• Title/Summary/Keyword: K ion

Search Result 10,760, Processing Time 1.053 seconds

EO Performances for Ion-beam Aligned TN-LCD on a DLC Thin Film Layer

  • Jo, Yong-Min;Hwang, Jeoung-Yeon;Seo, Dae-Shik;Lee, Sang-Keuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04b
    • /
    • pp.118-120
    • /
    • 2002
  • Electro-optical (EO) characteristics of the ion beam (IB) aligned twisted nematic (TN)-liquid crystal display (LCD) with oblique ion beam exposure on the diamond-like carbon (DLC) thin film surface were studied. An excellent voltage-transmittance (V-T) curve of the ion beam aligned IN-LCD was observed with oblique ion beam exposure on the DLC thin film surface for I min. Also, a faster response time for the ion beam aligned TN-LCD with oblique ion beam exposure on the DLC thin film surface for 1 min can be achieved.

  • PDF

APPLICATION OF TIN ION-PLATING TO THE ORTHODONTIC APPLIANCE (교정용 장치물에 대한 TiN Ion Plating의 응용)

  • Kwon, Oh-Won;Kim, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.21 no.1 s.33
    • /
    • pp.7-16
    • /
    • 1991
  • To estimate the possibility of the application of TiN ion-plating to the orthodontic appliance, colorimetric properties, and characteristics of ion-plated film as well as adhesive strength of TiN film to the substrate and mechanical properties of ion-plated orthodontic appliance were investigated. The obtained results were as follows: 1) TiN ion-plated film had the colorimetric properties which were the hue of about 2.5 Y, the brightness of about 6, and the chroma of about 4 by the standard color chip of JIS. 2) TiN ion-plated film was $2{\mu}m$ in thickness and its deposition pattern was rather irregular. 3) TiN phase was confirmed on the X-ray diffraction pattern. 4) Critical load for delamination of ion-plated film from stainless steel band was 10N. 5) Tensile and yield strength of ion-plated specimen was increased about 10Kg $f/mm^2$, while elongation was decreased $1\%$ compairing to the values of the non ion-plated specimen.

  • PDF

Ion Beam Assisted Crystallization Behavior of Sol-Gel Derived $PbTiO_3$ Thin Films

  • Oh, Young-Jei;Oh, Tae-Sung;Jung, Hyung-Jin
    • The Korean Journal of Ceramics
    • /
    • v.2 no.1
    • /
    • pp.48-53
    • /
    • 1996
  • Ion beam assisted crystallization behavior of sol-gel derived $PbTiO_3$ thin films, deposited on bare silicon(100) substrates by spin-casting method, has been investigated. Ar ion bombardment was directly conducted on the spincoated film surface with or without heating the film from room temperature to $300^{\circ}C$. Ion dose was changed from $5{\times}10^{15}$ to $7.5{\times}10^{16}$ $Ar^-/cm^2$. Formation of (110) oriented perovskite phase was obseerved with ion dose above $5{\times}10^{16}\; Ar^+/cm^2$. Crystallization of $PbTiO_3$ thin film could be enhanced with increasing the Air ion dose, or heating the substrate during ion bombardment. Crystallization of the $PbTiO_3$ films by ion bombardment was related to the local heating effect during ion bombardment.

  • PDF

Monitoring Ion Energy Distribution in Capacitively Coupled Plasmas Using Non-invasive Radio-Frequency Voltage Measurements

  • Choi, Myung-Sun;Lee, Seok-Hwan;Jang, Yunchang;Ryu, Sangwon;Kim, Gon-Ho
    • Applied Science and Convergence Technology
    • /
    • v.23 no.6
    • /
    • pp.357-365
    • /
    • 2014
  • A non-invasive method for ion energy distribution measurement at a RF biased surface is proposed for monitoring the property of ion bombardments in capacitively coupled plasma sources. To obtain the ion energy distribution, the measured electrode voltage is analyzed based on the circuit model which is developed with the linearized sheath capacitance on the assumption that the RF driven sheath behaves like a simple diode for a bias power whose frequency is much lower than the ion plasma frequency. The method is verified by comparing the ion energy distribution function obtained from the proposed model with the experimental result taken from the ion energy analyzer in a dual cathode capacitively coupled plasma source driven by a 100 MHz source power and a 400 kHz bias power.

A study on the design of hexapole in an 18-GHz ECR ion source for heavy ion accelerators

  • Wei, Shaoqing;Zhang, Zhan;Lee, Sangjin;Choi, Sukjin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.2
    • /
    • pp.25-29
    • /
    • 2016
  • High charge state electron cyclotron resonance (ECR) ion source is important on the performance of heavy ion accelerators. In this paper, a low temperature superconductor (LTS) was used to make a hexapole coil for an 18-GHz ECR ion source. Several hexapole structures, including racetrack, graded racetrack, and saddle were implemented and analyzed for the hexapole-in-solenoid ECR ion source system. Under the appropriate radial confinement field, the smaller outer radius of hexapole can be better for the solenoid design. Saddle hexapole was selected by comparing the wire length, maximum outer radius of the hexapole, the Lorentz force at the end part of the hexapole and the maximum magnetic field in the coil. Based on saddle hexapole, a new design for hexapoles, the snake hexapole, was developed in this paper. By comparative analysis of the Lorentz force at the end part of the saddle and snake hexapoles, the snake hexapole is much better in the ECR ion source system. The suggested design for the ECR ion source with the snake hexapole is presented in this paper.

Development of a Microwave Discharge Ion Engine using Multi-Monopole Antenna

  • Nakashima, H.;Miyamoto, T.;Mii, K.;Nishijima, T.;Ijiri, H.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.314-317
    • /
    • 2004
  • On 9/5/2003, the planet probe “HAYABUSA” as MUSES-C project was launched by The Institute of Space and Astronautical Science. “HAYABUSA” has microwave discharge ion engines and these engines are characterized by their high efficiency and specific impulse in comparison with chemical engine. A large ion engine can be used as a planet explorer, while a small ion engine can be used as attitude control of small satellite. We have been developing a high thrust density microwave discharge ion engine using “Multi-Monopole Antenna”. The performance of this engine are: ion cost of 344W/A, propellant utilization efficiency of 52% and thrust density of 0.055mN/$\textrm{cm}^2$ for Kr gas flow rate of 2.5sccm, microwave(2.45㎓) power of 32W and acceleration voltage of l.4㎸.

  • PDF

Studies on the Adsarption Characteristics of Fluoride Ion-Containing Wastewater by Employing Waste Oyster Shell as an Adsorbent (폐굴껍질을 흡착제로 한 불소폐수 처리특성에 관한 연구)

  • Lee, Jin-Suk;Kim, Dong-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.222-227
    • /
    • 2007
  • The adsorption features of fluoride ion on the oyster shell have been investigated for the purpose of the employment of waste oyster shell as an adsorbent for the treatment of fluoride ion-containing wastewater. The major component of oyster shell was examined to be Ca with minor components of Na, Si, Mg, Al, and Fe. As the initial concentration of fluoride ion was raised, its absorbed amount was enhanced at equilibrium, however, the adsorption ratio of fluoride ion compared with its initial concentration was shown to be decreased. Also, adsorption of fluoride ion onto the oyster shell resulted in the formation of $CaF_2$ in the morphological structure of adsorbent. Kinetic analysis showed that the adsorption reaction of fluoride ion generally followed a second order reaction with decreasing rate constant with the initial concentration of adsorbate. Freundlich model agreed well with the adsorption behavior of fluoride ion at equilibrium and the adsorption reaction of fluoride ion was examined to be endothermic. Several thermodynamic parameters for the adsorption reaction were calculated based on thermodynamic equations and the activation energy for the adsorption of fluoride ion onto oyster shell was estimated to be ca. 13.589 kJ/mole.

A Study on the Fabrication of STS 316L Films by Ion Beam Deposition with Ion Source (이온빔 보조 증착법을 이용한 STS 316L 박막 합성에 관한 연구)

  • Lee, J.H.;Song, Y.S.;Lee, K.H.;Lee, K.H.;Lee, D.Y.;Yoon, J.K.
    • Korean Journal of Materials Research
    • /
    • v.13 no.9
    • /
    • pp.587-592
    • /
    • 2003
  • The thin films of 316L stainless steel were made on glass and S45C substrate by Ion beam assisted deposition with reactive atmosphere of argon and nitrogen. The films were deposited at the various conditions of ion beam power and the ratios of Ar/$N_2$gas. Properties of these films were analyzed by glancing x-ray diffraction method(GXRD), AES, potentiodynamic test, and salt spray test. The results of GXRD showed that austenite phase could be appeared by $N_2$ion beam treatment and the amount of austenite phase increased with the amount of nitrogen gas. The films without plasma ion source treatment had the weak diffraction peak of ferrite phase. But under the Ar plasma ion beam treatment, the strong diffraction peaks of ferrite phase were appeared and the grain size was increased from 12 to 16 nm. Potentiodynamic polarization test and salt spray test indicated that the corrosion properties of the STS 316L films with nitrogen ion source treatment were better than bulk STS 316L steel and STS 316L films with Ar ion source treatment.

The Frictional Resistance Of Tin Ion-Plated Co-Cr Orthodontic Wire (TiN 피막처리된 Co-Cr계 교정용 선재의 마찰저항력)

  • Lee, Ho-Kyu;Kwon, Oh-Won;Kim, Kyo-Han
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.123-133
    • /
    • 1998
  • The effectiveness of TiN ion-plating was examined with TiN ion-plated Co-Cr wires(.016“, .016”x.022“) on three different types of bracket(TiN ion-plated metal bracket ceramic bracket and plastic bracket). Maximum static frictional forces and characteristic curves obtained from the frictional characteristic graph, were compared and surface roughness of wires and bracket slots before and after friction experiment was observed by SEM. The obtained results were as follows $\cdot$The frictional forces of TiN ion-plated wires were significantly lower than those of non ion-plated wires(p<0.05). $\cdot$On the effect of wire shape, the frictional forces of round wires were significantly lower than those of rectangular wires(p<0.05) $\cdot$As the result of the SEM observation on the wires and bracket slots after the friction experiment the surface of non ion-plated wires was rougher than that of TiN ion-plated ones. $\cdot$The difference between the static frictional forces and the kinetic frictional forces was not significant in case of the TiN ion-plated round ins, but the static frictional forces were a little higher than the kinetic frictional forces in the TiN ion-plated rectangular wires. $\cdot$The static frictional forces were much higher than the kinetic frictional forces in the case of non ion-plated wires.

  • PDF

Modulation of Cyclic AMP-PKA System on Inhibitory and Excitatory Herbs-induced Ion Currents (Cyclic AMP-PKA System이 억제성 및 흥분성 한약재에 의해 유발된 이온전류에 미치는 영향)

  • Kim Youn-Jung;Shin Min-Chul;Chung Joo-Ho;Lee Choong-Yeol;Kim Ee-Hwa;Kim Chang-Ju
    • Korean Journal of Acupuncture
    • /
    • v.18 no.1
    • /
    • pp.143-156
    • /
    • 2001
  • Modulatory effect of cAMP-PKA system on inhibitory- and excitatory herbs-induced ion currents were investigated by nystatin-perforated patch clamp method under voltage-clamp condition. Ion currents induced by Bupleuri radix and Coptidis rhizoma were not affected by cAMP-PKA system. Ion current induced by Ecliptae herba was partially inhibited by cAMP-PKA system. Ion currents induced by Aconiti tuber and Boshniakiae herba were inhibitory modulated and ion current induced by Zingiberis rhizoma was excitatory modulated by cAMP-PKA system. Modulation of cAMP-PKA system on ion currents induced by Ginseng radix was fluctuated. In this results, it can be seen generally that excitatory herbs-induced ion currents were modulated by cAMP-PKA system while cAMP-PKA system did not affect inhibitory herbs-induced ion currents.

  • PDF