• Title/Summary/Keyword: K-7 Mode

Search Result 1,818, Processing Time 0.028 seconds

A Study on the Short-Range Wireless Transmission Technology using the LED in Ubiquitous Environment (유비쿼터스 환경에서 LED를 이용한 근거리 무선전송 기술에 관한 연구)

  • Lee, Yang Sun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.9
    • /
    • pp.2174-2182
    • /
    • 2013
  • This paper analyzed the PHY technology of IEEE 802.15.7 which is a technology trend and international standard of the LED-based VLC communication system. Also, the study analyzed the complexity of the system as well as the reception performance in a visible light wireless channel environment by analyzing detailed technology of PHY I mode and designing the RS code and block interleaver. According to the result, concerning PHY I which is operated in a single mode, it was confirmed that the complexity in designing the system was higher compared with an environment of the transmission of a short massage. Also it was confirmed that in a multi-path visible light channel environment, the reception SNR=1.5dB was required additionally.

Damage identification of structures by reduction of dynamic matrices using the modified modal strain energy method

  • Arefi, Shahin Lale;Gholizad, Amin
    • Structural Monitoring and Maintenance
    • /
    • v.7 no.2
    • /
    • pp.125-147
    • /
    • 2020
  • Damage detection of structures is one of the most important topics in structural health monitoring. In practice, the response is not available at all structural degrees of freedom, and due to the installation of sensors at some degrees of freedom, responses exist only in limited number of degrees of freedom. This paper is investigated the damage detection of structures by applying two approaches, AllDOF and Dynamic Condensation Method (DCM), based on the Modified Modal Strain Energy Method (MMSEBI). In the AllDOF method, mode shapes in all degrees of freedom is available, but in the DCM the mode shapes only in some degrees of freedom are available. Therefore by methods like the DCM, mode shapes are obtained in slave degrees of freedom. So, in the first step, the responses at slave degrees of freedom extracted using the responses at master degrees of freedom. Then, using the reconstructed mode shape and obtaining the modified modal strain energy, the damages are detected. Two standard examples are used in different damage cases to evaluate the accuracy of the mentioned method. The results showed the capability of the DCM is acceptable for low mode shapes to detect the damage in structures. By increasing the number of modes, the AllDOF method identifies the locations of the damage more accurately.

Robust Sliding Mode Friction Control with Adaptive Friction Observer and Recurrent Fuzzy Neural Network

  • Shin, Kyoo-Jae;Han, Seong-I.
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.2
    • /
    • pp.125-130
    • /
    • 2009
  • A robust friction compensation scheme is proposed in this paper. The recurrent fuzzy neural network and friction parameter observer are developed with sliding mode based controller in order to obtain precise position tracking performance. For a servo system with incomplete identified friction parameters, a proposed control scheme provides a satisfactory result via some experiment.

Fluctuating wind loads across gable-end buildings with planar and curved roofs

  • Ginger, J.D.
    • Wind and Structures
    • /
    • v.7 no.6
    • /
    • pp.359-372
    • /
    • 2004
  • Wind tunnel model studies were carried out to determine the wind load distribution on tributary areas near the gable-end of large, low-rise buildings with high pitch planar and curved roof shapes. Background pressure fluctuations on each tributary area are described by a series of uncorrelated modes given by the eigenvectors of the force covariance matrix. Analysis of eigenvalues shows that the dominant first mode contributes around 40% to the fluctuating pressures, and the eigenvector mode-shape generally follows the mean pressure distribution. The first mode contributes significantly to the fluctuating load effect, when its influence line is similar to the mode-shape. For such cases, the effective static pressure distribution closely follows the mean pressure distribution on the tributary area, and the quasi-static method would provide a good estimate of peak load effects.

A Reconfigurable Antenna for Quad-Band Mobile Handset Application (4중 대역을 포함하는 휴대폰용 재구성 안테나)

  • Park, Young-Keun;Sung, Young-Je
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.5
    • /
    • pp.570-582
    • /
    • 2012
  • In the communication, a reconfigurable antenna using two PIN diodes is presented for quad-band(GSM900/GSM1800/GSM1900/UMTS) mobile handset applications. The proposed antenna has a size $45{\times}11{\times}6mm^3$. By independently adjusting the on/off states of two PIN diodes located on the radiating element, the proposed structure can be operated in the PIFA and loop mode, respectively. The PIN diodes are replaced by conducting tape in order to verify the concept. In regards to the fabricated reconfigurable antenna, when operating in the PIFA mode, the measured results show that the 7 dB bandwidth is 8.62 %. which covers the GSM900(880~960 MHz) band. When operating in the loop mode, the measured results show that the 7 dB bandwidth is 26.36 %, which covers the GSM1800(1,710~1,880 MHz), GSM1900(1,850~1,990 MHz), and UMTS(1,920~2,170 MHz) bands, respectively.

Wideband horn antenna including circular-polarizer and straight-type mode-converter for Ka-band (Ka-대역 원형 편파기와 직선구조 모드 변환기를 포함한 광대역 혼 안테나)

  • Jung, Young-Bae
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.299-304
    • /
    • 2011
  • In this paper, the circular polarized horn antenna composed of circular polarizer and impedance transformer is designed, and fabricated. For the circular polarizer, two types of the polarizer are designed and the electrical performance of them is compared; rectangular waveguide polarizer with $45^{\circ}$-inclined dielectric slab and oval shaped one. Straight type mode converter has a stepped impedance structure and plays a role of converting waveguide TE mode into coaxial TEM mode, and the proposed antenna is designed to directly connect with active components using the feed-through in the input port of the mode converter. Fabricated antenna has the wideband performance, VSWR<1.5 and Axial ratio < 1.0dB, ranging from 30.085 to 30.885 GHz, and the antenna gain is 6.7~7.0 dBi.

Third Order Sliding Mode Observer based Robust Fault Diagnosis for Robot Manipulators (3 계 슬라이딩 모드 관측기 기반 로봇 고장 진단)

  • Van, Mien;Kang, Hee-Jun;Suh, Young-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.7
    • /
    • pp.669-672
    • /
    • 2012
  • This paper investigates an algorithm for robust fault diagnosis in robot manipulators. The TOSM (Third Order Sliding Mode observer) provides both theoretically exact observation and unknown fault identification without filtration. The EOI (Equivalent Output Injections) of the TOSM observers can be used as residuals for the problem of fault diagnosis and to identify the unknown faults. The obtained fault information can be used for fault detection, isolation as well as fault accommodation to the self-correcting failure system. The computer simulation results for a PUMA 560 robot are shown to verify the effectiveness of the proposed strategy.

A Multi-channel CMOS Low-voltage Filter with Newly Current-mode Integrator (새로운 전류모드 적분기를 갖는 다중 채널 CMOS 저전압 전류모드 필터 설계)

  • Lee, Woo-Choun;Bang, Jun-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3638-3644
    • /
    • 2009
  • A CMOS multi-channel low-voltage current mode filter circuit is designed. The designed current-mode filter is based on linear cascode current-mode integrator that is newly proposed in this paper. When it is compared with that of the typical current-mirror type current-mode integrator, the proposed linear cascode current-mode integrator achieves high current gain and unity gain frequency. The designed filter is composed with 5th Chebyshev function and converted to active version by signal flow graph method. We verified that the designed filter can be applied to three-channel basedband, bluetooth, DECT and WCDMA with 0.51MHz~7.03MHz frequency tuning range by Hspice simulation using 1.8V-$0.18{\mu}m$ CMOS technology.

A New Criterion of Cell Discard in an ATM Switch with Input and Output Buffers (입출력버퍼형 ATM 교환기의 셀 폐기 방법에 대한 새로운 기준 제안 및 성능 분석)

  • Gwon, Se-Dong;Park, Hyeon-Min;Choe, Byeong-Seok;Park, Jae-Hyeon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.4
    • /
    • pp.1246-1264
    • /
    • 2000
  • An input-output buffering switch operates in either of tow different cell loss modes; Backpressure mode and Queueloss mode. In the previous studies, the Backpressrue mode is more effective at low traffic loads, and the Queueloss mode performs better at high traffic. We propose a new operation mode, called Hybrid mode, which adopts the advantages of he Backpressure and the Queueloss mode. Backpressure and Queueloss modes are distinguished from whether a cell loss occurs at the output buffer or not when output buffer overflows, irrespective of input buffer status. In order to simply combine Backpressure and Queueloss mode, the change of input traffic load must be measured. However, in the Hybrid mode, simply both of the input and output buffer overflow and checked out to determine the cell discard. The performance of the Hybrid mode is compared with those of the Backpressure and the Queueloss mode under random and bursty traffic. This paper show that the Hybrid mode always gives the best performance results for most ranges of load values.

  • PDF

Changes in the Ammonia-Oxidizing Bacteria Community in Response to Operational Parameters During the Treatment of Anaerobic Sludge Digester Supernatant

  • Cydzik-Kwiatkowska, Agnieszka;Zielinska, Magdalena;Bernat, Katarzyna;Kulikowska, Dorota;Wojnowska-Baryla, Irena
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.7
    • /
    • pp.1005-1014
    • /
    • 2012
  • The understanding of the relationship between ammonia-oxidizing bacteria (AOB) communities in activated sludge and the operational treatment parameters supports the control of the treatment of ammonia-rich wastewater. The modifications of treatment parameters by alteration of the number and length of aerobic and anaerobic stages in the sequencing batch reactor (SBR) working cycle may influence the efficiency of ammonium oxidation and induce changes in the AOB community. Therefore, in the research, the impact of an SBR cycle mode with alternating aeration/mixing conditions (7 h/1 h vs. 4 h/5.5 h) and volumetric exchange rate (n) on AOB abundance and diversity in activated sludge during the treatment of anaerobic sludge digester supernatant at limited oxygen concentration in the aeration stage (0.7 mg $O_2/l$) was assessed. AOB diversity expressed by the Shannon-Wiener index (H') was determined by the cycle mode. At aeration/mixing stage lengths of 7 h/1 h, H' averaged $2.48{\pm}0.17$, while at 4 h/5.5 h it was $2.35{\pm}0.16$. At the given mode, AOB diversity decreased with increasing n. The cycle mode did not affect AOB abundance; however, a higher AOB abundance in activated sludge was promoted by decreasing the volumetric exchange rate. The sequences clustering with Nitrosospira sp. NpAV revealed the uniqueness of the AOB community and the simultaneously lower ability of adaptation of Nitrosospira sp. to the operational parameters applied in comparison with Nitrosomonas sp.