• Title/Summary/Keyword: K-RE100

Search Result 514, Processing Time 0.031 seconds

Analysis of Physical Properties for Various Compositions of Reusable LMG and LCV Micelle Gel

  • Kang, Jin Mook;Lee, Dong Han;Cho, Yu Ra;Hwang, Seon Bung;Ji, Young Hoon;Ahn, So Hyun;Keum, Ki Chang;Lee, Re Na;Cho, Sam Ju;Noh, Insup
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.175-179
    • /
    • 2016
  • In this study, we evaluated the reusable leuco malachite green (LMG) micelle gel properties dependent on various components of chemical concentration and compared with leuco crystal violet (LCV). The gels were delivered to 10, 20, 30, 40 and 50 Gy at 6 MV photon beam from linear accelerator and analyzed using spectrophotometry. We confirmed that the reusable LMG and LVC absorbance wavelength peak were made up at 630 nm and 600 nm respectively. The transparency of reusable LMG decreased with higher amount of trichloroacetic acid (TCAA) and lower reusable LMG dyes. 1 mM reusable LMG was the lowest transparency. The sensitivity was increased depending on lower trichloroacetic acid (TCAA) concentrations and the amount of suitable surfactant (Triton X-100), which was found to be 7 mM. However, we were not able to investigate sensitivity effects factor from reusable LMG dyes. The gel dosimeter containing 16 mM TCAA, 7 mM Triton X-100 gel dosimeter showed the highest sensitivity at $0.0021{\pm}0.0001cm^{-1}.Gy^{-1}$. The sensitivity of LCV was found to be higher than reusable LMG at $0.0037{\pm}0.0005cm^{-1}.Gy^{-1}$. The reusable LMG and LCV dose responses were shown to be $R^2=0.997$, $R^2=0.999$ respectively, as stable measurement results. Future research is necessary to improve dose sensitivity, dose rate dependency and gel fading with extensive chemical formulations.

The Operational Characteristics of CO2 5 ton/day Absorptive Separation Pilot Plant (이산화탄소 5 ton/day 흡수분리 Pilot Plant 운전 특성)

  • O, Min-Gyu;Park, So-Jin;Han, Keun-Hee;Lee, Jong-Seop;Min, Byoung-Moo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.1
    • /
    • pp.128-134
    • /
    • 2012
  • The pilot scale experiments can handle the flue gas up to 1,000 $Nm^3/hr$ for separation of carbon dioxide included in real flue gas at coal-fired power plant. The operational characteristics was analyzed with the main experimental variables such as flue gas flow rate, absorbent circulation rate using chemical absorbents mono-ethanolamine( MEA) and 2-amino-2-methyl-1-propanol(AMP). The more flue gas flow rate decreased in 100 $m^3/hr$ in the MEA 20 wt% experiments, the more carbon dioxide removal efficiency was increased 6.7% on average. Carbon dioxide removal efficiency was increased approximately 2.8% according to raise of the 1,000 kg/hr absorbent circulation rate. It also was more than 90% at $110^{\circ}C$ of re-boiler temperature. Carbon dioxide removal efficiency of the MEA was higher than that of the AMP. In the MEA(20 wt%) experiment, carbon dioxide removal efficiency(85.5%) was 10% higher than result(75.5%) of ASPEN plus simulation.

Phytotoxicity of imazosulfuron+fentrazamide in different cultivation type of rice (Imazosulfuron+fentrazamide 혼합제의 재배양식에 따른 벼의 약해)

  • Won, OK Jae;Kang, Kwang Sik;Park, Su Hyuk;Eom, Min Yong;Hwang, Ki Seon;Suh, Su Jeong;Pyon, Jong Yeong;Park, Kee Woong
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.1
    • /
    • pp.15-22
    • /
    • 2015
  • This study was conducted to evaluate the phytotoxicity of imazosulfuron+fentrazamide mixture in rice field. It is recommended that safe herbicide application was obtained at 3 cm of transplanting depth and in sandy loam or loam soil type. In the direct water seeding of rice, imazosulfuron+fentrazamide SC should be applied at least 10 days before sowing land ower than 25+100 g ai/ha. In case of imazosulfuron+fentrazamide SC application after sowing, If we use the herbicide 15 days after sowing, no herbicide symptoms will be detected even though the amounts of the herbicide increase. In the rice transplanting, it is recommended that imazosulfuron+fentrazamide GR is applied 5 days after transplanting. In case of sequential herbicide application, the imazosulfuron+fentrazamide SC application at 75+300 g ai/ha 15 or 20 days after transplanting after the application at 25+100 g ai/ha or 50+200 g ai/ha 3 days before sowing increases weed control efficacy and gives no phytotoxicity in the rice growth.

Investigation of Thermal Conductivity and Convective Heat Transfer of Alumina Nanofluids under Laminar Flow

  • Seung-Il, Choi;Hafizur-Rehman, Hafizur-Rehman;Eom, Yoon-Sub;Ji, Myoung-Kuk;Kim, Jun-Hyo;Chung, Han-Shik;Jeong, Hyo-Min
    • Journal of Power System Engineering
    • /
    • v.17 no.2
    • /
    • pp.78-86
    • /
    • 2013
  • In this research, dilute colloidal suspension alumina nanofluids were prepared by dispersing alumina nanoparticles in DI water and ethylene glycol as base fluids. Particle size analyzer and TEM test results revealed that the size of the alumina nanofluids(3wt% and 5wt%) with dispersion time 3hrs were 46nm and 60nm respectively. Thermal conductivity of these alumina nanofluids was measured by means of hot wire technique using a LAMBDA system. For water based alumina nanofluids, thermal conductivity enhancement was from 2.29% to 3.06% with 5wt% alumina at temperatures ranging from 15 to $40^{\circ}C$. Whereas in case of ethylene glycol based alumina nanofluids under the same temperature range, thermal conductivity enhancement was from 9.6% to 10% with 5wt% alumina. An enhancement of 37% average convective heat transfer was achieved with 5wt% alumina nanofluids at Re of 1,100.

First Report of Sclerotinia White Rot Caused by Sclerotinia nivalis on Panax ginseng in Korea

  • Cho, Hye Sun;Shin, Jeong-Sup;Kim, Jae-Hyun;Hong, Tae-Kyun;Cho, Dae-Hui;Kang, Je Yong
    • Research in Plant Disease
    • /
    • v.19 no.1
    • /
    • pp.49-54
    • /
    • 2013
  • Sclerotinia white rot disease was observed on 5 and 6-year-old ginseng (Panax ginseng) roots in Hongchun, Cheorwon, and Yanggu, Gangwon Province, Korea from 2006 to 2010. Symptoms included a brownish watery soft rot of the roots, and black sclerotia were often found on the rotten roots. The causal agent of the disease was identified as Sclerotinia nivalis based on cultural characteristics and sequence analyses of the internal transcribed spacer region of rDNA and ${\beta}$-tubulin gene with 100% sequence similarity. Pathogenicity tests were performed on 2-year-old ginseng roots with mycelium plugs without wounds. A watery soft rot of the roots and black sclerotia were observed 10 days after inoculation. These symptoms were identical to those observed on naturally infected roots. The same fungus was re-isolated from the lesions induced by artificial inoculation. This is the first report of sclerotinia white rot caused by S. nivalis on P. ginseng in Korea.

Flow Distribution and Pressure Loss in Subchannels of a Wire-Wrapped 37-pin Rod Bundle for a Sodium-Cooled Fast Reactor

  • Chang, Seok-Kyu;Euh, Dong-Jin;Choi, Hae Seob;Kim, Hyungmo;Choi, Sun Rock;Lee, Hyeong-Yeon
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.376-385
    • /
    • 2016
  • A hexagonally arrayed 37-pin wire-wrapped rod bundle has been chosen to provide the experimental data of the pressure loss and flow rate in subchannels for validating subchannel analysis codes for the sodium-cooled fast reactor core thermal/hydraulic design. The iso-kinetic sampling method has been adopted to measure the flow rate at subchannels, and newly designed sampling probes which preserve the flow area of subchannels have been devised. Experimental tests have been performed at 20-115% of the nominal flow rate and $60^{\circ}C$ (equivalent to Re ~ 37,100) at the inlet of the test rig. The pressure loss data in three measured subchannels were almost identical regardless of the subchannel locations. The flow rate at each type of subchannel was identified and the flow split factors were evaluated from the measured data. The predicted correlations and the computational fluid dynamics results agreed reasonably with the experimental data.

Usefulness of Serial Ultrasonography of the Rotator Cuff Repair (회전근 개 파열의 수술적 치료시 초음파 연속 검사의 유용성)

  • Park, Jae-Hyun;Choi, Won-Ki;Choi, Chang-Hyuk
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.2
    • /
    • pp.78-85
    • /
    • 2008
  • Purpose: The findings of preoperative magnetic resonance imaging (MRI) and ultrasonography (US) examination in the diagnosis of rotator cuff tear were then compared with the findings of arthroscopic examination, and to evaluate the postoperative integrity of rotator cuff using serial US examination. Methods: Between February and May 2008, 29 patients with rotator cuff tear had undergone preoperative US and MRI examination and subsequent arthroscopic examination. And the results of MRI and US were compared with intra-operative results of the arthroscopic examination. We observed the postoperative integrity of rotator cuff using serial (postoperative 2 weeks, 6 weeks, 3 months) US examination. Results: The sensitivity of US and MRI for identifying rotator cuff tear were 100% and 100%. The sensitivity of US and MRI were 95% and 82% in full thickness tear, and 50%, 33% in partial thickness tear, respectively. Overall accuracy of US and MRI were 86%, 69%. Among 22 patients were operated for full thickness tear, intra-operative gap formation was identified in 11 patients (50%, small to medium 2 cases, large to massive 9 cases) which were identified at 2 weeks postoperative US. We could find 5 re-tears (23%, small to medium 1 case, large to massive 4 cases) on 6 weeks postoperative US after passive range of motion (ROM) exercise, and could also find 7 re-tears (32%, small to medium 2 cases, large to massive 5 cases)on 3 months postoperative US after active ROM exercise. Conclusion: Serial US after arthroscopic rotator cuff repair was useful to differentiate intra-operative gap formation from postoperative re-tear. We found 5 retears (23%) at 6 weeks and 7 retears (32%) at 3 months postoperative US, it was useful to make treatment plan during postoperative rehabilitation.

  • PDF

Reduction of Patient Dose in Radiation Therapy for the Brain Tumors by Using 2-Dimensional Vertex or Oblique Vertex Beam Technique

  • Kim, Il-Han;Chie, Eui-Kyu;Park, Charn-Il
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.225-231
    • /
    • 2003
  • Up-front irradiation technique as 3-dimensional conformation, or intensity modulation has kept large proportion of brain tumors from being complicated with acute radiation reactions in the normal tissue during or shortly after radiotherapy. For years, we've cannot help but counting on 2-D vertex beam technique to reduce acute reactions in the brain tumor patients because we're not equipped with 3-dimensional planning system. We analyzed its advantages and limitations in the clinical application. From 1998 to 2001, vertex or oblique vertex beams were applied to 35 patients with primary brain tumor and 25 among them were eligible for this analysis. Vertex(V) plans were optimized on the reconstructed coronal planes. As the control, we took the bilateral opposed techniques(BL) otherwise being applied. We compared the volumes included in 105% to 50% isodose lines of each plan. We also measured the radiation dose at various extracranial sites with TLD. With vertex techniques, we reduced the irradiated volumes of contralateral hemisphere and prevented middle ear effusion at contralateral side. But the low dose volume increased outside 100%; the ratio of V to BL in irradiated volume included in 100%, 80%, 50% was 0.55+/-0.10, 0.61+/-0.10, and 1.22+/-0.21, respectively. The hot area within 100% isodose line almost disappeared with vertex plan; the ratio of V to BL in irradiated volume included in 103%, 105%, 108% was 0.14+/-0.14, 0.05./-0.17, 0.00, respectively. The dose distribution within 100% isodose line became more homogeneous; the ratio of volume included in 103% and 105% to 100% was 0.62+/-0.14 and 0.26+/-0.16 in BL whereas was 0.16+/-0.16 and 0.02+/-0.04 in V. With the vertex techniques, extracranial dose increased up to $1{\sim}3%$ of maximum dose in the head and neck region except submandibular area where dose ranged 1 to 21%. From this data, vertex beam technique was quite effective in reduction of unnecessary irradiation to the contralateral hemispheres, integral dose, obtaining dose homogeneity in the clinical target. But it was associated with volume increment of low dose area in the brain and irradiation toward the head and neck region otherwise being not irradiated at all. Thus, this 2-D vertex technique can be a useful quasi-conformal method before getting 3-D apparatus.

Research on Re-creational Experiment and Technique of Gold Powder Painting for Goryeo Gold-painted Porcelain (고려시대 금채자기의 채색기법 재현실험 연구)

  • Hwang, Hyun-Sung;Lee, Da-Hae
    • Journal of Conservation Science
    • /
    • v.27 no.4
    • /
    • pp.403-414
    • /
    • 2011
  • This study is re-creational experiment of Goryeo gold-painted decoration based on the research of the gold remaining and gold painting technique on the two pieces of Goryeo gold-painted celadon and the three pieces of Chinese gold-painted porcelain on North Song period which ones have been owned by National Museum of Korea since 2007. For the observation of glue state and color developing ability, four kinds of agglutinative agent and gold powder were mixed over the porcelain sherds, then gradually fired from $100^{\circ}C$ to $1200^{\circ}C$. Visual effect and ideal temperature were measured. Among of them, oil and glue showed the best results in glue state and color developing ability. Through those results, the entire Goryeo engraved celadon were reproduced in modern facilities. Oil and glue were gold-painted over the glaze then it was fired at the ideal temperature 700 to $800^{\circ}C$. For observation the binding condition, the gold-painting cross section was looked by the scanning electron microscope (SEM). As the result, oil and glue did not make much difference in Agglutinative agent, but gold was good, the color developing ability, however, in the case of oil, the edge of gold is curled because of its interfacial tension, and it is not dried well at room temperature so the working property is not as good as the glue. Glue more effective in terms of work efficiency, but color developing ability to fall slightly in this experiment were able to see through.

Adsorption and Desorption Dynamics of Ethane and Ethylene in Displacement Desorption Process using Faujasite Zeolite (제올라이트(faujasite)를 이용한 치환탈착공정에서 에탄, 에틸렌의 흡, 탈착 동특성)

  • Lee, Ji-In;Park, Jong-Ho;Beum, Hee-Tae;Yi, Kwang-Bok;Ko, Chang-Hyun;Park, Sung Youl;Lee, Yong-taek;Kim, Jong-Nam
    • Korean Chemical Engineering Research
    • /
    • v.48 no.6
    • /
    • pp.768-775
    • /
    • 2010
  • Adsorption dynamics of ethane/ethylene mixture gas and desorption dynamics during the displacement desorption with propane as a desorbent in the column filled with faujasite adsorbent were investigated experimentally and theoretically. The simulation that adopted heat and mass balance and an ideal adsorbed solution theory (IAST) for the multicomponent adsorption equilibrium well predicted the experimental breakthrough curves of the adsorption and desorption. At the adsorption breakthrough experiments, roll-ups of ethane increased as the adsorption pressure increased and the adsorption temperature decreased. During the displacement desorption with propane in the column saturated with ethane/ethylene mixture gas, almost 100% of ethylene was obtained for a certain time interval. The adsorption strength of the desorbent greatly affected the adsorption and re-adsorption dynamics of ethylene. The re-adsorption capacity for ethylene has been greatly reduced when iso-propane, which is stronger desorbent than propane, was used as desorbent. It was found from the simulation that the performance of the displacement desorption process would be superior when the ratio of ${(q_s{\times}b)}_{C_2H_4}/{(q_s{\times}b)}_{C_3H_s}$ was 0.83, that is, the adsorption strengths of ethylene and the desorbent were similar.