Moisture Absorption and Desorption Properties of Douglas Fir, Hinoki, Larch, Plywood, and WML Board in Response to Humidity Variation

  • PARK, Hee-Jun;JO, Seok-Un
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.488-502
    • /
    • 2020
  • In this study, the moisture absorption and desorption properties presented by the Health-Friendly Housing Construction Standards of South Korea were compared using the wood of three tree species (Douglas-fir, Hinoki, Larch) and two types of wood-based materials(Plywood, WML Board). The national standards for functional building materials present that the amounts of moisture absorption and desorption should be at least 65g/㎡ on average, respectively according to the test method under KS F 2611:2009. Therefore, in this study, the moisture absorption/desorption properties of materials with no treatment (Control), with punching, and with surface stain finishing and the moisture absorption/desorption property improvement effects of the treatments were compared and analyzed. According to the results of this study, it was evaluated that all five types of wood and wood-based materials tested did not satisfy the amount of moisture absorption/desorption of at least 65g/㎡, which is the performance standard for moisture absorption/desorption functional building materials, indicating that untreated wood and wood-based materials cannot be applied as functional finishing materials according to the Health-Friendly Housing Construction Standards. The surface stain finishing greatly reduced the moisture absorption and desorption rates of the materials, and the amounts of moisture absorbed and desorbed were also shown to decrease by at least two times on average. When the surfaces of the materials were punched with Ø4mm holes at intervals of 20 mm, the moisture absorption/desorption areas increased from 18% to 51%, and this increase was shown to be capable of increasing the amounts of moisture absorbed/desorbed by 29% on average at the minimum, and 81% on average at the maximum. The effects of punching were shown to be identical even in cases where the materials were stain finished. For the application of wood or wood-based materials as eco-friendly, health-friendly, and moisture absorption/desorption functional building materials hereafter, it is judged that new physical and chemical improvement studies should be conducted, and treatment methods should be developed.

Preparation and Bonding Properties of Natural Garlic Adhesives for Wallpaper (벽지용 천연마늘접착제의 제조 및 접착성능)

  • Roh, Jeongkwan;Lee, Jinwha
    • Journal of Adhesion and Interface
    • /
    • v.12 no.4
    • /
    • pp.125-132
    • /
    • 2011
  • As the enhancement of indoor air quality is increasingly compelling the use of natural materials without any emission, this study reports the preparation and performance of natural garlic adhesives for wallpaper. The natural garlic adhesives were successfully prepared by the extraction of the clove of raw garlic with water to isolate carbohydrates and proteins. Properties of the prepared garlic adhesives such as the non volatile solids content, viscosity, density, and pH were 62%, 2,789 mPa.s, $1.3g/cm^3$, and 6.6, respectively. The non-volatile solids content has a great impact on the adhesion performance of the prepared garlic adhesives, which was adequate about 60%. Bonding strength of prepared garlic adhesives was greater than the requirement of a Korean standard for wallpaper. In addition, the garlic adhesives showed antibacterial activity inheriting from the garlic. It is expected that the prepared garlic adhesives could be used as safe and natural adhesives without emitting any volatile organic compounds and formaldehyde gas.

Sizing System Development of Korean Structural Firefighting Protective Clothing (한국 소방용 방화복의 치수체계 개발)

  • Han, Sul-Ah;Nam, Yun-Ja;Choi, Young-Lim
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.5
    • /
    • pp.827-839
    • /
    • 2009
  • Sizing system of Korean structural firefighting protective clothing that is national approved should be met for specification of structural firefighting protective clothing that is identified by Ministry of Public Administration and Security(MOPAS). However if you look over the specification of sizing system, the standard is based on only 'height' and the others are indicated as the size of completed product. KS K ISO 13688 and EN 340 which is met on ISO 13688 which indicates sizing system about protective clothing has the standards of height, chest and waist circumference. Also NFPA 1971 that has standards of sizing system is based on chest circumference, cervical to wrist length, waist circumference and inseam. That is different from Korean standards. Therefore, fire fighting protective clothing standards which is based on only height should be compensated and not be relied on foreign standards like ISO. It is indispensable for developing our own sizing system of structural fire fighting protective clothing. In this studying, Korean new sizing system of structural fire fighting protective clothing was developed for providing basic information of ergonomic structural fire fighting protective clothing. The analyzed target age was between 20 and 59 years old fire fighter who extinguish the fire. And it was analyzed by 3D measurement among data of the $5^{th}$ Size Korea. On conclusion, in case of structural fire fighting protective clothing coat, physical dimension was to be chest circumference, cervical to wrist length. Three dimensions as 5cm space of circumference and four dimensions as 2.5cm space of cervical to wrist length were derived, which means that totally 12 dimensions were defined. Dimension standards of pants was based on the analysis of waist circumference and crotch height. Six dimensions as 5cm space of waist circumference and three dimensions as 5cm space of crotch height were derived, which means that totally 14 dimensions were defined.

Review of Hazard Test of Combustion Gas and Exhaust Temperature of Acrylic Fire Protection Paint (아크릴계 내화도료 연소가스의 유해성 평가와 배기온도에 대한 고찰)

  • Jeon, Soo-Min;Kim, Jae-Jun
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.1-6
    • /
    • 2017
  • A fire resistance certification needs to be obtained before fire protection paint can be used in Korea. In the case of paint, the tests for certification are fire, gas hazard and bond strength. According to the hazard test standard of combustion gas, 16 mice are sacrificed every test. Therefore, there are ethical problems for the experimenter and legal problems for the laboratory. Accordingly, many alternatives are being assessed, such as combustion gas analysis, but they have not replaced animal testing yet. With gas hazard testing, the exhaust gas temperature can be measured. The property of the initial reaction of a specific fire paint can be characterized by this temperature. The purpose of this study was to consider the improvement point for a gas hazard test through comparative analysis of the exhaust temperature and the time of death of the mice.

Basic Properties and Dimension Stability of Ultra Rapid Setting Cement Mortar Containing Low-Quality Recycled Aggregate (저품질의 순환골재를 혼입한 초속경 시멘트 모르타르의 기초물성 및 부피안정성)

  • Jeon, Sang-Min;Kim, Hyeong-Ki
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.3
    • /
    • pp.246-252
    • /
    • 2021
  • The basic properties and volume stability of the ultra-rapid setting cement mortar containing low-quality recycled aggregate with a higher water absorption and lower specific gravity than relavent Korea Standard were experimentally confirmed. The mix proportion without recycled aggregate followed that of the general repair mortar used in the fields. 15% and 30% of the fine aggregate was substituted by the recycled aggregate in the mixtures with and without latex emulsion, and properties and characteristics of the mortar including mortar flow, setting time, compressive and flexural strength, and linear deformation under sealed and unsealed conditions were evaluated. It was confirmed that when low-quality recycled aggregate was used by 30%, there were risks of decrease in the early-age strength by up to 50% within 24h and increases in drying shrinkage by up to 2 times for 2 weeks compared to the the mixtures without the recycled aggregate.

Study of Characteristics of Clay Roof Tiles Using Ferro Nickle Slag Recycled Resources (페로니켈슬래그 순환자원을 활용한 점토기와의 성능평가)

  • Kim, Soon-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.4
    • /
    • pp.281-291
    • /
    • 2021
  • To reduce the environmental load of the construction industry, there is a need to minimize construction and demolition by strengthening the eco-friendliness of building materials and extending the durable lifespan. Therefore, while many Hanok roof finishing methods have been proposed to address these problems, the current trend is to use the existing method due to issues such as economic feasibility, weight, and durability. The manufacturing method of clay roof tiles used as roofing materials for Hanok buildings is optimized by using a mixture of 64.5% Gyeongju clay, 15.0% kaolin, 15.0% FNS(Ferro Nickel Slag), and 5.5% MAS(Magnesia Aluminum Silicate) under optimal conditions. The results of the experiment involving firing at 1,125℃ showed that flexural strength of 12,102N, which is higher than the standard of KS F 3510, an absorption rate of 6.08%, a volume specific gravity of 2.15g/cm3, and the freeze-thaw properties were satisfied. A method for securing stable quality was studied.

Designing of standard sizing system for hygienic masks (의약외품 마스크의 표준 치수 규격 개발)

  • Oh, Seol Young;Suh, Dong Ae
    • The Research Journal of the Costume Culture
    • /
    • v.30 no.4
    • /
    • pp.495-512
    • /
    • 2022
  • This study aims to design a new sizing system for hygienic masks to protect against COVID-19-related respiratory disorders. The product sizes were collected from 70 commercially available hygienic masks, and 18 head measurements were obtained from the three-dimensional (3D) scan data of 2,048 men and women aged 20 to 69 years from the 6th Size Korea Survey. The statistical analysis was performed using the IBM Statistical Package for the Social Sciences (SPSS) 28.0 program. The "bitragion-subnasale arc" and "menton-sellion length" were chosen as the key body dimensions for the hygienic mask sizing system. The linear regressions with 18 3D head measurements were analyzed, and it was determined that the key body dimensions were useful for statistically predicting other 3D head measurements related to hygienic masks. A new sizing system was proposed for two types of masks, "masks with a tight fit" and "masks with a loose fit," taking into account the existing Korean Industrial Standards (KS) and the shortcomings of the sizes of hygienic masks on the market. The sizing system for tight-fitting masks consisted of the key body dimensions, with their sizes indicated by a pair of numbers. The sizing system for loose-fitting masks consisted solely of the bitragion-subnasale arc, with their sizes denoted by letters such as S, M, and L (denoting small, medium, and large, respectively). Future studies should consider this mask sizing system for different age groups, such as children and adolescents.

Assessment of Practical Use of Recycling Oil from the Pyrolysis of Mixed Waste Plastics (혼합폐플라스틱의 열분해를 통한 회수오일의 이용가능성 평가)

  • Phae Chae-Gun;Kim Young-shin;Jo Chang-Ho
    • Journal of Energy Engineering
    • /
    • v.14 no.2 s.42
    • /
    • pp.159-166
    • /
    • 2005
  • In Korea, although the generation of waste plastic has been increasing, the rate of recycling is considerably low and moreover, there is no suitable method for the treatment of waste plastics. However, pyrolysis, which is appropriate for the treatment of highly polymerized compounds, such as plastics, has recently gained much interest. In this study, a property of the products from the pyrolysis of mixed waste plastics, with a possible practical use for the recycling oil produced, were assessed. First of all, in order to investigate the pyrolysis characteristic of waste plastics, TGA (Thermogravimetric analysis) and DCS (Differential Scanning Calorimetry) were performed on a number of different plastics, including PP, LDPE, HDPE, PET and PS, as well as others. According to the result, it appeared that PP was the most efficiently pyrolyzed by changing the temperature, followed by LDPE, HDPE, PET, PS and the other plastics, in that order. From the results, the optimum conditions f3r pyrolysis were set up, and the different waste plastics pyrolyzed. The recycling oil produced from the flammable gases generated during the pyrolysis was com-pared with fuel oil by an analysis using the petroleum quality inspection method on KS(Korea industrial Standard). The results of the analysis showed the recycling oil was of a similar standard to fuel oil, with the exception of the ignition point, with a quality somewhere between that of paraffin oil and diesel fuel. With respect to these results, the quality of the recycling oil produced by the pyrolysis of waste plastics was suf-ficient for use as fuel oil.

Nation-wide Interoperable transportation card X-CASH System and Settlement interface Development (전국호환 교통카드 X-CASH 시스템과 정산인터페이스 개발)

  • Lee, Ki-Han;Kim, Hye-Hyeon;Kim, Tae-Hee;Maeng, Jae-Hwan;Park, Ha-Na
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.5
    • /
    • pp.14-24
    • /
    • 2010
  • Although the existing X-CASH card system observes the KS standard for a transportation card system, there has been an issue for interoperability between X-CASH and other public transportation system due to the partially undefined part in the standard. This issue is followed by the inconvenience of the existing X-CASH users. If the existing X-CASH card user wants to get any other public transportations which are not interoperated with X-CASH, the user would have to buy other cards. Consequently, some users have to bring more than one card with them. In addition, it is almost impossible that the existing X-CASH system operator makes the X-CASH card available for the infrastructure built by other cards operators because their technologies are too much different. The X-CASH operator must construct its own infrastructure on the same route and it would cause an unnecessary loss of expense and labor. To solve these problems, We modified the existing X-CASH system and developed the Nation-wide Interoerable X-CASH system which lets both the existing X-CASH card and Nation-wide Interoperable X-CASH card work. This developed X-CASH system consists of the purchase SAM, the purchase terminal and the settlement. And The conformity test for it was successfully authorized. Also we, KORAIL NETWORKS, have done the test-bed on this Nation-wide interoperable X-CASH system in Gwangju for six months with Telecommunications & Clearings, the HiPlusCard Corporation. This test confirmed that the Nation-wide Interoperable X-CASH system would practically work well.

A Study on the Risk of Lightning in Special Structures and its Verification Method (특수 구조물의 낙뢰 위험도와 검증 방안에 관한 연구)

  • Yoo, Jeong Hyun;Kim, Hei Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.664-668
    • /
    • 2018
  • Free-standing structures that are especially high are more likely to receive brain attacks caused by lightning. Since special structures are generally part of national industrial structures, lightning strikes mostly cause socio-economic damage. Lightning protection facilities are installed to prevent such lightning damage, but in 2015, support cables on West Sea bridges were hit by lightning, causing a lot of economic damage. Accordingly, the design of a lightning protection system shall establish protective measures after analyzing the risk of debris falling onto the structure. In this thesis, lightning strikes are analyzed directly in relation to the modeling system that operates the actual information collection system for lightning strikes, depending on the location of the tall, free-standing structures, and practical lightning hazard information is provided by a meteorological station. In addition, we propose monitoring and applying a probability correction rate to the calculation of the lightning risk based on the number of lightning strikes directly reaching the ground in order to obtain an effective lightning risk assessment.