• Title/Summary/Keyword: KNEE JOINT TORQUE

Search Result 94, Processing Time 0.026 seconds

Strength Evaluation of Sin91e-Radius Total Knee Replacement (TKR) (인공무릎관절의 단축법위 회전시 근력정가)

  • Wan, Jin-Young;Sub, Kwak-Yi
    • Journal of Life Science
    • /
    • v.14 no.3
    • /
    • pp.484-489
    • /
    • 2004
  • Artificial joint replacement is one of the major surgical advances of the 21th century. The primary purpose of a TKA (Total Knee Arthroplasty) is to restore normal knee Auction. Therefore, ideally, a TKA should: (a) maintain the natural leverage of the knee joint muscles to ensure generating adequate knee muscle moments to accomplish daily tasks such as rising from a chair or climbing stairs;(b) allow the same range of motion as an complete knee; and (c) provide adequate knee joint stability. Four individuals (2 peoples after surgery one year and 2 peoples after surgery three years) participated in this study. All they were prescreened for health and functional status by the same surgeon who performed the operations. Two days of accommodation practice occurred prior to the actual strength testing. The isometric strength (KIN-COM III) of the quadriceps and hamstring were measured at 60$^\circ$ and 30$^\circ$ of knee flexion, respectively. During isokinetic concentric testing, the range of motion was between 10$^\circ$ to 80$^\circ$ of knee flexion (stand-to-sit) and extension (sit-to-stand). for a given test, the trial exhibiting maximum torque was analyzed. A 16-channel MYOPACTM EMG system (Run Technologies, Inc.) was used to collect the differential input surface electromyographic (EMG) signals of the vastus medialis (VM), vastus lateralis(VL), rectus femoris (RF) during sit-to-stand and stand-to-sit tests. Disposable electrodes (Blue SensorTM, Medicotest, Inc.) were used to collect the EMG signals. The results were as follows; 1. Less maximum concentric (16% and 21% less for 1 yew man and 3 years mm, respectively) and isometric (12% and 29%, respectively) quadriceps torque for both participants. 2.14% less maximum hamstrings concentric torque for 1 year man but 16% greater torque for 3 years mm. However, 1 year man had similar hamstring isometric peak torque for both knees. 3. Less quadriceps co-contraction by 1 year man except for the VM at 10$^\circ$-20$^\circ$ and 30$^\circ$-50$^\circ$ range of knee flexion.

Effect of Exoskeleton Orthosis for Assistance of Dorsiflexion Torque in Walking Pattern and Lower-limb Muscle (족배굴곡 보조용 외골격 보조기가 보행자의 보행패턴 및 하지근육에 미치는 효과)

  • Oh, H.J.;Kim, K.;Jeong, G.Y.;Jeong, H.C.;Kwon, T.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • In this study, the exoskeleton orthosis for the assistance of dorsiflexion torque in ankle joint to prevent foot-drop was developed. It was consist of three part; 1) the power part using artificial pneumatic actuator, 2) wearing part of ankle and knee joints to fix the orthosis, and 3) control part to detect the gait phase using physiological signal. The dorsiflexion torque was generated by the artificial pneumatic actuator connected with wearing part between ankle and knee joint. The accurate timing to assist dorsiflexion torque is made up of physiological signal in foot sole part that detect the gait phase, that is, stance and swing phase in each foot. We conduct the experiment to investigate the effect of exoskeleton orthosis to the 7 elderly people and 10 healthy people. The result showed that the muscular activities in tibialis anterior muscle were reduced because of the assistance of dorsiflexion torque in ankle joint using the exoskeleton orthosis.

  • PDF

Comparison of Effects among Tai-Chi Exercise, Aquatic Exercise, and a Self-help Program for Patients with Knee Osteoarthritis (슬골관절염 환자를 위한 타이치운동, 수중운동과 자조관리프로그램의 효과비교)

  • Lee Hea-Young
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.3
    • /
    • pp.571-580
    • /
    • 2006
  • Purpose: This study was to compare the effects among Tai-Chi exercise, aquatic Exercise, and a self-help program for knee osteoarthritis patients on symptoms of arthritis, muscle strength, balance, and difficulty of performing activities. Method: There were 50 final subjects50. A non-equivalent pretest-posttest design was used. The collected data was analyzed using SPSS for Window. One-way ANOVA and Scheffe's multiple comparison test were used 8weeks after each program. Result: There were significant differences in joint pain(p=.000), stillness (p=.001), knee extensor peak torque(p=.006), knee flexor(p=.002), and difficult of performing activity (p=.000), but there was no significant difference in balance(p=.648). The Tai-Chi group was significantly different from the self-help group for knee extensor peak torque, knee flexor and stiffness on Scheffe's multiple comparison tests. In addition, the Tai Chi group or aquatic group were significantly different from the self-help group for difficulty of performing activities(p<0.05). Conclusion: There are significant differences in the effects of the nursing intervention among the three groups. The Tai Chi group and aquatic group were significantly different from the self-help group. However, it seems that Tai-chi exercise may be more suitable than aquatic exercise in osteoarthritis exercise programs. Further studies with a longitudinal study are necessary to confirm the longer exercise period.

The Effects of Knee Brace on Anterior Cruciate Ligament Injuries Risk Factors During One-Legged Landing of Female Gymnasts (여자 체조선수들의 한 발 드롭 착지 시 무릎보호대가 전방십자인대 부상 위험요인에 미치는 영향)

  • Lim, Bee-Oh;Kim, Kew-Wan;Seo, Jung-Suk
    • 한국체육학회지인문사회과학편
    • /
    • v.51 no.4
    • /
    • pp.419-425
    • /
    • 2012
  • The purpose of the study was to investigate the effects of knee brace on anterior cruciate ligament injuries risk factors during one-legged landing of female gymnasts. Eleven female gymnasts were recruited and performed randomly one-legged drop landing in height of her's knee with (3times) and without (3times) knee brace. Kinematics and ground reaction data were collected to estimate the anterior cruciate ligament injuries risk factors. Data were analyzed with paired samples t-test. Female gymnasts with knee brace showed more reduced the distance from ankle joint center to knee joint center in sagittal plane and knee maximum joint torque than without knee brace. In conclusion, Female gymnasts with knee brace reduced anterior cruciate ligament stress.

Comparative Analysis on Muscle Function and EMG of Trunk and Lower Extremity in Short and Long Distance Athlete (육상 단거리 선수와 장거리 선수의 체간과 하지의 근기능 및 근전도 비교 분석)

  • Jung, Jae-Hu;Kim, Jung-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.9-16
    • /
    • 2012
  • The purpose of this study was to compare and analyze muscle function and EMG of the trunk and the lower extremity in short and long distance athletes and in order to determine difference in peak torque per unit weight, muscle power per unit weight, endurance ratio, and %MVIC classified by muscle. For that purpose, isokinetic muscle function tests for waist, knee, and ankle joints and EMG measurements for the trunk and the lower extremity muscle with running motion were conducted for 7 short and long distance high school athletes respectively. The study over muscle function of waist, knee, and ankle joints indicates that peak torque per unit weight of short distance athletes is higher than that of long distance athletes in extension and flexion of waist joint, plantar flexion of right ankle joint, and dorsi flexion of left ankle joint. In case of the muscle power per unit weight of short distance athletes is also higher than long distance athletes in waist, knee, and ankle joints. No difference in endurance ratio of waist, knee, and ankle joints between the two groups was founded. The results of the test over EMG of the trunk and the lower extremity show that %MVIC of erector spinae, rectus femoris, vastus medialis, vastus lateralis, and tibialis anterior is higher than that of long distance athletes in support phase. The above results proved to be the same in flight phase except for %MVIC of medial gastrocnemius. In other words, %MVIC of medial gastrocnemius for short distance athletes turned out to be higher than that of long distance athletes in flight phase.

Study on Advanced Knee Joint Linkage of Active Prosthesis Leg (진보된 능동 의족 무릎 관절 구조 연구)

  • Bak, J.H.;Lee, K.H.;Lee, C.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.2
    • /
    • pp.9-14
    • /
    • 2012
  • In this study, an advanced knee joint for active prosthesis leg driven by a linear actuator is suggested. The structure of knee joints of existing active prosthesis legs consists of three links. This kind of linkage requires large torque to drive the active prosthesis legs. Thus a new linkage structure is suggested to solve such problem in this paper. Motion characteristics of the suggested linkage are examined in the simulation. The motion simulation results show that the proposed linkage is able to imitate human gait cycles with the half of linear actuator speed in existing linkages.

  • PDF

Design of Robotic Prosthetic Leg for Above-knee Amputees (대퇴 절단자들을 위한 로봇 의지의 설계)

  • Yang, Un-Je;Kim, Jung-Yup
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.10
    • /
    • pp.913-922
    • /
    • 2014
  • This paper describes design of a robotic above-knee prosthetic leg which is powered by electrical motors. As a special feature, the robotic prosthetic leg has enough D.O.F.s. For mimicking the human leg, the robotic prosthetic leg is composed of five joints. Three of them are called 'active joint' which is driven by electrical motors. They are placed at the knee-pitch-axis, the ankle-pitch-axis, and the an! kle-roll-axis. Every 'active joint' has enough torque capacity to overcome ground reaction forces for walking and is backlashless for accurate motion generation and high-performance balance control. Other two joints are called 'passive joint' which is activating by torsion spring. They are placed at the toe part and designed by Crank-rocker mechanism using kinematic design approach. In order to verify working performance of the robotic prosthetic leg, we designed a gait trajectory through motion capture technique and experimentally applied it to the robot.

Effect of Correction to Muscle Imbalance in Lower Limbs according to Reduction of Weight Bearing Methods of Four Point of Horizontal Shaft (횡축 4정점 체중부하 감소기법 이용한 하지 근력불균형 개선에 미치는 효과)

  • Kang, S.R.;Kim, U.R.;Jeong, H.C.;Kwon, T.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.101-107
    • /
    • 2013
  • In this paper, we were to investigate effect of correction to muscle imbalance in lower limbs according to reduction of weight bearing methods of four point of horizontal shaft using two-belt treadmill. Participants were divided to two group according to each ten peoples who have difference of muscle function in left and right legs over 20%. Experiment progressed forty minutes a day three days a week, total four weeks and we estimated the maximal peak torque and average power for testing joint torque in hip, knee and ankle. The results showed that the correction effect of muscle imbalance to the maximal muscle strength was the most effective in hip joint. Also in knee joint, correction effect of muscular reaction was the most effective too. We thought that reduction of weight bearing methods could be positive effect to correct muscle imbalance in lower limbs.

  • PDF

Knee Joint Isokinetic Rehabilitation Exercise Equipment Usability Evaluation

  • Byoung-Kwon Lee;Seung-Hwa Jung;Hye-Ri Shin;Dong-Wook Han;Chang-Young Kim;Jong-Min Woo;Dae-Sung Park
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.4
    • /
    • pp.414-420
    • /
    • 2022
  • Objective: In this study, the test-retest reliability and validity were presented to evaluate the usability of isokinetic rehabilitation equipment for the knee joint. Design: Cross-sectional design, reliability & validity study. Methods: Thirty healthy adults participated in the study. A CSMI dynamometer was used as a standardized measuring device to present the validity of the equipment. It was measured based on the dominant leg. The average peak torque value was selected as the measurement variable. After the measurement, a questionnaire was conducted on safety, satisfaction, and performance through the usability evaluation questionnaire. Results: The knee joint isokinetic rehabilitation equipment showed high reliability with Intraclass Correlations Coefficients (ICC) =0.883~0.956. In order to check the validity of the equipment, the 95% confidence interval of the mean difference limit was confirmed by the Bland & Altman plot. As a result, all three angular velocities showed a smaller confidence interval in the flexion than in extension. There were less than 10 plots that were not included in 2 Standard Deviation (SD) between all measurements. As a result of the usability evaluation questionnaire, the average of the safety domain(4.9±0.4), satisfaction domain(4.1±0.8), performance domain(4.3±0.8). Conclusions: If the product is improved by supplementing the items identified in the usability evaluation process, it is judged that it can be used as a useful device in various knee joint rehabilitation fields.

Identification of Spastic Joint Pathologies using Isokinetic Movement (등속운동을 이용한 경직성 관절장애 정량화)

  • Lee Chang-Han;Heo Ji-Un;Kim Chul-Seung;Eom Gwang-Moon
    • Science of Emotion and Sensibility
    • /
    • v.7 no.4
    • /
    • pp.19-24
    • /
    • 2004
  • The purpose of this study is to evaluate the possibility of identifying joint damping property through commercially available isokinetic ergometer (BIODEX). The proposed method is to estimate the damping torque of the knee joint from the difference between the external joint torque for maintaining isokinetic movement and the gravity torque of the lower leg. The damping torque was estimated at various joint angular velocities, from which the damping property would be derived. Measurement setup was composed of the BIODEX system with an external force sensor and Labview system. Matlab was used in the analysis of the damping property. The experimental result showed that the small variation in angular velocity due to acceleration and deceleration of the crank arm resulted in greater change of inertial torque than the damping torque. Therefore, the estimation of damping property from the isokinetic movement is difficult.

  • PDF