• 제목/요약/키워드: Joint-resistance

검색결과 572건 처리시간 0.021초

STRAIN AND TEMPERATURE CHANGES DURING THE POLYMERIZATION OF AUTOPOLYMERIZING ACRYLIC RESINS

  • Ahn Hyung-Jun;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.709-734
    • /
    • 2001
  • The aims of this experiment were to investigate the strain and temperature changes simultaneously within autopolymerzing acrylic resin specimens. A computerized data acquisition system with an electrical resistance strain gauge and a thermocouple was used over time periods up to 180 minutes. The overall strain kinetics, the effects of stress relaxation and additional heat supply during the polymerization were evaluated. Stone mold replicas with an inner butt-joint rectangular cavity ($40.0{\times}25.0mm$, 5.0mm in depth) were duplicated from a brass master mold. A strain gauge (AE-11-S50N-120-EC, CAS Inc., Korea) and a thermocouple were installed within the cavity, which had been connected to a personal computer and a precision signal conditioning amplifier (DA1600 Dynamic Strain Amplifier, CAS Inc., Korea) so that real-time recordings of both polymerization-induced strain and temperature changes were performed. After each of fresh resin mixture was poured into the mold replica, data recording was done up to 180 minutes with three-second interval. Each of two poly(methyl methacrylate) products (Duralay, Vertex) and a vinyl ethyl methacrylate product (Snap) was examined repeatedly ten times. Additionally, removal procedures were done after 15, 30 and 60 minutes from the start of mixing to evaluate the effect of stress relaxation after deflasking. Six specimens for each of nine conditions were examined. After removal from the mold, the specimen continued bench-curing up to 180 minutes. Using a waterbath (Hanau Junior Curing Unit, Model No.76-0, Teledyne Hanau, New York, U.S.A.) with its temperature control maintained at $50^{\circ}C$, heat-soaking procedures with two different durations (15 and 45 minutes) were done to evaluate the effect of additional heat supply on the strain and temperature changes within the specimen during the polymerization. Five specimens for each of six conditions were examined. Within the parameters of this study the following results were drawn: 1. The mean shrinkage strains reached $-3095{\mu}{\epsilon},\;-1796{\mu}{\epsilon}$ and $-2959{\mu}{\epsilon}$ for Duralay, Snap and Vertex, respectively. The mean maximum temperature rise reached $56.7^{\circ}C,\;41.3^{\circ}C$ and $56.1^{\circ}C$ for Duralay, Snap, and Vertex, respectively. A vinyl ethyl methacrylate product (Snap) showed significantly less polymerization shrinkage strain (p<0.01) and significantly lower maximum temperature rise (p<0.01) than the other two poly(methyl methacrylate) products (Duralay, Vertex). 2. Mean maximum shrinkage rate for each resin was calculated to $-31.8{\mu}{\epsilon}/sec,\;-15.9{\mu}{\epsilon}/sec$ and $-31.8{\mu}{\epsilon}/sec$ for Duralay, Snap and Vertex, respectively. Snap showed significantly lower maximum shrinkage rate than Duralay and Vertex (p<0.01). 3. From the second experiment, some expansion was observed immediately after removal of specimen from the mold, and the amount of expansion increased as the removal time was delayed. For each removal time, Snap showed significantly less strain changes than the other two poly(methyl methacrylate) products (p<0.05). 4. During the external heat supply for the resins, higher maximum temperature rises were found. Meanwhile, the maximum shrinkage rates were not different from those of room temperature polymerizations. 5. From the third experiment, the external heat supply for the resins during polymerization could temporarily decrease or even reverse shrinkage strains of each material. But, shrinkage re-occurred in the linear nature after completion of heat supply. 6. Linear thermal expansion coefficients obtained from the end of heat supply continuing for an additional 5 minutes, showed that Snap exhibited significantly lower values than the other two poly(methyl methacrylate) products (p<0.01). Moreover, little difference was found between the mean linear thermal expansion coefficients obtained from two different heating durations (p>0.05).

  • PDF

소아에서 발생한 A군 연쇄구균에 의한 침습성 질환의 임상적 특성 분석 (Clinical Manifestations of Invasive Infections due to Streptococcus pyogenes in Children)

  • 양누리;이현승;최재홍;조은영;최은화;이환종;이현주
    • Pediatric Infection and Vaccine
    • /
    • 제21권2호
    • /
    • pp.129-138
    • /
    • 2014
  • 목적: A군 연쇄구균은 소아에서 인두염, 연조직염을 일으키며 드물게 침습성 질환을 일으키는 중요한 원인균이다. 그리하여 본 연구에서는 한국 소아에서 A군 연쇄구균 침습성 감염증의 임상 양상 및 예후에 대해 조사하고자 하였다. 방법: 1992년 3월부터 2012년 12월까지 서울대학교 어린이병원 및 2003년 3월부터 2012년 12월까지 분당 서울대학교병원에 입원한 환자 중 A군 연쇄구균 침습성 감염증으로 치료받은 18세 이하의 소아를 대상으로 하였다. 의무기록을 후향적으로 분석하여 대상환자들의 임상양상, 검사결과, 치료방법 및 예후와 합병증에 대해 조사하였다. 결과: A군 연쇄구균 침습성 감염증으로 진단 받은 총 36명의 환자 중 30명에 대해 의무기록을 확인할 수 있었다. 남자가 많았으며(남:여=2.75:1) 환자들의 중앙연령은 4년 2개월(생후 12일부터 15세까지)로 그 중 53.3%가 5세 미만이었다. 질환은 피부 및 연조직감염증(9/30, 30.0%), 국소 감염부위가 없는 균혈증(4/30, 13.3%) 그리고 관절염 및 골수염(6/30, 20.0%)가 가장 많은 것으로 확인되었다. 연쇄구균 독소쇼크증후군(3/30, 10.0%), 호흡기, 복부 및 중추신경계 감염증도 확인되었다. 전체기간 중 2012년에 환자발생이 가장 많았으며(9/30, 30.0%), 사망한 사례는 없었다. Erythromycin 및 clindamycin에 대한 항생제 내성률은 각각 3.8% 및 7.5%로 확인되었다. 결론: 본 연구를 통해 소아에서 A군 연쇄구균 침습성 감염증으로 입원치료 받은 환자들의 임상양상을 확인할 수 있었으며 주로 5세 미만의 어린 연령층에서 발생하는 것을 알 수 있었다. 지난 20년 동안 한국 소아에서 발생한 A군 연쇄구균 침습성 감염증의 임상적 특성 및 예후를 조사함으로써 향후 임상에서 환자를 빠르게 인지하고 적절하게 치료하는데 본 연구결과가 도움이 될 수 있을 것으로 생각된다.