• 제목/요약/키워드: KPX(Korea Power Exchange)

검색결과 66건 처리시간 0.024초

전력거래소 전력IT 후비시스템 이설에 따른 기대효과 (The Expectation Effects of Transferring the KPX Power IT Backup System)

  • 김철호;박문철;이익종;김용수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.405-406
    • /
    • 2008
  • To maintain reliable and stable power grid the Power Dispatch Center consists of two sections, primary and backup centers. It is necessary that the Backup Dispatch Center stay away from the primary center in case of emergency like terror and natural disaster. The Backup Dispatch Center operates transmission lines outside of Seoul metropolitan area and could perform main center's role when primary center lose control Without building a duplex Power IT system, it would be doubtful to operate both centers efficiently. This paper deals with primary and backup Power IT systems which run two Dispatch Centers and focuses on expectation effects of its duplex system and transferring the Backup system.

  • PDF

SPS의 보호동작과 우리나라 계통보호설비 현황 (Protection Actions of SPS and SPS in Korea Power System)

  • 박종영;박종근;추진부;장병태;강계희;양정재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.274-276
    • /
    • 2002
  • 긴급보호제어시스템(SPS, Special Protection System)은 일반적인 보호동작 범위를 벗어난 외란에 대해서 계통 전지역의 보호를 목적으로 하는 광역시스템 보호기술이다. 따라서 SPS는 외란 시에 계통 장비의 보호보다는 계통을 보호함으로써 전력 공급능력 향상에 주안점을 두게 된다. SPS는 자주 동작하지 않고 평소에는 대기 상태로 있으며, 긴급한 동작이 요구되기 때문에 많은 경우에 그 동작이 미리 결정되어 있다. SPS는 입력변수나 전력계통에의 영향에 따라 분류할 수 있는데, 입력변수에 따라서는 계통 응답에 기초한 SPS와 사고에 기초한 SPS로 나눌 수 있다. 발전기 탈락, 부하 차단이 SPS의 주요 보호 동작이며 이 외에 가스터빈이나 양수발전기 기동, AGC 제어, HVDC 고속전력변환, 분로기기의 자동스위칭 등의 제어 동작이 있다. 우리나라의 경우에는 주로 동기탈조 방지를 위한 발전기 탈락의 동작을 하는 SPS가 설치, 운전되고 있다.

  • PDF

전력거래소 차기시스템 Common Information Model 적용에 관한 연구 (A Study on the Application of CIM for KPX's next Control Center)

  • 박민령;최영민;이진수;이건웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.384-385
    • /
    • 2011
  • 전력거래소는 전력산업 국가전략과제 중 하나로 추진된 한국형에너지관리시스템(이후 K-EMS)의 개발(2005~2010)을 성공적으로 완수하였으며 이를 바탕으로 차기계통운영시스템(이후 차기EMS)의 설계 및 도입(2011~2014)을 위한 작업을 진행 중에 있다. 차기EMS는 EMS를 중심으로 신규 시스템과 기존 시스템이 통합, 연계되어 사용자가 필요한 데이터를 원활하게 제공할 수 있는 서비스 중심 인프라스트럭쳐를 지향하고 있으며 이를 구현하기 위한 주요 기술 중 하나로 전력계통 모델링을 위해 IEC 국제표준규격인 CIM(Common Information Model)을 적용하였다. CIM은 차기시스템의 핵심 설비인 차기EMS와 차기MOS 간 공통 플랫폼을 제공하여 시스템의 신뢰성 뿐 아니라 유지보수 비용 측면에서의 개선을 기대할 수 있다. 차기EMS는 CIM의 적용을 통해 CIM을 채택한 이 기종 시스템과의 연계를 위한 호환성 및 유연성을 가진 시스템으로 개발될 것이다.

  • PDF

에너지저장장치를 이용한 제주지역 풍력발전 한계용량 증대효과 분석 (Increasing Effect Analysis of the Wind Power Limit Using Energy Storage System in Jeju-Korea)

  • 김영환;김세호
    • 한국태양에너지학회 논문집
    • /
    • 제34권1호
    • /
    • pp.81-90
    • /
    • 2014
  • The Jeju-Korea power system is a small-sized network with a system demand ranging from a autumn minimum of 350MW to a summer peak of 716MW. Because Jeju island is well exposed to north-east winds with high speed, applications to connect to Jeju power system are flooded. Considering physical/environmental constraints, Jeju Self-governing Province has also target for the wind power capacity of 1,350MW by 2020. It amounts to two or three times of Jeju average-demand power and wind power limit capacity announced by Korea Power Exchange (KPX) company. Wind farm connection agreements will be signed to maximize utilization of wind resource. In spite of submarine cable HVDC connected to Korea mainland, Jeju power system is independently operated by frequency and reserve control. This study reevaluates wind power limit based on the KPX criteria from 2016 to 2020. First of all wind power generation limit are affected by off-peak demand in Jeju power system. Also the possibility capacity rate of charging wind power output is evaluated by using energy storage system (ESS). As a result, in case of using 110MWh ESS, wind power limit increases 33~55MW(30~50% of ESS), wind power constraint energy decreases from 68,539MWh to 50,301MWh and wind farm capacity factor increases from 25.9 to 26.1% in 2020.

소규모 재생발전사업자의 중개시장참여 촉진요인 분석 (Analysis of Factors Driving the Participation of Small Scale Renewable Power Providers in the Power Brokerage Market)

  • 이드미트리;배정환
    • 신재생에너지
    • /
    • 제18권3호
    • /
    • pp.32-42
    • /
    • 2022
  • Rapid spread of intermittent renewable energy has amplified the instability and uncertainty of power systems. The Korea Power Exchange (KPX) promoted efficient management by opening the power brokerage market in 2019. By combining small-scale intermittent renewable energy with a flexible facility through the power brokerage market, the KPX aims to develop a virtual power plant system that will allow the conversion of existing intermittent renewable energy into collective power plants. However, the participation rate of renewable power owners in the power brokerage market is relatively low because other markets such as the small solar power contract market or the Korea Electric Power Corporation power purchase agreement are more profitable. In this study, we used a choice experiment to determine the attributes affecting the participation rate in the power brokerage market for 113 renewable power owners and estimate the value of the power brokerage market. According to the estimation results, a low smart meter installation cost, low profit variations, long contract periods, and few clearances increased the probability of participation. Moreover, the average value of the power brokerage market was estimated to be 2.63 million KRW per power owner.

신경 회로망을 이용한 계통 한계비용 예측 (SMP Forecasting Using Artificial Neural Networks)

  • 이정규;김민수;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.389-391
    • /
    • 2002
  • This paper presents the System Marginal Price(SMp) forecasting implementation using backpropagation Neural Networks in Competitive Electricity Market. SMP is very important term to seek the maximum profit to bidding participants. Demand and SMP that necessary data for training Neural Networks, supplied from Korea Power Exchange(KPX). Statistic analysis about predicted SMP presents a part of consideration in end of this paper.

  • PDF

온도와 부하의 관계를 이용한 단기부하예측 (Short-Term Load Forecasting using Relationship of Temperature and Load)

  • 이경훈;이윤호;김진오;이효상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.272-274
    • /
    • 2001
  • This paper presents a model for short-term load forecasting using relationship of temperature and load. We made one-day ahead load forecasting model using hourly normalized load and 11 dummy variables that were classified by day characteristics such as day of the week, holiday, and special holiday.

  • PDF

전력수용가 정전비용 산출물 위한 설문조사 방법론에 관한 연구 (Research for the survey of method to serviced customer Interruption cost evaluation)

  • 박수만;김재철;문종필;배주천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.259-261
    • /
    • 2002
  • KEPCO(Korea Electric Power Corporation) has been management alone before some time. However through the electrical industry reorganization generation and KPX(Korea Power Exchange) were separated on 2001. A marketing and distribution part will be separated in the future. While many problem for appear in future. how to management for power system network is important. unfortunallity, electrical power industry is starting point right now. Thus, detail data is incomplete for this field and detail research for this field is required with distribution reorganazation. In this paper suggest for customer interruption cost compute method to establish a standard. The standard is need to security operation of power system network. The customer interruption cost compute method necessity of customer interruption cost compute method is minimizing process for total cost. As final total cost compute through the interruption cost compute, we can recognize investment point exactly. We cited foreign survey questions, because exactly matched survey questions for in the country circumstance is not exist. And process to survey performance suggest after modify for match in the country circumstance. Survey questions that suggested fer this paper are classified five categories. This paper suggests to detail survey questions and survey method before survey and suggest to how to customer interruption compute when survey data is ensured. Moreover this paper suggest to average interruption cost compute for residential customer using statistical method.

  • PDF

2010년 여름철 전력계통 최적 운영에 관한 연구 (A Study on the Optimal Operation of 2010 Summer Peak in Korea Power System)

  • 이성무;조종만;김규호
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1733-1740
    • /
    • 2010
  • KPX(Korea Power Exchange) predicts that summer peak load will be 70,700MW and system overload will be 150% from contingency analysis. This paper presents a method to operate power system at 2010 summer peak. about equipment variation, power system variation, analysis results of voltage stability, and the method to relief overload by comparing 2009 and 2010. Especially, transmission constraints to prevent global contingency in Korea power system and the role of SPS(Special Protection System) to prevent voltage collapse when fault occurs are introduced.

Elasticity of substitution of renewable energy for nuclear power: Evidence from the Korean electricity industry

  • Kim, Kwangil
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1689-1695
    • /
    • 2019
  • This study suggests a simple economic model to analyze electricity grid that consists of different power sources. The substitutability of renewable energy for nuclear power in Korean electricity transmission network is investigated by suggested model. The monthly data from January 2006 to December 2013 reported by Electricity Power Statistics Information System (EPSIS) of Korea Power EXchange (KPX) are used. To estimate the elasticities of substitution among four power sources (i.e. coal, natural gas, nuclear power, and renewable energy), this paper uses the trans-log cost function model on which local concavity restrictions are imposed. The estimated Hicks-Allen and Morishima elasticity of substitution shows that renewable electricity and nuclear power are complementary. The results also evidenced that renewable electricity and fossil fueled thermal power generation are substitutes.