• 제목/요약/키워드: KS Certification

검색결과 64건 처리시간 0.022초

전처리 방법에 따른 경화콘크리트 전염화물량 측정의 정밀도 향상을 위한 실험적 연구 (An Experimental Study on Precision Improvement of Chloride Ion Estimation of Hardened Concrete with Method of Sample Preparation)

  • 김영선;남정수;김영덕;조봉석;김규용;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.557-560
    • /
    • 2006
  • Worldwide, Certification systems for standard of material and quality of product exist very variously. Korean industrial Standard (KS) is most representatively certification systems in Korea. But laboratory of korea uses often ASTM, RILEM and JIS and these standards do not get into unionization. so, Granted that experiment is same, result still can different. Therefore, this research measured chloride amount of hardened concrete using identical material and wished to improve accuracy of chloride estimation as that comparison evaluate to each examination.

  • PDF

전자책 표준 적합성 도구의 개발 (Developing a Test Tool for Electronic Book Standard Conformance)

  • 김재경;손원성;임순범;김성혁;최윤철
    • 한국전자거래학회지
    • /
    • 제9권1호
    • /
    • pp.269-284
    • /
    • 2004
  • 한국문서형표준(KS X 6100)은 지난 2001년 7월 제정된 한국전자책문서표준(EBKS1.0)이 2002년 7월 한국산업기술표준원의 산업표준심의를 거쳐 제정되었다. 그러므로 한국문서형표준에 기반하여 작성된 전자책 문서들은 표준의 목적과 명세를 준수하여야 하며 표준의 준수 여부를 판별하기 위해서 적합성 검사가 요구된다. 본 논문에서는 이러한 적합성 검사의 기준이 되는 적합성 조항(Conformance Clause)의 정의와 이에 따른 적합성 검사 도구(Conformance Testing Tool)를 개발하였다. 따라서 본 논문에서 정의된 조항들을 통하여 전자책 제작자들은 전자책표준의 목적과 명세에 보다 적합한 전자책문서들을 제작할 수 있으며, 서비스 제공자들은 적합성 검사 도구를 통한 자동화된 적합성 검사 절차를 사용하여 효율적인 적합성 검사가 가능하다.

  • PDF

냉동 컨테이너용 경질 폴리우레탄 폼 단열재 표준연구 (A Study on the Standardization of the Polyurethane Soft Foam for Thermally Insulated Container)

  • 이준혁;박용근;주아람;정용안;이순홍
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.108-114
    • /
    • 2017
  • According to an increase in demand for polyurethane soft foam for thermally insulated containers, the purpose of this study is based on redefining existing rigid polyurethane foam insulation KS standard which has been limited to building material-based authentication techniques. Since there are arising concerns of consumer rights and safety due to humidifier fungicides and urethane track incidents, there are elements to be further researched on rigid polyurethane foam insulation for refregerated containers. Thus, we reviewed the prior standards for rigid polyurethane foam insulation and verified the validity of certification testing method for the new standard with self-foamed polyurethane.

증속기 현장시험 국내 적용 사례 및 절차 분석 (Domestic Application and Procedure Analysis of Gearbox Field Test)

  • 이광세;강민상;김석우;이진재
    • 신재생에너지
    • /
    • 제16권4호
    • /
    • pp.23-32
    • /
    • 2020
  • The wind turbine gearbox has the longest downtime among other major turbine components such as blades, generators, and main bearings. Therefore, gearbox manufacturers conduct rig tests to evaluate conformity in terms of design and function. Rig tests, however, have limited similarity compared with atmospheric wind turbine operating conditions. Rig test conditions are thoroughly controlled and maintained by testers and the component certificates of gearboxes issued through the test cannot fulfill wind farm operator's requirements. Hence, certification bodies such as DNV-GL and UL require a mandatory gearbox field test report for type certification. The Korea Energy Agency (KEA) also introduced gearbox field test as a part of the KS type certificate in 2016, although it is optional . In this paper, gearbox field test procedures and requirements are introduced, and the first domestic application case of the test is reported. The field test was conducted with a 1.5 MW wind turbine gearbox located in Jeju as the test object.

조립형 비계 및 동바리 부재 기준에 관한 연구 (A Study on Standards for Components for Tied Post System Scaffolding and Shoring)

  • 문성오;이상열;윤예빈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.25-26
    • /
    • 2021
  • System scaffolding and shoring are temporary structures in which vertical members, horizontal members, bracing members and trusses are assembled and installed. In order to ensure quality and safety, the quality test shall be carried out in accordance with the Guidelines for Quality Management of Construction Works (MOLIT Notice No. 2020-750). The quality test method (national standard) for Components for tied post system scaffolding and shoring is based on the Korean standards (KS F 8021) and the Safety certification standards (MOEL Notice No. 2021-22). However, the two standards differ in some aspects such as performance standards and etc, so cause confusion when applying them on-site. In addition, the standard for truss are applied only to trusses for shoring and cannot be applied to trusses for scaffolding. Therefore, this study aims to unify the two national standards and establish realistic standards.

  • PDF

고내구성능을 갖는 해저터널 방화문 설계방안 및 성능시험 연구 (A study on design and performance test of fire door with high endurance performance in submarine tunnel)

  • 박상헌;황주환;최영환;안승주;유용호
    • 한국터널지하공간학회 논문집
    • /
    • 제20권2호
    • /
    • pp.331-346
    • /
    • 2018
  • 국내 고속철도 터널에 주요 방재시설물인 피난연결통로 방화문이 설치되고 있으나, 고속으로 통행하는 열차의 고압력으로 인하여 방화문에 강한 충격 및 장기간 진동으로 인하여 잦은 파손 및 유지보수가 발생되고 있다. 이러한 문제를 해결하기 위해 방화문 개선이 필요하나, 국내에서는 단순 KS F 2296 성능시험에 의한 인증서를 제출하여 설치되고 있다. 현재 국내에서는 사전에 이론적인 검토 없이 실규모 방화문 제작에 의한 단순 시험인증 여부로 개발 되다보니, 개선을 위한 고비용이 발생되고 있는 실정으로 사전에 구조적인 안전을 확보할 수 있는 설계방안의 검토가 필요하다. 따라서 본 연구를 통하여 피난연결통로 방화문 설계 및 성능개선 효율화를 위해 사전 구조 검토가 가능한 구조해석 연구를 수행하였으며, 이러한 결과 값에 대한 신뢰성을 확보하기 위해 실규모 시작품 제작을 통한 공인 인증시험(KS F 2296)에서 발생된 결과 값을 비교검토 하였다.

현장 실무자 대상 조사에 의한 건설공사 품질관리 관련 만족도에 관한 고찰 (Satisfaction Level of Construction Quality Management by Survey of The Field Staffs)

  • 박형근
    • 한국건설관리학회논문집
    • /
    • 제10권2호
    • /
    • pp.34-45
    • /
    • 2009
  • 우리나라 건설공사의 품질관리체계는 관련법에 근거한 규정의 조합과 시공자가 구축한 ISO/KS A 9001에 의한 품질경영 시스템의 운용에 의한 방법의 혼합형이다. 이 두 가지의 품질확보체계는 상호 보완적이며 통합된 체계로 운영되어야 하나, 시공자의 품질경영시스템을 활용하지 못하고 법에서 정한 기준과 방법, 절차 등의 규정에 따라 모든 공사에 있어서 일상화된 품질관리업무가 수행되고 있다. 이러한 현상은 ISO규격이 도입된 이래 지난 10여 년간 계속된 문제점으로 개선이 요구되고 있다. 품질관리의 철저를 목표로 고객 만족을 위한 예방적 품질관리사고를 정착하는 일은 건설산업의 당면과제이다. 이에 본 논문에서는 건설현장 의 실무자를 대상으로 품질관리 관련 의식에 관한 설문조사를 실시하였으며 그 결과를 토대로 건설공사 품질관리 체계의 운용에 대한 만족도를 정리하고, 나아가 향후의 개선방안에 대한 논점을 제시하고자 한다.

내화뿜칠재 보와 기둥의 내화성능 분리평가에 대한 실험적 연구 (Experimental Study on Separate Evaluations of Fire Resistance of SFRM for Steel Beams and Columns)

  • 전수민;김재준
    • 한국화재소방학회논문지
    • /
    • 제29권4호
    • /
    • pp.1-6
    • /
    • 2015
  • 강구조용 내화뿜칠재는 내화구조로 인정을 받아야 사용할 수 있는데 내화뿜칠재 인정시 보와 기둥이 분리되어 평가 및 인정되고 있다. 보와 기둥의 내화시험 표준시험체는 단면형상계수 등이 상이하므로 내화피복 두께산정방법(KS F 2848)에 따르면 동일피복재를 사용하는 경우 동일성능의 보용 뿜칠재와 기둥용 뿜칠재는 피복두께가 상이할 것으로 예상할 수 있다. 그러나 현재 인정이 유효한 내화뿜칠재의 보 기둥 피복두께는 제품별로 서로 동일하거나 매우 유사하다. 그렇다면 동 뿜칠재의 내화구조 인정을 위한 성능시험시 보와 기둥의 강재평균온도에 차이가 있었을 것이라고 추정해 볼 수 있다. 본 연구를 통하여 보용 또는 기둥용 내화뿜칠재의 강재평균온도를 비교분석하여, 보용 기둥용으로 분리하여 평가 및 인정하고 있는 현 제도를 검토해 보고자 한다.

기후변화에 따른 낙뢰사고 예방을 위한 제도 방안 연구 (A Study on the Prevention of Lightning Accidents According to Climate Change Response)

  • 주석원;김성빈;이동호
    • 한국가스학회지
    • /
    • 제24권4호
    • /
    • pp.48-55
    • /
    • 2020
  • 낙뢰 보호 시스템의 설치는 증가하고 있으나, 피해량은 여전히 줄지 않고 있다. 이 연구에서는 피뢰시스템의 안전관리 방안의 제도적 개선을 위한 목적으로 피뢰시스템에 관한 기준을 파악하고 현장조사와 설문을 통해 피뢰 시스템의 설치, 운영, 유지보수 등 실증분석을 실시했다. 국가표준 KS C IEC 62305에서 정하고 있는 기준 및 규정을 만족하지 못하는 것으로 파악되며, 이러한 문제를 해결할 수 있도록 국가적인 차원에서 피뢰시스템의 안전인증제품 관리, 안전기준의 설계·제작·시공 등 관리 기준이 이행 될 수 있도록 관련 규정 재정립을 통한 안전관리 방안을 제시한다.

아크릴계 내화도료 연소가스의 유해성 평가와 배기온도에 대한 고찰 (Review of Hazard Test of Combustion Gas and Exhaust Temperature of Acrylic Fire Protection Paint)

  • 전수민;김재준
    • 한국화재소방학회논문지
    • /
    • 제31권4호
    • /
    • pp.1-6
    • /
    • 2017
  • 국내 건축물에 사용되는 내화도료는 품질시험을 통하여 내화구조로 인정받아야 사용할 수 있다. 품질시험은 내화시험 및 부가시험이며 내화도료의 부가시험 항목은 가스유해성과 부착강도이다. 이중 가스유해성의 경우 관련 KS 등에 따라 동물실험을 하며 매건 16마리의 살아있는 쥐가 희생된다. 이에 실험자는 윤리적 부담을 느끼게 되며 실험기관은 관련 법률에 따른 실험동물운영위원회 운영 등 행정적 부담을 지게 된다. 이에 연소 가스의 성분 분석을 통한 유해성 측정 등 상기 동물실험을 대체하려는 연구와 노력이 지속되고 있으나 현재까지는 동물실험이 유지되고 있다. 연소가스의 유해성 평가 시 시험체 가열에 따라 발생하는 배기온도가 측정되는데 특정 타입 내화도료에 대한 배기온도를 분석하여 유의한 초기 반응 양상을 파악할 수 있다면 동물실험 대체에 기여할 수 있을 것이라 사료된다. 이에 본 논문을 통하여 가스유해성 시험 시 쥐의 행동정지시간과 배기온도와의 관계를 파악하여 현 동물실험의 개선점을 찾아보고자 하였다.