Study on Design of high Efficient Cooling System for Low Temperature Furnace in Semiconductor Processing (반도체 공정용 저온 열처리로의 고효율 냉각시스템 설계에 관한 연구)

  • Jeoung, Du-Won;Suh, Ma-Son;Kim, Kwang-Sun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.4
    • /
    • pp.71-76
    • /
    • 2010
  • According to recent changes in industry for semiconductor devices, a low-temperature treatment has become a necessity. These changes relate to size refinement and the development of new materials. While variation in cooling efficiency does not affect the yield when using a high-temperature treatment, uniform cooling efficiency is necessary avoid "inconsistencies/bends" in low temperature treatments. However it is difficult to increase temperature stabilization in low temperature treatments. In this paper, using CFD (Computer Fluid Dynamics), we analyze and manipulate the design and input of the low-temperature system to attempt to control for temperature variations within the quartz tube, of which airflow appears to be a predominant factor. This simulation includes variable inputs such as airflow rate, head pressure, and design manipulations in the S.C.U. (Super Cooling Unit).

Low-Cycle Fatigue in Quenched Boron Steel Sheet Due to Hot Stamping (열간 성형된 보론강판의 저주기 피로 특성)

  • Jang, Won-Seok;Suh, Chang-Hee;Oh, Sang-Kyun;Kim, Dong-Bae;Sung, Jee-Hyun;Jung, Yun-Chul;Kim, Young-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1419-1425
    • /
    • 2010
  • Boron steel sheet is suitable for fabricating automobile parts because it is very strong and has low weight. Recently, many car makers are investigating the feasibility of fabricating the chassis part of automobiles using boron steel. In order to use boron steel sheets to fabricate the chassis part of automobiles, much better material property of low cycle fatigue life as well as high formability during hot stamping is required. Therefore, the low-cycle fatigue life of hot-stamped quenched boron steel was investigated in this study. The fatigue life observed at low strain amplitude was longer than that of an as-received boron steel sheet. However, the fatigue life reduced at high strain amplitude because of the low ductility and low fracture toughness of martensite, which was produced as a result of hot stamping.

The Use of Ojeok-san in Low Back Pain Patients : Results of a Telephone Survey (요통진료 및 오적산 사용현황파악을 위한 전화설문조사)

  • Shin, Kyung-Min;Jang, Min-Gee;Kim, Eun-Jung;Kim, Sun-Woong;Lee, Jae-Dong;Kim, Kap-Sung;Lee, Seung-Deok
    • Journal of Acupuncture Research
    • /
    • v.27 no.2
    • /
    • pp.71-78
    • /
    • 2010
  • Objectives : This survey was accomplished to find out how Korean medical doctors take Ojeok-san prescriptions for low back pain in clinical practice. Methods : The survey questionnaire was developed by the committee of experts who major in acupuncture & moxibustion or statistics for acupuncture clinical trial protocol development. 306 persons having more than 5 years experience were randomly selected from a list of Korean medical doctors. Telephone interviews with them were conducted by the well-trained interviewers between March 21 and April 4 in 2009 and the computerized data were analyzed by STATA 9.0 SE version(Stata Corp, Colleg Station Tex, USA) statistical program. Results : 1. 192 out of 306(65.1%) Korean medical doctors taked Ojeok-san prescriptions for musculoskeletal disorders patients and 183 out of 192(95.3%) Korean medical doctors taked Ojeok-san prescriptions for low back pain treatment. 2. The rate of low back pain patients, '20~30%' was 99 people(33.6%) and the rate of Ojeok-san prescriptions for low back pain treatment, 'below 10%' was 65 people(35.5%). 3. In Ojeok-san effect of low back pain treatment, 'greate effects' 29.5%, 'tolerable effects' 66.7%, 'no effects' 3.8% were selected. In granule extracts effect, 'similar to Original herbs' 9.8%, 'unlike to Original herbs' 90.2% were selected. Conclusions : In our telephone survey, Korean medical doctors taked Ojeok-san prescriptions for low back pain treatment. Further research on this issue is needed.

Proposal of Applying the Exercise Program for the Prevention of Work-related Chronic Low Back Pain

  • Yang, Yeong-Ae;Kim, Seong-Su;Hur, Jin-Gang;An, Sun-Joung;Kim, Hee-Soo;Cha, Su-Min;Heo, Jun;Park, Yun-Hee;Park, Bo-Ra
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.571-579
    • /
    • 2011
  • Objective: The purpose of this research is to provide exercise programs for the prevention of work related chronic back pain. Background: In order to prevent musculoskeletal disease, including proper medical care health promotion programs are needed. Method: This is a research of musculoskeletal disease looking at 618 workers working at a car engine manufacturing factory from April to July of 2008. Through questionnaire specific areas of musculoskeletal diseases experienced by the workers were identified and preventative exercise program for chronic low back pain was recommended. Result: Research showed that of the musculoskeletal disease experienced by the workers, 197 presented with low back pain, 171 presented with shoulder pain, 64 presented with neck pain and 44 presented with knee pain. The symptoms of low back pain included stiffness(143), twinge and burning sensation(24) and absence of sensation(19). Using this result 4 types of exercise programs were recommended for prevention of chronic low back pain. Conclusion: Preventative exercise programs recommended for the workers in this research is easily accessible for the workers. Use of the suggested exercise programs will inevitably decrease work related low back pain. Also 2 other recommendations were made: 1) Internal structural change may be necessary using ergonomics. 2) More exercise programs to be used to increase adaptation and tolerance of joints and muscles that are constantly used for repetitive work. Application: This study can be used to provide for the prevention of work-related Chronic Low Back pain.

A Low- Viscousity, Highly Thermally Conductive Epoxy Molding Compound (EMC)

  • Bae, Jong-Woo;Kim, Won-Ho;Hwang, Seung-Chul;Choe, Young-Sun;Lee, Sang-Hyun
    • Macromolecular Research
    • /
    • v.12 no.1
    • /
    • pp.78-84
    • /
    • 2004
  • Advanced epoxy molding compounds (EMCs) should be considered to alleviate the thermal stress problems caused by low thermal conductivity and high elastic modulus of an EMC and by the mismatch of the coefficient of thermal expansion (CTE) between an EMC and the Si-wafer. Though A1N has some advantages, such as high thermal conductivity and mechanical strength, an A1N-filled EMC could not be applied to commercial products because of its low fluidity and high modules. To solve this problem, we used 2-$\mu\textrm{m}$ fused silica, which has low porosity and spherical shape, as a small size filler in the binary mixture of fillers. When the composition of the silica in the binary filler system reached 0.3, the fluidity of EMC was improved more than twofold and the mechanical strength was improved 1.5 times, relative to the 23-$\mu\textrm{m}$ A1N-filled EMC. In addition, the values of the elastic modules and the dielectric constant were reduced to 90%, although the thermal conductivity of EMC was reduced from 4.3 to 2.5 W/m-K, when compared with the 23-$\mu\textrm{m}$ A1N-filled EMC. Thus, the A1N/silica (7/3)-filled EMC effectively meets the requirements of an advanced electronic packaging material for commercial products, such as high thermal conductivity (more than 2 W/m-K), high fluidity, low elastic modules, low dielectric constant, and low CTE.

Low-Power Direct Conversion Transceiver for 915 MHz Band IEEE 802.15.4b Standard Based on 0.18 ${\mu}m$ CMOS Technology

  • Nguyen, Trung-Kien;Le, Viet-Hoang;Duong, Quoc-Hoang;Han, Seok-Kyun;Lee, Sang-Gug;Seong, Nak-Seon;Kim, Nae-Soo;Pyo, Cheol-Sig
    • ETRI Journal
    • /
    • v.30 no.1
    • /
    • pp.33-46
    • /
    • 2008
  • This paper presents the experimental results of a low-power low-cost RF transceiver for the 915 MHz band IEEE 802.15.4b standard. Low power and low cost are achieved by optimizing the transceiver architecture and circuit design techniques. The proposed transceiver shares the analog baseband section for both receive and transmit modes to reduce the silicon area. The RF transceiver consumes 11.2 mA in receive mode and 22.5 mA in transmit mode under a supply voltage of 1.8 V, in which 5 mA of quadrature voltage controlled oscillator is included. The proposed transceiver is implemented in a 0.18 ${\mu}m$ CMOS process and occupies 10 $mm^2$ of silicon area.

  • PDF

RF Energy Harvesting and Charging Circuits for Low Power Mobile Devices

  • Ahn, Chang-Jun;Kamio, Takeshi;Fujisaka, Hisato;Haeiwa, Kazuhisa
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.4
    • /
    • pp.221-225
    • /
    • 2014
  • Low power RF devices, such as RFID and Zigbee, are important for ubiquitous sensing. These devices, however, are powered by portable energy sources, such as batteries, which limits their use. To mitigate this problem, this study developed RF energy harvesting with W-CDMA for a low power RF device. Diodes are required with a low turn on voltage because the diode threshold is larger than the received peak voltage of the rectifying antenna (rectenna). Therefore, a Schottky diode HSMS-286 was used. A prototype of RF energy harvesting device showed the maximum gain of 5.8dBi for the W-CDMA signal. The 16 patch antennas were manufactured with a 10 dielectric constant PTFT board. In low power RF devices, the transmitter requires a step-up voltage of 2.5~5V with up to 35 mA. To meet this requirement, the Texas Instruments TPS61220 was used as a low input voltage step-up converter. From the evaluated result, the achievable incident power of the rectenna at 926mV to operate Zigbee can be obtained within a distance of 12m.

Desgin of Low-power, Low-noise Preamplifier for Digital Hearing-Aids (디지털 보청기를 위한 저전력, 저잡음 전치증폭기 설계)

  • Im, Saemin;Park, Sang-Gyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.219-225
    • /
    • 2012
  • A low-power, low-noise pre-amplifier for digital hearing-aid application is designed. This pre-amplifier amplifies single-ended signal from an electret microphone, and produces differential output to be delivered to an ADC. It has a variable gain of 3.6, 7.2, 14.4 and 28.8 with a bandwidth between 100Hz~10kHzon. The measurement results show 85 dB of SNR, 0.05 % of harmonic distortion and $200{\mu}W$ of power consumption with 1.2V supply.

Low ionization state plasma in CMEs

  • Lee, Jin-Yi;Raymond, John C.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.115.1-115.1
    • /
    • 2012
  • The Ultraviolet Coronagraph Spectrometer on board the Solar and Heliospheric Observatory (SOHO) observes low ionization state coronal mass ejection plasma at ultraviolet wavelengths. The CME plasmas are often detected in O VI ($3{\times}10^5K$), C III ($8{\times}10^4K$), $Ly{\alpha}$, and $Ly{\beta}$. Earlier in situ observations by the Solar Wind Ion Composition Spectrometer (SWICS) on board Advanced Composition Explorer (ACE) have shown mostly high ionization state plasmas in interplanetary coronal mass ejections (ICME) events, which implies that most CME plasma is strongly heated during its expansion in solar corona. In this analysis, we investigate whether the low ionization state CME plasmas observed by UVCS occupy small enough fractions of the CME volume to be consistent with the small fraction of ICMEs measured by ACE that show low ionization plasma, or whether the CME must be further ionized after passing the UVCS slit. To do this, we determine the covering factors of low ionization state plasma for 10 CME events. We find that the low ionization state plasmas in CMEs observed by UVCS show small covering factors. This result shows that the high ionization state ICME plasmas observed by the ACE results from a small filling factor of cool plasma. We also find that the low ionization state plasma volumes in faster CMEs are smaller than in slower CMEs. Most slow CMEs in this analysis are associated with a prominence eruption, while the faster CMEs are associated with X-class flares.

  • PDF

Effect of Load Modeling on Low Frequency Current Ripple in Fuel Cell Generation Systems

  • Kim, Jong-Soo;Choe, Gyu-Yeong;Kang, Hyun-Soo;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.307-318
    • /
    • 2010
  • In this work, an accurate analysis of low frequency current ripple in residential fuel cell power generation systems is performed based on the proposed residential load model and its unique operation algorithm. Rather than using a constant dc voltage source, a proton exchange membrane fuel cell (PEMFC) model is implemented in this research so that a system-level analysis considering the fuel cell stack, power conditioning system (PCS), and the actual load is possible. Using the attained results, a comparative study regarding the discrepancies of low frequency current ripple between a simple resistor load and a realistic residential load is performed. The data indicate that the low frequency current ripple of the proposed residential load model is increased by more than a factor of two when compared to the low frequency current ripple of a simple resistor load under identical conditions. Theoretical analysis, simulation data, and experimental results are provided, along with a model of the load usage pattern of low frequency current ripples.