• Title/Summary/Keyword: K-joint parameters

Search Result 683, Processing Time 0.031 seconds

Mechanical Properties of Friction Joint of AZ31Mg Alloy (AZ31마그네슘합금의 마찰접합특성)

  • Kong, Y.S.;Chun, B.K.;Kang, D.M.
    • Transactions of Materials Processing
    • /
    • v.19 no.5
    • /
    • pp.277-282
    • /
    • 2010
  • Magnesium alloy has been known as lightweight material in automobile and electronic industry with aluminum alloy, titanium alloy and plastic material. Friction welding is useful to join various metals and nonferrous metals that are difficult to join by such as gas welding, resistance welding and electronic beam welding. In this study, friction joining was performed to investigate mechanical properties of Mg alloy with 20mm diameter solid bar. Also the optimal joining conditions for its application were determined on the basis of tensile test, and hardness survey. The joining parameters were chosen as heating pressure, heating time, upsetting pressure, and upsetting time. Heating and upsetting pressure were executed under the range of 10~40MPa and 20~80MPa, respectively. From the experimental results, optimal joining conditions were determined as follows; rotating speed=2000rpm, heating pressure=35MPa, upsetting pressure=70MPa, heating time=1sec, upsetting time=5sec. Also the hardness of jointed boundary showed as HV50 which was similar to that of base metal at the optimal condition, and it was supposed that zone of HAZ was 8mm. Finally two materials were strongly mixed at interface part to show a well-combined microstructure without particle growth or any defect.

Ultimate Strength Interaction of Steel Tubular T-Joint Subjected to Concurrent Action of Compression and Bending (압축과 휨을 동시에 받는 강관 T조인트 극한강도 상호작용)

  • Kim, Kyung-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.298-303
    • /
    • 2016
  • Owing to the advantages of reduced weight and wind effect, the space-framed towers that consist of vertical and horizontal members of circular hollow tubular sections have been adopted widely for various purposes. It is critical to guarantee the strengths of tubular joints where vertical and horizontal members are connected structurally to make the entire space-framed system behave as a single tower structure. In this study, a strength evaluation was conducted for T-type tubular joints subjected to the concurrent action of compression and bending. Three of the available design codes, i.e., AISC, Eurocode 3, ISO 19902 were investigated and a design equation was suggested for an ultimate strength interaction between the axial force and bending moment based on nonlinear finite element analyses by selecting the slenderness ratios at the joints as major parameters.

Comparative performance of seismically deficient exterior beam-column sub-assemblages of different design evolutions: A closer perspective

  • Kanchana Devi, A.;Ramanjaneyulu, K.
    • Earthquakes and Structures
    • /
    • v.13 no.2
    • /
    • pp.177-191
    • /
    • 2017
  • In the present study, exterior beam column sub-assemblages are designed in accordance with the codal stipulations prevailed at different times prior to the introduction of modern seismic provisions, viz., i) Gravity load designed with straight bar anchorage (SP1), ii) Gravity load designed with compression anchorage (SP1-D), iii) designed for seismic load but not detailed for ductility (SP2), and iv) designed for seismic load and detailed for ductility (SP3). Comparative seismic performance of these exterior beam-column sub-assemblages are evaluated through experimental investigations carried out under repeated reverse cyclic loading. Seismic performance parameters like load-displacement hysteresis behavior, energy dissipation, strength and stiffness degradation, and joint shear deformation of the specimens are evaluated. It is found from the experimental studies that with the evolution of the design methods, from gravity load designed to non-ductile and then to ductile detailed specimens, a marked improvement in damage resilience is observed. The gravity load designed specimens SP1 and SP1-D respectively dissipated only one-tenth and one-sixth of the energy dissipated by SP3. The specimen SP3 showcased tremendous improvement in the energy dissipation capacity of nearly 2.56 times that of SP2. Irrespective of the level of design and detailing, energy dissipation is finally manifested through the damage in the joint region. The present study underlines the seismic deficiency of beam-column sub-assemblages of different design evolutions and highlights the need for their strengthening/retrofit to make them fit for seismic event.

Evaluation of image quality for metal artifact using protocol parameters in the MRI (자기공명영상에서 프로토콜 변화를 이용한 금속인공물의 영상평가)

  • Lee, Su-Hyun;Kim, Do-Gyoung;Kim, Yo-Han;Yeum, Hyei-Jeong;Lee, Heon-Jun;Lim, Ju-Yeon;Choi, Woo-Jeon;Kim, Dong-hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.582-585
    • /
    • 2015
  • In the aging society, TKRA is steadily increased because of joint diseases. Artificial joint used in TKRA generates metal artifacts in the MRI. Metal artifact may affect diagnosis. In study, We are going to minimize the effect of metal artifact to improve the value of diagnosis by changing the sequence and the type of artificial joint(Co-Cr, Ni-Ti). 1.5T AVANTO, plastic containers and each of the artificial joint (Normal, Co-Cr, NiTi) were used. After the artificial joints fixed in a paper cup was inserted in a plastic container of cylindrical, Signal intensity was measured. To obtain strong and uniform signal intensity, the plastic container was filled with water. We changed Sequences(T1 TSE, T2 TSE, PD TSE) and obtained an Axial image. After excepting the maximum and minimum values, We calculated the average of SNR, CNR and PSNR. Consequently, The SNR, CNR value of PD TSE are measured higher than these of T1 TSE, T2 TSE and The PSNR of Co-Cr is higher than this of Ni-Ti. The SNR of Co-Cr is similar to the SNR of normal comparing this of Ni-Ti. As a result, Using sequence of PD Tse and Co-Cr alloy is considered to be useful.

  • PDF

Comparison of Radiologic Parameters between Weight Bearing Affected Single Ankle Anteroposterior View and both Ankle Anteroposterior View in Ankle Osteoarthritis (족관절 관절염이 있는 환자에서 체중 부하상태의 양측 족관절과 환측 족관절 전후면 방사선 사진의 방사선학적 측정치의 비교)

  • Kim, Jung-Rae;Lee, Woo-Chun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.3
    • /
    • pp.159-164
    • /
    • 2011
  • Purpose: This study was performed to analyze the results of radiologic parameters between weight bearing affected single ankle anteroposterior (AP) view and both ankle AP view in ankle osteoarthritis (OA). Materials and Methods: Between January 2009 and August 2010, 41 patients (50 ankles) who visited our institution to treat ankle OA were reviewed retrospectively. In radiographic assessment, weight bearing affected single ankle AP view and both ankle AP view were checked, and measured tibial anterior surface angle (TAS), tibial medial malleolar angle (TMM), talar tilting angle (TT), maximum and minimun joint space width (JSW) of ankle, width between articular surface of medial malleolar and medial articular surface of talus as radiologic parameters. Results: On weight bearing both ankle AP view, TAS was $85.4{\pm}4.1^{\circ}$, TMM was $33.1{\pm}9^{\circ}$, TT was $5.4{\pm}6.1^{\circ}$, maximum JSW was $3.2{\pm}2.7$ mm, minimum JSW was $1.1{\pm}1.3$ mm, width between articular surface of medial malleolar and medial articular surface of talus was $1.8{\pm}1.8$ mm and on weight bearing affected ankle AP view, TAS was $85.3{\pm}3.9^{\circ}$, TMM was $34.3{\pm}10.9^{\circ}$, TT was $5.4{\pm}6.5^{\circ}$, maximum JSW was $3.2{\pm}2.7$ mm, minimum JSW was $1.1{\pm}1.3$ mm, width between articular surface of medial malleolar and medial articular surface of talus was $1.6{\pm}1.7$ mm. Conclusion: There is no statistical significance in radiologic parameters between weight-bearing affected single ankle AP view and both ankle AP view in ankle OA.

Comparison of Seismic Velocity and Rock Mass Rating from in situ Measurement (현장 실험을 통한 암반 탄성파 속도와 암반평가 인자 비교)

  • Lee, Kang Nyeong;Park, Yeon Jun;Kim, Ki Seog
    • Tunnel and Underground Space
    • /
    • v.28 no.3
    • /
    • pp.232-246
    • /
    • 2018
  • In this study, the relationship between in situ seismic wave velocities and RMR (rock mass rating) was investigated in a test bed for the examination of the basis of rock classification (RMR) based on seismic wave velocity. The seismic wave velocity showed a monotonous increase with depth. It was also found that there was no systematic correlation between the seismic wave velocity (Vp) and other parameters (RQD, joint spacing, UCS, rock core Vp, and RMR) collected at the same depth of the same borehole. However, correlative relation was observed among RMR, RQD, and joint spacing. On the other hand, when all the data in the borehole (three holes) are examined without considering the depth, Vp still shows no correlation with RMR parameters (e.g., correlative coefficient for uniaxial compressive strength and joint spacing are 0.039 and 0.091, respectively), but Vp shows weak correlative relation with RMR and RQD (correlative coefficient for RQD and RMR are 0.193 and 0.211, respectively). Thus, it is found that it is difficult to deduce physical properties of rock mass directly from seismic wave velocities, but the seismic wave velocity can be used as a tool to approximate rock mass properties because of weaker correlation between Vp and RMR with RQD. In addition, the velocity value of for soft and moderate rocks suggested by widely used construction standards is slower than that of the observed velocity, implying that the standards need to be examined and revised.

Stiffness Analysis of External Fixation System with System Configuration Parameters (시스템 구성 인자를 고려한 외고정장치 시스템의 강성 해석)

  • Kim Yoon Hyuk;Lee Hyun Keun
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.531-536
    • /
    • 2004
  • In fracture treatment with external fixators, the inter-fragmentary movements at the fracture site affect the fracture healing process, and these movements are highly related to the stiffness of external fixation systems. Therefore, in order to provide the optimal fracture healing at the fracture site, it is essential to understand the relationship between the stiffness and the system configurations in external fixation system. In this study we investigated the influences of system configuration parameters on the stiffness in the finite element analysis of an external fixation system of a long bone. The system alignment, the geometric and the material non-linearity of the pin, the joint stiffness and the callus formation were considered in the finite element model. In the first, the system stiffness of the developed finite element model was compared with the experiment data for model validation. The consideration of the joint stiffness and nonlinearity of the model improved the system stiffness results. The joint stiffness, the non-alignment of the system decreased the system stiffness while the callus formation increased the system stiffness. The present results provided the biomechanical basis of rational guidelines for design improvements of external fixators and pre-op. planning to maximize the system stiffness in fracture surgery.

Initial Stiffness of Beam Column Joints of PCS Structural Systems (PCS 구조 시스템 접합부의 초기 강성에 대한 연구)

  • Park, Soon-Kyu;Kim, Moo-Kyung
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.271-282
    • /
    • 2008
  • Specific joint devices composed of end-plates and through bolts are under development to assemble steel beams to PC columns efficiently by dry construction method for the PCS structural system, of which major structural components are precast concrete columns and steel beams. Seismic performance of the joint devices had been evaluated by experimental tests in the previous studies and it was showed that all the performance requirements regarding to strength deterioration, stiffness degradation and energy dissipation capacity were satisfied to the criteria of ACI requirements, but the initial stiffness was not. In order to find out possible causes of the insufficient rigidity of the joint devices and provide the proper measures to improve the performance of the joint accordingly, numerical analyses were carried out by using ABAQUS. Parameters, such as thickness of neoprene pad, conditions of surface between PC column and end-plate, magnitude of pretension forces of through bolts, stiffness of end-plate were taken into consideration. As the result, it was found that the rigidity of the PCS system was negatively affected by the magnitude of initial gaps between PC columns and end-plates, and insufficient stiffness of neoprene fillers and end plates. In order to improve the initial stiffness performance of the joints, measures such as increase of the magnitude of pretension forces on through bolts and increase of the stiffness of end-plate by reducing the bolt pitch and providing adequate stiffeners are recommended.

Effects of a Thera-Band Exercise Program on Pain, Knee Flexion ROM, and Psychological Parameters Following Total Knee Arthroplasty (슬관절 전치환술 후 세라밴드 운동프로그램이 수술 후 통증, 슬관절 굴곡각도 및 심리적 지수에 미치는 효과)

  • Yun, Ji Yeong;Lee, Jong Kyung
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.6
    • /
    • pp.823-833
    • /
    • 2015
  • Purpose: The purpose of the study was to investigate the effects of the Thera-Band exercise program following total knee arthroplasty. Methods: The research design for this study was a nonequivalent control group non-synchronized design. Participants were 30 patients for the experimental group and 30 patients for the control group. The experimental group participated in the Thera-Band exercise program in addition to conventional CPM (continuous passive motion) exercise. The control group received conventional CPM exercise only. Outcome measures were pain, knee flexion range of motion, CRP, and psychological parameters (self-efficacy and fear of falling). Data were analyzed using ${\chi}^2$-test, Fisher's exact test, t-test, and repeated measure ANOVA with SPSS/PC version 21.0. Results: There were significant improvement in self-efficacy, and decreases in pain, and fear of falling in the experimental group compared to the control group. However, no significant differences were found between the two groups for CRP and knee flexion ROM. Conclusion: The Thera-Band exercise program gave an additional benefit over the conventional CPM exercise for patients following total knee arthroplasty, and is recommended for use as an effective nursing intervention for patients after total knee arthroplasty.

Genetic and Environmental Deterrents to Breeding for Disease Resistance in Dairy Cattle

  • Lin, C.Y.;Aggrey, S.E.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.9
    • /
    • pp.1247-1253
    • /
    • 2003
  • Selection for increased milk production in dairy cows has often resulted in a higher incidence of disease and thus incurred a greater health costs. Considerable interests have been shown in breeding dairy cattle for disease resistance in recent years. This paper discusses the limitations of breeding dairy cattle for genetic resistance in six parts: 1) complexity of disease resistance, 2) difficulty in estimating genetic parameters for planning breeding programs against disease, 3) undesirable relationship between production traits and disease, 4) disease as affected by recessive genes, 5) new mutation of the pathogens, and 6) variable environmental factors. The hidden problems of estimating genetic and phenotypic parameters involving disease incidence were examined in terms of categorical nature, non-independence, heterogeneity of error variance, non-randomness, and automatic relationship between disease and production traits. In light of these limitations, the prospect for increasing genetic resistance by conventional breeding methods would not be so bright as we like. Since the phenomenon of disease is the result of a joint interaction among host genotype, pathogen genotype and environment, it becomes essential to adopt an integrated approach of increasing genetic resistance of the host animals, manipulating the pathogen genotypes, developing effective vaccines and drugs, and improving the environmental conditions. The advances in DNA-based technology show considerable promise in directly manipulating host and pathogen genomes for genetic resistance and producing vaccines and drugs for prevention and medication to promote the wellbeing of the animals.