• Title/Summary/Keyword: KS (Korea Standard)

Search Result 423, Processing Time 0.026 seconds

Study on verification of various national standards regarding phthalate testing in industrial products (공산품 중 프탈레이트류 함유량 분석법에 관한 국내외 표준의 검증 연구)

  • Song, Moon-Hwan;Cho, Young-Dal;Choe, Eun-Kyung;Myoung, Young-Chan
    • Analytical Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.178-189
    • /
    • 2012
  • As phthalates classified as toxic to reproduction category 2 and endocrine disrupting chemicals were more strictly regulated as Substances of Very High Concern (SVHC) for authorization in under EU REACH and considered as priority substances in RoHS II, standardization of phthalate testing method is now being proposed in IEC 62321 of IEC TC 111 and the 2nd revision of KS M 1991 is also finished. In order to assist standardization activities related to phthalating testing, solvent extraction part of existing national standards were compared and verified. Recovery of DEHP (diethylhexyl phthalate) from PVC (polyvinyl chloride) by Soxhlet extraction increased in the order of methanol, toluene, dichloromethane and hexane from 46.9% to 95.3% as measured by GC-MS. Optimum extraction time was verified to be 6 hours using hexane. Recovery of DBP (dibutyl phthalate), BBP (butylbenzyl phthalate), and DEHP from different matrixes such as PVC, nitro cellulose, ABS (acrylonitrile butadiene styrene). and EPDM(ethylene propylene diene monomer) rubber were evaluated to be more than 90% up to 99%. The detection limits of phthalates in solvent extraction followed by GC-MS analysis were 0.08~0.3 ${\mu}g/mL$ in solution and 8~30 mg/Kg in polymeric samples. GC-MS analyses of phthalates were carried out using different solvent extraction based on the EN 14372, ASTM D 7083, Japanese test method (MHLW 0906-4) and KS M 1991, proving that equivalent recoveries ranging from 98%~99% were obtained. DBP and DEHP were detected in three consumer products such as a child toy, a power cable and manicure with the amount of 22~1,910 mg/kg.

A Study on the improving ways for effective operation of ISO 37001 (ISO 37001의 효율적 운영을 위한 개선방안 연구)

  • Jun, Byoungho;Kim, Jaeyoung;Kang, Byunggoo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.16 no.3
    • /
    • pp.73-82
    • /
    • 2020
  • 'ISO 37001 - Anti-bribery Management Systems, one of the Business Ethics of Global Standards, is a new standard to help organizations fight bribery and promote an ethical business culture which was developed in 2016. ISO 37001 can provide the tools and systems to greatly reduce the risk and help organizations deal with it effectively if it does arise. After enforcing the Improper Solicitation and Graft Act, Korean government standardized ISO 37001 harmonizing International Standards into Korean Industrial Standards (KS) in 2017. It is meaningful in that Korean companies have localized regulation which applies to global standard anti-bribery management systems. About 100 organizations have adopted ISO 37001 as in the first half of 2019. So far many side effects of other ISO certifications have been recognized. Therefore, it is necessary to investigate the current status of ISO 37001 in Korea for effective operation and management. The primary purpose of this paper is to investigate the current status and problems of ISO 37001 in Korea. It can provide useful guidelines for improving ISO 37001 to manage bribe and corruption effectively.

Tensile Test for Lap Welded Joints of Rebars(SD400) (일반철근(SD400) 용접 겹침이음 인장실험)

  • Park, Won-Tae;Chun, Kyoung-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.5
    • /
    • pp.570-576
    • /
    • 2018
  • In reinforced concrete structures, the joints of ordinary rebars are usually lap joints, which are bound by binding wires with rebars, and mechanical joints by couplers. In domestic design standards (concrete design code), welded lap joints are restricted for ordinary rebars, but overseas standards allow welded lap joints of ordinary rebars through pre-heating. This study investigated the domestic and international standards/criteria and evaluated the fracture strength by performing the tensile test on the lap welded joint of SD400 grade rebars, which is used the most in the construction sites. The weld length of the specimen for weld lap joints is based on the minimum weld length (8d) given in the KS standard (KS B ISO 17660-1). According to AWS D1.4, the preheating temperature was set to $150^{\circ}C$ for D19 and below, and $260^{\circ}C$ for D22 and above. In the test results, the tensile strength of rebars with welded lap joints exceeded the required strength (125% of the yield strength) according to the concrete design code. To analyze the effect of preheating, the tensile strength of the welded rebars after preheating was not significantly different from that of the welded rebars without preheating. The carbon equivalent content (Ceq) of the rebars used in the test was 0.45% or less. Under AWS D1.4, no preheating is required if the carbon equivalent is less than 0.45%. All specimens with a welded lap length of 8d failed by a bar fracture. The effect of preheating was confirmed to be insignificant due to the low carbon equivalent of the rebar.

A Study on the Explosion Hazardous Area in the Secondary Leakage of Vapor Phase Materials Based on the Test Results and the Leak Rate According to SEMI S6 in the Semiconductor Industry (반도체 산업의 SEMI S6에 따른 실험결과 및 누출률을 기준으로 한 증기 상 물질의 2차 누출 시 폭발위험장소에 관한 연구)

  • Kim, Sang Ryung;Lim, Keun Young;Yang, Won Baek;Rhim, Jong Guk
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.15-21
    • /
    • 2020
  • Currently, in KS C IEC 60079-10-1, the leakage hole radius of secondary leakage is expressed as a recommendation. Underestimation of leak hole size can lead to underestimation of the calculated values for leak rates, and conservative calculations of leak hole sizes, which are considered for safety reasons, can be overestimated, resulting in an overestimated risk range. This too should be avoided. Therefore, a careful and balanced approach is necessary when estimating the size of leaking holes.Based on this logic, this study examines the stability by grasping the concentration inside the gas box when leaking dangerous substances as a result of experiments based on SEMI S6, an international safety standard applied in the semiconductor industry and The scope of explosion hazardous area was determined by applying the formula of KS C IEC 60079-10-1 according to SEMI F15 leak rate criteria and SEMI S6 leak rate criteria. Based on this, we will examine whether the exhaust performance needs to be improved as an alternative to FAB facilities that are difficult to apply to explosion hazards such as semiconductor industry.

Utilization of Charcoal as an Environmentally Friendly Building Materials (I) - Characterization of Building Materials Prepared with Charcoal - (목탄을 이용한 친환경 건축자재 이용기술(I) - 목탄으로 제조된 건축자재의 특성 평가 -)

  • Ahn, Byoung-Jun;Jo, Tae-Su;Lee, Sung-Suk;Paik, Ki-Hyon;Kim, Sun-Ik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.537-545
    • /
    • 2009
  • The objective of this study was to investigate potential usage of environmentally friendly building materials, liquid mortar and dry cement mortar mixed with charcoal, based on the test of their physical and chemical properties. From the test results of physical and chemical properties of the liquid mortar mixed with charcoal, liquid mortar containing over 20% of charcoal, the consistency viscosity and the non-volatile content met a standard requirement. Drying time was delayed with increase in charcoal contents in the liquid mortar, however they were fully cured within 60 minutes in all treated levels. Other properties were acceptable at standard requirement. From the results, it was found that the proper charcoal addition level to the liquid mortar was 25%. In the results on dry cement, it was found that samples containing 5% of charcoal showed the maximum compressive strength, whereas samples containing over 20% of charcoal did not reach the minimum requirement of KS standard. Water retention ability constantly increased as the charcoal ratio increased. The conventional dry cement mortar adsorbed 59.5% of it, in the test of adsorption rate on ammonia gas, whereas cement mortar containing 10% of charcoal showed 71.6% of ammonia gas adsorption.

A Study on Perception of Adoption of ISO 30301 Management System for Records Standard Certification (ISO 30301 기록경영시스템 표준 인증제도 도입에 관한 인식조사)

  • Kim, Hyo Sun;Kim, Ji Hyun
    • The Korean Journal of Archival Studies
    • /
    • no.42
    • /
    • pp.73-134
    • /
    • 2014
  • The ISO 30301 MSR Standards support successful management of organization while providing strategic plans to the issue of records management. In Korea, these standards are established as the national standard (KS) in May 2013, and also, there are actions being taken to adopt the certification of the ISO 30301 Standards. However, to adopt such certification, it is required that the certification operation system needs to be organized, as well as that the society in general should understand about records management. Accordingly, it is even more required an review on the adoption of the system. This study has the purpose in surveying a variety of stakeholders' perception for the adoption of ISO 30301 certification given the circumstance that the ISO 30301 certification is not yet adopted in Korea. For this purpose, the research is implemented through literature review and in-depth interviews. Firstly, the literature review looks at ISO 30301 standards and the concept of certification that is being carried out with the ISO 30301 Standards, and it discusses the necessity of the adoption of the relevant standards' certification. Secondly, there are in-depth interviews carried out to study for the adoption plan for the ISO 30301 certification. The participants to the interviews include five records and certification related experts and five records managers at public institutions whose records management is supervised by National Archives of Korea. Interview data was analyzed based on grounded theory methodology. This study will be able to provide significant implication to build a successful plan for the adoption of ISO 30301 certification by reviewing perception of professional and problem, strategy of this certification.

Comparative Analysis on Recommended Levels of Illumination in Korea·China·Japan: Focused on Recommended Levels of Illumination for Housing (한중일의 조도기준 비교분석 : 주택조도기준을 중심으로)

  • Song, DaeSun;Kang, HyeKyung;Jo, YoungMi;An, Okhee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.1-8
    • /
    • 2014
  • This study compared the recommended levels of illumination for housing. KS Recommended Levels of Illumination (KS A 3011) in Korea, Recommended Levels of Illumination (GB 50034-2004) in China and Recommended Levels of Illumination (JIS Z 9110) in Japan are compared. The results are as below. First, recommended levels of illumination used in Korea China Japan are suggested by different locations and activities. However, classification for application scope is set differently. There are 10 areas for classification used in Korea, 5 areas in China, and 13 areas in China. When medium levels for classification are included as classification level, total of 15 areas are used for classification in China. Second, when considering there are 15 areas of application scope in China for recommended levels of illumination, there are 7 areas that are commonly used in Korea China Japan. 7 areas include stadium, factories, hospitals, office, shopping center, houses and hospitals. Third, working surface is considered as the height for recommended levels of illumination in Korea China Japan. Korea and Japan consider all working positions, standing and sitting position, when deciding the height. However, China only considers the standing position. Fourth, application scope for recommended levels of illumination for housing are classified in 16 areas in Korea, 5 in China and 18 in Japan. Thus, the application scope for recommended levels of illumination in housing in Korea is similar to Japan. However, there are only 5 areas used in China such as living room, bedroom, dining room, kitchen and sanitary room. Fifth, recommended levels of illumination is classified in 3 levels such as Lowest-Moderate-Highest while China and Japan only have standard recommended levels of illumination. Sixth, when observing recommended levels of illumination by type of activities, Japan classified the activities in greatest detail followed by Korea and then China. Seventh, Recommended levels of illumination differs by each country.

Hygroscopic Property, Leaching Resistance and Metal Corrosive Efficacy of Wood Treated with Fire Retardants

  • Son, Dong Won;Kang, Mee Ran;Hwang, Won Joung;Lee, Hyun Mi;Park, Sang Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.2
    • /
    • pp.157-162
    • /
    • 2014
  • This study was conducted to examine the functionality of the fire retardant treated wood. The hygroscopic property, leaching resistance, metal corrosive efficacy and gas toxicity of retardant treated wood were analyzed. Sodium silicate was penetrated to the wood for making fire retardant treated wood. The subsequent treatment agents such as boric acid, ammonium borate, di-ammonium phosphate were treated after sodium silicate treatment due to fixation. As results for the test, the leaching resist was improved by subsequent treatment. The fire retardant combination such as sodium silicate, boric acid and di-ammonium phosphate showed high hygroscopic property, metal corrosive efficacy. The gas toxicity was also satisfied KS standard.

Verification of the Appropriateness of the Standard for Tunnel Luminance in the Threshold Zone Through a Full-scale Tunnel Driving Test (실 규모 터널 주행실험을 통한 터널 경계부 휘도 기준의 적정성 검증)

  • Park, Won Il;Cho, Won Bum;Jeong, Jun Hwa
    • International Journal of Highway Engineering
    • /
    • v.17 no.6
    • /
    • pp.105-115
    • /
    • 2015
  • PURPOSES : This study aimed to evaluate the appropriateness of safety with the standard for threshold zone luminance as specified in the Recommendation for Lighting of Traffic Tunnel, which has been widely adopted worldwide. METHODS : A driving test of the subject in a full-scale road tunnel was conducted. The adaptation luminance and threshold zone luminance, which should be known for the driver to perceive an object within stopping sight distance, were obtained. These values were compared with the adaptation luminance and threshold zone luminance obtained by the existing reduced model test and tunnel lighting standard that has served as a guideline for the current threshold zone luminance standard. RESULTS : According to this study, threshold zone luminance should be increased to at least 1.8 times the value proposed in the existing studies and to twice the domestic tunnel lighting standard (KS C 3703: 2014). CONCLUSIONS : The threshold zone luminance proposed in this study differs largely from that obtained from indoor tests and from the current tunnel lighting standard used worldwide; this difference may be attributed to the fact that the indoor tests did not incorporate driving workload, non-uniformity of luminance distribution in terms of sight, and factors that reduce the visibility of the driver, such as the light reflected into the driver's eyes. Hence, it is necessary to further review the factors that reduce the visibility of drivers approaching tunnels in order to determine the rational tunnel threshold zone luminance.

Effect of Water-Containing Conditions on Concrete Substrates on Defects of Polyurethane-based Waterproofing Materials (콘크리트 바탕면의 함수조건이 폴리 우레탄계 방수재 하자에 미치는 영향)

  • Lee, Gun-Cheol;Kim, Jae-Yeob;Kim, Young-Min;Hong, Sung-Rok;Kim, Young-Sam;Shin, Hong-Chol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • This study is to analyze the cause of the defects in polyurethane waterproofing, a material commonly used on the roof of buildings, and to determine if it has a relation with the curing conditions of humidity and temperature and the moisture content of the base structure. As a result, it was confirmed that the waterproofing coating did not adhere when the moisture content of the base plate was 10% or more. When the temperature and humidity conditions were 20℃ and 80%RH, none of the properties deteriorate but when the temperature was 40℃, 60%RH, air bubbles were formed on the surface, and at 40℃ and 80%RH, the basic properties of the dry coating film were less than the KS F 3211 performance standard.