• 제목/요약/키워드: K-80 Closed

검색결과 167건 처리시간 0.027초

왕수를 이용한 중금속 오염토양에서의 추출방안 연구 (Heavy Metals Extraction from Contaminated Soils using Aqua Regia Extraction)

  • 이덕영;정선국;손영규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제23권2호
    • /
    • pp.15-22
    • /
    • 2018
  • Aqua regia extraction for the quantification of heavy metals and As in contaminated soils was investigated as one of preliminary steps for on-site monitoring using sensor technology. Soil samples were taken from closed railway depot, closed mines, and closed refinery and various extraction conditions including $30^{\circ}C/15min$, $30^{\circ}C/30min$, $30^{\circ}C/60min$, $30^{\circ}C/120min$, $80^{\circ}C/15min$, $80^{\circ}C/30min$, $80^{\circ}C/60min$, $80^{\circ}C/120min$ were tested. The optimal extraction condition was determined as $80^{\circ}C/60min$ because the extraction efficiencies of Zn were relatively low and did not reach the targeted level (80-100% of original concentrations) for $30^{\circ}C$ conditions. It was found that the fractionation of heavy metals and As using the sequential extraction method was useful to understand the degree of metal extraction. In order to enhance the extraction efficiency within short extraction time, ultrasound technology using a 20 kHz horn-type sonicator was additionally used for $30^{\circ}C/15min$. It was revealed that ultrasound could significantly enhance the extraction efficiency and pulsed irradiation showed higher efficiency than continuous irradiation due to the less formation of bubble clouds. However high temperature condition ($80^{\circ}C$) was required to achieve high extraction efficiency for Zn in spite of the use of ultrasound.

Coercivity of Hot-pressed Compacts of Nd-Fe-B-type HDDR-treated Powder

  • Abdul Matin, Md.;Kwon, Hae-Woong;Lee, Jung-Goo;Yu, Ji-Hun
    • Journal of Magnetics
    • /
    • 제19권2호
    • /
    • pp.106-110
    • /
    • 2014
  • $Nd_{12.5}Fe_{80.6}B_{6.4}Ga_{0.3}Nb_{0.2}$ HDDR-treated powder was compacted by hot-pressing using different configurations of dies and heating rates. The die configurations were especially different in terms of the evacuation system that was used in heating for hot-pressing. The coercivity in the compacts was influenced by the evacuation system of the die and heating rate. In spite of the identical hot-pressing temperature and heating rate, coercivity was radically reduced above $600^{\circ}C$ in the compacts prepared in the closed-type die compared to that in the compacts prepared in the open-type die. The coercivity in the compacts prepared in the closed-type die decreased with increasing heating rate and the value further increased when extreme high heating rate was employed. $Nd_{12.5}Fe_{80.6}B_{6.4}Ga_{0.3}Nb_{0.2}$ HDDR-treated powder contained a significant amount of residual hydrogen (approx. 1500 ppm) in the form of $Nd_2Fe_{14}BH_x$ hydride. The dramatic coercivity decrease in the compact prepared in the closed die is attributed to the disproportionation of $Nd_2Fe_{14}BH_x$ hydride. High coercivity is mainly due to the effective desorption of hydrogen or the suppression of hydrogen-related disproportionation upon hot-pressing.

Investigation of Boiling Heat Transfer Characteristics of Two-Phase Closed Thermosyphons with Various Internal Grooves

  • Han, Ku-Il;Cho, Dong-Hyun;Park, Jong-Un
    • Journal of Mechanical Science and Technology
    • /
    • 제17권11호
    • /
    • pp.1739-1745
    • /
    • 2003
  • The boiling heat transfer characteristics of two-phase closed thermosyphons with internal grooves are studied experimentally and a simple mathematical model is developed to predict the performance of such thermosyphons. The study focuses on the boiling heat transfer characteristics of a two-phase closed thermosyphons with copper tubes having 50, 60, 70, 80, 90 internal grooves. A two-phase closed thermosyphon with plain copper tube having the same inner and outer diameter as those of grooved tube is also tested for comparison. Methanol is used as working fluid. The effects of the number of grooves, the operating temperature, the heat flux are investigated experimentally. From these experimental results, a simple mathematical model is developed. In the present model, boiling of liquid pool in the evaporator is considered for the heat transfer mechanism of the thermosyphon. And also the effects of the number of grooves, the operating temperature, the heat flux are brought into consideration. A good agreement between the boiling heat transfer coefficient of the thermosyphon estimated from experimental results and the predictions from the present mathematical model is obtained. The experimental results show that the number of grooves and the amount of the working fluid are very important factors for the operation of thermosyphons. The two-phase closed thermosyphon with copper tubes having 60 internal grooves shows the best boiling heat transfer performance.

열린사슬운동과 닫힌사슬운동이 넙다리네갈래근의 근 활성도에 미치는 영향 (The Effects of Quadriceps Femoris Muscle activation by Closed and Open kinetic chain Exercises)

  • 김형수;김은영;한지원
    • 대한통합의학회지
    • /
    • 제3권1호
    • /
    • pp.71-80
    • /
    • 2015
  • Purpose: The purpose of this study was to compared the muscle activities of vastus medialis, vastus lateralis, rectus femoris in open kinetic chain and closed kinetic chain. Methods: Subjects of the study were 30 adults students. They were divided into 2 group, one for open kinetic chain and other for closed kinetic chain of extension, flexion, the maximum extension for vastus medialis, vastus latarealis, rectus femoris muscle activation. Results: Rectus femoris increased open kinetic chain group about all posture and vastus medialis increased open kinetic chain group about the maximum extension and flexion. and vastus lateralis increased open kinetic chain group about the maximum extension and flexion. Conclusion: Muscle activation are at the highest with the open kinetic chain in vastus medialis, vastus lateralis, rectus femoris. probably steady exercise thinked for open kinetic chain and closed kinetic chain.

PAIRWISE FUZZY S-CLOSED BITOPOLOGICAL SPACES

  • Park, Jin-Han;Lee, Bu-Young;Son, Mi-Jung
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1996년도 추계학술대회 학술발표 논문집
    • /
    • pp.77-80
    • /
    • 1996
  • In this paper, we generalize the concept of fuzzy S-closed spaces due to Mukherjee and Ghosh [8] into fuzzy bitopological setting and investigate some of its properties using the concepts of (${\tau}_i$, ${\tau}_j$)-semi-closure and related notions in fuzzy setting.

  • PDF

Effects of Dried Days on Properties of Seawater and Freshwater Flooded CSPE in NPPs

  • Jeon, Hwang-Hyun;Lee, Jeong-U;Jeon, Jun-Soo;Lee, Seung-Hoon;Shin, Yong-Deok
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1162-1168
    • /
    • 2015
  • Accelerated thermal aging of chlorosulfonated polyethylene (CSPE) was performed for 0 days, 80.82 days, and 161.63 days at 100℃, which is equivalent to 0 y, 40 y, and 80 y of aging, respectively, at 50℃. After freshwater flooding, the volume electrical resistivity of CSPE was highest after 180 days of drying, and its insulating property recovered when dried for more than 300 days. The dielectric constant of the CSPE was not measured after seawater flooding. The dielectric constant of the accelerated thermally aged CSPE was higher after freshwater flooding than that before seawater flooding. The bright, open pores of CSPE were converted into dark, closed pores after seawater flooding, and the dark, closed pores of the accelerated thermally aged CSPE samples were partly converted into bright, open pores after freshwater flooding. The apparent density of CSPE increased slightly whereas its elongation at break (EAB) decreased until 80 y of accelerated thermal aging before seawater flooding. The peak binding energies of oxygen in the non-accelerated and accelerated thermally aged CSPE for 40 y and 80 y were shifted by more than 1.0 eV after seawater and freshwater flooding. The CH2 content in the non-accelerated and accelerated thermally aged CSPE for 40 y and 80 y after seawater flooding for 5 days was lower than that before seawater flooding whereas atoms such as Cl, O, Pb, Al, Si, Sb, and S that are related to conducting ions such as Na+, Cl-, Mg2+, SO4 2-, and K+ were relatively increased.

Clinical Study of Acupotomy Treatment for Tarsal Tunnel Syndrome

  • Fu, Xinyi;Lee, Mira;Guo, Changqing
    • Journal of Acupuncture Research
    • /
    • 제37권2호
    • /
    • pp.118-122
    • /
    • 2020
  • Background: Compared with conventional closed therapy, acupotomy has the advantages of lower cost, convenient application, and better single and long-term effects. The aim of this study was to explore the clinical effect of acupotomy in the treatment of Tarsal Tunnel syndrome. Methods: There were 80 patients enrolled into the study who were randomly assigned to either the acupotomy or closed therapy group, with 40 patients in each group. The acupotomy group was treated once every 6 days, on 3 occasions for the duration of treatment, and the closed therapy group was treated twice a week, for 3 weeks as the course of treatment. The effects of treatment were analyzed and evaluated according to the standard of curative effect. Results: The "cure rate" of the number of patients in the acupotomy group whose symptoms had completely disappeared (13 patient out of 39) was higher than the closed therapy group (1 patient out of 39), and this difference was significant (p < 0.01). The number of patients in the acupotomy group who did not benefit from the therapy (5 patients) was significantly lower than the closed therapy group (15 patients; p < 0.05). The total number of patients in the acupotomy group who benefitted from the therapy (34 patients) resulted in an effective rate of 87.18%, which was higher than the closed therapy group (24 patients; 61.53%). The difference was statistically significant (p < 0.05). Conclusion: Acupotomy is effective in the treatment of Tarsal Tunnel syndrome, was superior to traditional closed therapy, and is worthy of clinical application.

샌드위치패널 창고의 벽 천장 접합부 방호용 스프링클러설비 실험 (A Experiment of Sprinkler System to Protect Ceiling Joints of Sandwich Panel Warehouses)

  • 안병국;김운형;서동훈;함은구
    • 한국재난정보학회 논문집
    • /
    • 제15권1호
    • /
    • pp.98-108
    • /
    • 2019
  • 연구목적:본 연구는 화재 시 샌드위치패널 구조 창고의 벽 천장접합부 방호를 위한 스프링클러 성능확인 실험을 목적으로 한다. 연구방법: 현장조사결과를 기반으로 창고의 공간규격과 가연물을 선정하고 벽 코너 및 헤드 직하부에서의 방호실험을 수행하고 결과를 분석하였다. 연구결과:벽 코너 화재 시나리오에 대해서 K-80 폐쇄형 스프링클러헤드의 작동으로 샌드위치 패널의 착화 및 접합부 손상이 방지됨을 확인하였다. 결론:샌드위치패널 심재로의 착화 및 연소방지를 통한 화세제어로 이를 가정한 소방대의 소화 및 구조활동을 위한 표준진압대책이 마련되어야 한다.

정상 성인에서의 전기성문파형 검사 ; 연하장애 환자의 전기성문파형 검사를 위한 예비연구 (ELECTOROGLOTTOGRAPH IN NORMAL ADULT ; PRELIMINARY STUDY FOR ELECTROGLOTTOGRAPHIC STUDY OF SWALLOING DISORDER)

  • 김영빈;이주경;임대호;백진아;고승오;임익재;김현기;신효근
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제30권5호
    • /
    • pp.437-446
    • /
    • 2008
  • Electroglottography (EGG) is a simple and non-invasive technique for analyzing the vibratory patterns of the vocal folds by detecting impedance changes across the larynx. An abnormal electroglottogram is shown in patients who have a dysphagia associated with neuromuscular disorder. Electroglottography offers reliable informations for diagnosis of swallowing disorder and gives quantitative datas. The purpose of this study is to provide the normal value of electroglottography in normal adults. We took electroglottograms of 80 adults who have no problem in swallowing and utterance. EGG data were analyzed to find out the value of Pitch, Jitter and Closed quotient with a commercially available software. There were significant differences between a usual voice and loud voice in 3 measures on the EGG signalmean pitch, Avg. jitter, mean quotient. To get a proper electroglottography, phonation of a usual voice was better than a loud voice. Four measurements- S.D pitch, Avg. Jitter, Mean closed quotient, S.D closed quotient- were independent of sex for adult. Three measurements- Mean pitch, S.D pitch, Mean closed quotient - were independent of age for adult aged twenties to fifties. The Avg. Jitter of twenties appeared to be lower than those of forties and fifties. The S.D closed quotient of twenties appeared to be lower than those of thirties, forties and fifties.

Vegetative Growth Characteristics of Phalaenopsis and Doritaenopsis Plants under Different Artificial Lighting Sources

  • Lee, Hyo Beom;An, Seong Kwang;Lee, Seung Youn;Kim, Ki Sun
    • 원예과학기술지
    • /
    • 제35권1호
    • /
    • pp.21-29
    • /
    • 2017
  • This study was conducted to determine the effects of artificial lighting sources on vegetative growth of Phalaenopsis and Doritaenopsis (an intergeneric hybrid of Doritis and Phalaenopsis) orchids. One - month - old plants were cultivated under fluorescent lamps, cool - white light - emitting diodes (LEDs), or warm - white LEDs at 80 and $160{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. The blue (400 - 500 nm) : green (500 - 600 nm) : red (600 - 700 nm) : far - red (700 - 800 nm) ratios of the fluorescent lamps, cool-white LEDs, and warm-white LEDs were 1 : 1.3 : 0.8 : 0.1, 1 : 1.3 : 0.6 : 0.1, and 1 : 2.7 : 2.3 : 0.4, respectively. Each light treatment was maintained for 16 weeks in a closed plant-production system maintained at $28^{\circ}C$ with a 12 h photoperiod. The longest leaf span, as well as the leaf length and width of the uppermost mature leaf, were observed in plants treated with warm-white LEDs. Plants grown under fluorescent lamps had longer and wider leaves with a greater leaf span than plants grown under cool-white LEDs, while the maximum quantum efficiency of photosystem II was higher under cool-white LEDs. The vegetative responses affected by different lighting sources were similar at both 80 and $160{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Leaf span and root biomass were increased by the higher light intensity in both cultivars, while the relative chlorophyll content was decreased. These results indicate that relatively high intensity light can promote vegetative growth of young Phalaenopsis plants, and that warm - white LEDs, which contain a high red-light ratio, are a better lighting source for the growth of these plants than the cool-white LEDs or fluorescent lamps. These results could therefore be useful in the selection of artificial lighting to maximize vegetative growth of Phalaenopsis plants in a closed plant - production system.