• Title/Summary/Keyword: KEPCO System

Search Result 1,667, Processing Time 0.03 seconds

Comparison of Reduction Reactivity of New Oxygen Carriers for Chemical Looping Combustion System in a Bubbling Fluidized Bed (기포유동층에서 케미컬루핑 연소시스템을 위한 신규 산소전달입자들의 환원반응성 비교)

  • KIM, HANA;LEE, DOYEON;BAE, DAL-HEE;SHUN, DOWON;BAEK, JEOM-IN;RYU, HO-JUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.5
    • /
    • pp.554-560
    • /
    • 2017
  • Reduction reactivity of new oxygen carriers for chemical looping combustion system were investigated using $CH_4$ as a reduction gas in a bubbling fluidized bed reactor and compared with that of former SDN70 oxygen carrier. New oxygen carriers showed good reduction reactivity at different $CH_4$ concentration. N018-R2 particle represented better reactivity than SDN70 at high $CH_4$ concentration. N018-R2 particle showed higher fuel conversion and $CO_2$ selectivity than those of SDN70 particle within the temperature range of $750-900^{\circ}C$. Moreover, attrition loss of N018-R2 particle was almost same with that of SDN70 particle. Consequently, we could select N018-R2 particle as the best oxygen carrier.

A Study on the Development of Prediction System for Pipe Wall Thinning Caused by Liquid Droplet Impingement Erosion (액적충돌침식으로 인한 배관감육 예측체계 구축에 관한 연구)

  • Kim, Kyung-Hoon;Cho, Yun-Su;Hwang, Kyeong-Mo
    • Corrosion Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.125-131
    • /
    • 2013
  • The most common pipe wall thinning degradation mechanisms that can occur in the steam and feedwater systems are FAC (Flow Acceleration Corrosion), cavitation, flashing, and LDIE (Liquid Droplet Impingement Erosion). Among those degradation mechanisms, FAC has been investigated by many laboratories and industries. Cavitation and flashing are also protected on the piping design phase. LDIE has mainly investigated in aviation industry and turbine blade manufactures. On the other hand, LDIE has been little studied in NPP (Nuclear Power Plant) industry. This paper presents the development of prediction system for pipe wall thinning caused by LDIE in terms of erosion rate based on air-water ratio and material. Experiment is conducted in 3 cases of air-water ratio 0.79, 1.00, and 1.72 using the three types of the materials of A106B, SS400, and A6061. The main control parameter is the air-water ratio which is defined as the volumetric ratio of water to air (0.79, 1.00, 1.72). The experiments were performed for 15 days, and the surface morphology and hardness of the materials were examined for every 5 days. Since the spraying velocity (v) of liquid droplets and their contact area ($A_c$) on specimens are changed according to the air-water ratio, we analyzed the behavior of LDIE for the materials. Finally, the prediction equations(i.e. erosion rate) for LDIE of the materials were determined in the range of the air-water ratio from 0 to 2%.

Reaction Characteristics of New Oxygen Carrier for 0.5 MWth Chemical Looping Combustion System at High Temperature and High Pressure Conditions (0.5 MWth 케미컬루핑 연소 시스템 적용을 위한 신규 산소전달입자의 고온·고압 반응 특성)

  • KIM, JUNGHWAN;LEE, DOYEON;NAM, HYUNGSEOK;JO, SUNG-HO;HWANG, BYUNG WOOK;BAEK, JEOM-IN;RYU, HO-JUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.5
    • /
    • pp.473-482
    • /
    • 2018
  • To check applicability of recently developed new oxygen carrier for 0.5 MWth chemical looping combustion system, reactivity tests were carried out at high temperature and high pressure conditions. Pressure, temperature, gas velocity, $CH_4$ flow rate, and solid height were considered as operating variables. The new oxygen carrier (N016-R4) showed not only high fuel conversion but also high $CO_2$ selectivity within all the operating conditions in this study. The reactivity of N016-R4 particle was compared with previous oxygen carriers. The N016-R4 particle represented outstanding reactivity among 10 oxygen carriers in terms of fuel conversion and $CO_2$ selectivity.

ADVANCED MMIS TOWARD SUBSTANTIAL REDUCTION IN HUMAN ERRORS IN NPPS

  • Seong, Poong Hyun;Kang, Hyun Gook;Na, Man Gyun;Kim, Jong Hyun;Heo, Gyunyoung;Jung, Yoensub
    • Nuclear Engineering and Technology
    • /
    • v.45 no.2
    • /
    • pp.125-140
    • /
    • 2013
  • This paper aims to give an overview of the methods to inherently prevent human errors and to effectively mitigate the consequences of such errors by securing defense-in-depth during plant management through the advanced man-machine interface system (MMIS). It is needless to stress the significance of human error reduction during an accident in nuclear power plants (NPPs). Unexpected shutdowns caused by human errors not only threaten nuclear safety but also make public acceptance of nuclear power extremely lower. We have to recognize there must be the possibility of human errors occurring since humans are not essentially perfect particularly under stressful conditions. However, we have the opportunity to improve such a situation through advanced information and communication technologies on the basis of lessons learned from our experiences. As important lessons, authors explained key issues associated with automation, man-machine interface, operator support systems, and procedures. Upon this investigation, we outlined the concept and technical factors to develop advanced automation, operation and maintenance support systems, and computer-based procedures using wired/wireless technology. It should be noted that the ultimate responsibility of nuclear safety obviously belongs to humans not to machines. Therefore, safety culture including education and training, which is a kind of organizational factor, should be emphasized as well. In regard to safety culture for human error reduction, several issues that we are facing these days were described. We expect the ideas of the advanced MMIS proposed in this paper to lead in the future direction of related researches and finally supplement the safety of NPPs.

Safety-Related Bus Voltage Variation during Large Induction Motor Start-up in 1400MW Light Water Reactor Type Nuclear Power Plant (1400MW급 경수로형 원자력발전소의 대용량 유도전동기 시동시 안전관련 모선 전압 변동)

  • Lee, Cheoung Joon;Kim, Chang Kook;Noh, Young Seok;Joo, Young Hwan
    • Plant Journal
    • /
    • v.12 no.4
    • /
    • pp.37-43
    • /
    • 2016
  • Power system which provides electricity to the accident mitigation load for nuclear power plant should be verified to maintain the proper voltage level under the various loading and source conditions. For this purpose, it was needed to collect the voltage data of safety related buses during operation of the Reactor Coolant Pump(RCP) motor and Component Cooling Water Pump(CCWP) motor, respectively, under the certain loading condition of the plant. The data (such as, voltage, current, power factor) collected from actual measurement were used to modify the existing ETAP model and then the reanalysis was conducted to simulate the testing conditions. Through these actual measurement and analysis, it ensures that the existing electrical system analysis including assumptions and methods was conducted properly. Finally, the voltage of safety related buses was not dropped below the acceptable level, and the discrepancy between two results was within the limit.

  • PDF

A Study on Reinforcement Planning of Transmission Lines for Composite Power System (복합계통의 송전설비 보강계획에 관한 연구)

  • 차준민
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.45-50
    • /
    • 2001
  • Fuzzy theory is used to quantify some subjective criteria and consider uncertain factors for transmission line reinforcement planning in this paper. Sugeno's fuzzy integral is also used in the proposed method, because it can be easily allied to multi attribute decision making problems such as power system planning. To verify the proposed algorithm, some bode-neck lines are searched for the case that the amount of Maximal Load Supplying Capability(MLSC) is small using the results of contingency analysis for Korea Electric Power Corporation(KEPCO)'s 345[kV] transmission line in 1998. And several feasible alternatives are composed for line reinforcement which can dissolve the bottle-neck.

  • PDF

Development of the Corrosion Deterioration Inspection Tool for Transmission Tower Members (송전철탑 부재 부식열화 검사장비 개발)

  • Woo, Sang-Kyun;Youn, Byong-Don;Kim, Ki-Jung;Chu, In-Yeop
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.77-83
    • /
    • 2016
  • Recently, interests for maintenance of transmission tower are increasing to extend life of structures and reduce maintenance cost. However, existing classical diagnosis method of corrosion deteriorated degree on the transmission tower steel members, visual inspection, has a problem that error often due to difference of inspector's individual knowledge and experience. In order to solve the problem, this study carried out to develop the corrosion deterioration inspection tool for transmission tower steel members. This tool is composed of camera equipment and computer-aided diagnosis system. We standardized the photographing method by camera equipment to obtain suitable pictures for image processing. Diagnosis system was designed to evaluate automatically degree of corrosion deterioration for member of transmission tower on the basis of the RGB color image processing techniques. It is anticipated that developed the corrosion deterioration inspection tool will be very helpful in decision of optimal maintenance time for transmission tower corrosion.

Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Power Supply Regulation (부하변동에 의한 지중유효열전도도와 보어홀 전열저항 해석)

  • Ro, Jeong-Geun;Yon, Kwang-Seok;Song, Heon
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.80-86
    • /
    • 2011
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. Another important factor is the borehole thermal resistance($R_b$). Thermal response tests offer a good method to determine the ground thermal properties for the total heat transport in the ground. This is done by supplying a constant heat power into a borehole heat exchanger. There are two methods to supply a constant heat power. One is to employ the electricity provided by Korea Electric Power Corporation(KEPCO). The other is to use electricity generated by a generator. In this study, the power supply regulation was found to reduce when the electricity generated by the generator was used. This is because the generator evaluated with the power supply characteristically reduces the power supply regulation between an overload and a complex using. But it sometimes occurs a power supply regulation in In-situ thermal response test. In this case getting of k,$R_b$ requires delay times and restored normal state. However, the effect of the delay times and restored normal state on the soil thermal conductivity and borehole thermal resistance is very small. Therefore it is possible to use a generally accepted delay times and restored normal state in the analysis. In this work, it is also shown that an acceptable range of ${\Delta}k$, ${\Delta}R_b$ for normal state and regulation state might be approximately 0.01-0.16W/m k, and -0.004-0.007m K/W, respectively. Thus, restored normal state of power supply regulation is valuable to recommend.

MEASUREMENT OF NUCLEAR FUEL ROD DEFORMATION USING AN IMAGE PROCESSING TECHNIQUE

  • Cho, Jai-Wan;Choi, Young-Soo;Jeong, Kyung-Min;Shin, Jung-Cheol
    • Nuclear Engineering and Technology
    • /
    • v.43 no.2
    • /
    • pp.133-140
    • /
    • 2011
  • In this paper, a deformation measurement technology for nuclear fuel rods is proposed. The deformation measurement system includes a high-definition CMOS image sensor, a lens, a semiconductor laser line beam marker, and optical and mechanical accessories. The basic idea of the proposed deformation measurement system is to illuminate the outer surface of a fuel rod with a collimated laser line beam at an angle of 45 degrees or higher. For this method, it is assumed that a nuclear fuel rod and the optical axis of the image sensor for observing the rod are vertically composed. The relative motion of the fuel rod in the horizontal direction causes the illuminated laser line beam to move vertically along the surface of the fuel rod. The resulting change of the laser line beam position on the surface of the fuel rod is imaged as a parabolic beam in the high-definition CMOS image sensor. An ellipse model is then extracted from the parabolic beam pattern. The center coordinates of the ellipse model are taken as the feature of the deformed fuel rod. The vertical offset of the feature point of the nuclear fuel rod is derived based on the displacement of the offset in the horizontal direction. Based on the experimental results for a nuclear fuel rod sample with a formation of surface crud, an inspection resolution of 50 ${\mu}m$ is achieved using the proposed method. In terms of the degree of precision, this inspection resolution is an improvement of more than 300% from a 150 ${\mu}m$ resolution, which is the conventional measurement criteria required for the deformation of neutron irradiated fuel rods.

A Study on the Effect of Members' Perception of Internal Performance Evaluation on Organizational Commitment: Focused on the Case of A Public Corporation (내부성과평가에 대한 구성원 인식이 조직몰입에 미치는 영향 연구 : A 공기업사례를 중심으로)

  • Shin, Soohaeng;Woo, Yoonseuk
    • Knowledge Management Research
    • /
    • v.22 no.3
    • /
    • pp.1-16
    • /
    • 2021
  • For the effective responsiveness toward Management Evaluation System of Public Institutions and continuous development as a public corporation, internal performance management is essential. In this study, the effect of employees' perceptions on the effectiveness and acceptability of the internal performance evaluation system on organizational commitment was tested, and we attempted to find implications for efficient performance management. For this purpose, we obtained valid responses from 208 members of A corporation and the hypotheses were verified through multiple regression analysis. As a result of the analysis, 'performance evaluation effectiveness' and 'performance evaluation acceptability' for internal performance evaluation had positive effects on 'organizational commitment'; however, the effect of 'differential performance compensation' on 'organizational commitment' was not significant. Also, among the control variables, 'age' and 'job group' were found to have a negative (-) effect on 'organizational commitment'. To derive more generalized conclusion, other researches using bigger samples are needed.