• Title/Summary/Keyword: K-Box

Search Result 3,218, Processing Time 0.031 seconds

Assessment of Bicycle Left-turn Traffic Control Strategies at Signalized Intersections (신호교차로의 자전거 좌회전 운영방안 평가에 관한 연구)

  • Lee, Chung Min;Lee, Sang Soo;Cho, Hanseon;Nam, Doohee
    • Journal of Korean Society of Transportation
    • /
    • v.32 no.6
    • /
    • pp.579-588
    • /
    • 2014
  • In this study, three signal control strategies such as Bike box, Hook-turn, and 6-phase were assessed for various traffic conditions at signalized intersections incorporating bicycle left-turn traffic. Results showed that the size of a waiting zone mainly affected the performance of signal control in both Bike box and Hook-turn. Both Bike box and Hook-turn yielded an identical vehicle delay, but Bike box produced less bicycle delay than Hook-turn by 2.5~29.9 sec/veh for undersaturated traffic conditions. For saturated traffic condition, Bike box produced less vehicle delay than Hook-turn and 6-phase strategies, but bicycle delay was found to increase at the 700 vph of bicycle traffic compared to 6-phase. Bicycle delay was greatly increased under Hook-turn and Bike box strategies when bicycle traffic was greater than 300 vph and 500 vph, respectively. It was also shown that bicycle delay could be significantly reduced by providing appropriate size of queueing space. In addition, Bike box was likely to yield less vehicle and bicycle delay than Hook-turn for traffic volume patterns investigated in this study.

Development of the Corrugated fiberboard Box for Cold-chain Distribution of Chinese Cabbage (배추의 저온유통용 골판지포장상자 개발)

  • Lee, Won-Og;Yun, Hong-Sun;Jeong, Hoon;Lee, Hyun-dong;Cho, Kwang-Hwan;Kim, Man-Soo
    • Food Science and Preservation
    • /
    • v.10 no.1
    • /
    • pp.23-27
    • /
    • 2003
  • This study was conducted to develop the corrugated fiberboard box which is suitable to pre-cooling and low temperature distribution of chinese cabbage Consider from a cooling performance viewpoint, the folding type box with 5.4% vent hole ratio was most efficient for fast cooling and even temperature distribution in the packaging box. At the end of storage periods, the compressive strength of the folding type box was less than the bliss type box. However, the compressive strength of the folding type box after storage was higher than required safety compressive strength for long term storage. So the folding type box was considered to have no problems toy practical use. The shelf-life of the chinese cabbage packaged with the developed box was 6∼7 days which was 2∼3 days longer than usual packaging.

Safety Countermeasure of the distribution box of service wire (인입선 분기함의 안전대책에 관한 연구)

  • Ha, Tae-Hyun;Bae, Jeong-Hyo;Lee, Hyun-Goo;Kim, Dae-Kyeong;Ha, Yoon-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.246-248
    • /
    • 2004
  • The lower voltage distribution box of service wire has been usually employed to supply an electric power to the consumers through low voltage overhead line. Now-a-days, electric shock accident at the distribution box of service wire installed in the seashore areas has been often occurred. The reason is mainly due to the electric leakage in the distribution box of service wire. This paper described insulation breakdown mechanism of distribution box of service wire, analysis of electric shock path and safety countermeasure of distribution box of service wire.

  • PDF

Torsional analysis for multiple box cells using softened truss model

  • Yang, Daili;Fu, Chung C.
    • Structural Engineering and Mechanics
    • /
    • v.5 no.1
    • /
    • pp.21-32
    • /
    • 1997
  • A new torsional analysis method for multiple cell box based on the Softened Truss Model Theory was developed. This softened truss model unifies shear and torsion to address the problem associated with a torque applied on a box. The model should be very useful for the analysis of a reinforced concrete box under torque, especially for the bridge superstructure with multiple cell box sections.

Monitoring of Atmospheric Corrosivity inside Steel Upper Box Girder in Yeongjong Grand Bridge

  • Li, SeonYeob
    • Corrosion Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.87-94
    • /
    • 2011
  • The typical corrosion prevention method inside the steel upper box girder in a suspension bridge involves the use of paints. However, in an effort to reduce environmental impact and cost, the suspension portion of the Yeongjong Bridge, Korea utilizes dehumidification systems to control humidity and prevent corrosion inside its box girder. Maintaining a uniform humidity distribution at the proper level inside the box girder is critical to the successful corrosion control. In this study, the humidity and the resultant atmospheric corrosivity inside the box girder of the Yeongjong Bridge was monitored. The corrosion rate of the steel inside the box girder was obtained using thin-film electrical resistance (TFER) corrosion sensors. Time-of-wetness (TOW) measurements and the deposition rates of atmospheric pollutants such as $Cl^{-}$ and $SO_{x}$ were also obtained. Classification of the atmospheric corrosivity inside the box girder was evaluated according to ISO 9223. As a result, no corrosion was found in the upper box girder, indicating that the dehumidification system used in the Yeongjong Bridge is an effective corrosion control method.

The Implementation of sensor network and CMS server in R.Box (R.Box에서의 센서 네트워크와 CMS 서버 구현)

  • Kim, JinGyeong;Ra, SangYong;Choi, JaeHong;Lee, JunDong
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2018.01a
    • /
    • pp.77-78
    • /
    • 2018
  • 인터넷과 사물의 결합이 급속도로 진행되며 IoT(Internet of Things, 사물인터넷)의 활성화 역시 앞당겨지고 있다. 최근 IoT 기술 및 서비스와 관련하여 가정, 공장 등의 다양한 장소와 공기청정기, 체온계 등의 제품에도 IoT 기술이 접목된 서비스가 제공되고 있다. 본 논문에서는 일반목적의 IoT 허브인 R.Box의 센서 네트워크와 R.Box와 센서를 통제, 제어하며 데이터 저장과 간단한 통계를 확인할 수 있는 CMS(Content Management System) 기능을 하는 서버 구현에 대해 설명한다. R.Box는 라즈베리 파이를 이용해 제작되었으며 사용자는 서버에 접속해 R.Box와 센서의 정보, 측정된 값을 확인하고 수정, 삭제, 검색 등의 기능을 사용할 수 있다.

  • PDF

Reduction of Heat Generation from Junction Box in 3 kW Photovoltaic Power Generation System

  • Yun, Jung-Hyun;Sun, Ki-Ju;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.1
    • /
    • pp.21-24
    • /
    • 2016
  • A junction box used in a 3 kW photovoltaic power generation system plays a role in collecting and supplying the direct current voltage produced by photovoltaic modules to an inverter. It is also used for facilitating maintenance checks and protecting the module and inverter by keeping the voltage constant. As for the junction box, using it in a parallel connection creates a difference between the setup modules. In order to compensate, an inverse voltage diode is used. But the high-power created through the solar generator can be delivered to the inverter through the inverter regularly. Therefore, a component can break down due to excess heat. And consequently short circuits and electric leakage occurs. In this study, using a junction box that enabled the bypass of high electric power, it was possible to reduce heat generation by approximately 35℃ when compared to a standard junction box.

The Improvement of Junction Box Within Photovoltaic Power System

  • Sun, Ki-Ju;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.6
    • /
    • pp.359-362
    • /
    • 2016
  • In the PV (Photovoltaic) power system, a junction box collects the DC voltage generated from the PV module and transfers it to the PCS (power conditioning system). The junction box prevents damage caused by the voltage difference between the serially connected PV modules and provides convenience while repairing or inspecting the PV array. In addition, the junction box uses the diode to protect modules from the inverse current when the PV power system and electric power system are connected for use. However, by using the reverse blocking diode, heat is generated within the junction box while generating electric power, which decreases the generating efficiency, and causes short circuit and electric leakage. In this research, based on the purpose of improving the performance of the PV module by decreasing the heat generation within the junction box, a junction box with a built-in bypass circuit was designed/manufactured so that a certain capacity of current generated from the PV module does not run through the reverse blocking diode. The manufactured junction box was used to compare the electric power and heating power generated when the circuit was in the bypass/non-bypass modes. It was confirmed that the electric power loss and heat generation indicated a decrease when the circuit was in the bypass mode.

A Study on the Development of the Limit Switch Box for Corrosion Protection (방식형 리미트 스위치 박스의 개발에 관한 연구)

  • Lee S.H.;Go S.J.;Lee M.C.;Kim C.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.836-839
    • /
    • 2005
  • A limit switch box is used for a indicator of a valve actuator. This device indicates an opening and closing of a valve or throttle in a valve actuator. In a ship, equipments are required safety and robustness because of a rough environment and a specific condition during a voyage. However, the limit switch box is used in an indoor environment generally. In order to evaluate the endurance of the limit switch box used in an indoor environment, the endurance tests against salt water have been conducted. Experiment results showed that the limit switch box was corroded severely. Thus, this study developed a new limit switch box which can be used at an outdoor environment. The housing of the developed limit switch box was made by an stainless steel to prevent corrosion.

  • PDF