml, a current of 1.5 ampere(current density = 0.59A/$cm^2$) was flowed for 100 minutes for the quantitative recovery of electrodeposition and on average recovery of 98.3% was obtained within ${\pm}$0.7% uncertainty. Alpha spectrometry of the electrodeposited sample showed alpha peaks from $^{210}Po, ^{234}U$ and $^{239}Pu$ having energy resolution (FWHM) of 18.3, 21.8 and 36.0 keV respectively. The electrodeposition and alpha spectrometry for a natural uranium sample of domestic origin gave $^{238}U : ^{234}U = 1 : 6.1{\times}10^{-5}$ and for a neutron-irradiated uranium sample did $^{238}U : ^{239}Pu : ^{241}Am = 100 : 0.0263 : 5.20{times}10^{-5}$. The result of $^{238}U$ determination in the irradiated sample by electrodeposition-alpha spectrometry was in accord within ${\pm}1.6%$ of relative error with the results of solid fluorimetry and mass spectrometry. For $^{239}Pu$ the result of electrodeposition-alpha spectrometry was in accord within ${\pm}$4.0% of relative error with the results of anion exchange separation and the thenoyltrifluoroacetone(TTA) extraction both followed by alpha spectrometries.

  • PDF