Coordinated Control Strategy for Power Systems with Wind Farms Integration Based on Phase-plane Trajectory

  • Zeng, Yuan;Yang, Yang;Qin, Chao;Chang, Jiangtao;Zhang, Jian;Tu, Jingzhe
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.20-29
    • /
    • 2018
  • The dynamic characteristics of power systems become more and more complex because of the integration of large-scale wind power, which needs appropriate control strategy to guarantee stable operation. With wide area measurement system(WAMS) creating conditions for realizing realt-ime transient stability analysis, a new coordinated control strategy for power system transient stability control based on phase-plane trajectory was proposed. When the outputs of the wind farms change, the proposed control method is capable of selecting optimal generators to balance the deviation of wind power and prevent transient instability. With small disturbance on the base operating point, the coordinated sensitivity of each synchronous generator is obtained. Then the priority matrix can be formed by sorting the coordinated sensitivity in ascending order. Based on the real-time output change of wind farm, coordinated generators can be selected to accomplish the coordinated control with wind farms. The results in New England 10-genrator 39-bus system validate the effectiveness and superiority of the proposed coordinated control strategy.

Complete and Incomplete Observability Analysis by Optimal PMU Placement Techniques of a Network

  • Krishna, K. Bala;Rosalina, K. Mercy;Ramaraj, N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1814-1820
    • /
    • 2018
  • State estimation of power systems has become vital in recent days of power operation and control. SCADA and EMS are intended for the state estimation and to communicate and monitor the systems which are operated at specified time. Although various methods are used we can achieve the better results by using PMU technique. On placing the PMU, operating time is reduced and making the performance reliable. In this paper, PMU placement is done in two ways. Those are 'optimal technique with pruning operation' and 'depth of unobservability' considering incomplete and complete observability of a network. By Depth of Unobservability Number of PMUs are reduced to attain Observability of the network. Proposed methods are tested on IEEE 14, 30, 57, SR-system and Sub systems (1, 2) with bus size of 270 and 444 buses. Along with achieving complete observability analysis, single PMU loss condition is also achieved.

Ship Repair Workers' Exposure to Asbestos by a Systematic Review in Korea (문헌 조사를 통한 국내 선박 수리 작업자들의 석면 노출 특성 분석)

  • Choi, Sang-Jun;Kwon, Hyo-Jung;Gwak, Su-Gyeong
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.135-141
    • /
    • 2012
  • This study was conducted to evaluate the characteristics of exposure to asbestos for ship repair workers in Korea by a systematic review. The number of articles studying asbestos exposure levels from ship repair workplaces was found to be 4. All asbestos concentration reported as either geometric mean and geometric standard deviation or ranges were transformed to arithmetic mean to estimate exposure level. In addition, weighted arithmetic means(WAMs) were calculated by weighing of the different number of samples. The WAM concentrations were 2.746 f/cc during asbestos dismantling work, 0.034 f/cc before asbestos dismantling work and 0.065 f/cc after working respectively. The maximum airborne concentration of asbestos during asbestos removal work was 7.02 f/cc which was 70 times higher than the occupational exposure limit of Korea, 0.1 f/cc. This study recommends that retrospective exposure to asbestos based on various ship types and operations should be assessed.

Power System Enhanced Monitoring through Strategic PMU Placement Considering Degree of Criticality of Buses

  • Singh, Ajeet Kumar;Fozdar, Manoj
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1769-1777
    • /
    • 2018
  • This paper proposes a method for optimal placement of Phasor Measurement Units (PMUs) considering system configuration and its attributes during the planning phase of PMU deployment. Each bus of the system is assessed on four diverse attributes; namely, redundancy of measurements, rotor angle and frequency monitoring of generator buses, reactive power deficiency, and maximum loading limit under transmission line outage contingency, and a consolidated 'degree of criticality' is determined using Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS). The major contribution of the proposed work is the development of modified objective function which incorporates values of the degree of criticality of buses. The problem is formulated as maximization of the aggregate degree of criticality of the system. The resultant PMU configuration extends complete observability of the system and majority of the PMUs are located on critical buses. As budgetary restrictions on utilities may not allow installation PMUs even at optimal locations in a single phase, multi-horizon deployment of PMUs is also addressed. The proposed approach is tested on IEEE 14-bus, IEEE 30-bus, New England (NE) 39-bus, IEEE 57-bus and IEEE 118-bus systems and compared with some existing methods.

Designing of Smart WAMAC Infra Architecture based on Synchro-Phasor (Synchro-Phasor 기반의 Smart WAMAC 인프라 아키텍쳐 설계)

  • Kim, Ji-Young;Woo, Doug-Je;Kim, Sang-Tae;Choi, Mi-Hwa;Kim, Yong-Kwang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1549-1559
    • /
    • 2010
  • Modern power system is operated and managed in closed network environment with treating a great variety of data, and requirement of real time power system data is more increasing. However, it is difficult for operators to fast evaluate the condition of power system using only isolation network system such as SCADA or EMS regarding unexpecting situations occurring. Recent technology achievement in areas of distributed computing, networking high speed communications and digital control as well as the availability of accurate GPS time source are rapidly becoming the enabling factors for the development of a new generation of real time power grid monitoring tools. In this paper, architecture of WAMAC which is the wide area monitoring and control system not only to control but also to monitoring in real time is proposed and the plan of integration interface with legacy system such as EMS for providing power system analysis base data effectively is suggested.