• Title/Summary/Keyword: Joint development

Search Result 1,980, Processing Time 0.035 seconds

A development for a multi-joint biomechanical Rehabilitation system (생체역학적 다관절 재활운동 시스템의 개발)

  • 장재호;안정석;한창수;한정수;안재용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1180-1185
    • /
    • 2004
  • The purpose of this study is to develop a Multi-joint rehabilitation system (CMRS : C&R Lab. Multi-joint Rehabilitation System). This study presents the mechanism of rehabilitation system that enables rehabilitation of multi-joint with kinematical analysis for joints of human body. Also, the relative positioning between human subjects and the head part to rehabilitate for the mechanism is based on robotics and anatomy. This study was verified with simulations. Finally, Automation of positioning was realized. Rehabilitation exercises in passive mode were enabled with the results.

  • PDF

Development of Standard Golf Swing Motion Modeling System (골프 표준 스윙 자세 구현 시스템 개발)

  • 이지홍;조복기;김기웅;심형원;유병욱
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.121-124
    • /
    • 2002
  • This paper explains the system which finds the data of the joint of Wire Frame(that express the body structure of the golfer) from standard golf swing movie. Also, this paper used interpolation and the method which modify the distance between a joint and a close joint to general new joint data. Last this paper explains the system that make a standard golf swing attitude by continuous display the static attitude(which are formed with Wire Frame) of golf swing operations.

  • PDF

An Immune-Electron Microscopic Study of the Apoptotic Cell during Mouse Knee Joint Development (생쥐 무릎관절 공간 발생에 있어 아포프토시스 세포에 관한 면역전자현미경적 연구)

  • Chae, Hee-Sun;Kim, Kyung-Yong;Lee, Won-Bok;Lim, Hyoung-Soo;Hwang, Douk-Ho;Chang, Ka-Yong
    • Applied Microscopy
    • /
    • v.28 no.1
    • /
    • pp.107-119
    • /
    • 1998
  • This study was designed to investigate the appearence and the characteristics of the apoptotic cells and the process of the joint cavity formation in mouse knee joint. Fetal mouse knee joints from 15 to 19 days of gestation were used. Paraffin-embedded serial sections, stained with H & E for light microscopic observation, Epon 812 embedded thin sections for electron microscopic observation and Lowicryl HM 20 embedded thin sections for immune-electron microscopic observation were prepared. Monoclonal antibodies to $\beta-tubulin$ and polyclonal antibodies to tissue transglutaminase were used for immune-electron microscopic study. The results obtained were as follows. 1. At 15 days of gestation, blood vessels, which have invaded in the mesenchymal cells, were present in the synovium, to form the joint cavity in the future. 2. At 16 days of gestation, the joint cleft was first appeared and several RBCs were present in the joint cleft. The invasion of blood vessels into the joint cleft was continuing, and apoptotic cells were present in the inner cell layer, adjacent to the joint cleft. Necrotic cells were also present in the outer cell layer; they were present 18 days of gestation, but apoptotic cells did not appear after 17 days of gestation. 3. In the apoptotic cells, transglutaminase were localized around vacuoles and the marginal site of the cytoplasm. 4. In the apoptotic cells, tubulin was around the endoplasmic reticulum and the marginal site of the cytoplasm. In the late stage of apoptotic cells, tubulin was localized diffusely in the cytoplasm. Tubulin was also strongly labeled around in the cytoplasm of the neighboring cell at which the apoptotic body was phagocytosed. Tubulin labeled particles were apparently increased in the seperated apoptotic bodies. On the basis of the above findings, it is proposed that during the development of the mouse knee joint, blood vessel invasion first occurs and then apoptosis and cell necrosis follow it. In the apoptotic cell, present in the synovium of the developing knee joint of the mouse. it is suggested that the redistribution of tubulin is associated with apoptotic process. And transglutaminase overexpressed in the apoptotic cell.

  • PDF

A Study on Mission Software Reliability Test Methods of International Joint Development Project for KT-1 Military Aircraft Software (KT-1 군항공기 소프트웨어 국제공동개발 사업의 미션 소프트웨어 신뢰성 시험방안에 관한 연구)

  • Byung Duck Bae;Seonah Lee
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.6
    • /
    • pp.108-117
    • /
    • 2023
  • Thus far, a mission software component of the KT-1 military fixed-wing aircraft for overseas export has been developed through international joint development with foreign companies. The reliability of the software component could be certified by complying with the development environment and procedures of foreign companies based on DO-178B. However, recently, DO-178C certification is required for overseas exports, and reliability tests to comply with the weapon system software development guidelines are required for domestic military forces. In this paper, we describe the problems in obtaining domestic airworthiness certification in the international joint development of a previously developed KT-1 export-typed aircraft system integration project. To this end, we find a solution to comply with both DO-178C and the Weapon System Software Development and Management Manual and provide the optimal software reliability test method.

A Study on Furniture Terminology (I) -For Traditional Korean Furniture- (가구 용어 연구 I -소목 관련 용어 중심으로-)

  • Moon, Sun-Ok
    • Journal of the Korea Furniture Society
    • /
    • v.20 no.1
    • /
    • pp.61-70
    • /
    • 2009
  • This study intended to explore English of furniture tenn in relation to the joints and moldings in traditional Korean wood furniture, a base of Korean wood furniture, for the development of Korea furniture in the future. The joints such as butt joint, rabbeted joint, mitered joint, mortise-and-tenon joint, fist joint, and finger joint, and the moldings such as a piece of thread molding, half-circle molding, cove molding, flat molding, and triangle molding were analyzed between English and Korean language. The results were only basic terms which must be researched and unified in the traditional Korean furniture. Therefore, the terms in relation to the types, the details, the hardware, and so on, will have to be studied in terms of the meaning originated from the traditional craftsmen.

  • PDF

Development of Humanoid Joint Module for Safe Human-Robot Interaction (인간과의 안전한 상호 작용을 고려한 휴머노이드 조인트 모듈 개발)

  • Oh, Yeon Taek
    • The Journal of Korea Robotics Society
    • /
    • v.9 no.4
    • /
    • pp.264-271
    • /
    • 2014
  • In this study, we have developed the humanoid joint modules which provide a variety of service while living with people in the future home life. The most important requirement is ensuring the safety for humans of the robot system for collaboration with people and providing physical service in dynamic changing environment. Therefore we should construct the mechanism and control system that each joint of the robot should response sensitively and rapidly to fulfill that. In this study, we have analyzed the characteristic of the joint which based on the target constituting the humanoid motion, developed the optimal actuator system which can be controlled based on each joint characteristic, and developed the control system which can control an multi-joint system at a high speed. In particular, in the design of the joint, we have defined back-drivability at the safety perspective and developed an actuator unit to maximize. Therefore we establish a foundation element technology for future commercialization of intelligent service robots.

Development of a Joint Torque Sensor Fully Integrated with an Actuator

  • Kim, Bong-Seok;Yun, Seung-Kook;Kang, Sung-Chul;Hwang, Chang-Soon;Kim, Mun-Sang;Song, Jae-Bok
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1679-1683
    • /
    • 2005
  • This paper suggests the new type of a joint torque sensor which is attached at each joint of a manipulator for making compliance. Previous six axis force/torque sensors are high cost and installed end-effector of the manipulator. However, torque on links of previous an end-effector cannot be measured. We design a joint torque sensor that can be fully integrated with an actuator in order to measure applying torque of the manipulator. The sensor system is designed through the structural analysis. The proposed joint torque sensors are installed to the 6 DOF manipulator of a mobile robot for hazardous works and we implemented experiments of measuring applied torque to the manipulator. By the experiment, we proved that the proposed low-cost joint torque sensor gives acceptable performance when we control a manipulator.

  • PDF

Board level joint reliability of differently finished PWB pad (PCB Pad finish 방법에 따른 solder의 Board level joint reliability)

  • Lee W. J.;Moon H. J.;Kim Y. H.
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2004.02a
    • /
    • pp.37-59
    • /
    • 2004
  • In the case of Ni/Au finished pad on the package side, the solder joint of SnAgCu system can bring brittle fracture under impact load such as drop test. Therefore, it's difficult to prevent the brittle fracture of lead-free solder, by controlling Cu content. The failure locus existing on the interface between $(Ni,Cu)_3Sn_4\;and\;(Cu,Ni)_6Sn_5$ IMC layers must be changed to other site in order to avoid brittle fracture due to impact load. It was not found any clear evidence that there were two IMC layers exist. But it was strongly assumed these were two layers which have different Cu-Ni composition. From the above analysis it was assumed that Cu atom in the solder alloy or substrate seemed to affect IMC composition and cause to IMC brittle fracture.

  • PDF