• 제목/요약/키워드: Joint transform correlator(JTC)

검색결과 27건 처리시간 0.028초

Image Blurring Estimation and Calibration with a Joint Transform Correlator

  • Jeong, Man Ho
    • Journal of the Optical Society of Korea
    • /
    • 제18권5호
    • /
    • pp.472-476
    • /
    • 2014
  • The Joint Transform Correlator (JTC) has been the most suitable technique for real time optical pattern recognition and target tracking applications. This paper proposes a new application of the JTC system for an analysis of the blurring effect of the optical images caused by a defocused lens. We present the relation between the correlation peak, optical transfer function (OTF), and the amount of blurring caused by focusing error. Moreover, we show a possibility of calibrating the blurred image by simply measuring the correlation peak.

Binary CGH를 사용한 JTC 광암호화 시스템 연구 (A study on JTC optical encryption system using binary CGHs)

  • 주성현;정만호
    • 한국광학회지
    • /
    • 제14권5호
    • /
    • pp.491-497
    • /
    • 2003
  • Joint transform correlator(JTC)를 기반으로 이진 암호화 키를 사용하는 광 암호화 시스템을 제시하였다. 이진 암호화 키는 Pixel-oriented CGH의 설계방법을 이용하여 제작하였고, 컴퓨터 모의 실험결과를 통하여 구현된 이진 암호화 키의 독립성 및 효능을 조사하였다. CGH방법으로 구현된 이진 암호화 키의 효능을 검증하기 위하여 홀로그래픽 메모리 기반의 광 암호화 장치를 구성하여 실험을 하였으며 그 결과 높은 암호화 가능성을 나타내었다.

Analysis of Fingerprint Recognition Characteristics Based on New CGH Direct Comparison Method and Nonlinear Joint Transform Correlator

  • Jeong, Man-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제13권4호
    • /
    • pp.445-450
    • /
    • 2009
  • Fingerprint recognition using a joint transform correlator (JTC) is the most well-known technology among optical fingerprint recognition methods. The JTC method optically compares the reference fingerprint image with the sample fingerprint image then examines match or non-match by acquiring a correlation peak. In contrast to the JTC method, this paper presents a new method to examine fingerprint recognition by producing a computer generated hologram (CGH) of those two fingerprint images and directly comparing them. As a result, we present some parameters to show that fingerprint recognition capability of the CGH direct comparison method is superior to that of the JTC method.

New Iterative Filter for Fringe Adjustment of Joint Transform Correlator

  • Jeong, Man-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제14권1호
    • /
    • pp.33-37
    • /
    • 2010
  • The joint transform correlator (JTC) has been the best known technique for pattern recognition and identification. The JTC optically compares the reference image with the sample image then examines match or non-match by acquiring a correlation peak. However, the JTC technique has some problems such as weak correlation discrimination and noise which originates from the interference fringes in the Fourier transform plane. In order to solve these problems, this paper proposes a new technique of modifications of the interference fringes by adopting special iterative filters. Experimental results are presented to show that the proposed technique can successfully improve the correlation peaks and the level of discrimination.

Color Pattern Recognition with Recombined Single Input Channel Joint Transform Correlator

  • Jeong, Man-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제15권2호
    • /
    • pp.140-145
    • /
    • 2011
  • Joint transform correlator (JTC) is a well known tool for color pattern recognition for a color image. Color images have red, green and blue components, thus in conventional JTC, three input channels of these color components are necessary for color pattern recognition. This paper proposes a new technique of color pattern recognition by decomposing the color image into three color components and recombining those components into a single gray image in the input plane. This new technique needs single input channel and single output CCD camera, thus a simple JTC can be used. We present various kinds of simulated results to show that our newly proposed technique can accurately recognize and discriminate color differences.

Binary Nonlinear Joint Transform Correlator with Sinusoidal Iterative Filter in Spectrum Domain

  • Jeong, Man-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제14권4호
    • /
    • pp.357-362
    • /
    • 2010
  • The joint transform correlator (JTC) has been the best known technique for pattern recognition and identification. This paper proposes a new technique of fringe adjustment by adopting a sinusoidal amplitude-modulated iterative filter convolved with an interference fringe pattern in the joint power spectrum (JPS) domain. The comparison of our new technique and other techniques is presented to show that the newly proposed technique can successfully improve both the correlation peaks and the peak signal-to-noise ratio (PSNR). Simulated results of enhanced interference fringes are also presented.

JTC를 이용한 이동 표적 추적 시스템에 관한 연구 (A Study on the Moving Traget Tracking System using Joint Transform Correlator)

  • 이상인;서춘원;양성현;이기서;김은수
    • 한국통신학회논문지
    • /
    • 제17권7호
    • /
    • pp.749-757
    • /
    • 1992
  • 본 논문에서는 maneuvering 하는 이동 표적을 실시간으로 추적하기 위한 보다 효과적인 접근 방법으로, 방대한 입력 표적 영상 데이터를 몇 개의 간단한 상관신호로 변환이 가능한 광 JTC(Joint Trasform Correlator)를 이용하여 실시간 이동 표적추적 시스템을 구현하였다. 실시간 구현을 위해 고해상도를 갖는 LCD(Liquid Crystal Display) 공간 광 변조기를 사용하여 광 JTC를 구성하고, 상관 첨두치의 배경 잡음에 대한 영향을 효과적으로 감소시키기 위한 이진화 방법으로 mean 방법을 사용하였으며, maneuvering하는 이동 표적에 대한 추적 실험을통해 광 JPC를 이용한 실시간 이동 표적 추적 시스템의 구현 가능성을 제시하였다.

  • PDF

New Random and Additional Phase Adjustment of Joint Transform Correlator

  • Jeong, Man-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제14권2호
    • /
    • pp.90-96
    • /
    • 2010
  • Joint transform correlator (JTC) has been the most suitable technique for real time pattern recognition. This paper proposes a new phase adjustment which adopts two steps of random phase adjustment in the spatial domain and additional phase adjustment in the Fourier domain. Simulated results are presented to show the optimum condition of the phase adjustment and the effect on the correlation peaks, the peak signal-to-noise ratio and the level of discrimination.

A Joint Transform Correlator Encryption System Based on Binary Encoding for Grayscale Images

  • Peng, Kaifei;Shen, Xueju;Huang, Fuyu;He, Xuan
    • Current Optics and Photonics
    • /
    • 제3권6호
    • /
    • pp.548-554
    • /
    • 2019
  • A binary encoding method for grayscale images is proposed to address their unsatisfactory decryption results from joint transform correlator (JTC) encryption systems. The method converts the encryption and decryption of grayscale images into that of binary images, and effectively improves decrypted-image quality. In the simulation, we replaced unencoded grayscale images with their binary encoded counterparts in the JTC encryption and decryption processes, then adopted a median filter to suppress saturation noise while keeping other settings unchanged. Accordingly, decrypted-image quality was clearly enhanced as the correlation coefficient (CC) between a decrypted image and its original rose from 0.8237 to 0.9473 initially, and then further to 0.9937, following the above two steps respectively. Finally, optical experimental results confirmed that the proposed encryption system works correctly.

JTC 구조를 이용한 광학적 영상 암호화 시스템 (An optical encryption system for Joint transform correlator)

  • 박세준;서동환;이응대;김종윤;김정우;이하운;김수중
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.63-66
    • /
    • 2001
  • In this paper a binary image encryption technique and decryption system based on a joint transform correlator (JTC) are Proposed. In this method, a Fourier transform of the encrypted image is used as the encrypted data and a Fourier transform of the random phase is used as the key code. The original binary image can be reconstructed on a square law device, such as a CCD camera after the joint input is inverse Fourier transformed. The proposed encryption technique does not suffer from strong auto-correlation terms appearing in the output plane. Based on computer simulations, the proposed encryption technique and decoding system were demonstrated as adequate for optical security applications.

  • PDF