Investigation on the necessity and economic of Dynamic reserve reactive power at the KEPCO system (한전 계통에서의 순동 무효전력원 필요성 검토)

  • Kim, Jae-Chul;Cha, Seung-Tae;Yoon, Yong-Beum;Park, Chul-Woo;Kim, Kun-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.215-217
    • /
    • 2002
  • 본 논문에서는 2004, 2007년 한전 계통에 대해 상정사고 시 수도권 지역에서의 순동 무효전력원 필요성, 확보 방안을 제시하였다. 수도권 지역에서 순동 무효전력원의 필요성을 제시하였고, 수도권 지역의 모든 354KV 이상 송전선로 1루트 상정사고 리스트를 작성하여 전압 안정도 측면에서 문제가 발생하는 상정사고를 선정하였다. 선정된 상정사고에 PSS/E를 사용한 QV곡선을 이용하여 순동 무효전력 확보방안을 제시하였다.

  • PDF

A Study on the State Estimation of a Substation (변전소 상태변수 추정에 관한 연구)

  • Lee, H.J.;Kim, Y.H.;Park, S.M.;Kang, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.270-272
    • /
    • 1999
  • As the power system automation, especially the substation automation is currently a major issue, it has been widely studied. Since a measured value usually has an error that results in the communication process and the characteristics of a measurement device mainly depending on the reliability. The accuracy and reliability of measured values at a substation is an important factor for substation automation. In this paper, a state estimation algorithm is proposed for domestic 154kV/22.9kV distribution substations, and the results showed promising application.

  • PDF

TCSC $H_{\infty}$ Controller Design for Damping Interarea Oscillations (TCSC의 $H_{\infty}$ 제어기를 이용한 대규모 전력계통의 지역간 진동모드 제동)

  • Kim, Yong-Gu;Nam, Hae-Kon;Jeon, Young-Hwan;Shim, Kwan-Shik;Song, Sung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.157-159
    • /
    • 1999
  • This paper presented design of an $H_{\infty}$ controller for TCSC to enhance the damping of an inter-area oscillation in KEPCO power system. TCSC location is selected by using eigne sensitivity and frequency response. Nonliner time simulation and eigenvalue analysis show that the proposed TCSC $H_{\infty}$ controller can suppress the inter-area oscillations efficiently with induced reduction model correctly.

  • PDF

Applications of Eigen-Sensitivity for Contingency Screening of Transient Stability in Large Scale Power Systems (대규모 전력계통의 과도안정도 상정사고 선택에 고유치감도 응용)

  • Shim, Kwan-Shik;Nam, Hae-Kon;Kim, Yong-Ku;Song, Sung-Geun
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.193-196
    • /
    • 1999
  • This paper presents a new systematic contingency selection and screening method for transient stability. The variation of modal synchronizing torque coefficient(MSTC) is computed using eigen-sensitivity analysis of the electromechanical oscillation modes in small signal stability model and contingencies are ranked in decreasing order of the sensitivities of the MSTC(SMSTC). The relevant clusters are identified using the eigenvector or participating factor. The proposed algorithm is tested on the KEPCO system. Ranking obtained by the SMSTC is consistent with the time simulation results by PSS/E.

  • PDF

First Installation of High Stress EHV XLPE Cable in korea (초고압 고내력 케이블 국내 최초 현장 적용)

  • Oh, J.O.;Cho, S.H.;Lee, S.K.;Kim, H.J.;Oh, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1057-1059
    • /
    • 1999
  • Recently, increased demand of electrical energy caused additional installation of underground power cable, Industrialization of metro makes civil works difficult. So installed ducts became a key of underground power transmission, LG cable set to work development of high stress cable. LG cable stated in 1996, got a certificate of type test in 1998, and applied at domestic site in Nov. 1999. High stress cable has some merit, decrease of civil cost, reduction of work time, by reason of decrease of dia. and weight, and economical system design, so LG cable has a good merit in comparison with competitive company in domestic and foreign market.

  • PDF

A Study on the prevention of edge effect reducing dielectric strength (절연내력에 미치는 주변효과의 방지에 관한 연구)

  • Kwak, Hee-Ro;Shin, Hee-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.267-271
    • /
    • 1987
  • The test cell for preventing the edge effect reducing the intrinsic breakdown strength of polypropylene film and measuring the intrinsic breakdown strength of the film was developed. The new approach was to develope an electrode system with an edge region which is carefully graded over an extended distance. The new test arrangement employed a central circular electrode at high voltage and a set of nine concentric surrounding rings each controlled in potential by external grading resistors to be at decreasing potentials from that at the center in 10% increments. Two different size structures using the same basic principle were tried and were both found to be successful. The test electrodes were manufactured using standard printed circuit technology and were chosen to be copper on high dielectric constant GIO board.

  • PDF

A study on Fault Diagnosis in Power systems Using Probabilistic Neural Network (확률신경회로망을 이용한 전력계통의 고장진단에 관한 연구)

  • Lee, Hwa-Seok;Kim, Chung-Tek;Mun, Kyeong-Jun;Lee, Kyung-Hong;Park, June-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.2
    • /
    • pp.53-57
    • /
    • 2001
  • This paper presents the new methods of fault diagnosis through multiple alarm processing of protective relays and circuit breakers in power systems using probabilistic neural networks. In this paper, fault section detection neural network (FSDNN) for fault diagnosis is designed using the alarm information of relays or circuit breakers. In contrast to conventional methods, the proposed FSDNN determines the fault section directly and fast. To show the possibility of the proposed method, it is simulated through simulation panel for Sinyangsan substation system in KEPCO (Korea Electric Power Corporation) and the case studies show the effectiveness of the probabilistic neural network mehtod for the fault diagnosis.

  • PDF

The Study of the Automation Systems using Satellite Communications (위성통신을 이용한 자동화 감시 시스템 구축 연구)

  • Kim, Myong-Soo;Hyun, Duck-Hwa;Cho, Seon-Ku;Kim, Choong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2540-2542
    • /
    • 2002
  • In recent years, it is a worldwide trend that many power utilities focus their attention to employ up-to-date communication technology to the automation of their power plants and distribution systems. Automation Systems in Korea was installed using twisted pair cable(TPC), power line carrier(PLC), coaxial cable(CA), wireless network(wireless data, TRS and PCS). Among the communication media only Satellite Communication guarantees the reliable communication in case of emergency such as a flood, a heavy snow and an earthquake. It can integrate two-way satellite systems to existent nationwide SCADA controlling points of electric power transmission & distribution system that enables real time remote monitoring and controlling automatically. This paper presents some of design efforts for the satellite communication network as the media of Automation Systems.

  • PDF

The Development of the Optical Network for the Automation Systems in Electric Power Companies (전력자동화서비스를 위한 광네트워크 설계 및 모뎀개발)

  • Kim, Myong-Soo;Hyun, Duck-Hwa;Cho, Seon-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2543-2545
    • /
    • 2002
  • There are many applicable services such as remote metering, load control, distribution line automation, Pole transformer Monitoring having their own networks in the electric power company. The application of the optical network technology as the back-born network to the Automation Systems in KEPCO is potentially beneficial in reliability, speed, and expandability. The 1-core and 2-core optical modems were developed and used by the Distribution Automation System. But, They had some disadvantages and advantages. So, We designed the new optical modems applied each advantages. This paper presents some of design efforts and test results for the multi-channel optical modem at KRPRI.

  • PDF

Overvoltage Analysis and Air Clearance Design of 345kV/154kV Transmission Tower (345kV/154kV 계통 과전압 해석과 공기절연간격 산정)

  • Shim, E.B.;Woo, J.W.;Kwak, J.S.;Yoon, S.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.449-451
    • /
    • 2001
  • This paper described the switching overvoltage analysis on the 345kV and 154kV transmission system by EMTP(Electromagnetic transient Program) for the enactment of current insulation design standards of KEPCO. The air clearance design of current transmission tower was reviewed and revised by the calculated result, considering swing angle for the each type of insulator string by the wind velocity.

  • PDF