• Title/Summary/Keyword: KMnO4

Search Result 171, Processing Time 0.021 seconds

Wet Chemical Process for Improving Air Quality in Semiconductor Manufacturing Process (반도체 생산공정의 대기질 개선을 위한 복합 대기오염물의 습식화학 제거공정)

  • Jun, Chang-Sung;Kim, Hak-Ju;Park, Young-Moo;Lee, Dae-Won;Ham, Dong-Suk;Jeon, Sang-Moon;Lee, Kwan-Young
    • Clean Technology
    • /
    • v.13 no.2
    • /
    • pp.109-114
    • /
    • 2007
  • In this study, we performed basic researches to develop wet purification system for improving air qualities of ventilation in semiconductor manufacturing process. Using 0.5 M aqueous solution of $KMnO_4$, 50 ppm of $NH_3$, SOx and NOx were reduced to 99% successfully. However, the removal of $O_3$ was limited to $22{\sim}30%$ for all the tested chemical solutionsincluding $KMnO_4$. Therefore, adoption of a dry ozone filter is necessary to reduce $O_3$ below a satisfactory level. For all the chemical solutions tested, NOx removal efficiency increased as NOx was mixed with $O_3$. As chemical solution was sprayed using water spraying system equipped with air atomizing type nozzle, the removal efficiencies of gaseous pollutants increased due to the increase of gas-liquid interfacial area.

  • PDF

Changes in BOD, COD, Chlorophyll-a and Solids in Aquaculture Effluent with Various Chemical Treatments

  • Park, Jeonghwan;Daniels, Harry V.
    • Journal of Marine Life Science
    • /
    • v.2 no.2
    • /
    • pp.49-55
    • /
    • 2017
  • Four chemical treatments with hydrogen peroxide (H2O2), copper sulfate (CuSO4), potassium permanganate (KMnO4) and chlorine (Cl2) were applied to the effluent pond water of a hybrid striped bass saltwater recirculating aquaculture system to compare their oxidation power. Four chemicals were applied at concentrations of 0 (control), 1, 5, 10 and 20 mg/l. An additional concentration of 40 mg/l was included in the chlorine treatment. Water samples from four hybrid striped bass ponds were tested with KMnO4 and Cl2. H2O2 did not reduce any of BOD, COD and chlorophyll-a, and copper sulfate was only effective on chlorophyll-a for the effluent pond. Removal efficiencies for chlorophyll-a by copper sulfate were 19.2%, 37.5%, 54.2% and 74.1% dose-dependently. Potassium permanganate effectively removed the BOD, COD and chlorophyll-a. The COD removal rates in four fish ponds varied from 15.9% to 31.6% at the concentration of 10 mg/l. Interestingly, Cl2 did not reduce the BOD and COD at all, but the BOD and COD instead increased drastically with increasing the Cl2 concentration. The pond water with the highest initial BOD and COD values among the fish ponds tested increased by 350% in the BOD and 150% in the COD at 20 mg/l. Furthermore, Cl2 did not significantly reduce any types of solid matter in this study, while KMnO4 seemed to reduce some extent volatile dissolved solid in the fish pond.

Characterization of Residual Lignins from Chemical Pulps of Spruce (Picea abies) and Beech (Fagus sylvatica) by KMnO4 Oxidation

  • Choi, J.-W.;Faix, O.
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.31-39
    • /
    • 2003
  • The enzymatic isolation of residual lignins obtained from spruce and beech pulps (obtained by sulfite, kraft, ASAM and soda/AQ/MeOH pulping processes) and their characterization was described in previous publications. Here, the residual lignins have been submitted to potassium permanganate oxidation (KMnO4 degradation), and 9 aromatic carboxylic acids (3 of them are dimeric) were identified after methylation with diazomethane by GC/MS. The analytical challenge during qantification by the internal standard methods was the partly high protein content of the samples, which resulted in elevated anisic acid yields in the degradation mixture of sulfite residual lignins. The results are compared with the KMnO4 degradation of the corresponding MWLs and discussed in terms of S/G ratios and degrees of condensation. The latter was calculated as a quotient between the aromatic carboxylic acids derived from condensed and non-condensed lignin structures. Typical degradation patterns for the various processes have been observed. Among other parameter, the relative compositions between iso-hemipinic acid (which is for condensation in pos. 5 of the aromatic ring) and meta-hemipinic acid and 3,4,5-trimethoxyphthalic acid (both are for condensation in pos. 6 of the aromatic ring) was found to be process specific. Kraft and soda/AQ/MeOH residual lignins yielded higher amounts of iso-hemipinic acid. In contrast, the relative yields of meta-hemipinic acid and 3,4,5-trimethoxyphthalic acid (the latter in beech lignins) are higher in sulfite and particularly in ASAM residual lignin. In case of beech residual lignins the amount of acids originated from non-condensed syringyl type lignin units was surprisingly high. The condensation degree of residual lignins was shown to be generally higher than that of MWLs. This was especially true for the G units. ASAM residual lignin exhibited very high S/G ratios and degrees of polymerization. Causality between condensation degree and total yield of degradation products was demonstrated.

The Characteristics of Groundwater quality in the Pusan Area (부산 지역 지하수의 수질오염 특성)

  • 정상용;강동환;심병완
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.86-92
    • /
    • 1998
  • 부산 지하수의 오염실태와 그 특성을 파악하기 위하여 1996년과 1997년에 분석된 지하수 수질자료 중에서 pH, TS, KMnO$_4$소비량, Cl, SO$_4$등을 통계분석 하였다. 각 성분의 평균치는 pH가 모두 7.3, TS는 216.0 mg/$\ell$와 242.3 mg/$\ell$, KMnO$_4$소비량은 2.6 mg/$\ell$와 6.3 mg/$\ell$, Cl은 35.7과 50.1mg/$\ell$, SO$_4$는 25.4와 33.9mg/$\ell$이다. 2년 동안 pH의 음용수 기준치 초과 비율은 0.55와 0.47%, TS는 1.89와 2.50%, KMnO$_4$소비량은 0.73과 1.17%, Cl은 1.41과 2.18%, 그리고 SO$_4$는 0.37과 0.86% 이다. 따라서 성분별로 비교해 볼 때, pH의 음용수 기준치 초과비율이 가장 적고, Cl의 초과비율이 가장 크다. Cl 및 SO$_4$이온의 음용수 기준치(각각 100 mg/$\ell$, 200mg/$\ell$) 초과지점과 이 이온들의 평균치보다는 훨씬 큰 100 mg/$\ell$이상되는 지점들의 분포를 분석한 결과, 해안가보다는 내륙에 더 많이 초과지점들이 분포한다. 따라서 부산지하수는 해수에 의한 영향보다는 내륙에서 생활하수나 기타원인(공장폐수, 오염된 하천수, 폐기물 매립 등)에 의한 오염이 훨씬 큰 것으로 보인다. 1996년에 5개 성분의 음용수 기준치 초과비율은 5.06%이고, 1997년의 초과비율은 6.87%로 전년도에 비하여 약간 증가하였다. 그러나 부산이 바다에 접하고 또한 인구과밀 지역임을 고려할 때, 부산의 지하수 수질은 양호한 편이다. 따라서 앞으로 부산 지하수의 보전 및 관리가 적절하게 진행된다면 부산에서 지하수는 시민의 생활용수로서의 역할을 증대해 나갈 수 있을 것이다.

  • PDF

Application of Geostatistical Methods for the Analysis of Groundwater Contamination in Pusan (부산지역 지하수 오염현황 분석을 위한 지구통계 기법의 응용)

  • 정상용;강동환;박희영;심병완
    • The Journal of Engineering Geology
    • /
    • v.10 no.3
    • /
    • pp.247-261
    • /
    • 2000
  • The geostatistical analyses for the chemical components of pH, TS, KMnO4 Demand, Cl, SO$_4$ and NO$_3$-N are carried out to understand the groundwater contamination in Pusan. The average values of each component are 7.2 for pH, 336.4mg/$\ell$ for TS, 2.3mg/$\ell$ for KMnO$_4$ Demand, 44.3mg/$\ell$ for Cl, 36.0mg/$\ell$ for SO$_4$, and 4.6mg/$\ell$ for NO$_3$-N. The ratios over the drinking standard of each component are 0.34% for pH, 2.27% for TS, 1.55% for KMnO$_4$ Demand, 1.59% for Cl, 0.57% for SO$_4$, and 3.7% for NO$_3$-N. The highest ratio of NO$_3$-N results from the municipal sewage and exhaust gas of vehicles. The isopleth maps of 6 chemical components show that the high values of groundwater contamination come from the inland of Pusan, and that some high values appear at the coastal area. The isopleth maps of Cl and SO$_4$ related with seawater intrusion also show that the high values appear only at the particular coastal area, not at the whole area. On the isopleth maps of Cl and SO$_4$, the anomalies of the concentration contours were compared with the directions of two large fault zones, the Ilkwang Fault and the Dongrae Fault. Apparently, they don't have the particular correlation. Therefore, it is concluded that the main source of groundwater contamination in Pusan is not the seawater, but the municipal sewage and other sources such as the exhaust gas of vehicles, the contaminated surface water, the waste water of factories, and the leachate of waste landfills.

  • PDF

Studies on the Sanitation of Potable Water in Farm Areas (목장지역 음용수의 위생학적 조사연구)

  • 박석기;이강문;김성원;임봉택;박성배;이용욱
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.1
    • /
    • pp.44-50
    • /
    • 1993
  • In order to investigate the hygienic conditions of potable water in farm area, we examined the hygienic bacteriological and chemical tests of the 159 waters in the farm areas of Kwangjugun, Namyangju-gun, Yangpyung-gun Paju-gun and Hwasung-gun.The results were as follows: 1. Of the 159 waters, the average numbers of standard plate count and coliform were 920 $\pm$ 250ml and 450 $\pm$ 380/100 ml, respectively. The average pH was 6.74 $\pm$ 0.08, KMnO$_4$ consumption 4.18 $\pm$ 0.23 mg/l, turbidity 0.74 $\pm$ 0.08 degree, NH$_3$-N 0.07 $\pm$ 0.02 mg/l, NO$_3$-N 7.76 $\pm$ 0.48 mg/l, total hardness 101.3 $\pm$ 4.7mg/l, chlorine 18.6 $\pm$ 1.3mg/l, sulfate 12.9 $\pm$ 1.0 mg/l, lead 0.036 $\pm$ 0.003 mg/l, manganese 0.017 $\pm$ 0.003 mg/l, zinc 0.064 $\pm$ 0.005 mg/l, and copper 0.010 $\pm$ 0.001 mg/l, respectively. 2. Of the 159 waters, 84 samples (52.8%) were over 100 per ml of SPC or detected coliform per 100 ml water and 63 samples (39.6%) exceed over physicochemical limited criteria for potable water. NO$_3$-N was the primary item among excess contents of potable water in farm areas. 3. The contents of total hardness, chlorine and NO$_3$-N in Hwasung-gun were higher than those in the other regions, but the numbers of SPC and coliform in Yangpyung-gun and Namyangjugun were higher than those in the other regions. 4. The correlationships among many items were highly significant (SPC, Coliform, KMnO$_4$ consumption NH$_4$-N, NO$_3$-N, KMnO$_4$, Total hardness, Chlorine, Sulfate).

  • PDF

The Clinical Trial of Quicure Vaginal Irrigation on Cenvico-Vaginitis (Quicure Vaginal Irrigation에 의한 자궁경부염 및 질염치료에 관한 임상적 연구(예보))

  • Whang, Dong-Hoon;Cho, Joo-Youn;Kwak, Hyun-Mo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.10 no.1
    • /
    • pp.45-55
    • /
    • 1983
  • This study was intended to investigate the effectiveness of Quicure vaginal irrigaticn for treatment of cervico-vaginitis. 53 patients who visited to severance hospital during July to December 1982 were included in this study. Antiseptics used for irrigation were 1% KMnO4, 10% Betadine and Albright solution, each solution was prepared for warm ($37^{\circ}C$) and cold ($15^{\circ}C$) form respectively, Acridine Orange immunofluorescent stainiry of cervico-vaginal smear was used for assessment of effectivenese. The results were as followed. 1. On unitial examination 62%s of patients had trichomonas infection, 19% had moniliasis infection, 19% had non specific infection. 2. Smear findings of patients~who had trichomonas infection or moniliasis infection, treated with cold 1% KMnO4 or Albright solution, became>negative except case of on each group. But the findings of all patients treated with warm solution became negative. Changes of findings of patients who had non specific infection showed similar result. This results indicated that warm solution would be better than cold solution. 3. The findings of all patients treated with Betadine solution became negative except, patient who had non specific infection, showed that Betadine solution would be better than 1% KMnO4 or Albright salution. 4. Patients' feeling of using warm saline was more satisfactory than that of cold solution

  • PDF

Determination of Optimun Coagulant Dosage for Effective Water Treatment of Chinyang Lake -The Effect of Coagulant Dosing on Remoaval of Colloidal Pollutants- (진양호소수의 효과적인 정수처리를 위한 최적응집제 주입량 결정 -콜로이드성 오염물질 처리를 위한 응집제 주입효과-)

  • 이원규;조주식;이홍재;허종수
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.761-772
    • /
    • 1998
  • This study was performed to determine the optimum coagulant dosing amount for effective treatment of raw water. The removal rate of turbidity and the variations of water qualities according to various dosage of coagulants such as Alum, PAC and PACS were investigated. The optimum coagulant dosing amount to make the lowest turbidity of water were 35mg/ι t of Alum, 30mg/ι of PAC and 10mg/ι of PACS in case of 5 NTU of raw water turbidity, and 30mg/ι of Alum, 25mg/ι of PAC and 10mg/ι of PACS in case of 10 NTU of that, respectively. The removal rates of turbidity at 4 min. and 8 min. of settling time were 10 and 72% of Alum, 44 and 62% of PAC and 25 and 55% of PACS in case of 5 NTU, and 52 and 70% of Alum, 90 and 95% of PAC and 10 and 28% of PACS in case of 10 NTU, respectively. Judging from the settling capability of floc., the reaction time of floe. formation and removal efficiency of turbidity, PAC was evaluated as more effective coagulant than Alum and PACS. Also PAC was regarded as the most effective coagulant when the water supply was changed sharply and the fluctuation of the surface loading occured with wide and sharp in settling basin. pH and alkalinity of the water were decreased with increasing coagulants dosage. But pH and alkalinity were not decreased below 5.8 which is the standard for drinking water quality, and 10mg/ι which is the limit concentration of floc. breakage, respectively. Residual Al of the treated water was decreased with increasing coagulants dosage in case of 5 and 10NTU of raw water turbidity. $KMnO_4$ consumption of the water was decreased with increasing coagulants dosage. The reduction rate of $KMnO_4$ consumption at the optimum coagulants dosage were 39% of Alum. 18% of PAC and 11% of PACS in case of 5 NTU of raw water turbidity, and 42% of Alum, 27% of PAC and 36% of PACS in case of 10 NTU of that, respectively. Any relationship was not found between the removal rate of turbidity and KMnO$_4$ consumption. TOC of the water was a bit decreased with increasing coagulants dosage up to 30mg/ι but not changed above 30mg/ι of coagulants dosage. The degree of TOC reduction was increased in the order of Alum, PAC and PACS treatment. Zeta potential of the colloidal floe. at the optimum coagulants dosage was in the range of -20~-15mV in case of 5 NTU of raw water turbidity and 0~0.5mV in case of 10 NTU of that. respectively. Although the kinds and dosages of coagulants were different, zeta potential range were fixed under the conditions of the best coagulation efficiency.

  • PDF

A Study on Characterization of THMs Formation in Tap Water in Daegu (대구수돗물의 THMs 생성특성)

  • Bae, Gi-Soo;Baek, Yoon-Kyung;Ryu, Ki-Sung;Shin, Sang-Hee;Lee, Chan-Hyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.12
    • /
    • pp.893-899
    • /
    • 2011
  • The occurrence of THMs, the characteristics of THMs formation and removal of THMs were investigated. The treatment train of M plant consists of prechlorination, flocculation, sedimentation, filtration, ozonation, activated carbon and postchlorination. The study of THM formation indicated that about 92% of the THMs were formed in the flocculation/sedimentation/filtration process which affected by prechlorination. The formation of THMs was highly correlated to $KMnO_4$ consumption and water temperature in raw water. The regression model had showed 0.72~0.80 of determination coefficient so it could be used to predict the amount of THMs formation in finished water. Compared to the prechlorination process, the THMs formation was reduced in interchlorination process. With the addition of PAC, fewer THMs were formed in PAC-chlorination process than in chlorination-PAC process. Our results showed that air stripping could be used to remove the existing THMs.