• Title/Summary/Keyword: K groove

Search Result 729, Processing Time 0.026 seconds

Discharge Characteristics of AC-PDPs with a grooved front dielectric layer

  • Jeong, Jin-Hee;Lim, Jong-Lae;Kim, Oe-Dong;Choi, Kwang-Yeol;Yoo, Eun-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1266-1268
    • /
    • 2005
  • The influence of the grooved dielectric layer on discharge and luminous characteristics has been investigated for various depths of the groove to achieve a high luminance efficiency AC-PDP operated at a lower voltage. We use the voltagethreshold curve technique and address delay jitters to explain the discharge characteristics. It shows that the surface discharge voltage rely on the depth of the grooved dielectric layer. Vertical discharge voltage remains almost the same as the groove depth increases. The influence of the grooved dielectric layer on discharge and luminous characteristics has been investigated for various depths of the groove to achieve a high luminance efficiency AC-PDP operated at a lower voltage. We use the voltagethreshold curve technique and address delay jitters to explain the discharge characteristics. It shows that the surface discharge voltage rely on the depth of the grooved dielectric layer. Vertical discharge voltage remains almost the same as the groove depth increases.

  • PDF

Recognition and management of palatogingival groove for tooth survival: a literature review

  • Kim, Hee-Jin;Choi, Yoorina;Yu, Mi-Kyung;Lee, Kwang-Won;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.2
    • /
    • pp.77-86
    • /
    • 2017
  • Palatogingival groove (PGG) is an anomaly in the maxillary anterior teeth, often accompanied by the area of bony destruction adjacent to the teeth with no carious or traumatic history. The hidden trap in the tooth can harbor plaque and bacteria, resulting in periodontal destruction with or without pulpal pathologic change. Related diseases can involve periodontal destruction, combined endodontic-periodontal lesions, or separate endodontic and periodontal lesions. Disease severity and prognosis related to PGG depend on several factors, including location, range, depth, and type of the groove. Several materials have been used and recommended for cases of extensive periodontal destruction from PGG to remove and block the inflammatory source and recover the health of surrounding periodontal tissues. Even in cases of severe periodontal destruction, several studies have reported favorable treatment outcomes with proper management. With new options in diagnosis and treatment, clinicians need a detailed understanding of the characteristics, treatment, and prognosis of PGG to successfully manage the condition.

Geometric Modeling and Five-axis Machining of Tire Master Models

  • Lee, Cheol-Soo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.3
    • /
    • pp.75-78
    • /
    • 2008
  • Tire molds are manufactured by aluminum casting, direct five-axis machining, and electric discharging machining. Master models made of chemical wood are necessary if aluminum casting is used. They are designed with a three-dimensional computer-aided design system and milled by a five-axis machine. In this paper, a method for generating and machining a tire surface model is proposed and demonstrated. The groove surfaces, which are the main feature of the tire model, are created using a parametric design concept. An automatically programmed tool-like descriptive language is presented to implement the parametric design. Various groove geometries can be created by changing variables. For convenience, groove surfaces and raw cutter location (CL) data are generated in two-dimensional drawing space. The CL data are mapped to the tread surface to obtain five-axis CL data to machine the master model. The proposed method was tested by actual milling using the five-axis control machine. The results demonstrate that the method is useful for manufacturing a tire mold.

Real-time measurement of the width of piston ring groove on the grinding process (연삭가공 중인 피스톤 링 그루브의 실시간 연삭폭 측정법 개발)

  • Kim, Byoung-Chang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.2
    • /
    • pp.28-34
    • /
    • 2014
  • A non-contact type measurement system is specially devised to measure the width of a piston ring groove in the grinding process. This system comprises a line camera with an imaging lens, collimated white light source, and a one axis translation stage. When the measurement system movesalong the diagonal direction of the cylinder, the line camera captures an image. By analyzing such images, the width of the piston ring groove can be determined. The experimental results prove that the proposed system is useful, especially as a monitoring system in grinding piston ring grooves on cylinders with accuracy of several micrometers in an area of dozens of millimeters.

Improvement on Prediction of Circumferential-Groove-Pump Seal with CFD Analysis (CFD를 사용한 평행 홈 펌프 시일의 해석 개선)

  • Ha, Tae-Woong
    • Tribology and Lubricants
    • /
    • v.24 no.6
    • /
    • pp.291-296
    • /
    • 2008
  • In order to improve the leakage prediction and rotordynamic analysis of an annular seal with a smooth rotor and circumferentially grooved stator, CFD analysis using FLUENT has been performed to determine the groove penetration angle a which is the angle of separation line between control volumes II and III in groove section of Ha and Lee's three-control-volume theory. Validation to the present analysis using new penetration angle determined by the CFD analysis is achieved by comparisons with the results of published Ha and Lee's analysis. For the leakage prediction the present analysis shows slight improvement and CFD results yields the best. Direct damping and cross-coupled stiffness coefficients are predicted better to the experimental ones. However, direct stiffness coefficient is predicted worse.

J-Groove Technique for Suppressing Various Anomalous Flow Phenomena in Turbomachines

  • Kurokawa, Junichi
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.1-13
    • /
    • 2011
  • In operating a turbomachine at off-design conditions various instabilities caused by anomalous flow phenomena occur and sometimes lead to the damage of a turbomachine. In order to avoid these phenomena various devices characteristic to each phenomenon have been developed, however they make turbomachines large-sized and cause efficiency drop. The present author has developed a very simple and innovative device, termed "J-groove," of suppressing various anomalous flow phenomena commonly by controlling the angular momentum of the main flow. It has been revealed that J-groove makes an operation of a turbomachine stable in all flow range, causes little efficiency drop, and can be easily applied to an existing machine. Here is reviewed totally the results of suppressing various anomalous flow phenomena in turbomachines.

Analysis of Plastic Deformation Behavior during Groove pressing (Groove Pressing 공정을 통한 소성 변형 거동 연구)

  • Yoon, S.C.;Krishnaiah, A.;Chakkingal, U.;Kim, H.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.425-426
    • /
    • 2008
  • Elasto-plastic finite element analysis was carried out for analyzing the severe plastic deformation behavior of copper specimens during groove pressing. Deformation localization was studied in terms of strain variations along the longitudinal direction. Plastic strain is lower at the local interface between the shear and the flat regions, which receive very little shear during the pressing cycle. Strain localization is more intensified with the number of rove pressing cycles, although the average strain level increases.

  • PDF

A Study on Heat Transfer Performance with the Changes of Working Fluid Filling Ratio for Thermosyphon with Internal Groove (내부 그루브를 가진 열사이폰의 작동유체 봉입량 변화에 따른 열전달 성능에 관한 연구)

  • Ye, S.S.;Han, K.I.
    • Journal of Power System Engineering
    • /
    • v.4 no.3
    • /
    • pp.19-24
    • /
    • 2000
  • This study concerns the performance of the heat transfer of the thermosyphon having 80 internal groove in which boiling and condensation occur. Distilled water has been used as a working fluid. The liquid filling as the ratio of working fluid volume to total volume of thermosyphon has been used as the experimental parameters. The heat flux and heat transfer coefficient at the condenser are estimated from the experimental results. The experimental results have been assessed and compared with the existing theories. As a result of the experimental investigation, the maximum heat flow rate in the thermosyphon is proved to be dependent upon the liquid fill quantity. relatively high rates of heat transfer have been achieved operating in the thermosyphon with the internal groove. Also, a thermosyphon with the internal groove can be used to achieve some inexpensive and compact heat exchangers in low temperature. In addition, overall heat transfer coefficients and the characteristics as an operating temperature are obtained for the practical applications.

  • PDF

A study on the design wax up technique for mandibular molar occlusion surface (하악구치 교합면의 design 조각법에 관한 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.107-126
    • /
    • 2002
  • The first function of occlusion is mastication. Therefore the functional restoration of occlusal surface is very important. The restoration of occlusal surface is three method as wax bite technique, F.G.P. technique, cone technique. Many dental technician is using compound method. I am using compound method of wax bite technique and cone technique. I have knew common point on each teeth during I have waxing up wax pattern. So I studied on the design waxup technique for mandible molar occlusion. The results of the study were as follows; 1. The dam wax up method can restore axial contour of teeth very easy and make short working time of wax pattern. 2. The height of dam must be same with cusp of adjacent teeth. 3. Automatically the contour of tooth is appeared if the contour of dam is relationship with cuspid line of adjacent teeth. 4. The height of contour of buccal, lingual surface is formed natural curve to add fluid wax by gravitation. 5. The development groove of mandible first premolar is appeared V form. 6. The development groove of mandible second premolar is appeared Y form. 7, The development groove of mandible first molar is appeared M form. 8. The development groove of mandible second molar is W form. 9. The embrasure is formed to carve around contact point area as round convex. It affects to axial form of tooth. 10. The buccal, lingual groove of molar is formed parallel with direction of teeth arrangement.

  • PDF