• Title/Summary/Keyword: K-based Sorbent

Search Result 56, Processing Time 0.022 seconds

Methodology for Quantitative Monitoring of Agricultural Worker Exposure to Pesticides (농작업자에 대한 농약 노출의 정량적 측정 방법)

  • Kim, Eun-Hye;Lee, Hye-Ri;Choi, Hoon;Moon, Joon-Kwan;Hong, Soon-Sung;Jeong, Mi-Hye;Park, Kyung-Hun;Lee, Hyo-Min;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.507-528
    • /
    • 2011
  • Agricultural workers who mix/loads and spray pesticide in fields expose to pesticide through dermal and inhalation routes. In such situation, exposed amount should be measured quantitatively for reasonable risk assessment. Patch, gloves, socks and mask will be good materials for monitoring for dermal exposure while personal air monitor equipped with solid adsorbent and air pump will be a tool for inhalation exposure. For extrapolation of absorbed amount in dermal exposure matrices and of trapped amount in solid sorbent to total deraml or inhalation exposure, Korean standard body surface area and respiration rate were proposed in substitution of EPA data. Important exposure factors such as clothing and skin penetration ratio of dermal and inhalation exposure were suggested based on Spraying time for exposure monitoring must be long enough that the amount of pesticide to get absorbed/trapped in exposure matrices results in reasonable analytical value. In domestic case for the both of speed sprayer and power spray machine, spraying time of 20~40 minutes (0.1~0.2 ha) will be reasonable per single replicate before extrapolating to 4 hours a day with triplicates experiment.

Synthesis of Metal-Organic Framework material Cu-BTC and its application for $CO_2$ adsorption (유기 금속 Framework Cu-BTC의 합성 및 이산화탄소 분리 응용)

  • Peng, Mei-Mei;Hemalatha, Pushparaj;Ganesh, Mani;Venkatachalam, Kandan;Oh, Han-Seok;Jang, Hyun-Tae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.147-150
    • /
    • 2011
  • A copper-based metal organic framework (MOF) named Cu-BTC, also known as HKUST-1, was successfully synthesized by using a solvothermal method. The properties of the Cu-BTC sample were characterized with Powder X-ray diffraction (XRD) for phase structure, Thermogravimetric analysis (TGA) for thermal stability, Scanning electron microscopy (SEM) for crystal structure, and Nitrogen adsorption-desorption for pore textural structure. The analysis results displayed that the Cu-BTC sample exhibited a good crystal structure with uniform size of octahedral particles. The BET data revealed a high surface area of $1457 \;m^2g^{-1}$ and a pore volume of $0.60\; cm^3g^{-1}$. The Cu-BTCs ample was also studied for $CO_2$ adsorption and exhibited a maximum $CO_2$ adsorption capacity of 170 mg/g of the sorbent (3.8 mol/kg) at $25^{\circ}C$.

  • PDF

Ambient adsorption of $CO_2$ using an inorganic sorbent (무기흡착제를 이용한 $CO_2$의 상온흡착)

  • Jo, Young-Min;Lee, Ju-Yeol;Park, Young-Koo;Park, Joon-Seok;Kim, Seung-Ho;Ko, Jae-Churl
    • Journal of the Korean Applied Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.92-97
    • /
    • 2007
  • The present paper deals with gaseous carbon dioxide separation by a commercial adsorbent: X-type zeolite. Experimental work was carried out at an ambient condition focusing on how well meeting to the national guideline. A few types of reactor and material were examined, and practical capability was found in a granular bed type reactor with the flow of 2.5 CMM. An optimum design of reactor and adsorbent could provide the required concentration, less than 2500 ppm, for the continuous operation up to 10 hours. More work including automatic regeneration is now underworking.

Optimization of synthesis conditions and $CO_2$ capture capability of Cu-BTC Metal-Organic Framework (이산화탄소 흡착용 Cu-BTC MOF 합성 최적화)

  • Peng, Mei Mei;Hemalatha, Pushparaj;Ganesh, Mani;Jang, Hyun-Tae
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12a
    • /
    • pp.200-203
    • /
    • 2011
  • A copper-based metal organic framework (MOF) named Cu-BTC, also known as HKUST-1, was synthesized by using a solvothermal method at various synthesis temperature, time and pressure. The obtained samples were characterized with Powder X-ray diffraction (XRD) for phase structure, scanning electron microscopy (SEM) for crystal structure, and nitrogen adsorption-desorption for pore textural structure. The Cu-BTC sample was also studied for $CO_2$ adsorption. The analysis results displayed that the sample synthesized at the condition of temperature: $120^{\circ}C$, synthesis time: 12 hours, pressure: 1 bar exhibited a good crystal structure with uniform size of octahedral particles. The BET data revealed a high surface area of 1741.7 $m^2g^{-1}$ and a pore volume of 0.7137 $cm^3g^{-1}$and exhibiteda maximum $CO_2$ adsorption capacity of 170 mg/g of the sorbent at $25^{\circ}C$.

  • PDF

Air Monitoring of Persistent Organic Pollutants Using Passive Air Samplers (Passive Air Sampler를 이용한 잔류성 유기오염물질의 대기 모니터링)

  • Choi, Sung-Deuk;Chang, Yoon-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.5
    • /
    • pp.481-494
    • /
    • 2005
  • The monitoring of persistent organic pollutants (POPs) in the atmosphere is a basis for the study of the fate of POPs in multimedia environments. Recently, passive air samplers (PASs) for POPs have been developed. In this paper, we deal with the principle, properties, and applications of the PAS. The principle of PAS, which has no pump, is physical sorption of semi-volatile organic chemicals on various sorbent materials. The PAS is much smaller than a high-volume air sampler and does not need electricity. These properties of the PAS make it possible to conduct various-scaled environmental monitoring all over the world including the Arctic and Antarctic, but the major disadvantage of PAS is its long sampling periods up to 2 years. To date, four kinds of PAS have been developed: polyurethane foam (PUF), polymer-coated glass (POG), semi-permeable membrane devices (SPMDs), and XAD resin-based PAS. Among them, SPMDs have been commercialized and are most widely used now. Meanwhile, the POPs emitted from China have a large potential to influence the levels and fates of POPs in Korea. Since characteristics of PAS are quite useful to monitor long-range transport of POPs, the use of PAS is highly recommended.

Characterization of dry sorbents for $CO_2$ separation from MSW incineration flue gas (도시생활폐기물 소각장에서 배출되는 이산화탄소 포집용 건식 흡착제 연구)

  • Kim, Byung-Soon;Lee, Ju-Yeol;Kim, Shin-Do
    • Journal of the Korean Applied Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.318-324
    • /
    • 2010
  • In this study, commercial pellet type sorbents for the collection of $CO_2$ from a local municipal waste incinerator were prepared and characterized in terms of adsorption efficiency by varying the operating conditions of a field process. The concentration of $CO_2$ in the flue gas ranged from 8 to 10%, which entered the test packed bed. As a result of this experiment, the sorbent procured from A-company, which is mainly composed of calcium compounds, showed the highest adsorption efficiency. The regeneration efficiency was fairly low, however. It also was found that based on adsorption breakthrough time, the relatively low flow rate of 10 LPM into the bed allowed higher collection efficiency. The higher flow rate of 40 LPM, on the other hand, tended to decrease the retention of the adsorption.

Trends in Research and Technical Development of Sorbents for Hot Gas Desulfurization for H2S Removal (H2S 제거를 위한 고온건식 탈황제의 연구 및 기술개발동향)

  • Seo, Jun-Hyung;Baek, Chul-Seoung;Kwon, Woo Tech;Ahn, Ji-Whan;Cho, Kye-Hong
    • Resources Recycling
    • /
    • v.25 no.5
    • /
    • pp.14-27
    • /
    • 2016
  • Theoretical reviews of integrated gasification combined cycle one of the clean coal technologies and trends in the study and technology development for high temperature desulfurization sorbents were investigated. Reactivity, durability and abrasion resistance is an important key for development of high temperature desulfurization sorbents, the kind of things include calcium, zinc, manganese, iron and copper-based sorbents. Current status of high temperature desulfurization sorbents, manufacturing techniques of zinc-based sorbent in advanced countries has commercialized. In case of Korea, various research studies are underway to commercialize the Zn and non Zn-based high temperature desulfurization sorbents to cheaper and superior capability using various supports.

Desulfurization Efficiency of Lime Absorbent in In-Furnace Desulfurization as Fly Ash Binder in Power Plant (발전소 비산재를 결합재로 활용한 로내탈황용 석회 흡수제의 탈황효율)

  • Seo, Jun-Hyung;Baek, Chul-Seoung;Cho, Jin-Sang;Ahn, Ji-Whan;Yoon, Do-Young;Cho, Kye-Hong
    • Resources Recycling
    • /
    • v.27 no.3
    • /
    • pp.58-65
    • /
    • 2018
  • For the recycling of coal ash from the domestic circulating fluidized bed boilers, a lime-based sorbent with 0.2~0.4 mm size was prepared by using limestone powder and CFBC fly ash. Mixing a small amount of slaked lime in the lime-based absorbent lead the formation of calcium silicate on the surface of the particle and the strength of absorbent particle was improved. As a result of comparing the desulfurization characteristics, it was found that the conversion rate was about 10% higher than that of commercially available limestone desulfurization used in the furnace, which is confirmed that it can be used as a desulfurization absorbent.

Performance Analysis of Absorbent for Post-combustion CO2 Capture by Regeneration (연소 후 CO2 포집을 위한 흡수제의 재생반응에 의한 성능 해석)

  • KIL, TAEHYOUNG;LEE, DONGHO;JO, SUNGHO;YI, CHANGKEUN;PARK, YEONGSEONG;RYU, HOJUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.1
    • /
    • pp.83-94
    • /
    • 2016
  • Performance of absorbent for post-combustion $CO_2$ capture was measured and discussed. Fully saturated fresh absorbent (P2-15F) and absorbents sampled from absorption and regeneration reactor of continuous $CO_2$ capture process, P2-15A, P2-15R, respectively, were used as representative absorbents. Small scale fluidized bed reactor (0.05 m I.D., 0.8 m high) which can measure exhaust gas concentration and weight change simultaneously was used to analyze regeneration characteristics for those absorbents. Exhausted moles of $CO_2$ and $H_2O$ were measured with increasing temperature. $H_2O/CO$ ratio and working capacity were determined and discussed to confirm reason of reactivity decay after continuous operation. Moreover, possibility of side reaction was checked based on the $H_2O/CO_2$ mole ratio. Finally, suitable regeneration temperature range was confirmed based on the trend of working capacity with temperature.

Performance Evaluation of K-based Solid Sorbents Depending on the Internal Structure of the Carbonator in the Bench-scale CO2 Capture Process (벤치급 CO2 포집공정에서 흡수반응기의 내부구조에 따른 K-계열 고체흡수제의 성능평가)

  • Kim, Jae-Young;Lim, Ho;Woo, Je Min;Jo, Sung-Ho;Moon, Jong-Ho;Lee, Seung-Yong;Lee, Hyojin;Yi, Chang-Keun;Lee, Jong-Seop;Min, Byoung-Moo;Park, Young Cheol
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.419-425
    • /
    • 2017
  • In this study, the performance characteristics of the K-based sorbents (KEP-CO2P2, KEPCO RI, Korea) has been studied in relation with the heat exchanger structure and shape in a mixing zone of the carbonator in the bench-scale dry $CO_2$ capture process. Two types of heat exchangers (different structure and shape) were used in the carbonator as CASE 1 and CASE 2, in which the experiment has been continuously performed under the same operating conditions. During the continuous operation, working temperature of carbonator was 75 to $80^{\circ}C$, that of regenerator was 190 to $200^{\circ}C$, and $CO_2$ inlet concentration of the feed gas was 12 to 14 vol%. Especially, to compare the dynamic sorption capacity of sorbents, the differential pressure of the mixing zone in the carbonator was maintained around 400 to 500 mm $H_2O$. Also, solid samples from the carbonator and the regenerator were collected and weight variation of those samples was evaluated by TGA. The $CO_2$ removal efficiency and the dynamic sorption capacity were 64.3% and 2.40 wt%, respectively for CASE 1 while they were 81.0% and 4.66 wt%, respectively for CASE 2. Also, the dynamic sorption capacity of the sorbent in CASE 1 and CASE 2 was 2.51 wt% and 4.89 wt%, respectively, based on the weight loss of the TGA measurement results. Therefore, It was concluded that there could be a difference in the performance characteristics of the same sorbents according to the structure and type of heat exchanger inserted in the carbonator under the same operating conditions.