• Title/Summary/Keyword: KEPCO System

Search Result 1,667, Processing Time 0.043 seconds

Dynamic Characteristics of Digital Distance Relay Scheme Using Real Time Digital Simulator(RTDS) (RTDS를 이용한 Digital 거리계전기의 동특성 시험에 관한 연구)

  • Jung, Chang-Ho;Kim, Il-Dong;Kim, Yeong-Han;Kim, Sok-Il
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.109-111
    • /
    • 1996
  • This paper describes real time dynamic tests on the digital distance relay using new digital test system including RTDS(Real Time Digital Simulator) in KEPRI. The RTDS is developed by the Manitoba HVDC Reserch Centre and consists of specialized hardware and software which allows transients simulation of electrical power systems in real time. From high impedance fault test, it is known that the characteritics of distance reach is influenced by load flow. A detailed discussion of relay test using the RTDS simulator, high impedance faults and test results are included in the paper.

  • PDF

A Numerical Modelling of Cogeneration Systems for the Short-Term Operation Strategy (열병합발전시스템의 단기운전계획을 위한 수리적모델 수립에 관한 연구)

  • Lyu, Seung-Heon;Lee, Jong-Bum;Kim, Joon-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.198-201
    • /
    • 1993
  • In this paper a numerical model of the industrial cogeneration system which have a thermal storage tank is proposed for the short-term operation strategy. Short-term operation costs of towing cycle and bottoming cycle are calculated by using the proposed model of a thermal storage tank. Simulation results of four cases are compared and analyzed each other. By these simulations which are similar to real operation circumstances, the validity of the proposed model is verified.

  • PDF

A Method for Transient Stability Assessment using Maximum Generator Angle (발전기 최대 위상각을 이용한 전력계통 과도안정도 평가)

  • Lee, Duck-Jae;Jang, Gil-Soo;Kwon, Sae-Hyuk;Kim, Tae-Kyun;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.239-241
    • /
    • 2003
  • The time domain simulation method of transient stability presents accuracy and reliability, but it demands much computational time. Therefore it is necessary to filter out very stable and very unstable cases from a large set of contingencies. Following a disturbance, the shape and magnitude of representative generator angle which is most increased after fault clearing are the measure of transient stability. This paper propose a method that is not a calculation of the exact CCT of contingency, but a fast assessment of transient stability. Also it can help operators identify transient stability immediately without analyzing the graphical results. The proposed method is applied to the KEPCO system. The PSS/E is used as a time domain simulation engine by IPLAN.

  • PDF

Frequency Dependend Network Equivalents to Electromagnetic Transient Simulation (주파수 의존 등가회로의 전자기 과도 현상 시뮬레이션)

  • Wang, Y.P.;Jo, K.S.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.592-593
    • /
    • 2007
  • The complexity of modern power systems often makes it impractical to model it in its entirety for electromagnetic transient studies. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). The advantage of using z-domain fitting is that it can be directly implemented in a digital simulation program without any loss of accuracy. Fitting in the s-domain always requires "discretizing" a continuous system and the inherent approximations. This paper presents z-domain rational function formulation and demonstrates the use of it for the assessment of the transient response of the Lower South Island of New Zealand.

  • PDF

Risk-Based Allocation of Demand Response Resources Using Conditional Value-at Risk (CVaR) Assessment

  • Kim, Ji-Hui;Lee, Jaehee;Joo, Sung-Kwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.789-795
    • /
    • 2014
  • In a demand response (DR) market run by independent system operators (ISOs), load aggregators are important market participants who aggregate small retail customers through various DR programs. A load aggregator can minimize the allocation cost by efficiently allocating its demand response resources (DRRs) considering retail customers' characteristics. However, the uncertain response behaviors of retail customers can influence the allocation strategy of its DRRs, increasing the economic risk of DRR allocation. This paper presents a risk-based DRR allocation method for the load aggregator that takes into account not only the physical characteristics of retail customers but also the risk due to the associated response uncertainties. In the paper, a conditional value-at-risk (CVaR) is applied to deal with the risk due to response uncertainties. Numerical results are presented to illustrate the effectiveness of the proposed method.

Load Balancing Technique to Release Multiple Overloading of Distribution Feeders using Minimum Spanning Tree (최소신장트리를 이용한 배전선로 다중 과부하 해소 방법)

  • Oh, Seong-Hyeon;Lee, Han-Seong;Kim, Young-Kook;Lim, Seong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.2
    • /
    • pp.33-39
    • /
    • 2015
  • Power supplying capacity of the distribution feeder should be maintained within thermal capacity of the wire. This paper presents the minimum spanning tree based load balancing technique to release multiple overloading of distribution feeders. In order to minimize number of involved backup feeders, Dijkstra and Prim algorithm are adopted to construct minimum spanning tree. Simulation testing result based on part of KEPCO's commercial distribution systems shows effectiveness of proposed scheme.

Performance Evaluation of 154 kV Separable Dry Type Plug-in Connector (154 kV 건식형 지중종단접속함의 성능 평가)

  • Kim, Seok-Sou;Park, Young-Chang;Oh, Chang-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.470-471
    • /
    • 2007
  • Underground connectors in 154kV for the connection between power cables and power equipments represent a greater part of power system stability and reliability. This paper presents the performance evaluation of 154kV separable dry type plug-in connector of a company in Japan for transformers and Gas Insulated Switchgear. And the possibility of the application on domestic underground line was considered.

  • PDF

Characteristics of Joint High Temperature Superconducting tape (High Temperature Superconducting tape(Bi-2223)의 접속시 통전특성)

  • Kim, Hae-Joon;Sim, Ki-Deok;Cho, Jeon-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.244-245
    • /
    • 2007
  • Specially, High Temperature Superconducting power-transmission cable(HTS cable), 3-phase 100m long, 22.9kV class HTS power transmission cable system have been developed by Korea Electrotechnology Research Institute (KERI) and LS cable Ltd. that is one of 21st century frontier project in Korea. This cable was installed in KEPCO(Go-chang) testing site. In case of manufacturing HTS cable, superconducting joint is very important because they need very long tapes. Therefore, this paper gives some investigation of AC Loss in joined HTS tape by using several joint methods. Finally, this paper was shown background data for the form of HTS cable joint.

  • PDF

Characteristics of AC loss after jointing High Temperature Superconducting tape (High Temperature Superconducting tape의 joint 후 AC loss특성)

  • Kim, Hae-Joon;Sim, K.;Cho, J.;Jung, H.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.931-932
    • /
    • 2007
  • Specially, High Temperature Superconducting power-transmission cable(HTS cable), 3-phase 100m long, 22.9kV class HTS power transmission cable system have been developed by Korea Electrotechnology Research Institute (KERI) and LS cable Ltd. that is one of 21st century frontier project in Korea. This cable was installed in KEPCO(Go-chang) testing site. In case of manufacturing HTS cable, superconducting joint is very important because they need very long tapes. Therefore, this paper gives some investigation of AC Loss in joined HTS tape by using several joint methods. Finally, this paper was shown background data for the form of HTS cable joint.

  • PDF

A Review of the Method and System of Real-Time Voltage Stability Risk Index (실시간 전압안정도 위험지수(VSRI) 계산방법과 시스템에 대한 고찰)

  • Kim, D.J.;Moon, Y.H.;Song, C.K.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.443-445
    • /
    • 2007
  • 본 논문은 전력계통의 전압안정도 향상을 위해서 실시간 전압안정도 위험지수(Voltage Stability Risk Index, VSRI)를 계산하는 방법과 시스템을 기술한다. 기존의 모선 전압안정도 감시방법은 조류계산이라는 수학적 모델을 적용한 방법으로 입력데이터의 수가 많고 오차가 항상 존재하기 때문에 계산결과가 부정확하고 계산주기가 십 여분 이상 소요되는 단점을 갖는 반면, 제안된 방법은 측정된 전압 값을 사용하기 때문에 정확하고 실시간으로 모선의 과도 전압안정도를 감시할 수 있다. 특히 제안된 방법은 과도 전압안정도에 취약한 모선을 실시간으로 감시할 수 있다.

  • PDF