• Title/Summary/Keyword: Joint development

Search Result 1,980, Processing Time 0.036 seconds

A Study on the Contact Stress Analysis of the Artificial Hip Joint Using Finite Element Method (유한요소법을 이용한 인공 고관절의 접촉응력 해석에 관한 연구)

  • 김청균;윤종덕
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1996.10a
    • /
    • pp.189-194
    • /
    • 1996
  • The modern orthopaedics frequently uses the total hip replacement in the artificial hip joint. The wear in this joint requires the re-replacement of the hip joint beacuse it is under the severe load and friction conditions. To solve these problems the previous studies have been mainly focused on the development of the new materials. The research of new material, however, needs much time and effort since it should be experimented for its bio-compatibility, friction, and wear characteristics. To reduce the work, in this study, the finite element analysis is applied to find the new combination of the materials in the total hip replacement which has the excellent contact characteristics. The finite element uses MARC and the 5-node aximetric element. The results show that in case of acetabulum UHMWP has good characteristics, in femoral head, the $Al_2O_3$, and in stem, Ti6Al4V.

  • PDF

Evaluation of High Temperature Strength Characteric in Joint Metal (접합재의 고온강도 특성 평가)

  • Huh, Sun-Chul;Park, Young-Chul;Yun, Han-Ki;Park, Won-Jo
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.103-108
    • /
    • 2000
  • Since the ceramic/metal joint material is made at a high temperature, the residual stress development when it is cooled from bonding temperature to room temperature due to remarkable difference of thermal expansion coefficient between ceramic and metal. As residual stress at ceramic/metal joints influences the strength of joints, it is important to estimate residual stress quantitatively. In this study, it is attempted to estimate joint residual stress of $Si_3N_4/STS304$ joints quantitatively and to compare the strength of Joints. The difference of residual stress is measured when repeated thermal cycle is loaded under the conditions of the practical use of the ceramic/metal joint. And 4-point bending test is performed to examine the influence of residual stress on fracture strength. As a residual it is known that the stress of joint decreases as the number of thermal cycle increases.

  • PDF

A study on related factors of knee joint pain in teachers (일선 교사들의 무릎관절 통증에 영향을 미치는 요인)

  • Park Don-mork
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.3
    • /
    • pp.106-115
    • /
    • 2002
  • This study examined on the causes of chronic pain in the knee joint that was related to the aspects of teacher's job and daily lives. The subjects of investigation in this study include 237 of teachers who work at the elementary, middle and high schools. The chronic pain of knee joint of the subjects' is mainly related to their stress, and also to the vehicle that they normally use(p<0.05). This study aims at grasping the frequency of the pain which is caused by a knee joint's stress when teachers teach in a standing-up posture for many hours, looking at the aspects in the pain of knee joint that are related to job, being conducive to the development of the pain-cure, and, in addition, presenting an effective countermeasure to related agencies in order to prevent such diseases as arthritis.

  • PDF

Development of Pre-Position device for CV Joint Measurement System (CV Joint 측정시스템용 Pre-Position 장치 개발에 관한 연구)

  • Kim D. W.;Part K. S.;Kim B. J.;Moon Y. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.156-159
    • /
    • 2005
  • The outer race of CV(constant velocity) joint is an important load-supporting automotive put that transmits torque between the transmission gear box and driving wheel. The outer race is difficult to forge because its shape is very complicated and the required dimensional tolerances are very small. To guarantee the dimensional accuracy of the forged CV Joint, the quick and precise measurement is required to increase the inspection speed of forged products. Therefore in this study, PP(Pre-Position) Device to decrease the inspection time of measuring system has been developed to cope with forging cycle time. The measured inspection time confirms that the PPD is very effective in decreasing inspection time.

  • PDF

Development of a Modified Exoskeletal Linkage Type Instrument for 3-D Motion Measurement of the Human Knee Joint (무릎관절의 3차원 회전량 측정을 위한 개선된 외골격 링크장치 형태의 측정기구 개발)

  • 김영은;안정호
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.289-294
    • /
    • 1994
  • A new type of electrogoniometer to measure the three dimensional motion of the human knee joint was developed. This instrument is composed of six potentiometers: four arranged for two universal joints, one for pin joint, and one for axial rotation measurement. The voltage change in six potentiometers were collected through A/D converter for acquisition, storage and analysis. With a developed instrument, gait analysis was performed. Compared to earlier developed triaxial type goniometer, new instrument shows its convenience in application and accuracy in measurement.

  • PDF

고속철도 교량 신축이음장치의 내구성 실험

  • 김병석;곽종원;신호상;김영진;박성용;장익순
    • Proceedings of the KSR Conference
    • /
    • 1998.11a
    • /
    • pp.24-29
    • /
    • 1998
  • To absorb the deformation of ,external live load, thermal gradient, shrinkage and creep in bridge structures and general structures, expansion joint has to be established. Especially expansion joint for high-speed railway bridge has to accomodate the static and dynamic forces and it not only has the durability of itself but also maintain the durability of structure by preventing the leakage of water. The actual used product of expansion joint for high-speed railway bridge is only ones made in France, Germany and Japan. In this study, the development process and test results of developed expansion joint are introduced which has the functional operation and durability enough to apply to high-speed railway bridges, roadway bridges and general structures. The tests consist of fatigue-durability test of 3 million times by high-speed rail load, leakage test and jack-up test for verifying the possibility of exchanging it. The performance of developed expansion joint satisfy the specification of Korea High Speed Rail Construction Authority.

  • PDF

A Study on the Nuclear Development of North Korea and South-North Mutual Nuclear Inspection (북한의 핵개발과 남북 상호사찰 방안)

  • Park Seung-Gi
    • Journal of the military operations research society of Korea
    • /
    • v.18 no.1
    • /
    • pp.1-14
    • /
    • 1992
  • As North Korea signed 'the Korea Peninsula Non-Nuclearization Joint Declaration' at the end of last year as well as full-scope safeguards agreement with the IAEA in Jan.30 1992, her nuclear activity was incorporated into the international monitoring system and opportunities were arranged to .obstruct her nuclear weapon development and nuclear material diversion, which have been international issues up to recent years. However, achieving goals of the Joint Declaration and safeguards agreement should presuppose North Korea's sincerity toward the abandonment of nuclear weapon development. In this study, first of all, her nuclear policy, current situation of nuclear development and the capability of nuclear development are analyzed. Also, based on the analysis. attempts have been made to find methods of effective performance of the South-North Korea mutual nuclear inspection and the suggested methods are as follows; 1) Analysis of the limits of IAEA inspection and suggestion of its supplementary strategies 2) Securing and training professional inspectors for the South-North mutual inspection 3) Establishment of the verification technology to detect nuclear material diversion.

  • PDF