한국 원자력 연구소 부설 원자력병원에 설치된 AVF 싸이클로트론을 이용하여 요즈음 핵의학에 널리 사용되는 PET 용 싸이클로트론의 에너지를 검정 할 수 있고 양성자 과잉 핵종인 싸이클로트론 동위원소의 생산 수율에 중요한 변수인 양성자에너지를 탄소에 입사시켜 입사빔의 Range와 에너지를 측정하는 방법을 제시하였다. 본 실험에서 사용된 양성자 빔의 양성자 에너지는 35 MeV와 50 MeV 사이였으며, 탄소 막은 두께 6.3mm, 밀도 $1.712 g/cm^3$를 사용하였다. 탄소 표적물을 $0.9^{\circ}$씩 스텝 모터를 사용하여 회전시킴으로 두께를 변화 시켜 공칭 에너지에 대한 Range를 측정함으로써 입사된 양성자의 에너지를 구하였고 이를 인출반경과 RF주파수를 바탕으로 상대론 적으로 계산된 에너지와 비교하였다.
Kim, Byung-Mun;Kim, Young-Sear;Bak, Joo-Shik;Lee, Jong-Du;Yoo, Seong-Yul;Koh, Kyung-Hwan
Journal of Radiation Protection and Research
/
v.15
no.2
/
pp.113-122
/
1990
After four years of planning, equipment acquisition, facility construction and beam testing, the KCCH cyclotron facility was put into operation in November1986. Now the KCCH cyclotron(MC-50) has been used for four years in neutron therapy and radioisotope production. Up to December 1989, 179(1852 sessions) patient have undergone neutron therapy. Radioisotope production for nuclear medicine use was started from March 1989 after extensive work to overcome target transport, target melting, beam diagnostic and chemical processing problems. This status report introduces the cyclotron facility, and the experiences of neutron therapy and isotope production with the MC-50 cyclotron. Besides, the operation results and the general troubles of the MC-50 during 1989 are summarized. Total operation time was 1252.5 hours. Four hundred hours were used for neutron therapy of 599 treatment sessions and 832.5 hours for radioisotope production. Total amount of produced raioisotope was 1695 mCi(Ga-67 : 1478mCi, Tl-201 : 107 mCi, I-123 : 25mCi, In-111 : 85mCi). Twenty hours were used for scheduled beam testing. In 1989, 882% of the planned operation were performed on schedule and this rats is improved remarkably compared to 71.0% in 1988.
Objectives: Recently, $[methyl-^{11}C]-({\beta}$-Hydroxyethyl)trimethylammonium ($[^{11}C]$choline) Has been discovered to be a very effective tracer in imaging various human tumors using positron omission tomography. Because of the short half-life of C-11, it is very difficult to use in a routine imaging procedure and needs a frequent synthesis of $[^{11}C]$choline. This can be supplemented by the substitution of $[^{11}C]$choline with $[methyl-^{18}F]$fluorocholine. Here, we would like to report ceil uptake and biodistribution of $[^{11}C]$choline and $[^{18}F]$fluorocholine as a basic study. Methods: $[^{11}C]$Choline was prepared by the treatment of $[^{11}C]CH_3I$ with N,N-dimethylaminoethanol and $[^{18}F]$fluorocholine was synthesized from reaction of $CH_2Br[^{18}F]F$ with N,N-dimethylaminoethanol. The radiochemical purity was checked by high performance liquid chromatography (HPLC). The blodistribution of $[^{11}C]$choline and $[^{18}F]$fluorocholine was determined in balb/c mouse at 5 min, 20 min, 40 min and 80 min. The cell uptake was measured using glioma (9L) and colon adenocarcinoma (SW620). Results: The radiochemical purity was more than 98% after purification. In the liver, uptake did not change over time; the uptake was 20%ID/g for $[^{11}C]$choline and 13%ID/g for $[^{18}F]$fluorocholine. In the kidney, radioactivity decreased over time; the uptake was 15%ID/g for $[^{11}C]$choline and 20%ID/g for $[^{18}F]$fluorocholine, 80 min post-injection. The cell uptake of $[^{11}C]$choline was 4.93% for glioma (9L) and 18.69% for colon adenocarcinoma (SW620). For $[^{18}F]$fluorocholine, 1.77% for glioma (9L) and 2.77% for colon adenocarcinoma (SW620). Conclusion: $[^{11}C]$Choline and $[^{18}F]$fluorocholine showed a different cell uptake tendency, depending on cancer cell line.
Objectives: Due to the heterogeneous receptor distribution and changes of receptor status over time, the biochemical measurement of estrogen receptor status of biopsy specimens is not sufficient to diagnose breast cancer. As a result, I-123 labeled estradiols have been applied for the diagnosis. The purpose of this study was to develop a suitable radioligand for imaging estrogen receptor-positive human breast tumors. Methods: Among the various estradiol derivatives, $17{\alpha}-[^{123}I]$iodovinyl estradiol ($[^{123}I]$IVE) has been prepared from $17{\alpha}$-ethynyl estradiol. Labeling of $E-17{\alpha}-[^{123}I]$iodovinyl estradiol (E-$[^{123}I]$IVE) was carried out using peracetic acid with $[^{123}I]NaI\;and\;Z-[^{123}I]IVE$ labelling was archived using chloamine-T/HCl solution with $[^{123}I]$NaI. Labeling yield was determined by silica thin-layer chromatography (TLC) and radiochemical purity was measured by high performance liquid chromatography (HPLC). The biodistribution of E-$[^{123}I]$IVE was measured in immature female rats at 60 min, 120 min and 300 min after injection. Results: The labeling yield of two isomers was 92% and 94% ($E-[^{123}I]IVE\;and\;Z-[^{123}I]IVE$, respectively). The radiochemical purity was more than 98% after purification. The highest uptake was observed at 120 min in uterus (3.11% ID/g for E-$[^{123}I]$IVE). Conclusion: These results suggest the possibility of using E-$[^{123}I]$IVE as an imaging agent for the evaluation of the evaluation of the presence of estrogen receptor in patients with breast cancer.
Radiation exposure of the personnel in the neutron therapy facility of KCCH cyclotron neutron system is discussed. In neutron therapy room, medical personnel is exposed to photons of the remanent induced radioactivity from the isocentric gantry in which targets and collimators are mounted. The radiation level of the neutron therapy room of KCCH cyclotron was acceptable and it decreased immediately after beam off. Personal exposure measured by individual monitor was far less than permissible level.
In this paper, general features and measured results of vacuum pressure on the vacuum system of 50 MeV proton KCCH-cyclotron which was installed in Korea Cancer Center Hospital are described. The vacuum system comprises five subgroups and the operating sequences are automatically controlled by EPROM-programmable controller. In normal operation, the obtained ultimate pressures of vacuum groups were $5{\times}10^{-6}mbar(I,\;II),\;2{\times}10^{-6}mbar(III),\;1.2{\times}10^{-5}mbar(IV),\;1.5{\times}10^{-6}mbar(V)$, respectively. It was confirmed that these pressures was enough to accelerate the 50 MeV-proton beam.
For evaluation of biological effect of $p^+(50.5MeV)$ Be neutron beam produced by Korea Cancer Center Hospital (KCCH) cyclotron the RBE had been measured in experimental tumor Walker 256 carcinosarcoma as well as normal tissue, mouse intestine and bone marrow, in single and fractionated irradiation. As pilot study, the RBE had been measured for the mouse jejunal crypt cells in single whole body irradiation of which the result was 2.8. The obtained RBE values of TCD 50 of Walker 256 tumor, bone marrow and intestine En single irraiation were 1.9, 1.9 and 1.5 respectively. In fractionated irradiation, the RBE value of tumor Walker 256 was decreased as increasing of fraction number and increased as increaing of fraction size.
The relative biological effectiveness has been measured for the biological characterization of $p^+(50.5\;MeV)$ Be neutron of KCCH-Cyclotron prior to clinical application. Measured RBE of mouse jejunal crypt cell in single whole body irradiation was 2.8. This RBE value is changed differently in different biologic systems such as mouse jejunal crypt cells, intestine and bone marrow in different irradiation method, so that in fractionated irradiation RBE is variable to the different fraction size and total dose, and also variable to the number of fractions.
본 논문에서는 12펄스 위상제어 정류기 및 수동 필터와 능동필터로 구성된 KCCH 싸이클로트론 전자석용 고정밀, 고안정 전류 전원장치를 위한 각 구성 부분의 제어 및 설계 특징은 다음과 같다. 12펄스 싸이리스터 컨버터의 출력전압 제어를 위하여 아날로그 phase-locked oscillator 점호방식과 함께 부하에 비해 빠른 동특성을 가지는 내부 전압제어 루프를 구성하여, 입력전원과 변압기의 불평형에 의해 발생하는 저차고조파를 줄어들게 하였다. LC 수동필터와 MOSFET으로 구성된 능동필터를 직렬로 연결하여 출력전압 리플을 허용치 이하로 낮추었다. 12펄스 컨버터 출력전압 리플의 최대 peak-to-peak값이 0.1% 이하가 되도록 수동필터 값을 설계하였으며 설계과정을 제시하였다. 16bit D/A와 A/D에 의해 디지털로 제어되는 pass bank MOSFET 레귤레이터는 출력리플의 slow drift 제어와 설정치 값의 정확한 제어를 가능하게 한다. 또한 MOSFET는 전압 구동형 소자이며 turn-on 전류 도통 시에 양의 저항계수를 갖기 때문에, 첫째 전류 구동소자에 비해 간단한 구동회로를 가지며, 둘째 소자의 병렬 연결이 용이하다는 이점을 갖는다. 본 논문에서는 전류 전원장치 각 부분의 설계에 대하여 상세한 설계결과를 제시하며, 실험결과를 통하여 제안된 설계방식의 우수한 정적 및 동적 특성을 입증한다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.