• 제목/요약/키워드: KEPCO Power System

검색결과 1,267건 처리시간 0.025초

케미컬루핑 연소시스템을 위한 산소전달입자의 상온-상압 고체순환특성 (Solid Circulation Characteristics of Oxygen Carrier for Chemical Looping Combustion System at Ambient Temperature and Pressure)

  • 윤주영;김하나;김정환;이도연;백점인;류호정
    • 한국수소및신에너지학회논문집
    • /
    • 제28권4호
    • /
    • pp.384-391
    • /
    • 2017
  • Effects of operating variables on solid circulation rate were measured and discussed using two-interconnected circulating fluidized bed system at ambient temperature and pressure. OCN 706-1100 particles were used as oxygen carrier. The measured solid circulation rates increased as the lower loop seal gas flow rates and the solid height in the fuel reactor increased. Suitable operating conditions to avoid choking of the air reactor were confirmed. Continuous long-term operations of steady-state solid circulation were also demonstrated at two different conditions based on the operating window.

0.5 MWth 급 케미컬루핑 연소시스템에서 대량생산 입자의 고체순환 특성 및 반응 특성 (Solid Circulation and Reaction Characteristics of Mass Produced Particle in a 0.5 MWth Chemical Looping Combustion System)

  • 류호정;조성호;이승용;이도연;남형석;황병욱;김하나;김정환;백점인
    • 한국수소및신에너지학회논문집
    • /
    • 제30권2호
    • /
    • pp.170-177
    • /
    • 2019
  • Continuous solid circulation test at high temperature and high pressure conditions and batch type reduction-oxidation tests were performed to check feasibility of a 0.5 MWth chemical looping combustion system. Pressure drop profiles were maintained stable during continuous solid circulation up to 16 hours. Therefore, we could conclude that the solid circulation between an air reactor and a fuel reactor could be smooth and stable. The measured fuel conversion and $CO_2$ selectivity were high enough even at high capacity and even after cyclic tests. Therefore, we could expect high reactivity of oxygen carrier at real operation condition.

SEWGS 시스템을 위한 WGS 촉매들의 CO 전환 특성 (CO Conversion Characteristics of WGS Catalysts for SEWGS System)

  • 류호정;박지혜;이동호;박재현;배달희
    • 한국수소및신에너지학회논문집
    • /
    • 제26권2호
    • /
    • pp.96-104
    • /
    • 2015
  • Reactivity of commercial WGS catalyst and four new catalysts(RMC-3, PC-73, PC-67SU, PC-59) manufactured with various compositions by Korea Electric Power Research Institute(KEPCO RI) were compared to select suitable WGS catalyst for SEWGS system. Steam/CO ratio, gas velocity, flow rates of syngas, and temperature were considered as operating variables. As a result, commercial catalyst showed the highest CO conversion and RMC-3 catalyst showed also high CO conversion. Therefore, commercial and RMC-3 catalysts were selected as applicable catalysts. However, PC-73 catalyst showed low CO conversion at low temperature($200^{\circ}C$) but showed good reactivity at high temperature($225{\sim}250^{\circ}C$), and therefore, PC-73 catalyst was selected as applicable catalyst for high temperature operation. Continuous operations up to 24 hours for those three catalysts(commercial, RMC-3, PC-73) were conducted to check reactivity decay of catalysts. All three catalysts maintained their original reactivity.

0.5 MWth 급 케미컬루핑 연소시스템에서 대량생산 산소전달입자의 환원반응 특성에 미치는 온도, 압력, 유속 및 용량의 영향 (Effects of Temperature, Pressure, Gas Velocity, and Capacity on Reduction Characteristics of Mass Produced Particle in a 0.5 MWth Chemical Looping Combustion System)

  • 류호정;이도연;남형석;황병욱;김하나;원유섭;백점인
    • 한국수소및신에너지학회논문집
    • /
    • 제32권1호
    • /
    • pp.53-62
    • /
    • 2021
  • Batch type reduction-oxidation tests were performed to check effects of temperature, pressure, gas velocity, and capacity on reduction characteristics of mass produced particle in a 0.5 MWth chemical looping combustion system. The fuel conversion and the CO2 selectivity increased as the temperature increased and as the gas velocity decreased. However the CO2 selectivity showed the maximum and decreased as the capacity increased because the CO emission increased. The results show that high temperature, low gas velocity and low inert gas concentration are preferable to ensure high reactivity of oxygen carrier in the fuel reactor.

재생에너지 발전량 예측제도 기반 집합전력자원 구성모델 개발 (The Development of an Aggregate Power Resource Configuration Model Based on the Renewable Energy Generation Forecasting System)

  • 강은경;장하렴;양선욱;양성병
    • 지능정보연구
    • /
    • 제29권4호
    • /
    • pp.229-256
    • /
    • 2023
  • 팬데믹으로 인한 재택근무와 가정용 전력수요의 증가는 전력수요 패턴에 상당한 변화를 불러왔다. 이로 인해 한전 PPA(전력구매계약) 및 자가용 태양광 발전량 파악이 어려워지고, 전력거래소의 전력수요예측과 계통운영에 어려움이 가중되고 있다. 전기에너지는 다른 에너지 자원과 달리 저장이 어려워, 생산된 에너지와 소비 사이의 균형을 유지하는 것이 매우 중요하다. 전기에너지의 부족이나 과잉 생산은 에너지 시스템에 큰 불안정성을 초래할 수 있으므로, 전력 수급을 효과적으로 관리하는 것이 필수적이다. 특히, 4차 산업혁명 시대에는 데이터의 중요성이 더욱 커져 대규모 화재나 정전과 같은 문제가 심각한 영향을 미칠 수 있다. 이에 따라, 전기에너지 분야에서 정확한 전력수요와 함께 재생에너지와 같은 발전량을 정확하게 예측하여 적절한 발전 관리를 하는 것이 중요하며, 이는 불필요한 전력 생산을 줄이고 에너지 자원을 효율적으로 활용하는데 도움이 된다. 이에, 본 연구에서는 산업통상자원부에서 제공한 169개 발전소의 데이터를 활용하여 최적의 집합전력자원을 구성하기 위해 (1) 재생에너지 발전량 예측제도와 목표, 그리고 실제 적용에 대해 검토하고, (2) 예측제도 정산을 고려한 집합구성 알고리즘을 개발한 후, (3) 분석 로직에 이를 적용하여 결과를 종합하고 해석하였다. 본 연구는 최적의 집합구성 알고리즘을 개발하여, 최대 정산금 대비 80.66%에 달하는 집합구성(Result_Number 546)을 도출하였으며, 발전소 집합을 구성하였을 때 정산금을 증가시키는 발전소(B1783, B1729, N6002, S5044, B1782, N6006)와 정산금을 감소시키는 발전소(S5034, S5023, S5031)를 확인하였다. 집합전력자원을 연구단위로 설정하여 최적의 집합구성 알고리즘을 개발한 최초의 연구로서 의의가 있으며, 본 연구결과의 활용으로 전력시스템의 안정성을 향상시키고 에너지 자원이 효율적으로 활용될 수 있기를 기대한다.

열화상 이미지 분석을 통한 배전 설비 공정능력지수 감지 시스템 개발 (Identifying Process Capability Index for Electricity Distribution System through Thermal Image Analysis)

  • 이형근;홍용민;강성우
    • 품질경영학회지
    • /
    • 제49권3호
    • /
    • pp.327-340
    • /
    • 2021
  • Purpose: The purpose of this study is to propose a system predicting whether an electricity distribution system is abnormal by analyzing the temperature of the deteriorated system. Traditional electricity distribution system abnormality diagnosis was mainly limited to post-inspection. This research presents a remote monitoring system for detecting thermal images of the deteriorated electricity distribution system efficiently hereby providing safe and efficient abnormal diagnosis to electricians. Methods: In this study, an object detection algorithm (YOLOv5) is performed using 16,866 thermal images of electricity distribution systems provided by KEPCO(Korea Electric Power Corporation). Abnormality/Normality of the extracted system images from the algorithm are classified via the limit temperature. Each classification model, Random Forest, Support Vector Machine, XGBOOST is performed to explore 463,053 temperature datasets. The process capability index is employed to indicate the quality of the electricity distribution system. Results: This research performs case study with transformers representing the electricity distribution systems. The case study shows the following states: accuracy 100%, precision 100%, recall 100%, F1-score 100%. Also the case study shows the process capability index of the transformers with the following states: steady state 99.47%, caution state 0.16%, and risk state 0.37%. Conclusion: The sum of caution and risk state is 0.53%, which is higher than the actual failure rate. Also most transformer abnormalities can be detected through this monitoring system.

HVDC 슬립 온형 기중 종단접속함에 대한 열 영향 반영 DC 전계 특성 평가 (DC Electric Field Characteristics considering Thermal Effect for HVDC Slip-on Type Outdoor Termination)

  • 권익수;황재상;구재홍;사카모토 쿠니아키;이방욱
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.39-46
    • /
    • 2015
  • 기중종단 접속함은 지중케이블과 가공송전선을 연결하기 위한 접속함으로써 옥외 변전소 등의 대기 중에 설치된다. 이는 21세기 핵심기술로 여겨지고 있는 대륙 간, 국가 간, 육지-섬을 잇는 HVDC 송전선로의 DC 그리드 송전망 형성을 위해 반드시 개발되어야 하는 전력기기이다. 그러나 AC용 접속함의 개발 사례는 다수 존재하는 반면, DC용 접속함의 개발 사례 및 기술은 일본과 중국 등에 일부 존재할 뿐 국내 기술은 부족한 실정이다. 따라서 본 논문에서는 기존 AC용 슬립 온형 기중 종단접속함을 초기모델로 선정하여 HVDC 전력기기로의 적용 가능성을 평가하였다. 먼저 실제 운전 시 기중종단 접속함 내 도체에서 발생하는 열에 의한 내 외부의 온도편차를 고려한 DC 전계해석을 수행하였으며, AC 전계분포 및 열 해석이 반영되지 않은 DC 전계분포와 비교하였다. 또한 DC 전계는 정상상태 뿐만 아니라 과도 구간도 포함하기 때문에 이를 고려한 전계해석을 수행할 필요가 있기 때문에 정상상태와 더불어 극성반전 후 전계분포 역시 비교, 분석하였다. 마지막으로, 기존 AC용 슬립 온형 기중 종단접속함 초기모델을 DC에 적용하기 위해 다양한 형상 변환을 통한 요소 설계를 수행하였다. 기중종단 접속함 구조 내 전계가 가장 집중될 것으로 사료되는 부분을 선정하여 그 지점들의 최대 전계강도 $E_{n.max}$$E_{t.max}$를 측정하였다. 해석 결과, 정상상태시 개선모델의 삼중점 최대 전계강도는 기준모델 대비 2.01% 개선되었으며, 연면 최대 전계강도는 기준모델 대비 36.68% 개선되었다. AC 전계해석 결과인 연면 전계강도 1.11 kV/mm보다는 33.3% 감소하였지만 삼중점 최대 전계강도 8.23 kV/mm보다는 아직 43.6% 크다는 점에서 부분적인 형상 변환이 아닌 DC 환경에 적합한 전혀 다른 근본적인 설계 개념의 변화가 반드시 필요할 것으로 사료된다.

전기차 충전인프라 및 데이터 연계 분석에 의한 시스템 모델링 및 실증 설계 (Novel System Modeling and Design by using Eclectic Vehicle Charging Infrastructure based on Data-centric Analysis)

  • 김항섭;박호민;정태경;이웅재
    • 인터넷정보학회논문지
    • /
    • 제20권2호
    • /
    • pp.51-59
    • /
    • 2019
  • 본 논문은 최근 각광받고 있는 전기차위주의 많은 실증 사업 중 충전 인프라와 연계된 충전운영시스템 및 전기요금간의 관계를 데이터 연계 분석하였다. 현 시점에서 앞으로 일어날 전기차 충전 인프라에 대한 급속한 수요의 증가로 말미암아 수요치를 예측한다는 의미에서 다가오는 시대를 미리 준비 할 수 있다. 동시에 시스템 모델링을 사이트를 중심으로 실증하고 도식화하는 일이 선행되어야 할 요소이다. 기존의 소규모 시뮬레이션에 의한 모델링과 운영시스템의 설계는 데이터 연계분석을 기반으로 하였다. 본 논문에서는 최종적으로 새로운 시스템 모델링을 구현하여 실제 차량과 이용자를 대상으로 각 지점과 노드별로 시간에 따른 시분할 데이터로 분석하고자 표준 형식으로 도입하였다. 실제 구현된 전기차 충전 인프라와 운영시스템을 대상으로 데이터 연계분석 중심의 효율성을 증명하고자 하였다.

원전 연료집합체의 손상, 변형 및 이물질 검사시스템 개발에 관한 연구 (A study on development of screen inspection system to detect damages, bowing, and foreign materials of nuclear fuel assembly for reactor in nuclear power plants)

  • 박기태;노태정
    • 한국산학기술학회논문지
    • /
    • 제14권8호
    • /
    • pp.3617-3624
    • /
    • 2013
  • 원전 연료집합체의 연료봉 내에 잔존하여 연료봉의 손상을 발생시킬 수 있는 이물질의 잔존 여부 및 연료봉의 손상, 연료봉의 휨, 뒤틀림, 그리드 손상여부를 비젼기술과 레이저 스캔 기술을 응용한 원전 연료집합체 스크린 검사 방법을 개발하여 계획예방 정비 기간 중 검사가 가능하도록 연료집합체 검사의 신뢰성과 생산성을 확보하였다. 또한 검사 데이터를 집계, 분석하여, 연료집합체의 변형 상태를 지속적으로 감시함으로써, 국내 각 원자로별 노심 내 연료변형 패턴을 이해할 수 있다. 이는 연료 재장전 도중 발생 가능한 그리드 손상을 방지하는데 기술정보로 활용되어 국내외 원전 안전 운영의 중요한 데이터베이스를 제공하게 된다.

psXML: 서비스 중심적 개방형 아키텍처를 가지는 수용가포털을 위한 XML 기반의 표준화 (psXML: A New XML-based Standard Protocol for Service-oriented, Open Architecture of Consumer Portal)

  • 홍준희;최중인;김진호;김창섭;손성용;최준영
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.108-117
    • /
    • 2007
  • 고전력수용가포털(Consumer Portal)은 소비자의 다양한 장치들과 광역 네트워크, 그리고 에너지서비스사업자(ESP: 한전 등)의 서비스 애플리케이션 플랫폼을 연결하는 물리적 링크이자 논리적 결합으로, 전력서비스 체계에서 소비자-공급자 간 정보교환과 서비스 거래를 담당하는 양방향 통신의 핵심 인프라로서 포털이다. 전력수용가포털(Consumer Portal)의 성공적인 설계와 개발을 위해서는 효율성, 경제성, 확장성을 고려한 서비스 중심적 표준화 전략이 중요하게 고려되어야 한다. 본 논문에서는 전력수용가포털 설계에 필요한 XML기반의 표준화 안을 psXML(Power System XML)로 제안하고 이를 설계, 구현하여 실제 구축 중인 시스템에 적용하였다. 이는 네트워크 및 프로세서 부담을 최소화할 수 있는 수용가포털을 위한 개방형 표준을 구현한 것이다.