• 제목/요약/키워드: KIT

검색결과 2,355건 처리시간 0.024초

Relationships Between C-Kit Expression and Mean Platelet Volume in Benign, Preneoplastic and Neoplastic Endometrium

  • Sehitoglu, Ibrahim;Bedir, Recep;Ural, Ulku Mete;Gucer, Hasan;Yurdakul, Cuneyt;Cure, Medine Cumhur;Cure, Erkan;Yuce, Suleyman;Sahin, Figen Kir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권4호
    • /
    • pp.1495-1499
    • /
    • 2015
  • Background: c-Kit is a proto-oncogene that encodes a tyrosine kinase receptor (CD117). Mean platelet volume (MPV) is a useful marker for demonstrating thrombocyte function. We aimed to investigate whether c-kit is expressed in benign, preneoplastic and neoplastic endometrial tissues and whether MPV has a relation with c-kit expression and its intensity. Materials and Methods: c-Kit expression was investigated immunohistochemically in 10 samples of normal endometrium (n=10), simple endometrial hyperplasia (5 cases with atypia and 10 cases without atypia), complex endometrial hyperplasia (10 cases with atypia and 10 cases without atypia) and endometrial cancer (EC) (10 cases grade I and 10 cases grade II) and MPV of all cases was checked. Results: c-Kit expression was observed at very low rates in cases with normal endometrial tissues (NE) and in hyperplasia without atypia. c-Kit expression and immunostaining were strong in endometrial atypia and EC. MPV levels of complex atypical endometrial hyperplasia (CAEH) (p:0.002), EC grade I (ECG I) (p<0.001) and EC grade II (ECG II) (p<0.001) were significantly elevated when compared with the NE group. Both c-kit expression and intensity of immunostaining had a positive correlation with MPV level. Conclusions: While c-kit expression and intensity of immunostaining were mildly positive in NE and hyperplasia without atypia, they were clearly observed in EC and hyperplasia with atypia. As c-kit expression is related to the mutagenesis a long-term followup may be needed in these cases. A high MPV level may be a good test for demonstrating c-kit expression and intensity of immunostaining.

A Digital logic design Triaing Kit with Print Port Emulation Function (프린트 포트제어 에뮬레이터 기능의 디지털 논리설계 훈련 키트)

  • 도외철;정완영
    • Proceedings of the IEEK Conference
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.911-914
    • /
    • 2003
  • A logic design training kit with print port emulation function was developed. The input device of the kit was 4$\times$4 key input and 6 FND(DYNAMIC) and LCD were used as out put devices and the output device were also can controlled by PC connectde by print port to the kit. The emulator was coded by Visual Programming C++(MFC)

  • PDF

A Study on DNA Polymorphism of the Bovine c-KIT Receptor Gene (소 c-KIT Receptor 유전자의 다형성에 관한 연구)

  • Jang, Y.S.;Kim, T.H.;Yoon, D.H.;Park, E.W.;Lee, H.W.;Lee, H.K.;Cheong, I.C.
    • Journal of Animal Science and Technology
    • /
    • 제44권6호
    • /
    • pp.653-660
    • /
    • 2002
  • We considered KIT gene as a candidate gene for the white-spotting pattern in cattle. This study was carried out to detect genetic variation of c-KIT receptor gene and to investigate association between the mutation and the white-spotting pattern in cattle. PCR-RFLP analysis within intron 6 of c-KIT receptor gene were performed with 8 cattle breeds including Hanwoo, Angus, Brown Swiss, Charolais, Hereford, Holstein, Limousin and Simmental. When PCR product of approximately 2,440 bp including intron 6 of c-KIT receptor gene was sequenced, four nucleotide substitutions were found within intron 6 of the bovine c-KIT receptor gene. In PCR-RFLP analysis, three alleles (A, B and C), two alleles (A and B) and two alleles (A and B) at each locus were identified by MspⅠ, BsrBⅠ and NdeⅠ, respectively. Although frequencies of allele at each locus were different among cattle breeds, we could not get any evidence related with white or white spotting phenotypes in these mutations on intron 6 of c-KIT receptor gene. However, we can not entirely exclude the possibility that c-KIT receptor gene is responsible for white spotting phenotype in cattle. Thus, further studies need to detect other mutations in c-KIT receptor gene and to test association of those mutations and coat color phenotypes in cattle.

Novel Mutation and Genetic Variation of the KIT Gene in Korean Wild Boars(Sus scrofa coreanus) (한반도 멧돼지 KIT 유전자의 유전적 변이와 신규 돌연변이)

  • Jo, In-Cheol;Choe, Yu-Rim;Go, Mun-Seok;Kim, Jae-Hwan;Lee, Jeong-Gyu;Jeon, Jin-Tae;Lee, Hang;O, Mun-Yu;Han, Sang-Hyeon
    • Journal of Animal Science and Technology
    • /
    • 제48권1호
    • /
    • pp.1-8
    • /
    • 2006
  • KIT encodes a mast/stem cell growth factor receptor and is known as a possible candidate gene responsible for dominant white coat color in mammals. To investigate the genetic variation of KIT gene in Korean wild boars(Sus scrofa coreanus), we carried out PCR-RFLP and DNA sequencing for three exons(exons 17, 19, and 20) and intron 19 of the KIT gene in Korean wild boars. PCR-RFLP results using NlaⅢ restriction enzyme in the breakpoint region between exon 17 and intron 17 and AciⅠ restriction enzyme in exon 19 indicate that Korean wild boars did not have previously identified white coat color related splicing mutation and missense mutation, respectively. These results also indicate matings between Korean wild boars could not give white coat color offsprings. We also found new SNPs in exons 19(C2661T) and 20(A2760G). Of these, the SNP in exon 20 is a missense mutation which might induce the change of amino acid iso-leucine to valine. However, no relationship was identified with this missense mutation and coat color. In this study, breed specific new SNPs were identified in exons 19, 20 and intron 19 and these results will give important information for genetic variation of porcine KIT gene.

Calibration Kit for 4-Port Horizontal/Vertical Probing (4-포트 수평/수직 겸용 프로브용 교정키트)

  • Kim, Taeho;Kim, Jonghyeon;Kim, Sungjun;Kim, Kwangho;Pu, Bo;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제25권5호
    • /
    • pp.559-575
    • /
    • 2014
  • In this paper, we propose a horizontal/vertical calibration kit for calibrating a vector network analyzer(VNA) to measure the vertical connector pin. If the conventional calibration kit is used, we should change the arm for a probe or need an assistant device and it takes a long time. In addition there is a risk of precision degradation caused by the position change of the probe tip sensitive to the surroundings. We suggest a 4-port vertical calibration kit to make up for the aforementioned shortcomings. The calibration kit was manufactured for the SOLT calibration method. 'Short', 'Open', and 'Load' are available in the horizontal plane, 'Thru' is available not only in the horizontal plane on the two planes of a PCB, but in the vertical plane between the two planes according to the positions of the probes. We complemented the conventional calibration kit to make a vertical calibration kit to be used for the vertical measurement method. We compared and analysed their reflection/transfer characteristics of the SOLT calibration standards of the proposed calibration kit and conventional one, we get a ${\pm}0.1$ dB differences of transfer characteristics in the range from 300 kHz to 8.5 GHz. In order to demonstrate usefulness, and we performed a case study for horizontal and vertical cases, and compared the results of the proposed calibration kit and conventional one.

Evaluation of Vi-Passive Hemagglutination, SD$^{(R)}$ Kit, and Widal Test for Serological Diagnosis of Typhoid Fever (장티푸스의 혈청학적 진단을 위한 Vi-수동혈구응집법, SD$^{(R)}$ Kit 및 Widal 시험에 대한 효용성 평가)

  • Kim, Sung-Hun;Kim, Shuk-Ho;Lee, Deog-Yong;Lee, Esther;Park, Mi-Sun;Lee, Bok-Kwon
    • Korean Journal of Microbiology
    • /
    • 제46권2호
    • /
    • pp.219-222
    • /
    • 2010
  • In this study, we evaluated Vi-passive hemagglutination (Vi-PHA), SD Salmonella Typhi IgG/IgM ($SD^{(R)}$ kit) and Widal test for the rapid laboratory diagnosis of typhoid fever patients. A total of 36 serum samples from febrile patients in Korea from 2005 to 2006 were used. Among 36 patients, 27 were fever patients without typhoid, 9 were typhoid fever. Vi-PHA showed 8 positive results out of 9 typhoid fever patients (sensitivity 88.9%) and 1 positive and 26 negative results out of 27 febrile patients without typhoid (specificity 96.3%). The sensitivity and the specificity of $SD^{(R)}$ kit were 100% and 92.6%, respectively. However, the sensitivity and the specificity of Widal O & H tests were 88.9%, 100%, and 77.8%, 70.4%, respectively. Consequently, Widal H and $SD^{(R)}$ kit showed higher sensitivity and Vi-PHA showed higher specificity. To efficient diagnosis, Vi-PHA may be sufficient diagnosis method in acute cases and $SD^{(R)}$ kit and Widal test may be sufficient in sporadic area and high risk group.

Type Analysis of Drug Intoxicated Patients in Daegu Emergency Medical Center and Medical Flexibility of Diagnostic Test Using Drug Addiction Selecting Kit

  • Lee, Seung-Jin;Lim, Soon-Ok;Kim, Tae-Jeong;Park, Min-Jeong;Ryu, Jong-Ha
    • Korean Journal of Clinical Laboratory Science
    • /
    • 제45권3호
    • /
    • pp.91-95
    • /
    • 2013
  • It is important to check the types of drugs when treating acute drug intoxication. This study researches the clinical characteristics and types of patients hospitalized in emergency medical center for drug addiction in 2009 and 2010. By applying a drug addiction selecting kit, it studied the flexibility and clinical efficiency during diagnosis and treatment. The study result shows, among the drugs causing addiction, Sedative accounts for 34.4%, Herdicide 23.5%, Analgesic 17.2%, Insectide 7.8% and else 17.2%. Sedative showed the highest proportion both in 2009 and 2010. Among the drug addicted patients, 39 cases did not know that the drugs are poisonous and among them, the drug addiction selecting kit was positive in 32 cases (82.0%). In 42 cases where addiction was suspicious, 25 cases (59.5%) were positive in the drug addiction selecting kit. In 57 cases of using drug addiction selecting kits, the cases in which benzodiazepine was positive, were 30 and the most frequently cases were as follows; Tricyclic Antidepressants (TCA) 13 cases, Amphetamines 3 cases, barbiturate 3 cases, and piate 3 cases. In the district using drug addiction kit meaningfully had Flumazenil injection much greater impact than the one not using the kit. This proves the efficiency of the kit (p<0.05). The uses of drug addiction selecting kits are for acute drug intoxicated patients and for providing objective and scientific information when emergency medical doctor are checking unchecked poisoning drugs. It is considered that drug addiction selecting kits would give help when treating the early stage of drug addicted patients in emergency medical treatment.

  • PDF

Dose-response Effects of Bleomycin on Inflammation and Pulmonary Fibrosis in Mice

  • Kim, Soo-Nam;Lee, Jin-Soo;Yang, Hyo-Seon;Cho, Jae-Woo;Kwon, Soon-Jin;Kim, Young-Beom;Her, Jeong-Doo;Cho, Kyu-Hyuk;Song, Chang-Woo;Lee, Kyu-Hong
    • Toxicological Research
    • /
    • 제26권3호
    • /
    • pp.217-222
    • /
    • 2010
  • Many studies have reported that bleomycin, anti-cancer drug, induces pulmonary fibrosis as a side effect. However, few investigations have focused on the dose-response effects of bleomycin on pulmonary fibrosis. Therefore, in the present study, we investigated the effects of different doses of bleomycin in male mice. ICR mice were given 3 consecutive doses of bleomycin: 1, 2, or 4 mg/kg in bleomycin-treated (BT) groups and saline only in vehicle control (VC) groups. The animals were sacrificed at 7 and 24 days postinstillation. The severity of pulmonary fibrosis was evaluated according to inflammatory cell count and lactate dehydrogenase (LDH) activity in the broncho alveolar lavage fluid (BALF), and lung tissues were histologically evaluated after hematoxylin and eosin (H&E), and Masson's trichrome staining. BT groups exhibited changed cellular profiles in BAL fluid compared to the VC group, which had an increased number of total cells, neutrophils, and lymphocytes and a modest increase in the number of macrophages at 7 days post-bleomycin instillation. Moreover, BT groups showed a dose-dependent increase in LDH levels and inflammatory cell counts. However, at 24 days after treatment, collagen deposition, interstitial thickening, and granulomatous lesions were observed in the alveolar spaces in addition to a decrease in inflammatory cells. These results indicate that pulmonary fibrosis induced by 4 mg/kg bleomycin was more severe than that induced by 1 or 2 mg/kg. These data will be utilized in experimental animal models and as basic data to evaluate therapeutic candidates through non-invasive monitoring using the pulmonary fibrosis mouse model established in this study.

Development of Rapid Diagnostic Technology for Pig Disease (2) - Rapid detection of PPE in the pig feces -

  • Kim, Hyuck-Joo;Hong, Jong-Tae;Yu, Byeong-Kee;Kim, Giyoung;Kim, Suk
    • Journal of Biosystems Engineering
    • /
    • 제38권2호
    • /
    • pp.121-128
    • /
    • 2013
  • Purpose: Porcine proliferative enteropathy (PPE), caused by the obligate intracellular bacterium Lawsonia intracellularis, is a widely distributed disease throughout the world causing substantial economic loss. In order to diagnose PPE rapidly, the rapid kit was developed and tested. Methods: In this study, a rapid kit was developed to screen the PPE rapidly at the pig farm. Also, occult blood test with fecal occult blood (FOB) kit was done for detecting the blood in pig feces which might be the evident of hemorrhagic PPE. For developing the kit, we tested fecal samples of PPE infected pigs diagnosed by polymerase chain reaction (PCR) method. Results: With the developed rapid kit, Lawsonia intracellularis was detected in high density emulsion of ileum. On the other hand, the test result of detecting Lawsonia in feces showed too high non-specific response. In addition, nevertheless the FOB test result showed that blood evident could be founded in pig feces, the diagnosing result was not fit to PCR test result, which shows blood in pig feces could be from not only hemorrhagic PPE but also many reasons. Conclusions: To deal with the PPE effectively, it will be better for farmers to screen the PPE in earlier stage with easy and rapid diagnosing tool on farm. This study found out that the rapid kit could detect the Lawsonia intracellularis and hemoglobin in pig feces. However, the non-specific response to negative samples of PPE was too high to use at a pig farm. Further research is needed for lowering the non-specific response with the rapid kit.