• Title/Summary/Keyword: KMnO$_4$

Search Result 172, Processing Time 0.037 seconds

A Study on Characterization of THMs Formation in Tap Water in Daegu (대구수돗물의 THMs 생성특성)

  • Bae, Gi-Soo;Baek, Yoon-Kyung;Ryu, Ki-Sung;Shin, Sang-Hee;Lee, Chan-Hyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.12
    • /
    • pp.893-899
    • /
    • 2011
  • The occurrence of THMs, the characteristics of THMs formation and removal of THMs were investigated. The treatment train of M plant consists of prechlorination, flocculation, sedimentation, filtration, ozonation, activated carbon and postchlorination. The study of THM formation indicated that about 92% of the THMs were formed in the flocculation/sedimentation/filtration process which affected by prechlorination. The formation of THMs was highly correlated to $KMnO_4$ consumption and water temperature in raw water. The regression model had showed 0.72~0.80 of determination coefficient so it could be used to predict the amount of THMs formation in finished water. Compared to the prechlorination process, the THMs formation was reduced in interchlorination process. With the addition of PAC, fewer THMs were formed in PAC-chlorination process than in chlorination-PAC process. Our results showed that air stripping could be used to remove the existing THMs.

An Experimental Study on the Chemical Values of the Tap Water in Seoul (서울시 수도수의 이화학적 수질조사)

  • 홍태용
    • Journal of Environmental Health Sciences
    • /
    • v.7 no.1
    • /
    • pp.21-31
    • /
    • 1981
  • This survey was carried out to investigate the temperature, pH value, nitrogen (ammonia, nitrite, nitrate), turbidity, color, chloride ion, $KMnO_4$ consumed, and hardness as chemical analysis of the tap water in Seoul city area during the period from September to Octobor, 1979, and to observe the differences among the values by the distance from the water purification plant and by the district supplied tap water from-the each water purification plant. The results obtained were as follows: 1) An average of the water temperature was $19.8\pm 0.2\circ$C. 2) An average of pH was $7.18\pm 0.02$. The difference among each district was statistically significant (p<0.01), but it was not observed among each distance. 3) An average of turbidity was $1.25\pm 0.12$ ppm. The difference among each district was highly significant (p<0.01), respectively, but not among each distance. 4) An average of color was $1.43\pm 0.16$ ppm, and there were statistically significant differences by the distance and by the district (p<0.01). 5) An average of ammonia nitrogen was $0.022\pm 0.005$ ppm. The differences among each distance, and district were statistically significant (P<0.01). 6) An average of nitrite nitrogen was $0.0050\pm 0.0013$ ppm, and the difference among each distance was highly significant (p<0.01), respectively, and each district showed statistical significance (p<0.01). 7) An average of nitrate nitrogen was $0.82\pm 0.08$ ppm. The difference among each district was significant (p<0.05), and each distance showed high significance (p<0.01). 8) An average of $KMnO_4$ consumed was $3.73\pm 0.16$ ppm, and the difference among each district was significant (p<0.05), but it was not observed among each distance. 9) An average of chloride ion was $8.56\pm 0.28$ ppm, and the difference among each district was higly significant (p<0.01), respectively, but it was not observed among each distance. 10) An average of hardness was $40.69\pm 1.17$ ppm, and there was statistically significant difference by each district (P<0.01), but not by distance. 11) The interrelation between temperature and pH of the tap water revealed the negative correlation from the coefficient of it as showed r=-0.6073 and p<0.01. 12) Except water temperature, there were negative correlationships between pH and other water qualities. 13) Correlation coefficients of $KMnO_4$ comsumed and ammonia nitrogen, nitrite nitrogen were statistically significant but that of $KMnO_4$ consumed and nitrate nitrogen showed no statistical correlationship. 14) Ammonia nitrogen seems to have high correlationship with nitrite nitrogen(r= +0.6669), but not with nitrate nitrogen. 15) Nitrate nitrogen seems to have statistically significant correlationship with nitrite nitrogen (r=+0.4959), but not with ammonia nitrogen. 16) The interrelation between chloride ion and hardness of the tap water revealed positive correlation from the coefficient of it as showed as r=+0.4888 and p<0.01.

  • PDF

The Study on the Relationship between Land Use and Groundwater Quality in the Rapidly Urbanized Area (도시화가 빠르게 진행된 지역의 토지이용과 지하수 수질과의 관계에 대한 연구)

  • An, Jung-Gi
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.1
    • /
    • pp.97-108
    • /
    • 2002
  • The use of land at the time of investigation of groundwater quality in the rapidly urbanized Bu-chon city is classified into 5 categories based on the change process of land use. The difference in groundwater quality according to the land use and its usage period is tested by non-parametric statistical procedures. The seven constituents of water quality with the highly frequent detection in the area for this study are used for the statistical test. The shallow groundwater quality within the areas of the same land use at the time of investigation varies significantly according to the period of land usage. The concentration of KMnO$_4$consumed and hardness is significantly higher in the old residential area (of more than 20 years old) than in the younger one (of less than 10 years old). The quality of the shallow groundwater is also significantly different among the three categories with the similar period of land usage (of more than 15 years old). The concentration of No$_3$-N, hardness and total solid is significantly higher in the residential area than in the agricultural one (namely, the area used as paddy fields 2 to 5 years ago). The median concentration of these constituents is 2.2 to 3.8 times higher in the residential area than in the agricultural one. The concentration of NO$_3$-N, KMnO$_4$, consumed and Cl is significantly higher in the industrial area than in the agricultural one. The median concentration of these constituents is 5.5 to 18 times higher in the industrial area than in the agricultural one. The concentration of KMnO$_4$consumed is significantly higher in the industrial area than in the residential area. The median concentration of these constituents is 12 times higher in the industrial area than in the residential one. The spatial distribution of shallow groundwater quality in the rapidly urbanized area is closely related to the period of land usage as well as the land use, which is presumed to be attributed to the difference in the concentration and leakage rate of the contaminants leaking from damaged sewer into shallow groundwater.

Effect of Drinking Water Treatment by DOF(Dissolved Ozone Flotation) System (DOF 공정에 의한 정수처리 효과)

  • Lee, Byoung-Ho;Song, Won-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.7
    • /
    • pp.743-750
    • /
    • 2008
  • In water treatment plant the Dissolved Ozone Flotation(DOF) System may be employed because this system has various abilities, such that it can remove SS using microbubbles, and it can exert strong oxidation power in removing taste and odor, color, and microbial agents. In order to investigate effectiveness of the DOF system in water treatment, removal characteristics of various water quality parameters were observed depending on the different levels of ozone concentrations. Removal efficiencies of water quality parameters in DOF system were compared with those in DAF(Dissolved Air Flotation) system and in CGS(Conventional Gravity Settling) system. Optimum ozone dose obtained in the pilot experiments was 2.7 mg/L. With increasing ozone dose higher than 2.7 mg/L, removal rates of turbidity, KMnO$_4$ consumption, UV$_{254}$ absorbance, and TOC were reversely lowered. High concentration of ozone dissociate organic matter in water, so that increasing dissolved organic level in effluent. Removal rates of water quality parameters at optimum ozone dose were obtained, such that removal rates of turbidity, KMnO$_4$ consumption, TOC, and UV$_{254}$ asorbance were 88.9%, 62.9%, 47%, and 77.3% respectively. Removal rate of THMFP was 51.6%. For all the parameters listed above, the DOF system was more effective than the DAF system or the CGS system. It is found that the DOF system may be used in advanced water treatment not only because the DOF system is more efficient in removing water quality parameters than the existing systems, but because the DOF system is also required smaller area than the CGS system for the treatment plant.

A Selective Determination Method of Inorganic and Organic Mercury (무기수은과 유기수은의 선택정량)

  • Kim, Chon Han
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.8
    • /
    • pp.392-398
    • /
    • 1997
  • A method of selective determination of inorganic and organic mercury compounds has been described. The $CHCl_3$ solution of a high molecular quaternary alkylammonium salt, Aliquat 336 was used for the simultaneous preconcentration of both inorganic, $Hg^{2+}$ as its thiocyanate complex, and organic mercury compounds, $CH_3HgCl$ and $C_2H_3O_2$ $HgC_6H_5$ by extraction from their aqueous solution. Selective separation of the inorganic mercury from the extract was followed by stripping with 3 M $HClO_4 $ solution for the subsequent determination by CVAAS. Organic mercury was also determined by CVAAS after removal of $CHCl_3solvent$ from the extract and decomposition of the residue with 4% $KMnO_4 $-1 MH_2$S0_4$. The mixtures of inorganic and organic mercury compounds contained 1.0 $\mug$ as Hg in 50 mL of sample solution(0.02 ${\mu}gHg/mL$) were analysed within ${\pm}6%$ by absolute errors.

  • PDF

Hydrothermal Synthesis of Li-Mn Spinel Nanoparticle from K-Birnessite and Its Electrochemical Characteristics (K-Birnessite를 이용한 Li-Mn Spinel 나노입자 합성 및 전기화학적 특성 평가)

  • Kim, Jun-Il;Lee, Jae-Won;Park, Sun-Min;Roh, Kwang-Chul;Sun, Yang-Kook
    • Applied Chemistry for Engineering
    • /
    • v.21 no.5
    • /
    • pp.590-592
    • /
    • 2010
  • Li-Mn spinel ($LiMn_2O_4$) is prepared by a hydrothermal process with K-Birnessite ($KMnO_4{\cdot}yH_2O$) as a precursor. The K-Birnessite obtained via a hydrothermal process with potassium permanganate [$KMnO_4$] and urea [$CO(NH_2)_2$] as starting materials are converted to Li-Mn spinel nanoparticles reacting with LiOH. The molar ratio of LiOH/K-Birnessite is adjusted in order to find the effect of the ratio on the structural, morphological and electrochemical performances of the Li-Mn spinel. X-ray diffraction (XRD) and field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDS), and thermogravimetry (TG) are used to investigate the crystal structure and morphology of the samples. Galvanostatic charge and discharge are carried out to measure the capacity and rate capability of the Li-Mn spinel. The capacity shows a maximum value of $117\;mAhg^{-1}$ when the molar ratio of LiOH/K-Birnessite is 0.8 and decreases with the increase of the ratio. However the rate capability is improved with the increase of the ratio due to the reduction of the particle size.

Sanitary Chemical Conditions of Farmwaters in Choongcheongnam and Kangwon Province According to Spring and Summer (충청남도 및 강원도 목장지역 목장용수의 춘하절간 위생화학적 변화)

  • 이강문;박석기;이용욱
    • Journal of Food Hygiene and Safety
    • /
    • v.9 no.4
    • /
    • pp.229-235
    • /
    • 1994
  • It is very important to investigate the sanitary chemical conditions of farmwaters used for cattle breeding in the dairy farms. For this purpose we examined pH, KMnO4 consumption, total hardness, chloride, sulfate, NH3-N, NO3-N, fluoride, lead, iron, manganese, cadmium, copper, zinc and chrome in the farmwaters sampled 2 times(spring and summer)in Choongcheongnam and Kangwon Province. The pH of farmwaters in Choongcheongnam and Kangwon Province was 6.49$\pm$0.09, 6.70$\pm$0.06, total hardness 90.21$\pm$7.07, 64.53$\pm$6.38 mg/ι, consumption of KMnO4 4.13$\pm$0.62, 4.34$\pm$0.26mg/ι, NO3-N 6.51$\pm$0.55, 3.61$\pm$0.58 mg/ι, chloride ion 20.51$\pm$1.99, 5.41$\pm$1.36 mg/ι and sulfate ion 6.61$\pm$1.02, 7.28$\pm$1.30 mg/ι, respectively. But NH3-N was scarcely detected. Fluoride, iron, lead, cadmium, zinc, manganese and chrome were not detected from the tested farmwaters. There was high significance between each other in total hardness, NO3-N, chloride ion and sulfate ion. There was regional and seasonal significance in only NO3-N but only regional significance in total hardness and chloride ion.

  • PDF

Study on the Water Quality of Bank Filtration Depending on Soil Characteristics (토양특성에 따른 강변여과수의 수질에 관한 연구)

  • Na, Hyeon-Young;Kwon, Dae-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.6
    • /
    • pp.19-26
    • /
    • 2011
  • In this research, soil analysis and adsorption were conducted, and compared with the water quality of bank filtration and river in terms of TS, TDS, SS, $NH_4$-N, $NO_3$-N, $NO_2$-N, Fe, Mn, BOD and $KMnO_4$ consumption for the development of bank filtration in Gimhae city. Analysis of soil showed high levels of Fe (470 mg/kg), Mn (80 mg/kg) and $NH_4$-N (15 mg/kg). Also, adsorption coefficient values (k and 1/n) were 0.00159 and 0.8714, respectively. This implies that the adsorption of the soil depends on organic matter. Water qualitiy of the river and the bank filtration revealed that the concentrations of TS and TDS almost didn't change but the concentration of SS decreased 84% through the bank filtration. $NH_4$-N in the bank filtration was detected more than 1 mg/L which might be due to agricultural activities in the research area. $NO_3$-N was close to the detection limit owing to the removal by the adsorption. $KMnO_4$ consumption and BOD of the river were decreased by the bank filtration 250% and 350%, respectively, while Fe and Mn were significantly increased by the bank filtration.

Titration methods of $H_2O_2$ in Cu/TaN CMP (Cu/TaN CMP시 $H_2O_2$ 적정방법)

  • Yoo, Hae-Young;Kim, Nam-Hoon;Kim, Sang-Yong;Kim, Tae-Hyung;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.38-41
    • /
    • 2004
  • The oxidizer plays an important role in the metal chemical mechanical polishing(CMP) slurry. Currently, the oxidizer used in CMP slurry is nearly divided into several kinds such as $Fe(NO_3)_3$, $H_2O_2$, $KIO_3$, and $H_5IO_6$. It is generally known that oxidizer character of $H_2O_2$ is more effective than other oxidizers. In this work, we have been studied the characteristics for the $H_2O_2$ concentration of copper slurry, which can applicable in the recent semiconductor manufacturing process. Also, it plays an important role in the planarization of copper films using copper slurries during micro-electronic device fabrication. In this work, we confirmed that removal rate of Cu/TaN changed by $H_2O_2$ concentration on copper slurry. And we used $KMnO_4$ in the measurement method of $H_2O_2$. In analysis results, we confirmed that the difference of results is large. We thought that the difference was due to organic component existence. So in titration method of $H_2O_2$ concentration, we used $Na_2S_2O_3$ instead of $KMnO_4$ as solution. Consequently, using the titration method, we could calculate correct data reduced error. And $H_2O_2$ concentration has been adjusted to the target concentration of 0.1 wt%.

  • PDF

Indicator 크리깅을 이용한 부산지하수 수질의 오염도 연구

  • 강동환;정상용;김병우;심병완;성익환;조병욱
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.249-253
    • /
    • 2003
  • 강서구를 제외한 부산 전지역에서 1998년도에 조사된 지하수 수질 중 6개 성분(pH, TS, KMnO$_4$, Cl, SO$_4$, NO$_3$-N)에 대한 일반통계분석 결과 pH 성분을 제외하고는 5개 성분의 중앙값이 평균보다 적은 값을 보이는 양성왜도를 보임으로써, 수질오염정도를 분석하기 위해 지시크리깅이라는 비모수적인 지구통계분석기법을 적용하였다. 6개 수질성분에 대해 음용수 기준치를 적용하여 음용가능은 “1”의 값이, 음용불가능은 “0”의 값이 주어졌다. 이렇게 변환된 자료를 이용하여 각 성분별로 실험적인 베리오그램 분석을 실시한 결과 pH, TS, SO$_4$ 성분은 선형모델이 선정되었으며, KMnO$_4$, Cl, NO$_3$-N 성분은 구상형모델이 선정되었다. 본 연구에서는 지시크리깅을 이용하여 6개 성분의 분포도를 작성하고 부산지역의 오염정도를 분석하였다. 지시크리깅기법은 연구지역 전체의 정량적인 분포를 나타내지는 못하지만, 오염의 유.무와 오염의 크기를 정확하게 파악할 수 있으며 또한, 이상치(outlier)가 크게 영향을 미칠 수 있는 통계학적인 오류를 보완할 수 있다.

  • PDF